Abstract
Background
This study aims to report the results of a pioneering clinical study using the single-port transaxillary robotic thyroidectomy (START) for 200 patients with thyroid tumor and to introduce our novel two-step retraction method.
Methods
START was performed on consecutive 200 patients using the da Vinci Single-Port (SP) robot system from January 2019 to September 2020 at the Yonsei University Health System, Seoul, Korea. The novel two-step retraction technique, in which a 3.5 cm long incision is made along the natural skin crease, was used for the latter 164 patients. The surgical outcome and invasiveness of the SP two-step retraction method were analyzed.
Results
Among the 200 cases who underwent START, 198 were female and 2 were male, with a mean age of 34.7 (range: 13–58 years). Thyroid lobectomy was performed for 177 patients and total thyroidectomy was performed for 23 patients. Ten patients had benign thyroid nodules, whereas the other 190 had thyroid malignancy. The mean body mass index (BMI) was 22.2 ± 3.7 kg/m2 (range: 15.9–37.0 kg/m2). All of the operations were performed successfully without any open conversions, and patients were discharged on postoperative day 3 or 4 without significant complication. The mean operative time for thyroid lobectomy with the two-step retraction method was 116.69 ± 23.23 min, which was similar to that in the conventional robotic skin flap method (115.33 ± 17.29 min). We could minimize the extent of the robotic skin flap dissection with the two-step retraction method.
Conclusions
START is a practical surgical method. By employing the new two-step retraction method, we can maximize the cosmetic and functional benefits for patients and reduce the workload fatigue of surgeons by increasing robotic dependency.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Minimally invasive robotic surgeries for thyroid cancer and other thyroid diseases are frequently performed using various methods, such as the transaxillary [1], BABA [2], facelift [3], transoral [4], and retroauricular approaches [5]. Our institution strives to develop safe and feasible transaxillary approaches for thyroid surgeries.[1, 6,7,8,9,10,11,12].
The recently introduced da Vinci SP® Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) provides access to the narrow and deep portions of internal body organs with minimal incision, which is suitable for indolent diseases such as most thyroid tumours including carcinoma [13, 14]. Young patients have high incidence of thyroid carcinoma with extremely low mortality rates [15, 16]; hence, the quality of life of this patient group after surgery is crucial. In order to reduce postoperative pain, adhesion, and scars, our institution introduced the da Vinci SP system.
The difference between the da Vinci SP system and the previous platforms is that this system has a single trocar that delivers three multijointed instruments and a fully wristed three-dimensional high-definition camera, instead of four distinct robotic arms, which reduces collision between the robotic arms in narrow and confined spaces. In this paper, we introduce our novel surgical technique with a two-step method using the da Vinci SP system, which can increase robotic efficiency and minimize invasiveness.
Method
Patients
Single-port transaxillary robotic thyroidectomy (START) was performed on consecutive 200 patients using the da Vinci SP robot system from January 2019 to September 2020. Among them, 36 patients underwent robotic thyroidectomy involving a conventional robotic skin flap method (conventional method) with a 3.5 cm skin incision along the natural skin crease [1]. From the 37th case, we applied the novel two-step retraction technique (two-step method) to minimize flap invasiveness and to obtain a stable view.
The preoperative evaluation of all the thyroid nodules included fine needle aspiration biopsy (FNAB). When thyroid carcinoma was suspected, high-resolution staging ultrasonography and neck and chest computed tomography (CT) were performed. The ultrasound examinations included both thyroid lobes and all the neck levels (I–VI) [17]. For benign tumours, surgical management was indicated as follows: (1) follicular/Hurthle cell lesions of diameter < 5 cm and (2) palpable benign tumors of diameter ≥ 4 cm.
Cases of thyroid nodules without lateral neck or distant metastasis were enrolled in this study; those involving tumours with posterior capsular invasion or extension to an adjacent structure were excluded due to the possibility of injury to the recurrent laryngeal nerve (RLN), trachea, or oesophagus during the procedure. Cases with goitre or Grave’s disease were also excluded due to the high risk involved.
