Abstract
Background
Accurate identification of tumor sites during laparoscopic colorectal surgery helps to optimize oncological clearance. We aimed to assess the timing of the local injection preoperatively and clarify the usefulness and limitation of tumor site marking using indocyanine green (ICG) fluorescence imaging.
Methods
Consecutive patients who underwent primary colorectal cancer surgery from September 2017 to January 2019 were included. Preoperatively, lower endoscopy was used to inject the ICG solution into the submucosal layer near the tumor. During laparoscopic surgery, ICG fluorescence marking as the tumor site marking was detected using a laparoscopic near-infrared camera system. The detection rate and factors associated with successful intraoperative ICG fluorescence visualization including the interval between local injection and surgery were evaluated.
Results
One hundred sixty-five patients were enrolled. Using the laparoscopic near-infrared system, the intraoperative detection rates of ICG marking were 100% for ICG injection within 6 days preoperatively, 60% for injection between 7 and 9 days preoperatively, and 0% for injection earlier than 10 days preoperatively. There were no complications associated with ICG marking. Additionally, this method did not disturb the progress of the surgical procedure because injected ICG in the submucosal layer did not cause any tissue inflammation, and if ICG spilled into the serosa, it was invisible by white light.
Conclusion
Advantages of ICG fluorescence tumor site marking were high visibility of infrared imaging during laparoscopic colorectal surgery and minimal adverse events of surgery. One of the most important findings regarding practical use was a rapid decrease in fluorescence marking visibility if one week passed from the time of ICG local injection.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Indocyanine green (ICG) has been used as an intraoperative navigation agent in several diseases [1, 2]. There have been some reports that tumor sites marking using ICG for colorectal cancer surgery has high visibility [3, 4], but the usefulness and features of ICG in clinical practice need to be clarified in detail in order for it to be widely used. Surgical approaches and the necessary resection margins in colorectal cancer are determined by the tumor sites, so accurate identification of tumor sites is important for maximizing oncological clearance and functional sparing.
To identify the tumor site during surgery, intraoperative colonoscopy may be necessary in some cases, but it can be resource-dependent and can cause colonic distension if not performed properly.
India ink tattooing has been conventionally used for tumor marking in colon cancer surgery. This technique was first described in 1976 by Ponsky and King [5]. Two studies reported that India ink tattooing was useful and safe for marking tumors in the colon [6, 7]. However, adverse effects caused by India ink tattooing have been observed; for instance, if India ink spreads widely throughout the peritoneal cavity, it can cause problems such as inflammation, focal peritonitis, inflammatory pseudotumors, abscesses, and adhesions [8,9,10]. Because India ink is a permanent tattooing method, it cannot be eliminated if it spills out of the serosa, which could be a major disadvantage when proceeding with laparoscopic surgery. Therefore, we need a novel agent characterized by lower rates of inflammatory reactions when in contact with the serosa, less visibility in white light, and lower surgical view interference rates.
In 1993, a study first described the use of ICG as a colonic marking agent instead of India ink, which was used with white light in open and laparoscopic surgery [11]. Then, ICG fluorescence imaging as the tumor site marking in near-infrared fluorescence was reported to be feasible and safe following local injection with endoscopy [3]; however, it has several unknowns. ICG is metabolized and excreted in vivo, but the timing of local ICG injection for marking purposes has been unclear when using near-infrared light. The interval from local ICG injection to surgery is also related to the number of endoscopies and the burden on the patient; therefore these factors should be considered over the long term. Another problem is that it is visualized with near-infrared light unlike India ink. The impact of these features on surgery is worth considering. If ICG spills into tissue, it is unclear whether it will disturb the surgical field or cause tissue inflammation like India ink, and this should be clarified. Therefore, in this study, we evaluated the detection rate of ICG fluorescence markings with near-infrared light in a relatively large number of patients and aimed to clarify the usefulness and limitation of it in laparoscopic colorectal surgery.
