Abstract
Purpose
This study investigated the diagnostic value of simultaneous 18F-fluordeoxyglucose positron emission tomography/magnetic resonance imaging (PET/MRI) in suspected periprosthetic joint infection (PJI) of the hip and knee.
Methods
Sixteen prostheses from 13 patients with suspected PJI were prospectively examined using PET/MRI. Image datasets were evaluated in consensus by a radiologist and a nuclear physician for the overall diagnosis of ‘PJI’ (yes/no) and its anatomical involvement, such as the periprosthetic bone margin, bone marrow, and soft tissue. The imaging results were compared with the reference standard obtained from surgical or biopsy specimens and subjected to statistical analysis.
Results
Using the reference standard, ten out of the 13 prostheses (ten hips, threes knees) were diagnosed with PJI. Using PET/MRI, every patient with PJI was correctly diagnosed (sensitivity, 100%; specificity, 100%). Considering the anatomical regions, the sensitivity and specificity were 57% and 50% in the periprosthetic bone margin, 75% and 33% in the bone marrow, and 100% and 100% in the soft tissue.
Conclusion
PET/MRI can be reliably used for the diagnosis of PJI. However, assessment of the periprosthetic bone remains difficult due to the presence of artefacts. Thus, currently, this modality is unlikely to be recommended in clinical practice.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Primary hip and knee arthroplasty is one of the five most frequently performed procedures annually [1]. Complication rates for elective hip or knee arthroplasty range from 0.5 to 10%, with periprosthetic joint infection (PJI, 14.5–25.1%) being the third most common complication after aseptic loosening and dislocation, occurring with a latency of less than three months (early) to more than 24 months (late) [2,3,4,5,6].
Accurate and early diagnosis of PJI is crucial to reduce morbidity [7, 8]. The distinction between aseptic loosening and bacterial infection is important, as it affects the surgical method [9]. PJI differs from simple bone and joint infections as a complex entity. The implant colonised with microorganisms becomes a permanent reservoir, which makes successful diagnosis and treatment difficult [10, 11]. The proof of PJI is through microbiological detection of pathogens by tissue sampling or intraoperative smears. This is preceded by clinical examination, blood tests, and radiological and nuclear imaging techniques.
In conventional radiography, which is usually the modality used first, typical signs of PJI can be indicated by periprosthetic osteolysis, loosening margins, or periarticular calcifications. However, these signs are late indicators. Cross-sectional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) can be affected by artefacts due to metal implants. In addition, post-operative changes are sometimes difficult to distinguish from signs of PJI. Metabolic changes usually precede morphologic findings, and functional imaging modalities can usually reveal pathological findings earlier than conventional imaging. Scintigraphic techniques, such as antigranulocyte scintigraphy, have a sensitivity of up to 95% [12]. With a significantly better spatial resolution, 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) is applied, especially for the exclusion of PJI [13, 14]. Nevertheless, MRI offers the highest spatial and tissue resolution in this regard and visualises periprosthetic bone and soft tissues [15]. Technical innovations in recent years have established metal artefact reducing sequences and allow assessment of post-operative complications after arthroplasty [16, 17].
Hybrid imaging of combined and simultaneous MRI and PET potentially detects early changes in infected tissue and morphologically images the precise extent of PJI (spread in bone or soft tissue). Simultaneous 18F-FDG-PET/MRI has been a powerful diagnostic tool for spinal infections [18]; however, its value in PJI has not been systematically studied [19].
This monocentric, prospective exploratory pilot study aimed to evaluate the clinical applicability of simultaneous acquisition of 18F-FDG-PET/MRI in the diagnosis of PJI and to assess its sensitivity and specificity.