In thyroid cancer, the extents of thyroidectomy were determined according to the guidelines issued by the 2015 American Thyroid Association [18]. Twenty-three patients with bilateral lesions, adjacent muscle invasion during surgery, or more than five central lymph node metastasis underwent total thyroidectomy. Prophylactic ipsilateral central compartment neck dissection was performed for all the cancer patients.
Details on the clinical and pathologic characteristics, operation type, operative time, postoperative hospital stay, and complications were obtained from our institutional database. This study was approved by Yonsei University’s institutional review board (4–2020-0149), and informed consent from the patients was waived owing to the retrospective nature of this study.
Operative procedure
Skin flap creation with the conventional method
Under general anaesthesia, the patient was placed in a supine position. A backrest was placed underneath the patient to allow neck extension in order to provide a fully exposed surgical space to the surgeon. The arm on the lesion-side was not fixed but draped to allow movement so that it could be raised or stretched laterally during the operation. Generally, the lesion-side arm was raised during flap dissection and regulated as occasion demands during the robotic console time. A 3.5 cm incision was made along the natural skin crease. Flap dissection was performed as in general robotic transaxillary thyroidectomy. The detailed procedure has been described in previous studies [6, 19].
Skin flap creation with the two-step method
The preoperative patient position was the same as that in the conventional method. A 3.5 cm incision was made along the natural skin crease on the lesion-side axilla. With the arm raised, flap dissection was performed over the anterior surface of the pectoralis major muscle, directly toward the sternal notch to find the sternocleidomastoid muscle (SCM). After the SCM was identified below the platysma and its two heads dissected, a narrow (width = 3 cm) version of the Chung’s retractor was inserted, corresponding to the size of the incision. The skin with a small portion of the SCM sternal head was then elevated. The raised arm was stretched laterally to straighten the robotic approach around the posterior neck area. After robotic docking, the subplatysmal layer was further dissected to obtain sufficient space. The two heads of the SCM were then dissected completely to find the strap muscles. The thyroid was found below the strap muscles and after obtaining sufficient space, the surgical assistant inserted the Chung’s retractor below the strap muscles, completing the redocking; this is referred to as “the second step retraction.” The step-by-step robotic procedure after the first docking is shown in Fig. 1 and video.
Robotic thyroidectomy technique
Thyroidectomy was performed as in conventional transaxillary robotic surgery [6]. The robotic camera was employed at the bottom of the SP trocar. The three-arm method was used: Cardiere on the upper site, and two Maryland dissectors on the left and right of the single-port trocar. As the bipolar energy source, Erbe (Erbe USA Inc, Marietta, GA) in the SWIFT COAG mode at a power level of 4–5 was connected to the bilateral Maryland dissectors. Fine upper-pole dissection was performed saving the external branch of RLN and superior parathyroid. Further, the ipsilateral RLN was identified and central compartment dissection was simultaneously performed on the cancer patients. While tracing the nerve, the ipsilateral thyroid was detached from the trachea and a specimen was extracted through an axillary incision. The detailed thyroid lobectomy procedure has been presented in a previous study [20].
For total thyroidectomy, intraoperative nerve monitoring was routinely applied to reduce the risks of RLN injury [21]. Contralateral thyroidectomy was performed after the extraction of the ipsilateral specimen to acquire more working space for the robotic arms. The trachea was pushed down with a suction assistant, the contralateral upper-pole was drawn downward using the robotic grasper, and the superior thyroidal vessel was identified and ligated. After upper-pole dissection, all of the strap muscles around the remnant thyroid were dissected. The contralateral RLN was then identified between the remnant thyroid and the trachea was pushed down by the suction assistant. The RLN was traced above the trachea and detached as a specimen. After the extraction of the contralateral thyroid through an axillary incision, a closed suction drain was inserted for prevention of emergent bleeding or seroma. The wound was closed layer-by-layer.