Patients and methods
Study population
From September 2017 to January 2019, consecutive patients scheduled to undergo laparoscopic colorectal resection in Sapporo Medical University Hospital were enrolled. Eligible patients were 20 years or older with histopathologically proven colorectal cancer, had an Eastern Cooperative Oncology Group performance status of 0–2, and provided informed consent. Patients were excluded if they had iodine hypersensitivity.
Ethical statements
This study was approved by the Institutional Review Board of Sapporo Medical University, and patients who understood and agreed with the explanation of the research study were enrolled. Informed consent was obtained from all participants.
This clinical trial was registered in the University Hospital Medical Information Network (UMIN) Center (ID: UMIN000038982).
Study procedure
In order to use ICG fluorescence imaging to detect the tumor site during surgery, we injected an ICG solution preoperatively into the submucosal layer at two points around the tumor using a colonoscope (Fig. 1A, B). The timing for the colonoscopy depended on the surgeon and the patient, and the change in the detection rate of ICG marking due to the interval between endoscopic marking and the operation was examined. During preoperative colonoscopy, a stock solution of ICG (Diagnogreen; Dai-Ichi Pharmaceuticals, Tokyo, Japan) was prepared by dissolving 25 mg of powdered ICG in 5 ml of sterilized water. Using a 26-gauge needle, 0.2 ml of a normal saline solution was injected into the submucosal layer to form submucosal elevation at two sites on the colonic wall opposite the tumor. Then 0.1 cc of ICG solution was injected into the elevated areas. The assistant pushed the dose accurately using a 1 ml syringe for tuberculin local injection. The local injection volume was set as the minimum volume that could be technically injected without problems. As a result of preliminary experiments, it was confirmed that fluorescence observation was possible with ICG doses between 0.125 and 2 mg. We set the dose at 0.5 mg, which was the median value and easily implicated in clinical practice. During the laparoscopic operation, ICG fluorescence marking was conducted using a laparoscopic near-infrared camera system (1588/1688 AIM laparoscope; Stryker, San Jose, CA, USA; DaVinci operation robot system; Intuitive Surgical, Mountain View, CA, USA). In this study, the detections were judged as positive if ICG fluorescence could be visualized as tumor site markings at the time of bowel resection. The detection rate was defined as the proportion of patients in whom the ICG fluorescence marking was observed during surgery by the operator.
Primary and secondary endpoints
The primary endpoint was the intraoperative detection rate of ICG markings. Secondary endpoints were the appropriate timing of the ICG local injection, and the safety of the method was determined by evaluating the rates of complications and allergic events. The positive detection of ICG fluorescence was defined as whether ICG fluorescence could be used clinically as tumor site identification based on the operator’s judgement.
Statistical analysis
The data are presented as mean and standard deviation or as median and range. Statistical analyses were performed using the statistical software program EZR (Easy R), which is based on R and R commander, and freely available (https://www.jichi.ac.jp/saitama-sct/SaitamaHP.files/statmed.html).
Results
Patient characteristics
One hundred sixty-five consecutive patients were enrolled in this study. All patients underwent laparoscopic surgery. The patient and tumor characteristics are presented in Table 1. All procedures were performed safely, with no complications, allergic events, or conversion to open surgery.
Detection of ICG fluorescence marking
The markings using ICG fluorescence imaging were visualized with a near-infrared camera during laparoscopic surgery (Fig. 2A–D). The detection rates of intraoperative ICG fluorescence marking and the intervals between endoscopic marking and the subsequent operation are shown in Fig. 3. The detection rates rapidly decreased when more than 7 days has elapsed since the ICG injection. In all 141 patients who underwent ICG marking within 6 days, ICG fluorescence marking was detected with the near-infrared camera. ICG fluorescence marking was visualized in 6 of 10 patients (60%) who were marked between 7 and 9 days before surgery and in none of the four patients (0%) who were marked more than 10 days before surgery. The detection rates of ICG fluorescence were significantly different between these three groups (p < 0.0001, Fisher’s exact test).