Materials and methods
Patient population
This single-centre study prospectively enrolled 13 patients with clinically inconclusive suspected PJI after initial prosthesis implantation between December 2018 and December 2019. Informed written consent was obtained from each patient prior to enrolment. The trial was registered in the German Registry of Clinical Trials (DRKS00021211). The study was approved by the local ethics committee (335–17-ek) and performed in accordance with the Declaration of Helsinki. This study focuses on uncertain suspected cases of PJI. In patients with suspected PJI and multiple arthroplasties (knee or hip), all arthroplasties were considered potentially infected and included in the study. The following inclusion criteria were defined: patients with clinically inconclusive suspected PJI after hip or knee arthroplasty, age > 18 years and MRI compatibility of hip or knee arthroplasty. Patients with evident PJI, for example with definite joint empyema and/or remarkable radiographic signs of loosening, were excluded in this study. Further exclusion criteria were applied: pregnancy or breastfeeding, decompensated diabetes mellitus or fasting blood glucose values > 12 mmol/l on the day of examination, general MRI contraindications (e.g. non-MRI compatible implants, claustrophobia), contrast agent intolerance, incomplete image datasets (e.g. motion artefacts), and renal insufficiency (glomerular filtration rate < 30 ml/min). Possible previous interventions (e.g. biopsy and arthroscopy) in the examination area had to be at least 8 weeks before the examination day.
The primary outcomes were the clinical applicability and sensitivity and specificity of PJI by simultaneous acquisition of 18F-FDG PET/MRI. The secondary outcome was the extent of infection in the periprosthetic bone margin, bone marrow of the femoral or tibial shaft, and the soft tissue using the aforementioned imaging modalities.
Simultaneous 18F-FDG PET/MRI
The combined PET/MRI system (mMR-Biograph®, Siemens Healthcare, Erlangen, Germany) used in this study combines a 3 T MRI with an integrated PET scanner. Whole-body sequential PET/MRI scanning was performed from the lower thigh to the skull with a five minute acquisition time per bed position. Image acquisition commenced on an average of 75 (range 60–105) min after intravenous administration of 18F-FDG at a dose of 4 MBq/kg after a fasting period of at least six hours. Attenuation correction of the PET data was performed with a four-tissue (fat, soft-tissue, air, and background) model attenuation map obtained from a Dixon–volume-interpolated breath-hold examination MR sequence.
MR images of the hip or knee were obtained in the neutral lying position using a 16-channel body array coil. The examination protocol comprised a coronal turbo inversion recovery magnitude sequence, coronal T1-weighted (T1W) sequence without fat suppression prior to and after intravenous administration of a gadolinium-based contrast medium, sagittal T1W sequence, and axial T2W sequence without fat suppression (Table 1). All sequences were acquired with high bandwidth parameters and view angle tilting to reduce metal artefacts from prosthesis components. For contrast-enhanced MRI, a single gadobutrol dose of 0.1 mmol/kg, at a rate of 3 mL/s and flushed with 10 mL of saline, was administered.
Image interpretation
An interdisciplinary analysis of the PET/MRI datasets was performed together with a nuclear medicine specialist with ten years experience and a musculoskeletal board-certified radiologist with six years experience. Both readers only received information on the clinical suspicion of PJI and the area of the patients’ pain. Image analysis was blinded for both readers to laboratory parameters and histopathology/microbiologic results. The PET/MRI image studies were evaluated in combination simultaneously by both readers, taking into account the following findings: PET findings were considered positive for PJI if noticeably increased diffuse 18F-FDG uptake was detected periprosthetically (especially at the bone–prosthesis interface, which suggests infection) or in the surrounding tissue and negative if there was no diffuse uptake in this region. The mean and maximum standardised uptake values (SUVmean and SUVmax) were determined by placing a volume of interest around the respective region (SUVmax threshold, 40%). PJI-suspicious MRI findings included T2W-hyperintense signal alterations and contrast enhancement at the metal–bone interface and the periosteum, significant alterations in the surrounding bone marrow and surrounding soft tissue, muscle oedema, and presence of fluid collections or an abscess. The diagnosis were dichotomised into ‘PJI’ and ‘no PJI’. The evaluation was performed for the overall diagnosis of ‘PJI’ and separately for each anatomical region: periprosthetic bone margin, bone marrow of the femoral or tibial shaft, and the soft tissue.