The role of an assistant
During the whole procedure, one assistant (a field surgeon or a physician assistant(PA)) joined the operation. When creating the robotic flap, the assistant helped retract the skin flap with specially designed fiber optic device. The assistant also supported the installation of Chung’s retractor, robotic docking, and regulation of robotic location after docking. In the case of the two-step method, the assistant helped loosen the Chung’s retractor and indwell the retractor again beneath the strap muscle in the operation field. Also, with a 50 cm curved suction catheter, the assistant aided in counter-traction, smoke emission, and securing the trachea during the whole console time.
Postoperative management
All patients were fitted with a drain to prevent complications from postoperative seroma or hematoma and were discharged on the third or fourth postoperative day(POD) after drain removal. After surgery, all of the patients received levothyroxine to maintain thyroid function or to suppress the TSH level, as required. Hypoparathyroidism, defined as reduction in the serum iPTH level below the normal range regardless of hypercalcaemic symptoms [22], was managed with calcium replacement on occurrence.
Statistical analysis
Details on the clinical characteristics, pathological characteristics, operation data, and complications were obtained from our institutional database. The parameter differences were analysed using student t-tests when appropriate. All statistical analyses were performed using the IBM SPSS Statistics for Windows software (Version 25.0; IBM Corp., Armonk, NY), and the statistically significant difference was defined as p < 0.05.
Result
All operations, including thyroid lobectomy or total thyroidectomy, were performed by a single surgeon (Kee-Hyun Nam). Table 1 lists the clinical characteristics of the 200 patients who underwent START and the pathologic results of 190 patients with thyroid cancer. Among the 200 cases, 198 were female and 2 were male, with a mean age of 34.7 (range: 13–58 years). Thyroid lobectomy was performed for 177patients and total thyroidectomy was performed for 23 patients. Ten patients had benign thyroid nodules, whereas the other 190 had thyroid malignancy. The mean body mass index (BMI) was 22.2 ± 3.7 kg/m2 (range: 15.9–37.0 kg/m2). Except for two patients who wanted to prolong the hospital stay for four days after the operation, patients were discharged on the third POD.
The pathologic characteristics of the 190 patients with thyroid cancer were analysed. The mean tumour size was 0.9 ± 0.8 (range: 0.2–5) cm; 187 patients had papillary thyroid carcinoma (PTC) and 3 had minimally invasive follicular thyroid carcinoma. Thirty-two patients had multifocality (> 1 PTC foci on one side of the thyroidectomy specimen), and twenty had bilaterality. The number of retrieved central lymph nodes (CLNs) was 3.6 ± 3.3 (range: 0–18) and the number of metastatic CLNs was 0.8 ± 1.3 (range: 0–6).
The operative data of thyroid lobectomy cases with START were compared between the conventional method and two-step method (Table 2). Mean total operative time for thyroid lobectomy using conventional method group and two-step method group were 115.3 ± 17.3 and 116.7 ± 23.2 min, respectively (p = 0.700). The working space, docking, and console time were 34.1 ± 7.5 and 28.9 ± 10.9 min (p = 0.007) 5.2 ± 1.7 and 3.8 ± 2.0 min (p = 0.000), and 48.0 ± 14.2 and 60.0 ± 18.5 min (p = 0.000), respectively. Operation time for total thyroidectomy was also calculated. All of the 23 total thyroidectomy cases were performed with two-step method. The total operation time, working space, docking, and console time were 176.6 ± 21.1, 30.3 ± 11.0, 4.9 ± 1.8, and 115.4 ± 19.9 min, respectively.
Two patients had transient hypoparathyroidism that recovered completely after 2 months of calcium replacement. There were no cases of permanent hypoparathyroidism, RLN injury, seroma, or bleeding.
One of the postoperative scars after 6 month from the surgery is provided in Fig. 2. After the complete healing, it became almost indistinguishable from the previous natural skin crease before the operation.
Discussion
The da Vinci SP platform was originally designed for procedures involving deep and narrow working spaces. Since the development of the robot-assisted endoscopic thyroid surgery by Chung et al. [23] in 2007, our institution has actively performed more than 7500 procedures (July 2020) using the da Vinci Si or Xi platforms. With the introduction of the SP system, however, our institution has considered the possibility of reducing invasiveness through this method.