Complications
No patients experienced preoperative adverse events caused by local injection of ICG, such as fever or abdominal pain. Additionally, no patient had an allergic reaction to ICG. During intraoperative observation, ICG did not form an intraabdominal abscess in any case. In some cases, ICG fluorescence marking spilled into the serosa, spread widely, and obscured the separation boundary in the near-infrared view, but it did not disturb the surgical field in the white light view (Fig. 4A, B). In some cases, intraabdominal adhesions were observed, but their direct relationship with the ICG injection was not proven. Pathological examination in the case of a patient with peritoneal adhesion showed only mild tissue changes and no increase in the number of inflammatory cells in the submucosal layer into which ICG was locally injected; additionally, there was no spread of inflammation in the serosa where the adhesion occurred (Fig. 5A, B). ICG fluorescence microscopy of the same slice showed that the ICG molecules were distributed and fluoresced in the tissue of the submucosa and were not present outside the proper muscle layer (Fig. 5C). The same microscopic findings were observed in another case which did not cause intraabdominal adhesions.
Discussion
This study showed that observation of ICG fluorescence marking with near-infrared light is a reliable method for tumor site marking if ICG is injected into the submucosal layer around the tumor within 6 days before laparoscopic colorectal surgery. Another finding was that the ICG substance maintained in the tissue of the submucosa and excitation wavelength penetrated the outer layer, so that ICG marking would not cause inflammatory cell migration outside the bowel wall. In addition, even if it has spilled into the serosa, it did not disturb the surgical field in the white light view. We clarified the usefulness of ICG fluorescence imaging for tumor site marking in laparoscopic colorectal surgery.
The methods of detecting the tumor site during surgery are limited. India ink tattooing was a common tumor site marking method. This process results in permanent markings, which is beneficial, but if it spreads widely outside the serosa, the accuracy of identifying the tumor location is lost. Additionally, the black-stained surgical field makes the operation difficult to complete.
In terms of surgical principle, complete mesocolic excision (CME) for colon cancer and total mesorectal excision (TME) for rectal cancer surgery have been shown to significantly improve outcomes [12,13,14,15,16]. An accurate marking identification using ICG fluorescence imaging of the tumor site during surgery would be useful in both CME and TME. Therefore, ICG marking was suggested to be one of the techniques to improve the prognosis of colorectal cancer surgery.
In a previous study of ICG use for tumor site marking, 1 ml (ICG dose: 12.5 mg) of ICG suspension was injected into the mucosal layer. The positivity of staining and interval between ICG marking and surgery were assessed in detail by observation in the visible light spectrum [4]. In our study, the ICG markings were visualized by near-infrared light; thus, their detection was possible with an injection of only 0.1 ml (ICG dose: 0.5 mg) of ICG suspension. The near-infrared fluorescence of ICG has a wavelength of 800–1000 nm and good biopermeability [17]. Therefore, it is considered that even if a small amount of ICG suspension is injected into the submucosal region, the fluorescence of ICG passes through the intestinal wall and can be detected with high reproducibility from outside the serosa. The advantage of using a small injection volume is that it can reduce the risk of expanding the ICG fluorescence area and prevent misidentification of the tumor site. It also reduces the risk of leakage into the peritoneum, which can cause peritonitis and intestinal adhesions.