Reference standards
The imaging results were compared with the results of histopathological and microbiological analyses of surgical or biopsy specimens as reference standards following a major criterion of PJI according to Parvici et al. [20]. Depending on the extent of the surgical procedure, samples of the implantation sonication, soft tissues, or bone marrow may be available for evaluation.
Statistical analysis
If not otherwise stated, for quantitative variables, the descriptive normally distributed data are given as mean ± standard deviation and the non-normally distributed as median and range.
Sensitivity, specificity, positive predictive value, and negative predictive value were calculated and reported as a percentage. Statistical analysis was performed using commercial software (IBM SPSS Statistics for Windows, Version 24.0. IBM Corp. Armonk, NY, USA).
Results
Thirteen (seven men, six women; median age, 71.5 [range, 52–85] years) patients underwent simultaneous 18F-FDG-PET/MRI examination. The mean time between implantation and PET/MRI was 5.8 (min–max, 0.5–7.8) years. Ten patients were included in the final analysis (Table 2). Three patients were excluded because their image files were not analysable due to incomplete image acquisition (restlessness and excessive movement artefacts).
Thirteen prostheses were analysed, as three patients had bilateral prosthesis implants. Joint prosthesis complaints were reported (median duration, 4 ± 2 [range, 1–7] years). PET/MRI was performed for a mean of six (range, 3–15) days before the reference standard.
According to the reference standard, ten of the 13 prostheses were diagnosed with PJI. In three patients with bilateral implants, PJI of the nonpainful prosthesis was ruled out by joint puncture. In ten prostheses, there was an indication for surgical revision, and PJI was confirmed. Thus, ten implant sonication samples, ten soft tissue samples, and seven samples of periprosthetic bone marrow were analysed. Figure 1 shows a patient with bilaterally implanted hip prosthesis and left-sided increased 18F-FDG uptake surrounding the prosthesis on histologically proven PJI. In this case, the diagnosis of left-sighted PJI was confirmed by prosthesis replacement. Figure 2 shows an example of inflammation of the periprosthetic bone marrow.
In the analysis of the MRI datasets alone, the periprosthetic bone margin could not be reliably assessed in eight prostheses and bone marrow in six patients because of severe artefacts. With simultaneous PET/MRI, all ten confirmed PJIs were correctly diagnosed or excluded (sensitivity, 100%; specificity, 100%). Table 3 shows the results of PET/MRI assessment according to the reference standard. Considering the anatomical areas, using PET/MRI, the periprosthetic bone margins could not be reliably assessed due to severe artefacts of the two prostheses. PET/MRI was false positive in the bone marrow area and periprosthetic bone margin in two and one protheses, respectively. False-negative findings in the periprosthetic bone margin and bone marrow were observed in three and one arthroplasties, respectively. The mean SUVmean and SUVmax in PJI were 3.6 ± 1.9 and 6.7 ± 3.7, 3.7 ± 2.1 and 6.7 ± 4.3, and 3.7 ± 1.8 and 6.9 ± 3.5 in the periprosthetic bone margin, bone marrow, and soft tissue, respectively.
The pathogens found in cultures were Corynebacterium mucifaciens (1), Staphylococcus capitis (1), Staphylococcus aureus (1), Staphylococcus epidermidis (2), Enterococcus faecalis (2), Cutibacterium acnes (1), S. epidermidis and S. capitis (1), Streptococcus species, and Corynebacterium species (1).
Discussion
This study demonstrates that PJI can be reliably diagnosed using simultaneous 18F-FDG-PET/MRI with a sensitivity and specificity of both 100%. The challenge of conservative imaging methods is the detection of tissue changes, which often can only be detected radiographically and by CT after a prolonged infection. Furthermore, post-operative MRI signs of PJI are controversially discussed in the literature.
