Abstract
Purpose
Different non-invasive and invasive imaging modalities are used to determine carotid artery stenosis severity that remains a principal parameter in clinical decision-making. We compared stenosis degree obtained with different modalities against vascular imaging gold standard, intravascular ultrasound, IVUS.
Methods
300 consecutive patients (age 47–83 years, 192 men, 64% asymptomatic) with carotid artery stenosis of “ ≥ 50%” referred for potential revascularization received as per study protocol (i) duplex ultrasound (DUS), (ii) computed tomography angiography (CTA), (iii) intraarterial quantitative angiography (iQA) and (iv) and (iv) IVUS. Correlation of measurements with IVUS (r), proportion of those concordant (within 10%) and proportion of under/overestimated were calculated along with recipient-operating-characteristics (ROC).
Results
For IVUS area stenosis (AS) and IVUS minimal lumen area (MLA), there was only a moderate correlation with DUS velocities (peak-systolic, PSV; end-diastolic, EDV; r values of 0.42–0.51, p < 0.001 for all). CTA systematically underestimated both reference area and MLA (80.4% and 92.3% cases) but CTA error was lesser for AS (proportion concordant-57.4%; CTA under/overestimation-12.5%/30.1%). iQA diameter stenosis (DS) was found concordant with IVUS in 41.1% measurements (iQA under/overestimation 7.9%/51.0%). By univariate model, PSV (ROC area-under-the-curve, AUC, 0.77, cutoff 2.6 m/s), EDV (AUC 0.72, cutoff 0.71 m/s) and CTA-DS (AUC 0.83, cutoff 59.6%) were predictors of ≥ 50% DS by IVUS (p < 0.001 for all). Best predictor, however, of ≥ 50% DS by IVUS was stenosis severity evaluation by automated contrast column density measurement on iQA (AUC 0.87, cutoff 68%, p < 0.001). Regarding non-invasive techniques, CTA was the only independent diagnostic modality against IVUS on multivariate model (p = 0.008).
Conclusion
IVUS validation shows significant imaging modality-dependent variations in carotid stenosis severity determination.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Despite growing understanding of the role of plaque morphology [1,2,3,4,5,6,7,8,9,10], stenosis severity remains the fundamental factor in clinical decision-making with regard to recommending medical or interventional therapy to symptomatic and asymptomatic patients with internal carotid artery (CA) atherosclerosis [2, 3, 11,12,13].
In the past, major trials used mostly intraarterial quantitative angiography (iQA) for grading ICA stenosis [14, 15]. However, iQA poses a non-negligible risk of cerebral ischemic complications (typically ≈0.3%) [16,17,18,19]. In addition, iQA needs to be obtained in multiple projections to determine the maximal diameter stenosis [20, 21]. Considering safety and economic reasons, iQA has been largely replaced by non-invasive methods including Doppler ultrasound (DUS), computed tomography angiography (CTA) and magnetic resonance angiography (MRA) [22]. These modalities have been employed in more recent trials; often different ones in different clinical trials [14, 15, 23,24,25,26]. Even more importantly, the non-invasive modalities are routinely used these days for clinical decision-making including decisions on carotid revascularization in primary and secondary stroke prevention [2, 3, 11,12,13].
It has been clear for some time now that discrepancies may exist between the different techniques of carotid stenosis severity determination [22, 27,28,29]; this issue, however, has not been systematically investigated.
Materials and methods
Design
This was a monocentric prospective study enrolling consecutive neurologically asymptomatic or symptomatic patients with CA referral stenosis of at least “50%” in the context of potential revascularization. A systematic evaluation was performed of the differences in stenosis severity determination (clinically-relevant example in Fig. 1) using routine imaging modalities—duplex ultrasound (DUS), computed tomography angiography (CTA), and intra-arterial quantitative angiography (iQA)—against the vascular imaging gold standard, intravascular ultrasound (IVUS) [28,29,30]. Target population of 300 participants was recruited over the period of 19 months.
Patients with highly calcified lesions [40] that precluded reliable assessment of velocities as per agreement of 2 experienced ultrasonographers, and those with chronic kidney disease with glomerular filtration rate < 30 ml/minute, were excluded.