In a previous study of ICG marking in laparoscopic colorectal surgery, fluorescence induced by near-infrared light enabled surgeons to clearly and accurately identify the tumor location in all 24 patients who were injected with ICG within 96 h before surgery [3]. The details of the correlation between visualization of ICG fluorescence and the timing of the preoperative injection of ICG before surgery are unclear in cases where ICG markings are observed using near-infrared light in laparoscopic colorectal cancer. We assessed tumor site marking in 165 patients who underwent laparoscopic colorectal cancer surgery. Our study results suggest that ICG marking injection should be performed within at least 6 days before surgery. When the injections were performed more than 7 days before surgery, there were cases in which ICG fluorescence could not be visualized, and this incidence increased according with the intervals, presumably because the injected ICG suspension was cleared from the submucosal layer. However, the detailed mechanisms whereby the ICG molecules in the intestinal wall are metabolized and excreted are not yet known. In our study, liver function was not associated with the detection rate of the ICG fluorescence marking. As for the method of the local injection of ICG, the method using the endoscope like in the present study and local injection from outside of the serosa laparoscopically have been reported [18]. The endoscopic approach was considered suitable for marking the tumor site because the endoscope can detect early cancer and scar post local resection. Local injection of ICG into the submucosal tissue near the tumor resulted in fluorescence of the injection site. At the same time, fluorescence associated with lymph nodes and draining lymphatic flow was also observed. One study that assessed fluorescence in lymph node imaging reported that ICG could be safely injected into the peritumoral subserosal area and then subsequently demonstrated lymphatic drainage in those with colon cancer [19]. It is necessary to further examine how the simultaneous observation of ICG markings and ICG fluorescence of lymph nodes affect colorectal cancer resection. In the future we may investigate the pathological mechanisms and their association with fluorescence in lymph nodes.
This study has several limitations. First, adequate local injection into the submucosal layer required an endoscopist with high-level skills. If this technique fails, the accuracy of the tumor site is reduced and microperforation of the bowel can occur, subsequently causing inflammatory reactions. Second, in this study, only the detection rate of the ICG fluorescence marking was evaluated; ICG fluorescence imaging could differ depending on the local injection location. In particular, in some case of rectal cancer, diffuse expanding fluorescence signals of the marking were observed. Therefore, more consideration will be needed with regard to tumor marking location and the quality of tumor identification.
In conclusion, we clarified the usefulness and features of the tumor site marking method using ICG fluorescence imaging in laparoscopic colorectal cancer surgery. ICG fluorescence marking with near-infrared light is a reliable method for tumor site marking if ICG is injected into the submucosal layer around the tumor within 6 days before laparoscopic colorectal surgery.
References
Mieog JS, Troyan SL, Hutteman M, Donohoe KJ, van der Vorst JR, Stockdale A, Liefers GJ, Choi HS, Gibbs-Strauss SL, Putter H, Gioux S, Kuppen PJ, Ashitate Y, Lowik CW, Smit VT, Oketokoun R, Ngo LH, van de Velde CJ, Frangioni JV, Vahrmeijer AL (2011) Toward optimization of imaging system and lymphatic tracer for near-infrared fluorescent sentinel lymph node mapping in breast cancer. Ann Surg Oncol 18:2483–2491
Boni L, Fingerhut A, Marzorati A, Rausei S, Dionigi G, Cassinotti E (2017) Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study. Surg Endosc 31:1836–1840
Nagata J, Fukunaga Y, Akiyoshi T, Konishi T, Fujimoto Y, Nagayama S, Yamamoto N, Ueno M (2016) Colonic marking with near-infrared, light-emitting, diode-activated indocyanine green for laparoscopic colorectal surgery. Dis Colon Rectum 59:e14–18