The use of metal artefact-reducing MRI sequences greatly improves image quality and has been successfully used to assess complications after joint replacement [21, 22]. Previous studies have shown in a collective of 140 cases on a 1.5 T MRI scanner that the presence of periosteal reactions, capsular oedema, and intramuscular oedema after total hip arthroplasty has high accuracy in evaluating PJI, resulting in sensitivity and specificity of 78–95% and 86–95%, respectively, for the diagnosis of PJI [23]. Periosteal bone formation was significantly specific (100%), but with low sensitivity (16%) [24]. Although intramuscular collections are specific for PJI, they are not always present. PET/MRI showed that the highest sensitivity and specificity (100% and 100%) were achieved in the evaluation of the anatomical regions when assessing the soft tissues. MRI assessment of the periprosthetic bone margin was not possible in eight patients because of severe artefacts. We used a hybrid simultaneous PET/MRI scanner with a field strength of 3.0 T. Recent MRI studies have shown that metal artefacts are lower when scanning at a field strength of 1.5 T than at a field strength of 3.0 T [22]. This could be a reason for the reduced MRI assessment of the periprosthetic bone margin and bone marrow in our study. Ultimately, the use of artefact-reducing sequences allowed for a significantly good anatomic mapping of the tracer uptake of the PET data. With the addition of PET studies, the periprosthetic bone margin could not be assessed in two patients due to severe artefacts.
In recent years, nuclear medicine techniques for the diagnosis of PJI have been well studied. Hence, 18F-FDG PET has shown great promise for the evaluation of infections and inflammation in several studies [14]. However, in the diagnosis of PJI, there are different results regarding sensitivity and specificity. In Verbene et al.’s meta-analysis, the sensitivity and specificity of 18F-FDG-PET were 70% and 84%, respectively, and 18F-FDG-PET was less specific in diagnosing periprosthetic knee infection than combined leukocyte and bone marrow scintigraphy and antigranulocyte scintigraphy [12]. Another meta-analysis reported that the pooled sensitivity and specificity of 18F-FDG-PET or PET/CT in detecting PJI were 86% and 86%, respectively [25], which were lower than those in our study. Although the detection of patients with an overall diagnosis of PJI by PET/MRI was significantly reliable, there were six misdiagnoses in the periprosthetic bone and adjacent marrow area on anatomical review. An important reason for these results could be the lack of uniform criteria for the interpretation of PET findings [14]. Nonspecific 18F-FDG accumulation around the head and neck area of the prosthesis may be present post-operatively for a long time over several months after implantation. Currently, the location and pattern of FDG accumulation appear to be more important than the uptake intensity at these sites [26,27,28]. This finding was published in 2002 by Chacko et al. in patients with hip arthroplasty [28]. The authors concluded that the intensity of increased FDG uptake is less important than the location of increased FDG uptake when FDG-PET is used to diagnose PJI and that using an increased tracer uptake as the sole criterion for diagnosing PJI, a higher rate of false-positive results will occur. Chacko et al. emphasised in their study that the images from patients with histologically proven PJI displayed increased tracer uptake along the interface between the bone and prosthesis and that the intensity of the increased tracer uptake varied from mild to moderate, with SUV less than 2. In contrast, images from uninfected, loose hip prostheses revealed significantly intense focal uptake around the head or neck of the prosthesis with SUV as high as 7. Other investigators have also shown that quantitative SUV measurements cannot reliably differentiate between infection and aseptic loosening [29]. Therefore, we did not perform SUV-based diagnosis and focused on the pattern of 18F-FDG-accumulationn. According to our inclusion criteria without patients with evident PJI, for example, joint empyema, mild to moderate tracer uptake corresponds with the corresponding lower SUV values, which also support the above-mentioned results of Chacko et al.
