Abstract
Purpose
To evaluate the utility of intraocular lens (IOL) power calculation using adjusted conventional keratometry (K) according to postoperative posterior to preoperative anterior corneal curvature radii (PPPA) ratio for eyes with Fuch’s dystrophy undergoing cataract surgery combined with Descemet membrane endothelial keratoplasty (triple DMEK).
Methods
A fictitious refractive index (FRI) was determined (Pentacam HR®) based on the PPPA ratio in 50 eyes undergoing triple DMEK. Adjusted corneal power was calculated in every eye using adjusted K values: K values determined by the IOLMaster were converted to adjusted anterior corneal radius using the mean FRI. Posterior corneal radius was calculated using the mean PPPA ratio. Adjusted corneal power was determined based on the calculated corneal radii and thick lens formula. Refractive errors calculated using the Haigis, SRK/T, and HofferQ formulae based on the adjusted corneal power were compared with those based on conventional K measurements.
Results
Calculated PPPA ratio and FRI were 0.801 and 1.3271. Mean prediction error based on conventional K was in the hyperopic direction (Haigis: 0.84D; SRK/T: 0.74D; HofferQ: 0.74D) and significantly higher (P < 0.001) than that based on adjusted corneal power (0.18D, 0.22D, and 15D, respectively).
When calculated according to adjusted corneal power, the percentage of eyes with a hyperopic shift > 0.5D fell significantly from 64 to 30% (Haigis), 62 to 36% (SRK/T), and 58 to 26% (HofferQ), respectively.
Conclusion
IOL power calculation based on adjusted corneal power can be used to reduce the risk of a hyperopic shift after triple DMEK and provides a more accurate refractive outcome than IOL power calculation using conventional K.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Descemet membrane endothelial keratoplasty (DMEK) is frequently used for the surgical treatment of endothelial diseases, such as Fuch’s endothelial corneal dystrophy (FECD) [1]. Posterior lamellar keratoplasty has prevailed over penetrating keratoplasty due to faster visual rehabilitation, a lower risk of graft failure and improved safety profile [2, 3]. DMEK can also be safely performed simultaneously with phacoemulsification and intraocular lens (IOL) implantation in patients with clinically significant cataract (triple DMEK) [4].
There are two main problems concerning the postoperative refractive outcome after triple DMEK.
First, several studies report an average postoperative hyperopic shift of approximately + 0.5 to + 1.0 diopters (D) after triple DMEK [4,5,6,7,8]. To counteract this, surgeons aim for a more myopic target refraction of − 0.5D to − 1.0D [4,5,6]. Second, despite this adjustment, patient-individual variations in the postoperative refractive outcome ranging from hyperopia to myopia are observed [6, 8]. Attempts have therefore been made to estimate the degree of the hyperopic shift after triple DMEK in every patient on the basis of preoperative corneal parameters and to take these into account when selecting the target refraction [6, 9]. However, no attempt has been made so far to optimize the erroneous IOL power calculation in eyes with Fuch’s dystrophy undergoing triple DMEK.
The four potential errors of IOL power calculation lie in corneal curvature measurement, axial length (AL) measurement, effective lens position (ELP) estimation, and the calculation formula used [10,11,12]. In the eyes undergoing triple DMEK, IOL power calculation using conventional keratometry (K) to measure corneal power is invalid [13], due to a steeper posterior corneal curvature in eyes after DMEK compared to healthy eyes [13,14,15]. The aim of this study was to evaluate and optimize IOL power calculation using adjusted keratometry values based on the postoperative posterior to preoperative anterior corneal curvature radii (PPPA) ratio [13] for the eyes with Fuch’s endothelial corneal dystrophy undergoing triple DMEK.
Patients and methods
This retrospective study was approved by the local institutional review board (Ethics Committee of the WWU Muenster, Germany) and adhered to the tenets of the Declaration of Helsinki.
Fifty eyes of fourty-two patients with Fuch’s dystrophy who underwent uncomplicated phacoemulsification combined with Descemet membrane endothelial keratoplasty in the Department of Ophthalmology of the University Hospital of Muenster were included in this study.