Miyoshi N, Ohue M, Noura S, Yano M, Sasaki Y, Kishi K, Yamada T, Miyashiro I, Ohigashi H, Iishi H, Ishikawa O, Imaoka S (2009) Surgical usefulness of indocyanine green as an alternative to India ink for endoscopic marking. Surg Endosc 23:347–351
Ponsky JL, King JF (1975) Endoscopic marking of colonic lesions. Gastrointest Endosc 22:42–43
McArthur CS, Roayaie S, Waye JD (1999) Safety of preoperation endoscopic tattoo with india ink for identification of colonic lesions. Surg Endosc 13:397–400
Nizam R, Siddiqi N, Landas SK, Kaplan DS, Holtzapple PG (1996) Colonic tattooing with India ink: benefits, risks, and alternatives. Am J Gastroenterol 91:1804–1808
Coman E, Brandt LJ, Brenner S, Frank M, Sablay B, Bennett B (1991) Fat necrosis and inflammatory pseudotumor due to endoscopic tattooing of the colon with india ink. Gastrointest Endosc 37:65–68
Lane KL, Vallera R, Washington K, Gottfried MR (1996) Endoscopic tattoo agents in the colon. Tissue responses and clinical implications. Am J Surg Pathol 20:1266–1270
Dell'Abate P, Iosca A, Galimberti A, Piccolo P, Soliani P, Foggi E (1999) Endoscopic preoperative colonic tattooing: a clinical and surgical complication. Endoscopy 31:271–273
Hammond DC, Lane FR, Mackeigan JM, Passinault WJ (1993) Endoscopic tattooing of the colon: clinical experience. Am Surg 59:205–210
Heald RJ, Husband EM, Ryall RD (1982) The mesorectum in rectal cancer surgery—the clue to pelvic recurrence? Br J Surg 69:613–616
Martling AL, Holm T, Rutqvist LE, Moran BJ, Heald RJ, Cedemark B (2000) Effect of a surgical training programme on outcome of rectal cancer in the County of Stockholm. Stockholm Colorectal Cancer Study Group, Basingstoke Bowel Cancer Research Project. Lancet (London, England) 356:93–96
Kapiteijn E, Putter H, van de Velde CJ (2002) Impact of the introduction and training of total mesorectal excision on recurrence and survival in rectal cancer in The Netherlands. Br J Surg 89:1142–1149
Wibe A, Moller B, Norstein J, Carlsen E, Wiig JN, Heald RJ, Langmark F, Myrvold HE, Soreide O (2002) A national strategic change in treatment policy for rectal cancer—implementation of total mesorectal excision as routine treatment in Norway. A national audit. Dis Colon Rectum 45:857–866
West NP, Hohenberger W, Weber K, Perrakis A, Finan PJ, Quirke P (2010) Complete mesocolic excision with central vascular ligation produces an oncologically superior specimen compared with standard surgery for carcinoma of the colon. J Clin Oncol 28:272–278
Marshall MV, Rasmussen JC, Tan IC, Aldrich MB, Adams KE, Wang X, Fife CE, Maus EA, Smith LA, Sevick-Muraca EM (2010) Near-infrared fluorescence imaging in humans with indocyanine green: a review and update. Open Surg Oncol J (Online) 2:12–25
Watanabe J, Ota M, Suwa Y, Ishibe A, Masui H, Nagahori K (2017) Evaluation of lymph flow patterns in splenic flexural colon cancers using laparoscopic real-time indocyanine green fluorescence imaging. Int J Colorectal Dis 32:201–207
Chand M, Keller DS, Joshi HM, Devoto L, Rodriguez-Justo M, Cohen R (2018) Feasibility of fluorescence lymph node imaging in colon cancer: FLICC. Tech Coloproctol 22:271–277
Acknowledgements
The authors thank Dr. Hiroo Ymano and Dr. Hiroshi Nakase of Sapporo Medical University for their expert technical assistance in performing the endoscopies.
Funding
This study received no funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Disclosures
Tetsuta Satoyoshi, Kenji Okita, Masayuki Ishii, Atsushi Hamabe, Akihiro Usui, Emi Akizuki, Koichi Okuya, Toshihiko Nishidate, Hiroo Yamano, Hiroshi Nakase, and Ichiro Takemasa have no conflicts of interest or financial ties to disclose.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Satoyoshi, T., Okita, K., Ishii, M. et al. Timing of indocyanine green injection prior to laparoscopic colorectal surgery for tumor localization: a prospective case series. Surg Endosc 35, 763–769 (2021). https://doi.org/10.1007/s00464-020-07443-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-020-07443-5