In contrast, the different results could be due to the different examination techniques. Occasionally, 18F-FDG-PET examinations were performed with a stand-alone PET system, whereas others performed integrated PET/CT scan, which has become the standard method at most institutions. Metallic endoprostheses cause strong streak artefacts in CT images, which may lead to over- or underestimation of periprosthetic activity concentration and hamper semiquantitative PET evaluation when CT-based attenuation correction of PET images is used. This may explain the discrepancy in diagnostic performance proportionally. However, the anatomic discriminative resolution of PET/CT is lower than that of MRI. PET/MRI hybrid imaging potentially detects changes in the infected tissue with the highest contrast and spatial resolution of periprosthetic bone and soft tissue [15, 30]. Ultimately, artefact susceptibility remains a problem and is highly dependent on the prosthesis type. Even with the addition of PET data, the periprosthetic bone margin could not be reliably assessed in two patients in our study due to severe artefacts. Nevertheless, an important advantage of PET examination is the imaging of the whole body and the detection of possible further foci of infection that may require treatment [31]. The impact of nuclear medicine or hybrid imaging techniques in the evaluation of infections and inflammations is becoming more and more important worldwide. However, there are no studies on PET/MRI in the field of PJI [32, 33].
This study has some limitations. A perfect test would have a sensitivity of 100% and a specificity of 100%. We also obtained these results, but our evaluation is based on a small number of patients, heterogeneous patient population, and limited statistical power. One of the most common causes of PJI is haematogenous spread [34]. Therefore, in patients with suspected PJI, we considered all implanted arthroplasties as potentially infected and included them in the study. Finally, there was no justifiable indication for surgical specimen collection in the three non-painful arthroplasties, so only the result of a puncture with microbiological analysis was evaluated. We did not perform a separate evaluation of the MRI and PET datasets because the MRI data evaluation was limited. In fact, 1.5 T scanners are better suited for examining prostheses and implants. Microbiological evaluation of our cohort revealed that both high-and low-virulence pathogens were detected. Although the number of patients was small for significant statistical analysis, no trend in FDG uptake was observed. This should be verified in a large-scale study.
Conclusion
Simultaneous 18F-FDG-PET/MRI imaging provides a good modality for assessing PJI both functionally and anatomically and reliably in soft tissues. Especially for the functional information derived by 18F-FDG-PET, the pattern of FDG accumulation is more important for diagnosing PJI than the intensity of tracer uptake derived by quantitative SUV measurement. With combined PET/MRI, there were no false-negative results, indicating that combined 18F-FDG PET/MRI may be useful for the exclusion of PJI in patients with persistent painful prostheses and clinically suspected PJI. The hypothesis that PET/MRI provides reliable results of the extent of infection of the individual regions is to be viewed critically in the periprosthetic bone region and bone marrow. However, it remains to be determined whether this gain justifies the high time and cost involved. Further technical improvements in artefact removal and measurement time reduction could be useful for future re-evaluation to assess efficient use in clinical practice.
Data availability
All relevant data generated or analysed during the current study are presented in this paper.
References
Schwartz AM, Farley KX, Guild GN et al (2020) Projections and epidemiology of revision hip and knee arthroplasty in the United States to 2030. J Arthroplasty 35:S79–S85. https://doi.org/10.1016/j.arth.2020.02.030