Eyes with a history of other corneal diseases, corneal infection or intraocular inflammation, trauma, corneal scars, contact lens worn 4 weeks before measurement, clinically significant graft detachment, or delayed corneal clearance were excluded.
Surgical procedure
On the preoperative day, a Nd:YAG iridotomy was performed at six o’clock positions. We obtained corneas from the cornea bank as corneoscleral disks and grafts were stored in commercially available organ culture media (Biochrom, Berlin, Germany). Grafts were prepared using the technique of stripping from the trabecular meshwork [16, 17]. After uneventful cataract surgery the 8.75–9.00-mm donor Descemet roll was stained with a 0.06% trypan blue solution (Vision Blue, D.O.R.C. International) and sucked in to a glass injector (DMEK-Inserter, Geuder, Germany) for injection into the anterior chamber. To position the graft onto the recipient posterior stroma, air or gas (SF6 20%) was injected underneath the graft. After surgery, patients were asked to maintain a supine position for at least 4 h.
IOL power calculation with conventional keratometry
A partial coherence interferometry (PCI) device (IOL Master 500; version 7.3; Carl Zeiss Meditec, Jena, Germany) was used for measurement of AL, ACD, and anterior corneal radii. Conversion of corneal radii to power was performed with a keratometric index of 1.3320. Surgeons aimed for a target refraction ranging between − 0.5 and − 1.0 D (Haigis: − 0.69 D ± 0.38; SRK/T: − 0.59 D ± 0.42; HofferQ: − 0.59 D ± 0.36). Postoperative refraction was measured once after refractive stability had returned (a minimum of 3 months after surgery) [18].
IOL power calculation with adjusted keratometry
Calculation of the IOL power and predicted refraction was performed with adjusted keratometry values using the Haigis, SRK/T, and HofferQ formulae. Conventional keratometry was adjusted using the PPPA ratio and FRI based on pre- and postoperative measurements.
A detailed way to calculate adjusted keratometry based on the PPPA ratio and FRI can be found in Supplementary files 1 and 2.
Refractive prediction error
The median absolute error (MedAE) was defined as the median absolute value of the refractive prediction error. The mean absolute error (MAE) was defined as the mean absolute value of the refractive prediction error. The refractive prediction error (PE) was defined as the difference between the postoperative refractive spherical equivalent and the preoperative predicted refraction determined using the Haigis, SRK/T, and HofferQ formulae with conventional keratometry and adjusted keratometry dependent on the power of the implanted IOL.
Furthermore, we calculated the MedAE, MAE, and PE after subtracting the hyperopic shift which was anticipated by the surgeon as seen in Table 2, which is referred to as conventional keratometry modified. To calculate this, the target refraction chosen by the surgeon is subtracted from the postoperative spherical equivalent.
Statistics
Microsoft Excel 2010 was used for data management. Statistical analyses were performed with IBM SPSS® Statistics 22 for Windows (IBM Corporation, Somers, NY, USA). The normality of the data distribution was tested using the Kolmogorov–Smirnov test. Depending on the normality distribution, data were compared using the paired t-test or two-sided Wilcoxon signed-rank test. An exact chi-quadrat test was used to test differences between categorical variables. The data are presented as mean ± standard deviation (SD). The median absolute error (MedAE) values are presented as median [25, 75 percentiles]. Interferential statistics are intended to be exploratory (hypotheses-generating), not confirmatory, and are interpreted accordingly. The comparison-wise type-I error rate is controlled instead of the experiment-wise error rate. The local significance level was set at P ≤ 0.05.
Results
Postoperative measurements were performed 12 months after surgery in average. The demographic data of the study population are shown in Table 1. The mean prediction error (PE) based on conventional keratometry (42.86 ± 1.72 D) was in the hyperopic direction (Haigis: 0.84 D, SRK/T: 0.74 D, HofferQ: 0.74 D).
Adjusted keratometry values
The Pentacam HR® values required for the calculation of adjusted conventional keratometry were as follows: anterior corneal radius (RA) flattened (preoperative: 7.81 ± 0.32 mm, postoperative: 7.88 ± 0.32 mm; P = 0.017), whereas posterior corneal radius (RB) steepened significantly from 7.06 ± 0.71 to 6.26 ± 0.35 mm (P < 0.01), leading to a mean PPPA ratio of 0.801 ± 0.04. With the thick lens formula, the calculated mean FRI of the group of patients studied was 1.3271 ± 0.0001. Using the PPPA ratio and FRI the mean adjusted keratometry was 42.91 ± 1.72 D with an average difference of 0.05 ± 0.01 D between adjusted corneal power and conventional keratometer values.
