Abstract
Purpose
Obstetric outcomes in women following pelvic injuries requiring surgical fixation is not thoroughly known. We aimed to evaluate if radiographic measurements (RMs) can be used to provide information on delivery methods outcome after these injuries, and to evaluate if metal work removal is required prior to delivery.
Method
A retrospective study in a level 1 trauma centre of female patients with pelvic fractures treated operatively, aged 16–45 at the time of injury. Participants completed a questionnaire regarding their obstetric history. RM evaluating pelvic symmetry, displacement, and pelvimetry were conducted on postoperative radiographs and CT scans. Patients who gave birth after the injury were divided to two groups according to the delivery method: vaginal delivery (VD) and caesarean section (CS). These two groups RM were compared.
Results
Forty-four patients were included, comparison of the RM of patients who delivered by CS (9) and patients who had only VD (11) showed no significant difference between the groups. Two patients underwent a trial of VD who subsequently underwent urgent CS due to prolonged labour, their RM were below the average and their pelvimetry measurements were above the cut-off for CS recommendation. Eleven patients had uncomplicated VD, all had retained sacroiliac screws at the time of delivery and one patient had an anterior pubic plate.
Conclusion
Postoperative RM did not show an effect on delivery method of women after pelvic fracture fixation. A relatively high number of patients who underwent normal vaginal delivery had retained sacroiliac screws. These findings can form the foundation for larger cohort studies.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Pelvic fractures sustained at young ages can be complex injuries associated with marked morbidity [1, 2]. Moreover, young females who are of childbearing age with pelvic fractures can have subsequent obstetric concerns [3, 4].
Normally, the physiological process of pregnancy and labour is associated with pelvis widening and reshaping to accommodate the foetus [5, 6]. For women who sustained a severe pelvic injury, this normal pelvic expansion and movement can be altered. The degree of displacement and asymmetry of the pelvis and the retained hardware could theoretically be an obstacle to normal vaginal delivery by reducing the normal pelvic birth canal diameter.
There is a paucity in literature investigating obstetric outcomes of women post pelvic fractures. Furthermore, many of the patients presented in previous studies are those who were treated non-operatively [7,8,9,10]. Reported caesarean section (CS) rates after pelvic fractures are higher than the population norm [9]; this includes a large registry from Scandinavia which was recently published [11]. The reason for the high rate of CS is unknown. It can be assumed that the lack of literature regarding the safety of vaginal delivery after pelvic injury may influence patients and obstetricians to prefer an elective CS.
In obstetrics, pelvimetry is routinely used to predict and assess feasibility for vaginal delivery [12]. There are acceptable pelvimetry radiographic measurements ranges that are used for recommendation of caesarean section delivery method [13]. To date, these measurements were not recorded as a quantitative tool to assist patients and care givers in the decision of delivery method after severe pelvic fractures. In addition to pelvimetry, there are orthopaedic radiographic measurements that evaluate the degree of displacement after pelvic injury and surgery which provide radiographic quantitative measurements [14].
The primary objective of this study was to evaluate the obstetric outcomes in women of childbearing age following severe pelvic injury who underwent surgical fixation. Secondary aims were to investigate if radiographic measurements can be used to provide information for recommendation of delivery method after these injuries, and if metal work requires removal prior to delivery.
Patients and methods
Following acquisition of Institutional Review Board approval, data regarding young women of childbearing age (16–45 at time of injury) with severe pelvic ring injuries, treated at a single level 1 trauma centre between the years 2009 and 2019, were obtained. Inclusion criteria were female patients diagnosed with pelvic fracture who were treated operatively and had comprehensive postoperative obstetric history records (patient questionnaires and electronic data reports).
Operatively treated females were identified retrospectively through hospital electronic records. Participants were contacted by mail and emails to complete a questionnaire to evaluate data regarding obstetric related concerns, pregnancy rates and delivery methods (Appendix 1). This questionnaire was based on previously designed questionnaires in similar studies [7, 10]. In addition, obstetric data concerning birth rate, delivery methods and pregnancy or delivery-related complications were collected by the electronic regional medical database.
During the pre-specified study period, eighty-one female patients were treated operatively for an acute pelvic injury. However, comprehensive postoperative obstetric history (patient questionnaires and electronic data reports) was available for 44 patients. This patient cohort group formed the basis of the study. Table 1 summarises data regarding demographics, associated injuries, mechanism of injury and fixation modality for these patients, which were obtained from the hospital electronic data base.