The da Vinci SP system has been used for thyroid surgery at the Yonsei University Severance Hospital, Seoul, Korea since December 2018. For the first four cases in 2018, the gas insufflation method was employed [20]. However, several layers of cervical muscles hindered the approach to the thyroid from the axilla, demanding considerable effort and time with an unstable view. Hence, we reverted to the gasless method and performed additional 200 START. Thus far, to the best of our knowledge, this is the first study to perform as many as 200 thyroidectomy cases using the da Vinci SP platform.
Reduction of the length of the incision was initially attempted using this new apparatus [20]. A narrow version of the Chung’s retractor (Fig. 3) was developed and fibre optics were used during flap dissection. Moreover, the skin flap for robotic thyroidectomy became inevitably narrow due to visual restriction. We realized that upper-pole dissection with a narrow flap was simpler with a laterally extended arm than an upwardly raised one. With the previous Si or Xi platform, we positioned the arm to be upwardly raised in order to ensure least distance from the axilla to thyroid, prohibiting collision between the four robotic arms [1]. Using the SP system, the distance between the axilla and thyroid was no longer a problem.
Nonetheless, longer distance with a small incision was troublesome when creating the working space. The retractor applied during flap dissection could not reach the surface of the thyroid beneath the strap muscles. Hence, we did not fix the lesion-side arm but left it free to allow movement during surgery. We raised the arm during flap dissection and extended it laterally during the console time. When intense concentration was needed on the central compartment, we again raised the arm to facilitate the direct linear approach.
The other problem was that dissection of the skin flap for robotic thyroidectomy around the strap muscles was not visually safe due to the minimization of the incision. We could not easily secure a clear view around the strap muscle with a 3.5 cm incision. Although there were no specific complications, we recognized the necessity for improving the flap dissection. Hence, we employed the two-step method, where we dissected only half the flap, applied docking, completed flap dissection with the robotic console, and redocked the SP robot.
In addition to facilitating a deep and narrow approach, the other advantage of the SP is the ease of docking, de-docking, and redocking. In the Xi or Si systems, four robotic instruments and four robotic trocars had to be moved by adjusting the joints of the four robotic arms, while in the SP, with all the instruments within the trocar, only the single-port trocar needed to be moved. This made the two-step procedure possible without any delay in the operative time.
For the surgeon, the effect of two-step method was apparent; the fatigue of the surgeon and the assistant during flap dissection was reduced. Instead of focusing on retracting all the strap muscles upward, we were able to work between the muscles by spreading the strap muscles with the robotic console, which allowed sufficient working space for the operation. This is also significant since robotic dependency has increased during robotic thyroidectomy.
Moreover, not only the incision length but also the extent of flap dissection for thyroidectomy was decreased using the SP system (Fig. 4A, B). With considerable time and effort, we realized that an entire conventional skin flap for robotic thyroidectomy was not necessary for thyroidectomy with the SP system.
Although we were comfortable using four linear robotic instruments initially, with increasing experience over time, we became accustomed to the haptic, flexible SP instruments and could freely manipulate the SP system and continuously attempt to render a narrower flap. With the current extent of the robotic transaxillary flap using the SP system, we are uncertain about the benefits of other robotic approaches such as BABA approach, which requires four incisions including two axillary incisions,(2) or transoral thyroidectomy,(4) which occasionally needs an axillary incision for thyroid removal and drain insertion. Furthermore, for the SP system, a spherical space needs to be controlled without restriction (Fig. 5). Beneath the skin, we believe that the transaxillary flap is advantageous for creating sufficient working space for the SP system, without encountering the bone structure.
By applying changes in the patient position during the operation, injury to the brachial plexus or radial, ulnar, and median nerve injuries was avoided in western patient populations [24,25,26,27,28,29]. If raising the lesion-side arm is not possible, we recommend a laterally stretched arm with the use of longer fibre optics during flap dissection to reach the SCM from the axillary incision.