American Academy of Orthopaedic Surgeons (2020) American Joint Replacement Registry (AJRR): 2020 Annual Report Surgeons (AAOS)
Australian Orthopaedic Association National Joint Replacement Registry (2020) Hip, Knee & Shoulder Arthroplasty: 2020 Annual Report
Grimberg A, Jansson V, Lützner J et al. (2020) EPRD Deutsche Endoprothesenregister: Jahresbericht 2020 (Berlin)
Mundi R, Axelrod DE, Najafabadi BT et al (2020) Early discharge after total hip and knee arthroplasty-an observational cohort study evaluating safety in 330,000 patients. J Arthroplasty 35:3482-3487.e3. https://doi.org/10.1016/j.arth.2020.06.092
Wetters NG, Murray TG, Moric M et al (2013) Risk factors for dislocation after revision total hip arthroplasty. Clin Orthop Relat Res 471:410–416. https://doi.org/10.1007/s11999-012-2561-7
Lum ZC, Natsuhara KM, Shelton TJ et al (2018) Mortality during total knee periprosthetic joint infection. J Arthroplasty 33:3783–3788. https://doi.org/10.1016/j.arth.2018.08.021
Natsuhara KM, Shelton TJ, Meehan JP et al (2019) Mortality during total hip periprosthetic joint infection. J Arthroplasty 34:S337–S342. https://doi.org/10.1016/j.arth.2018.12.024
Thakrar RR, Horriat S, Kayani B et al (2019) Indications for a single-stage exchange arthroplasty for chronic prosthetic joint infection: a systematic review. Bone Joint J 101-B:19–24. https://doi.org/10.1302/0301-620X.101B1.BJJ-2018-0374.R1
Esteban J, Gómez-Barrena E (2021) An update about molecular biology techniques to detect orthopaedic implant-related infections. EFORT Open Rev 6:93–100. https://doi.org/10.1302/2058-5241.6.200118
Rieber H, Frontzek A, Heinrich S et al (2021) Microbiological diagnosis of polymicrobial periprosthetic joint infection revealed superiority of investigated tissue samples compared to sonicate fluid generated from the implant surface. Int J Infect Dis 106:302–307. https://doi.org/10.1016/j.ijid.2021.03.085
Verberne SJ, Sonnega RJA, Temmerman OPP et al (2017) What is the accuracy of nuclear imaging in the assessment of periprosthetic knee infection? A meta-analysis. Clin Orthop Relat Res 475:1395–1410. https://doi.org/10.1007/s11999-016-5218-0
Kim K, Kim SJ (2021) Diagnostic role of PET or PET/CT for prosthetic joint infection: a systematic review and meta-analysis. Hell J Nucl Med 24:83–93. https://doi.org/10.1967/s002449912309
Kwee RM, Kwee TC (2020) 18F-FDG PET for diagnosing infections in prosthetic joints. PET Clin 15:197–205. https://doi.org/10.1016/j.cpet.2019.11.005
Berkowitz JL, Potter HG (2017) Advanced MRI techniques for the hip joint: focus on the postoperative hip. AJR Am J Roentgenol 209:534–543. https://doi.org/10.2214/AJR.16.17789
Gao Z, Jin Y, Chen X et al (2020) Diagnostic value of MRI lamellated hyperintense synovitis in periprosthetic infection of hip. Orthop Surg 12:1941–1946. https://doi.org/10.1111/os.12789
Lee EM, Ibrahim E-SH, Dudek N et al (2021) Improving MR image quality in patients with metallic implants. Radiographics 41:E126–E137. https://doi.org/10.1148/rg.2021200092
Fahnert J, Purz S, Jarvers J-S et al (2016) Use of simultaneous 18F-FDG PET/MRI for the detection of spondylodiskitis. J Nucl Med 57:1396–1401. https://doi.org/10.2967/jnumed.115.171561
Romanò CL, Petrosillo N, Argento G et al (2020) The role of imaging techniques to define a peri-prosthetic hip and knee joint infection: multidisciplinary consensus statements. J Clin Med 9. https://doi.org/10.3390/jcm9082548
Parvizi J, Tan TL, Goswami K et al (2018) The 2018 definition of periprosthetic hip and knee infection: an evidence-based and validated criteria. J Arthroplasty 33:1309-1314.e2. https://doi.org/10.1016/j.arth.2018.02.078
Agten CA, Sutter R, Dora C et al (2017) MR imaging of soft tissue alterations after total hip arthroplasty: comparison of classic surgical approaches. Eur Radiol 27:1312–1321. https://doi.org/10.1007/s00330-016-4455-7
Fritz J, Lurie B, Miller TT et al (2014) MR imaging of hip arthroplasty implants. Radiographics 34:E106–E132. https://doi.org/10.1148/rg.344140010
Galley J, Sutter R, Stern C et al (2020) Diagnosis of periprosthetic hip joint infection using MRI with metal artifact reduction at 1.5 T. Radiology 296:98–108. https://doi.org/10.1148/radiol.2020191901