Pelvic fracture classification was done by two of the authors, using the institutional Picture Archiving and Communication System (PACS); patients’ radiographs and computed tomography (CT) scan upon arrival were analysed. Fractures were classified according to Young Burgess and AO/OTA classifications [15]. When inconsistency between the assessors was found, the radiographs were re-evaluated until a consensus regarding the classification was reached.
Fixation quality was evaluated by postoperative radiographs anteroposterior (AP), inlet and outlet pelvic views. These radiographic measurements were conducted on the most recent radiographs available with a minimal time of 12 months after the injury. The measurements were calibrated using the screw size inner diameter calibration methods [16]. Vertical displacement was measured as described by Henderson et al. [17]. Pelvic symmetry was evaluated on AP radiographs according to Lefaivre et al. [18], and illustrations of these measurements are shown in Fig. 1. Pelvimetry measurements were performed on the same postoperative radiographs according to Colcher-Sussman technique [19]. Description of the pelvimetry measurements and illustrations are shown in Fig. 2. For the pelvimetry measurements described by Colcher-Sussman on the lateral projection, modified measurements using post operative inlet radiographs were obtained, as lateral radiographs are not routinely used in our daily practice.
In case a CT scan was performed 12 months or more after the initial injury, CT-based pelvimetry measurements were obtained rather than plain radiographs, due to superior reproducibility and accuracy shown in CT-based measurements [20]. Postoperative scans were performed on multidetector computed tomography (MDCT) scanners using helical acquisition and reconstructed in 1 mm slices. Three-dimensional (3D) volume rendering was performed using IMPAX Volume Viewing software, 4.0; Clinapps 7.0.282.0; Agfa Healthcare, Belgium. The CT measurements were based on the technique described by Kaufmann et al. [21]. Measurements were obtained on volume rendered images (3D reconstruction). Similar to the plain radiographs, 4 measurements were obtained. Description of these measurements and illustrations are shown in Fig. 3.
Patients who gave birth after the injury were divided to two groups according to the delivery method: vaginal delivery (VD) group and caesarean section (CS) group. Reduction quality measurements and pelvimetry measurements were compared for these two groups. The general pelvimetry cut-off measurements used in this study as recommendation for CS include TID < 115, ISD < 90, APD < 115, APD + TID < 220 [13].
Data was analysed using SPSS software. Categorial adjustment variables were analysed by chi-squared test. Continuous variables were analysed through Pearson and ANOVA tests. Statistical significance was set at a p value of ≤0.05. For the sample size power analysis two-sided confidence interval of 95% (1-α) and power (1-β) of 80% fora similar group characteristics was applied.
Results
We found twenty-one patients who had full records of post injury pregnancies sustaining severe pelvic injury which were treated surgically. Eleven patients delivered by VD and 9 had CS; one patient had an early spontaneous abortion (week 11) and did not have additional pregnancies. Postoperative obstetrics data including number of pregnancies, delivery method, abortions and failed vaginal delivery attempts are presented in Table 2. Two patients underwent a trial of VD who subsequently required urgent CS due to prolonged labour. All other CS deliveries were planned following joint decision making between the treating obstetrician and patient. Regarding retained hardware during delivery, three of the nine patients who had CS had retained anterior fixation retropubic screws, two patients had pubic plates, eight had sacroiliac screws and 1 had a posterior plate in situ. All the eleven patients in the VD group had retained sacroiliac screws at the time of delivery and one patient had anterior pubic plate. For the patients with failed vaginal delivery attempt, one patient had removal of hardware due to malposition of a screw before her delivery and the other had one sacroiliac screw retained.
Comparison of the radiographic measurements, including pelvimetry and postoperative reduction measurements, of patients who delivered by CS (9) and patients who had only vaginal delivery (11) is presented in Table 3. No significant difference was found in the radiographic measurements of these two groups. The radiographic measurements of the two patients that delivered by emergency CS were unexceptional, the displacement radiographic measurements were below the cohort average and their pelvimetry measurements were above the cut-off for CS recommendation. Radiographic measurements including pelvimetry and postoperative reduction evaluation were obtained on postoperative radiographs with the exception of seven patients for whom a postoperative CT scan was available. Results of the hole study cohort (44 patients) radiographic measurements including mean, range and standard deviation for each variable are presented in Table 4.
The most common stated reason by the patients for the CS delivery was a recommendation by the obstetrician (4 patients), whereas in three patients, it was their own preference; two patients had expressed other obstetric concerns not related to the pelvic injury as a reason for their CS. None of these patients had CS delivery before the injury. Fifty-three percent of the patients who completed the questionnaire stated that they were ‘afraid’ of becoming pregnant following their injury.