Currently, a flexible ultrasonic vibration energy device such as the harmonic scalpel is not available due to technical difficulties, which ensued the da Vinci SP system to be equipped with the Erbe. Despite the unfamiliarity with the new energy source, no specific complication occurred in our 200-case experience, and it is noteworthy that there are benefits from the usage of the Erbe compared to the harmonic scalpel. In the SP system, both sides of the flexible Maryland dissectors can be connected to the Erbe and every space of the surgical field can be easily accessed without considerable effort. Moreover, the sharp Maryland forceps facilitate sophisticated dissection, while tracing the nerve and detaching the berry ligament from the nerve without significant thermal injury. Although we could not provide the statistical data due to the retrospective nature of this study, the quality of the patient’s voice after the START is significantly outstanding compared with that treated with any other energy device. The comparison of thermal damage between bipolar energy and ultrasonic energy devices are controversial.[30,31,32,33,34,35,36,37,38,39,40,41]. Among them, Sutton et al.[42] reported that bipolar energy produce smaller increase in the temperature than harmonic scalpel. Due to the sharp applicators (Maryland) and multiple, short firing of the bipolar energy, we believe we could minimize the thermal damage. This particular subject will be further investigated hereafter.
Our study has revealed satisfactory results with a large sample of 200 patients who underwent START using the da Vinci SP system. As expected, the axillary scar became almost indistinguishable over time (Fig. 2). We assume that this is due to the fact that we used the natural skin crease [43,44,45,46]. However, the retrospective nature of the analysis, single surgeon experience, and lack of comparative data for open or other surgical platforms are the limitations of the study. Furthermore, long-term oncological outcomes such as the survival, recurrence, and quality of life need to be evaluated. Therefore, multi-centre prospective studies are required to further evaluate the role of the da Vinci SP platform in thyroid surgeries.
We can conclude that START with the da Vinci SP system is a practical surgical method with minimal invasiveness, particularly when the two-step method is applied. This method offers cosmetic and functional benefits to the patients and reduces the workload fatigue of surgeons.
References
Kang S-W, Jeong JJ, Yun J-S, Sung TY, Lee SC, Lee YS et al (2009) Robot-assisted endoscopic surgery for thyroid cancer: experience with the first 100 patients. Surg Endosc 23(11):2399–2406
Lee KE, Rao J, Youn Y-K (2009) Endoscopic thyroidectomy with the da Vinci robot system using the bilateral axillary breast approach (BABA) technique: our initial experience. Surg Laparoscopy Endoscopy Percutaneous Tech 19(3):e71–e75
Singer MC, Seybt MW, Terris DJ (2011) Robotic facelift thyroidectomy: I. Preclinical simulation and morphometric assessment. Laryngoscope 121(8):1631–1635
Richmon JD, Kim HY (2017) Transoral robotic thyroidectomy (TORT): procedures and outcomes. Gland Surg 6(3):285
Kandil E, Saeed A, Mohamed SE, Alsaleh N, Aslam R, Moulthrop T (2015) Modified robotic-assisted thyroidectomy: an initial experience with the retroauricular approach. Laryngoscope 125(3):767–771
Ryu HR, Kang S-W, Lee SH, Rhee KY, Jeong JJ, Nam K-H et al (2010) Feasibility and safety of a new robotic thyroidectomy through a gasless, transaxillary single-incision approach. J Am Coll Surg 211(3):e13–e19
Kang S-W, Lee SC, Lee SH, Lee KY, Jeong JJ, Lee YS et al (2009) Robotic thyroid surgery using a gasless, transaxillary approach and the da Vinci S system: the operative outcomes of 338 consecutive patients. Surgery 146(6):1048–1055