309 consecutive patients meeting clinical and non-invasive imaging inclusion/exclusion criteria were enrolled to obtain 300 data-sets suitable for analysis. DUS, CTA, and subsequently iQA and IVUS were performed (all examinations within 1 month). In 8 subjects, iQA revealed an ‘artery near-occlusion’ precluding IVUS visualization of the native carotid lesion. In those cases, IVUS visualization would have required, by agreement of 2 experienced operators, lesion predilatation with a small-diameter balloon (thus losing any relationship between the basal non-invasive measurements). In 1 other patient, there was a failure to save IVUS data. Thus 9 initially considered patients (2.9%) were screening failures in the context of obtaining required data-sets. In the case of bilateral disease, the more severe lesion was evaluated unless this was considered too tight for a safe passage with the IVUS transducer. Medical treatment prior to iQA and IVUS involved aspirin and a statin. The majority of patients (262/300, 87.3%) were also on an angiotensin-converting enzyme inhibitor or angiotensin receptor blocker.
The study was accepted by the institutional Ethics Committee and all participants provided written informed consent to participate. This work was supported by the National Committee for Scientific Research (PL-N402-184234), the Polish Cardiac Society/Servier Clinical Research in Atherosclerosis grant (to PM), the National Science Centre (2022/06/X/NZ5/00583) and Jagiellonian University Medical College (K/ZDS/007819). The authors have no relevant financial or non-financial interests to disclose.
DUS examination
DUS scanning was performed with a Toshiba Aplio PowerVision ultrasound machine (Toshiba Medical Systems Co., Ltd., Tokyo, Japan) equipped with a 4–11 MHz linear-array transducer in a certified vascular ultrasound imaging lab by one of two experienced operators working together on a daily basis. In case of doubt, the other DUS operator was consulted and an agreement was reached. The Doppler waveform was obtained with an angle of insonation equal to 60°, angles between 45° and 60° were considered acceptable in case of anatomic constraints [32, 37]. The CA was sampled through the region of stenosis completely until the distal end of the plaque is visualized, to ensure that the site of highest velocity has been located. The highest flow velocities – end diastolic velocity (EDV) and peak systolic velocity (PSV) were recorded. In the first 100 study arteries considered by agreement of the 2 DUS operators appropriate for optimal measurement of diameter stenosis according to the NASCET method, DUS minimal lumen diameter (MLD) and DUS distal reference diameter (RD) were determined by agreement of the ultrasonographers.
CTA
Image acquisition of the supra-aortic vessels was obtained with a 64-multi-detector-row CT system (Somatom 64, Siemens, Erlangen, Germany) using a routine imaging protocol. CTA measurements (including reference area, RA; minimal lumen area, MLA and area stenosis AS) were performed by agreement of 2 senior radiologists with > 20 years and > 15 years of experience in reporting carotid CTA.
iQA
After obtaining transfemoral or transradial access, unfractionated heparin (UFH) was routinely administered at the dose of 5000 IU. In case of cerebral protection device use or post-imaging proceeding to intervention, UFH dose was further titrated to achieve an activated clotting time of at least 250 s. Selective digital angiography of the index carotid artery was performed using Coroscop or Axiom Artis Zee angiograph (Siemens) in multiple (median 4) angulated projections to define the narrowest lumen diameter while minimizing foreshortening and avoiding an overlap of side branches. The view where the stenosis was tightest [18, 19] was used for quantitative measurements (Quantcor QA v5.0, Siemens). Measurements (including RD, MLD, DS, RA, MLA, AS) were performed offline by agreement of two Angiographic Core Lab analysts and were then verified by an angiographic corelab supervisor.
IVUS
Details regarding IVUS images acquisition and analysis are provided in Ref. [39]. Consistent with our prior experience [41], the decision to use a neuroprotection device for IVUS imaging was based on the lesion morphology, severity and the presence/absence of a history of ipsilateral clinical symptoms or asymptomatic cerebral infarct, and it was left to the operator performing the case.
In brief, a commercially-available rapid-exchange IVUS catheter (3.5F, scanner diameter 1.15 mm Eagle Eye Gold or Platinium, Volcano-Philips Corp.) was introduced to the index ICA over a 0.014-inch coronary guidewire (in case of unprotected imaging or imaging under proximal cerebral protection) or, in case of distal embolic protection device use, over the wire of the protective filter. At least two IVUS runs with automatic motorized pullback were performed with the speed of 0.5 mm/sec. ChromaFlo application (Volcano-Philips) was routinely used in one IVUS run to improve the determination of the interface between the lumen and the vessel wall or atherosclerotic plaque [39, 42, 43]. In addition, in short, or ambiguous lesions, a very slow manual pullback was additionally performed in order not to miss the minimal lumen site [40]. IVUS measurements of the minimal lumen area (MLA) and distal reference area (RA) were performed at maximal vessel diastole using QIvus software (v.2.0, Medis Medical Imaging Systems). IVUS measurements were performed by agreement of two IVUS corelab analysts with > 10 years of experience in carotid IVUS analysis and were further approved by the IVUS corelab supervisor. The analysts performing DUS, CTA, iQA and IVUS measurements were blinded against one another.