Discussion
This is the first study that uses pelvimetry measurement to evaluate obstetric outcomes for women who sustained severe pelvic injury. Our goal was to provide the methodology how to obtain parameters to support recommendations for delivery method after these injuries. Our results did not show a clear correlation between delivery methods and the radiographic measurements, neither in pelvimetry nor in the postoperative displacement measurements. We report on a relative high number of patients who underwent uneventful VD after pelvic fixation with retained hardware.
Our study is limited by a small sample size, although the number of women with deliveries after pelvic surgical fixation we present is the highest published to date. Furthermore, information related to the injury and subsequent care was retrospectively collected, and the obstetric history was obtained by questionnaires and could have recall bias. We could not directly contact the treating obstetricians of patients in the cohort but used electronic hospital records to collect obstetric data in addition to data collected by the questionnaires. Despite these limitations, this study provides data regarding obstetrics outcome after severe pelvic injury and offers a methodology that could be used to obtain radiographic measurements for these patients.
Pelvic fractures in young age usually occur following high energy trauma and are associated with long-term morbidity on patient’s functional status and quality of life [22]. Surgical indications are based on fracture displacement, associated injuries and patient functional status. In young patients, restoration of pelvic symmetry and fracture reduction quality improved patients functional outcome [1]. Surgical indications for minimally displaced fractures are less clear [23, 24]. Surgical treatment should be considered carefully as these surgeries often have major complication [25]. In young woman, additional factors regarding future obstetrics concerns should be considered when making treatment decisions. The effect of asymmetrical pelvis on future pregnancies and the effect of retained hardware on pelvic expansion are not thoroughly known [26].
CS rates after pelvic injury and especially after pelvic fixation are higher than the population norm ranging from 9 to 88% [9]. In our study, we had 43% (9/21) of patients who delivered by CS which is higher than the local population norm which stands at 32.8% [27]. As previously mentioned, a recent study from a Scandinavian registry showed higher CS rate also ten years following the original injury [11]. We believe like previous reports [10, 11] that the high CS rates are related to the lack of consensus and published evidence which will support patients, obstetricians and orthopaedic surgeons in recommending a trial of vaginal delivery. The high percentage of patients (51%) who stated that they are afraid of becoming pregnant after their injury in our questionnaire reflects this point.
Using objective data to support delivery method recommendation can reduce unnecessary CS in women after pelvic injury. Pelvimetry methods have been used for decades for similar purposes [19]. We applied these measurements to our study cohort. Our results did not show a clear correlation between delivery methods and the radiographic measurements when dividing the cohort to patients who delivered by CS and VD. The radiographic measurements of two patients who failed VD attempt in our cohort were in the average range; the reason for the failed delivery attempt cannot be clearly associated to the pelvic displacement and asymmetry. On the contrary, we did show a trend for one of the pelvimetry measurements (ITD) to be lower in the CS group (p value 0.09). Our study cohort is relatively small, and therefore, we recommend further studies to be performed to evaluate the association between radiographic measurements and obstetric outcome.
The postoperative pelvic displacement and symmetry radiographic measurements are an additional subjective measurement tool that should be applied. They provide information regarding pelvic asymmetry which in theory can influence the obstetric outcome and address the unique characteristics of women who sustained severe pelvic injury. Previous study investigating obstetric outcomes after pelvic injury divided patients according to grades of fracture displacement (0–4, 4–10 and above 10 mm of displacement) [10]. Nonetheless, we believe that this method of measurement lacks the ability to assess symmetry and is inaccurate in case there is malalignment in multiple planes.
The influence of retained hardware of pelvic fixation on pregnancy progression and delivery is unknown. There is lack of data especially reporting on VD with retained hardware after pelvic fixation. Vallier et al. [10] reported six patients who had postinjury uneventful VD after surgical fixation; three of these patients had retained trans symphysial plating. Another study reported on four patients having VD after pelvic fixation, but it is unclear if hardware was retained at delivery time [7]. In our study, we report on 11 patients with 16 uneventful vaginal deliveries all with intact hardware. All 11 patients had retained sacroiliac screws; three had bilateral sacroiliac screws and one patient had retained trans symphysial plating. Trans symphyseal plating theoretically could influence progression of vaginal delivery as studies have shown that the pubis symphysis width increases during labour [28]. Despite these concerns, our finding supports previous recommendations that intact pelvic fixation hardware, anterior or posterior is not an indication for CS [9]. One of the patients that failed VD attempt in our cohort had a sacroiliac screw retained at delivery time, although the reason for the failed VD attempt cannot be directly related to retained hardware. Despite our findings, a larger study is needed in order to provide a more solid ground for recommending a trail of vaginal delivery for all cases.