Kang S-W, Jeong JJ, Nam K-H, Chang HS, Chung WY, Park CS (2009) Robot-assisted endoscopic thyroidectomy for thyroid malignancies using a gasless transaxillary approach. J Am Coll Surg 209(2):e1–e7
Kang S-W, Park JH, Jeong JS, Lee CR, Park S, Lee SH et al (2011) Prospects of robotic thyroidectomy using a gasless, transaxillary approach for the management of thyroid carcinoma. Surgical Laparoscopy Endoscopy & Percutaneous Techniques 21(4):223–229
Lee J, Chung WY (2012) Current status of robotic thyroidectomy and neck dissection using a gasless transaxillary approach. Curr Opin Oncol 24(1):7–15
Chung WY (2012) Pros of robotic transaxillary thyroid surgery: its impact on cancer control and surgical quality. Thyroid 22(10):986–987
Ryu HR, Lee J, Park J-H, Kang S-W, Jeong JJ, Hong J-Y et al (2013) A comparison of postoperative pain after conventional open thyroidectomy and transaxillary single-incision robotic thyroidectomy: a prospective study. Ann Surg Oncol 20(7):2279–2284
Hundahl SA, Cady B, Cunningham MP, Mazzaferri E, McKee RF, Rosai J et al (2000) Initial results from a prospective cohort study of 5583 cases of thyroid carcinoma treated in the United States during 1996: an American college of surgeons commission on cancer patient care evaluation study. Cancer 89(1):202–217
Gosnell JE, Clark OH (2008) Surgical approaches to thyroid tumors. Endocrinol Metab Clin North Am 37(2):437–455
La Vecchia C, Malvezzi M, Bosetti C, Garavello W, Bertuccio P, Levi F et al (2015) Thyroid cancer mortality and incidence: a global overview. Int J Cancer 136(9):2187–2195
Lim H, Devesa SS, Sosa JA, Check D, Kitahara CM (2017) Trends in thyroid cancer incidence and mortality in the United States, 1974–2013. JAMA 317(13):1338–1348
Choi JS, Kim J, Kwak JY, Kim MJ, Chang HS, Kim E-K (2009) Preoperative staging of papillary thyroid carcinoma: comparison of ultrasound imaging and CT. Am J Roentgenol 193(3):871–878
Haugen BR, Alexander EK, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE et al (2016) 2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid 26(1):1–133
Lee YK, Kim D, Shin DY, Lee CR, Lee EJ, Kang S-W et al (2019) The prognosis of papillary thyroid cancer with initial distant metastasis is strongly associated with extensive extrathyroidal extension: a retrospective cohort study. Ann Surg Oncol 26(7):2200–2209
Kim K, Kang S-W, Kim JK, Lee CR, Lee J, Jeong JJ et al (2020) Robotic transaxillary hemithyroidectomy using the da Vinci SP robotic system: initial experience with 10 consecutive cases. Surg Innov 27(3):256–264
Horne SK, Gal TJ, Brennan JA (2007) Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy. Otolaryngol Head Neck Surg 136(6):952–956
Rivere AE, Brooks AJ, Hayek GA, Wang H, Corsetti RL, Fuhrman GM (2014) Parathyroid hormone levels predict posttotal thyroidectomy hypoparathyroidism. Am Surg 80(8):817–820
Kang S-W, Jeong JJ, Yun J-S, Sung TY, Lee SC, Lee YS et al (2008) Robot-assisted endoscopic thyroid surgery for thyroid cancer; initial experience of consecutive 100 patients. Korean Thyroid Association 1(2):129–135
Perrier ND, Randolph GW, Inabnet WB, Marple BF, Vanheerden J, Kuppersmith RB (2010) Robotic thyroidectomy: a framework for new technology assessment and safe implementation. Thyroid 20(12):1327–1332
Kandil E, Abdelghani S, Noureldine SI, Friedlander P, Khalek MA, Bellows CF et al (2012) Transaxillary gasless robotic thyroidectomy: a single surgeon’s experience in North America. Arch Otolaryngol Head Neck Surg 138(2):113–117
Kandil EH, Noureldine SI, Yao L, Slakey DP (2012) Robotic transaxillary thyroidectomy: an examination of the first one hundred cases. J Am Coll Surg 214(4):558–564
Davis SF, Khalek MA, Giles J, Fox C, Lirette L, Kandil E (2011) Detection and prevention of impending brachial plexus injury secondary to arm positioning using ulnar nerve somatosensory evoked potentials during transaxillary approach for thyroid lobectomy. Am J Electroneurodiagnostic Technol 51(4):274–279