Refractive outcomes
Using adjusted keratometry the PE was significantly (all P < 0.001) lower than that based on conventional K (Haigis: 0.18 D; SRK/T: 0.22 D; HofferQ: 0.15 D). The median arithmetic error (MedAE) based on conventional keratometry and calculated using the Haigis, SRK/T, and HofferQ formulae (Haigis: 0.78 D; SRK/T: 0.70 D, HofferQ: 0.63 D) was higher than that based on adjusted corneal power (Haigis: 0.67 D, P = 0.003; SRK/T: 0.60, P = 0.02; HofferQ: 0.49 D, P = 0.004).
The percentage of the eyes with a hyperopic shift > 0.5 D calculated with adjusted corneal power was reduced significantly, indeed almost halved from 64%, 62%, and 58% to 30% (P < 0.001), 36% (P < 0.01), and 26% (P < 0.001) with Haigis, SRK/T, and HofferQ, respectively. The refractive outcomes obtained using the Haigis, SRK/T, and HofferQ formulae are summarized in Table 2.
Discussion
A standard IOL power calculation for eyes undergoing cataract surgery combined with DMEK is prone to error. Mean refractive outcomes deviate significantly in the hyperopic direction between + 0.50 and + 1.00 from the planned refraction depending on the study [4,5,6,7,8]. Similarly, in our data, a hyperopic shift with an average of + 0.7 D was present.
IOL power is traditionally calculated from on keratometer readings that estimate the corneal refractive power from anterior corneal measurements alone [19]. This so-called conventional K is used in IOL Master PCI devices and assumes a normal and constant PA ratio in all eyes [19].
In our study, the posterior corneal curvature was found to change significantly after DMEK, a finding in line with results presented in the literature [18, 20, 21]. Therefore, as the posterior corneal curvature is not measured directly but changes significantly after DMEK, the decisive ratio for IOL power calculation prior to triple DMEK is the postoperative posterior (once stable refraction has been achieved) to the preoperative anterior (when conventional K is performed) corneal curvature radii (PPPA) ratio.
However, the PPPA ratio in Fuch’s dystrophy eyes undergoing triple DMEK is significantly different to the PA ratio in healthy eyes and therefore renders conventional K and the corneal power derived from it by this method invalid, as was confirmed in a previous study by our group [13].
Similar results are reported in other studies. Arnalich-Montiel et al. found a thinner central corneal thickness, with a steeper pachymetric progression to the periphery in the eyes after DMEK compared to normal eyes using Scheimpflug imaging [15]. Similarly, Hayashi et al. found a steeper posterior corneal curvature in comparison to healthy controls using optical coherence tomography [14].
Thus, using conventional K for corneal power estimation in eyes undergoing triple DMEK leads to an underestimation of the postoperative (more negative) posterior corneal power and hence an overestimation of the total corneal power and the resulting IOL power is underestimated, so that patients are likely to experience postoperative hyperopia [13].
There are numerous methodologies that aim to overcome the problem of altered PA ratios by modifying the keratometric index [22,23,24]. Kim et al. introduced Eom’s adjustment method [25] in 2018. This method suggests an adjustment of IOL Master K values according to the patient’s individual preoperative PA ratio without changing the mean value of the entire data set. In their method, adjustment of K values is based on the preoperative PA ratio and a fictitious refractive index calculated with a thick lens formula, determined using Scheimpflug imaging (Pentacam HR®) [25].
Similarly, the present study optimizes the IOL calculation in eyes undergoing triple DMEK using adjusted K values.
The proposed method significantly reduced the percentage of patients developing a postoperative hyperopic shift. Furthermore, we significantly improved the refractive prediction accuracy of IOL power calculation by using the Haigis, SRK/T, and HofferQ formulae in eyes undergoing triple DMEK. Also, there is no significant difference of the introduced methodology to the current gold standard of simply choosing the target refraction in between the range of − 0.5 and − 1.0 D as seen in Table 2.