In conclusion, postoperative radiographic measurements did not show an effect on delivery method of women after pelvic fracture fixation. A relatively high number of patients that underwent normal vaginal delivery with retained sacroiliac screws was found. We recommend further studies with a large number of patients to provide a more solid recommendation for these important concerns. We believe that the measurement method presented in this study is accessible and reproducible and can be used for further studies.
Data availability
Raw data were generated from electronical records of the participating medical centre. Derived data supporting the findings of this study are available from the corresponding author [A.D] on request.
References
Papakostidis C, Kanakaris NK, Kontakis G, Giannoudis PV (2009) Pelvic ring disruptions: treatment modalities and analysis of outcomes. Int Orthop 33(2):329–338. https://doi.org/10.1007/s00264-008-0555-6
Wong JM, Bucknill A (2017) Fractures of the pelvic ring. Injury 48(4):795–802. https://doi.org/10.1016/j.injury.2013.11.021
Copeland CE, Bosse MJ, McCarthy ML, MacKenzie EJ, Guzinski GM, Hash CS et al (1997) Effect of trauma and pelvic fracture on female genitourinary, sexual, and reproductive function. J Orthop Trauma 11(2):73–81. https://doi.org/10.1097/00005131-199702000-00001
Harvey-Kelly KF, Kanakaris NK, Obakponovwe O, West RM, Giannoudis PV (2014) Quality of life and sexual function after traumatic pelvic fracture. J Orthop Trauma 28(1):28–35. https://doi.org/10.1097/BOT.0b013e31828fc063
Morino S, Ishihara M, Umezaki F, Hatanaka H, Yamashita M, Aoyama T (2019) Pelvic alignment changes during the perinatal period. PloS One 14(10):e0223776. https://doi.org/10.1371/journal.pone.0223776
Hemmerich A, Bandrowska T, Dumas GA (2019) The effects of squatting while pregnant on pelvic dimensions: a computational simulation to understand childbirth. J Biomech 87:64–74. https://doi.org/10.1371/journal.pone.0223776.10.1016/j.jbiomech.2019.02.017
Cannada LK, Pan P, Casey BM, McIntire DD, Shafi S, Leveno KJ (2010) Pregnancy outcomes after orthopedic trauma. J Trauma Acute Care Surg 69(3):694–698. https://doi.org/10.1097/TA.0b013e3181e97ed8
McCarthy ML, MacKenzie EJ, Bosse MJ, Copeland CE, Hash CS, Burgess AR (1995) Functional status following orthopedic trauma in young women. J Trauma 39(5):828-36; discussion 36-7. https://doi.org/10.1371/journal.pone.0223776.10.1097/00005373-199511000-00005
Riehl JT (2014) Caesarean section rates following pelvic fracture: a systematic review. Injury. 45(10):1516–1521. https://doi.org/10.1371/journal.pone.0223776.10.1016/j.injury.2014.03.018
Vallier HA, Cureton BA, Schubeck D (2012) Pregnancy outcomes after pelvic ring injury. J Orthop Trauma 26(5):302–307. https://doi.org/10.1371/journal.pone.0223776.10.1097/BOT.0b013e31822428c5
Vaajala M, Kuitunen I, Liukkonen R, Ponkilainen V, Kekki M, Mattila VM (2022) The rate of elective cesarean section after pelvic or hip fracture remains high even after the long-term follow-up: a nationwide register-based study in Finland. European Journal of Obstetrics & Gynecology and Reproductive Biology. Oct;277:77-83. https://doi.org/10.1016/j.ejogrb.2022.08.013
Pattinson RC (2000) Pelvimetry for fetal cephalic presentations at term. Cochrane Database Syst Rev 2:Cd000161. https://doi.org/10.1002/14651858.Cd000161
Gabbe SG, Niebyl JR, Simpson JL, Landon MB, Galan HL, Jauniaux ER, Driscoll DA, Berghella V, Grobman WA (2016) Obstetrics: normal and problem pregnancies e-book. Elsevier Health Sciences, pp 270–276
Mataliotakis GI, Giannoudis PV (2011) Radiological measurements for postoperative evaluation of quality of reduction of unstable pelvic ring fractures: advantages and limitations. Injury. 42(12):1395–1401. https://doi.org/10.1016/j.injury.2011.10.012
Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, Prokuski L, Sirkin MS, Ziran B, Henley B, Audigé L (2007) Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21(10 Suppl):S1–133. https://doi.org/10.1097/00005131-200711101-00001