Schwartz DM, Sestokas AK, Hilibrand AS, Vaccaro AR, Bose B, Li M et al (2006) Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery. J Clin Monit Comput 20(6):437–444
Kamel IR, Drum ET, Koch SA, Whitten JA, Gaughan JP, Barnette RE et al (2006) The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: a retrospective analysis. Anesth Analg 102(5):1538–1542
Družijanić N, Pogorelić Z, Perko Z, Mrklić I, Tomić S (2012) Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure. Can J Surg 55(5):317
Diamantis T, Gialikaris S, Kontos M, Gakiopoulou C, Felekouras E, Papalois A et al (2008) Comparison of safety and efficacy of ultrasonic and bipolar thermal energy: an experimental study. Surg Laparoscop Endoscopy Percutaneous Tech 18(4):384–390
Diamantis T, Kontos M, Arvelakis A, Syroukis S, Koronarchis D, Papalois A et al (2006) Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure. Surg Today 36(10):908–913
Sartori PV, De Fina S, Colombo G, Pugliese F, Romano F, Cesana G et al (2008) Ligasure versus Ultracision® in thyroid surgery: a prospective randomized study. Langenbecks Arch Surg 393(5):655–658
Manouras A, Lagoudianakis EE, Antonakis PT, Filippakis GM, Markogiannakis H, Kekis PB (2005) Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy. Head Neck 27(11):959–962
Cordón C, Fajardo R, Ramírez J, Herrera MF (2005) A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Surgery 137(3):337–341
Dror A, Salim M, Yoseph R (2003) How I do it: Sutureless thyroidectomy using electrothermal system: a new technique. J Laryngol Otol 117(3):198
Lachanas VA, Prokopakis EP, Mpenakis AA, Karatzanis AD, Velegrakis GA (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngol Head Neck Surg 132(3):487–489
Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231(3):322
Shemen L (2002) Thyroidectomy using the harmonic scalpel: analysis of 105 consecutive cases. Otolaryngol Head Neck Surg 127(4):284–288
Siperstein AE, Berber E, Morkoyun E (2002) The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 137(2):137–142
Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the UltraCision® harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech 14(1):9–12
Sutton P, Awad S, Perkins A, Lobo D (2010) Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic ScalpelTM and the LigasureTM. Br J Surg 97(3):428–433
Slemp AE, Kirschner RE (2006) Keloids and scars: a review of keloids and scars, their pathogenesis, risk factors, and management. Curr Opin Pediatr 18(4):396–402
Rudolph R (1987) Wide spread scars, hypertrophic scars, and keloids. Clin Plast Surg 14(2):253–260
Lanza J, Lucente F, Har-El G. Keloid. Otolaryngology--head and neck surgery: official journal of American Academy of Otolaryngology-Head and Neck Surgery. 1992;106(6):741–2.
Wolfram D, Tzankov A, Pülzl P, Piza-Katzer H (2009) Hypertrophic scars and keloids—a review of their pathophysiology, risk factors, and therapeutic management. Dermatologic Surg 35(2):171–181
Acknowledgements
The authors thank the Severance Robot team, especially Ho Young Kim and Hee Chang Yu, for their technical support.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Disclosures
Drs. Jin Kyong Kim MD, Sun Hyung Choi MD, Soon Min Choi MD, Hye Ryeon Choi MD, Cho Rok Lee MD, Sang-Wook Kang MD, PhD, Jong Ju Jeong MD, Kee-Hyun Nam MD, PhD, and Woong Youn Chung MD, PhD have no conflicts of interest or financial ties to disclose.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Supplementary file1 (MP4 492743 KB)
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kim, J.K., Choi, S.H., Choi, S.M. et al. Single-port transaxillary robotic thyroidectomy (START): 200-cases with two-step retraction method. Surg Endosc 36, 2688–2696 (2022). https://doi.org/10.1007/s00464-021-08837-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00464-021-08837-9