However, the postoperative refractive outcome still ranges from hyperopia to myopia, as seen in Fig. 1, leading to a high standard deviation of the prediction error (± 0.90).
In the present study, this might be explained by a change of the anterior corneal curvature as seen in Fig. 2. Using adjusted keratometry values addresses the problem of the steeper postoperative corneal curvature; however, the problem of patient-individual refractive outcomes due to possible changes of the anterior corneal radius or other causes remains unsolved.
As both corneal and surgical parameters such as descemetorhexis size, Descemet roll size, and both steepness and location of the incision could affect the PPPA ratio, an individualized PPPA ratio may need to be calculated and optimized over time for different surgeons and patients to improve refractive outcome. To calculate a FRI for a specific patient group at risk of a myopic or high hyperopic shift, the larger number of patients is required.
Conclusion
In conclusion, IOL power calculation using adjusted corneal power based on the PPPA ratio might predict postoperative refraction more accurately than that obtained through conventional K in eyes undergoing triple DMEK and reduces the risk of a postoperative hyperopic shift in these eyes. The new methodology is non-inferior to the current gold standard of choosing a target refraction between − 0.5 and − 1.0 D.
References
Melles GR, Lander F, Rietveld FJ (2002) Transplantation of Descemet’s membrane carrying viable endothelium through a small scleral incision. Cornea 21(4):415–418. https://doi.org/10.1097/00003226-200205000-00016
Terry MA, Straiko MD, Veldman PB et al (2015) Standardized DMEK technique: reducing complications using prestripped tissue, novel glass injector, and sulfur hexafluoride (SF6) Gas. Cornea 34(8):845–852. https://doi.org/10.1097/ICO.0000000000000479
van Dijk K, Ham L, Tse WH et al (2013) Near complete visual recovery and refractive stability in modern corneal transplantation: Descemet membrane endothelial keratoplasty (DMEK). Contact Lens Anterior Eye 36(1):13–21. https://doi.org/10.1016/j.clae.2012.10.066
Laaser K, Bachmann BO, Horn FK et al (2012) Descemet membrane endothelial keratoplasty combined with phacoemulsification and intraocular lens implantation: advanced triple procedure. Am J Ophthalmol 154(1):47-55.e2. https://doi.org/10.1016/j.ajo.2012.01.020
Schoenberg ED, Price FW Jr, Miller J et al (2015) Refractive outcomes of Descemet membrane endothelial keratoplasty triple procedures (combined with cataract surgery). J Cataract Refract Surg 41(6):1182–1189. https://doi.org/10.1016/j.jcrs.2014.09.042
Cheung AY, Chachare DY, Eslani M et al (2018) Tomographic changes in eyes with hyperopic shift after triple Descemet membrane endothelial keratoplasty. J Cataract Refract Surg 44(6):738–744. https://doi.org/10.1016/j.jcrs.2018.04.040
Augustin VA, Weller JM, Kruse FE, et al. (2020) Refractive outcomes after descemet membrane endothelial keratoplasty + cataract/intraocular lens triple procedure: a fellow eye comparison. Cornea. https://doi.org/10.1097/ICO.0000000000002602
Bae SS, Ching G, Holland S, et al. (2020) refractive outcomes of descemet membrane endothelial keratoplasty combined with cataract surgery in Fuchs endothelial dystrophy. Journal of refractive surgery (Thorofare, NJ : 1995);36(10):661–6. DOI: https://doi.org/10.3928/1081597X-20200729-02
Fritz M, Grewing V, Böhringer D et al (2019) Avoiding hyperopic surprises after descemet membrane endothelial keratoplasty in Fuchs dystrophy eyes by assessing corneal shape. Am J Ophthalmol 197:1–6. https://doi.org/10.1016/j.ajo.2018.08.052
Wang L, Shirayama M, Ma XJ et al (2011) Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg 37(11):2018–27. https://doi.org/10.1016/j.jcrs.2011.05.042
Cooke DL, Cooke TL (2016) Comparison of 9 intraocular lens power calculation formulas. J Cataract Refract Surg 42(8):1157–1164. https://doi.org/10.1016/j.jcrs.2016.06.029