King RJ, Craig PR, Boreham BG, Majeed MA, Moran CG (2009) The magnification of digital radiographs in the trauma patient: implications for templating. Injury 40(2):173–176. https://doi.org/10.1016/j.injury.2008.06.027
Henderson RC (1989) The long-term results of nonoperatively treated major pelvic disruptions. J Orthop Trauma 3(1):41–47. https://doi.org/10.1097/00005131-198903010-00008
Lefaivre KA, Starr AJ, Barker BP, Overturf S, Reinert CM (2009) Early experience with reduction of displaced disruption of the pelvic ring using a pelvic reduction frame. J Bone Joint Surg Br 91(9):1201–1207. https://doi.org/10.1302/0301-620x.91b9.22093
Ross JW, Nickens OJ (1952) The use of x-ray in obstetrics. J Natl Med Assoc 44(2):113–118
Lenhard M, Johnson T, Weckbach S, Nikolaou K, Friese K, Hasbargen U (2009) Three-dimensional pelvimetry by computed tomography. Radiol Med 114(5):827–834. https://doi.org/10.1007/s11547-009-0390-x
Kaufmann D, Lauscher JC, Gröne J, Zur Hausen G, Kreis ME, Hamm B et al (2017) CT-based measurement of the inner pelvic volume. Acta Radiol 58(2):218–223. https://doi.org/10.1177/0284185116637248
Banierink H, Ten Duis K, Wendt K, Heineman E, F IJ, Reininga I. (2020) Patient-reported physical functioning and quality of life after pelvic ring injury: a systematic review of the literature. PloS One 15(7):e0233226. https://doi.org/10.1371/journal.pone.0233226
Gaski GE, Manson TT, Castillo RC, Slobogean GP, OʼToole RV. (2014) Nonoperative treatment of intermediate severity lateral compression type 1 pelvic ring injuries with minimally displaced complete sacral fracture. J Orthop Trauma 28(12):674–680. https://doi.org/10.1097/bot.0000000000000130
Parry JA, Salameh M, Funk A, Heare A, Stacey SC, Mauffrey C (2021) Mobilization versus displacement on lateral stress radiographs for determining operative fixation of minimally displaced lateral compression type I (LC1) pelvic ring injuries. Int Orthop 45(6):1625–1631. https://doi.org/10.1007/s00264-020-04912-3
Salášek M, Český R, Whitley A, Šídlo K, Klézl P, Džupa V (2023) Surgical site infections after stabilization of pelvic ring injuries: a retrospective analysis of risk factors and a meta-analysis of similar studies. Int Orthop 47(5):1331–1344. https://doi.org/10.1007/s00264-023-05719-8
Vallier HA, Cureton BA, Schubeck D, Wang XF (2012) Functional outcomes in women after high-energy pelvic ring injury. J Orthop Trauma 26(5):296–301. https://doi.org/10.1097/BOT.0b013e318221e94e
Digital N. NHS Maternity Statistics, England - 2020-212022. https://digital.nhs.uk/data-and-information/publications/statistical/nhs-maternity-statistics/2020-21. Accessed 10 May 2023
Rustamova S, Predanic M, Sumersille M, Cohen WR (2009) Changes in symphysis pubis width during labor. J Perinat Med 37(4):370–373. https://doi.org/10.1515/jpm.2009.051
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. All authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval
This research study was conducted retrospectively from data obtained for clinical purposes and have approval by the hospital IRB team (research number LOC0141).
Consent to participate
This is a retrospective anonymized data collecting data on patients treated for a common injury, the identity of the patients cannot be revealed. The ethic committee of the participating canter exempt this study form the need to obtain consent to participate.
Consent for publication
In this study, there is an X-ray image of few of the patients from the study cohort. These images purpose is to describe and visualize the paper subject. The X-ray images are anonymized, and there is no concerns that the identity of this patient would be revelled. Following the Journal instructions, there is no need in this case to perform informed consent from this specific patient.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
ESM 1
(DOCX 16 kb)
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Davidson, A., Giannoudis, V.P., Kotsarinis, G. et al. Unstable pelvic fractures in women: implications on obstetric outcome. International Orthopaedics (SICOT) 48, 235–241 (2024). https://doi.org/10.1007/s00264-023-05979-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-023-05979-4