Cyteval C, Hamm V, Sarrabère MP et al (2002) Painful infection at the site of hip prosthesis: CT imaging. Radiology 224:477–483. https://doi.org/10.1148/radiol.2242010989
Jin H, Yuan L, Li C et al (2014) Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis. Q J Nucl Med Mol Imaging 58:85–93
Zhuang H, Chacko TK, Hickeson M et al (2002) Persistent non-specific FDG uptake on PET imaging following hip arthroplasty. Eur J Nucl Med Mol Imaging 29:1328–1333. https://doi.org/10.1007/s00259-002-0886-2
Basu S, Chryssikos T, Moghadam-Kia S et al (2009) Positron emission tomography as a diagnostic tool in infection: present role and future possibilities. Semin Nucl Med 39:36–51. https://doi.org/10.1053/j.semnuclmed.2008.08.004
Chacko TK, Zhuang H, Stevenson K et al (2002) The importance of the location of fluorodeoxyglucose uptake in periprosthetic infection in painful hip prostheses. Nucl Med Commun 23:851–855. https://doi.org/10.1097/00006231-200209000-00008
van der Bruggen W, Bleeker-Rovers CP, Boerman OC et al (2010) PET and SPECT in osteomyelitis and prosthetic bone and joint infections: a systematic review. Semin Nucl Med 40:3–15. https://doi.org/10.1053/j.semnuclmed.2009.08.005
Molière S, Dillenseger J-P, Ehlinger M et al (2017) Comparative study of fat-suppression techniques for hip arthroplasty MR imaging. Skeletal Radiol 46:1209–1217. https://doi.org/10.1007/s00256-017-2670-1
Roschke E, Kluge T, Stallkamp F et al (2021) Use of PET-CT in diagnostic workup of periprosthetic infection of hip and knee joints: significance in detecting additional infectious focus. Int Orthop. https://doi.org/10.1007/s00264-021-05218-8
Aleksyniene R, Iyer V, Bertelsen HC et al (2022) The role of nuclear medicine imaging with 18F-FDG PET/CT, combined 111In-WBC/99mTc-Nanocoll, and 99mTc-HDP SPECT/CT in the evaluation of patients with chronic problems after TKA or THA in a prospective study. Diagnostics. https://doi.org/10.3390/diagnostics12030681
Casali M, Lauri C, Signore A et al (2021) State of the art of 18F-FDG PET/CT application in inflammation and infection: a guide for image acquisition and interpretation. Clin Transplational Imaging. https://doi.org/10.1007/s40336-021-00445-w
Lenguerrand E, Whitehouse MR, Beswick AD et al (2018) Risk factors associated with revision for prosthetic joint infection after hip replacement: a prospective observational cohort study. Lancet Infect Dis. https://doi.org/10.1016/S1473-3099(18)30345-1
Acknowledgements
The authors are thankful to Torsten Böhm and Susanne Diaz Garza from the Department of Nuclear Medicine, University Hospital Leipzig.
Funding
Open Access funding enabled and organized by Projekt DEAL. The study was funded by a research grant from the Deutsche Arthrose Hilfe e.V.
Author information
Authors and Affiliations
Contributions
All authors contributed to the conception and design of the study. Henkelmann, Henkelmann, and Purz performed material preparation, data collection, measurements, and analysis. The first draft of the manuscript was written by Henkelmann and Henkelmann, and all authors commented on the previous versions of the manuscript. All authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee (Ethics Committee of the Medical Faculty at the University of Leipzig, Germany; 335/17-ek) and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.
Consent to participate
Informed consent was obtained from all individual participants included in the study.
Consent for publication
The authors affirm that human research participants provided informed consent for the publication of the images in Figs. 1 and 2.
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Henkelmann, J., Henkelmann, R., Denecke, T. et al. Simultaneous 18F-FDG-PET/MRI for the detection of periprosthetic joint infections after knee or hip arthroplasty: a prospective feasibility study. International Orthopaedics (SICOT) 46, 1921–1928 (2022). https://doi.org/10.1007/s00264-022-05445-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-022-05445-7