Melles RB, Holladay JT, Chang WJ (2018) Accuracy of intraocular lens calculation formulas. Ophthalmology 125(2):169–178. https://doi.org/10.1016/j.ophtha.2017.08.027
Diener R, Treder M, Lauermann JL, et al. (2020) Assessing the validity of corneal power estimation using conventional keratometry for intraocular lens power calculation in eyes with Fuch’s dystrophy undergoing Descemet membrane endothelial keratoplasty. Graefes Arch Clin Exp ophthalmol. https://doi.org/10.1007/s00417-020-04998-w
Hayashi T, Kobayashi A, Takahashi H et al (2020) Optical characteristics after Descemet membrane endothelial keratoplasty: 1-year results. PLoS ONE 15(10):e0240458. https://doi.org/10.1371/journal.pone.0240458
Arnalich-Montiel F, Mingo-Botín D, Diaz-Montealegre A (2019) Keratometric, pachymetric, and surface elevation characterization of corneas with Fuchs endothelial corneal dystrophy treated with DMEK. Cornea 38(5):535–541. https://doi.org/10.1097/ICO.0000000000001875
Groeneveld-van Beek EA, Lie JT, van der Wees J et al (2013) Standardized ‘no-touch’ donor tissue preparation for DALK and DMEK: harvesting undamaged anterior and posterior transplants from the same donor cornea. Acta Ophthalmol 91(2):145–150. https://doi.org/10.1111/j.1755-3768.2012.02462.x
Parekh M, Borroni D, Ruzza A et al (2018) A comparative study on different Descemet membrane endothelial keratoplasty graft preparation techniques. Acta Ophthalmol 96(6):e718–e726. https://doi.org/10.1111/aos.13746
Ham L, Dapena I, Moutsouris K et al (2011) Refractive change and stability after Descemet membrane endothelial keratoplasty. Effect of corneal dehydration-induced hyperopic shift on intraocular lens power calculation. Journal of cataract and refractive surgery 37(8):1455–64. https://doi.org/10.1016/j.jcrs.2011.02.033
Olsen T (1986) On the calculation of power from curvature of the cornea. Br J Ophthalmol 70(2):152–154. https://doi.org/10.1136/bjo.70.2.152
Alnawaiseh M, Rosentreter A, Eter N et al (2016) Changes in corneal refractive power for patients with Fuchs endothelial dystrophy after DMEK. Cornea 35(8):1073–1077. https://doi.org/10.1097/ICO.0000000000000842
Diener R, Eter N, Alnawaiseh M. (2020) [Change of corneal radii after Descemet membrane endothelial keratoplasty measured by optical coherence tomography and Scheimpflug tomography]. Der Ophthalmologe: Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. https://doi.org/10.1007/s00347-020-01289-x
Hamilton DR, Hardten DR (2003) Cataract surgery in patients with prior refractive surgery. Curr Opin Ophthalmol 14(1):44–53. https://doi.org/10.1097/00055735-200302000-00008
Masket S, Masket SE (2006) Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32(3):430–434. https://doi.org/10.1016/j.jcrs.2005.12.106
Savini G, Barboni P, Carbonelli M et al (2013) Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera. J Cataract Refract Surg 39(4):598–604. https://doi.org/10.1016/j.jcrs.2012.11.022
Kim M, Eom Y, Lee H et al (2018) Use of the posterior/anterior corneal curvature radii ratio to improve the accuracy of intraocular lens power calculation: Eom’s adjustment method. Invest Ophthalmol Vis Sci 59(2):1016–1024. https://doi.org/10.1167/iovs.17-22405
Funding
Open Access funding enabled and organized by Projekt DEAL.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethics approval
All procedures in studies involving human participants were performed in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.
Consent to participate
This retrospective study was approved by the local Institutional Review Board (Ethics Committee of the WWU Muenster, Germany).
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Diener, R., Treder, M., Lauermann, J.L. et al. Optimizing intraocular lens power calculation using adjusted conventional keratometry for cataract surgery combined with Descemet membrane endothelial keratoplasty. Graefes Arch Clin Exp Ophthalmol 260, 3087–3093 (2022). https://doi.org/10.1007/s00417-022-05598-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00417-022-05598-6