The % diameter stenosis (DS) was computed as [(RD-MLD)/RD]*100% according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method [14]. The % area stenosis (AS) was computed as [1 − (MLA/RA)]*100%.
Data display and statistical analysis
Categorical variables were presented as numbers and percentages. Continuous variables were expressed, unless specified otherwise, as median and quartiles (Q1–Q3). Receiver operating characteristic (ROC) curves were constructed to assess the accuracy of DUS, CTA and iQA measurements in comparison to IVUS. The overall accuracy was expressed by the area under the ROC curve (AUC; ranging from 0.5 [no relationship] to 1.0 [perfect relationship]). The correlation between DUS/CTA and IVUS was presented as a correlation coefficient (‘r’; ranging from 0 [no correlation] to 1.0 [perfect correlation]). Furthermore, the agreement between quantitative measurements was displayed using histograms and Bland–Altman plots [44]. In addition, the proportion of measurements concordant with IVUS along with those under/overestimated was calculated and displayed in a bar graph format. Concordance with IVUS measurement was defined as a value within ± 10% of the IVUS measurement; values falling below were considered underestimated whereas those falling above were considered overestimated against IVUS as a reference. Mann–Whitney U test was used to assess differences in the distributions between the two groups. A univariate and multivariable model was used to evaluate the predictive value of DUS and CTA for ≥ 50% and ≥ 75% AS by IVUS. The thresholds of 75% AS and 50% DS were used because (with area calculated as π (D/2)) 75% area stenosis corresponds to 50% diameter stenosis [35, 36].
Results
A complete imaging package, including DUS PSV and EDV, CTA, iQA and IVUS was obtained in 300 patients; whose clinical characteristics are given in Table 1.
Table 2 shows baseline characteristics of the study lesions. iQA imaging (that routinely involved anticoagulation with ≥ 5000 IU UFH) and IVUS imaging (with elective use of a proximal or distal cerebral protection device) were uncomplicated. 112 (37.3%) study lesions were evaluated with IVUS in absence of a cerebral protection device use. IVUS imaging was filter-protected in 142 (47.3%) cases, whereas proximal protection was used in 46 (15.3%) cases.
Figures 2–4 and Suppl Fig. 2 to Suppl Fig. 4 demonstrate the relationship between the routine imaging modalities and IVUS measurements.
There was a curvilinear relationship between DUS velocities and IVUS-AS (correlation coefficient of 0.51 and 0.45, respectively, p < 0.001 for both, Fig. 2) and, similarly, between DUS velocities (PSV, EDV) and IVUS-MLA (correlation coefficient of 0.49 and 0.42, respectively, p < 0.001 for both; Suppl Fig. 2-I).
Study data-derived mathematical formulas relating PSV and EDV with AS and MLA by IVUS according to the best-fit curves are provided in Fig. 2 and Suppl Fig. 2-I.
DUS MLD and RD measurements were performed in the first 100 (out of 126; 79.4%) study arteries with visualization considered sufficient to appropriately determine stenosis severity according to NASCET. There was only a moderate (though statistically significant) correlation between DUS-MLD and IVUS-MLD (r = 0.35, p < 0.001), DUS-RD and IVUS-RD (r = 0.33, p < 0.001), and DUS-DS and IVUS-DS (r = 0.41, p < 0.001). DUS systematically underestimated MLD and overestimated DS (Suppl Fig. 2-II, Suppl Fig. 2-III, and Suppl Fig. 2-IV, Suppl Table 1).
There was a good correlation between AS by CTA and IVUS (r = 0.69, p < 0.001, Fig. 3 and Suppl Fig. 3-I).
CTA measurements of AS were concordant with IVUS in 57.4% (CTA underestimation in 12.5% cases, overestimation in 30.1%; Fig. 3B1, Suppl Table 1). This occurred despite the CTA systematic underestimation of MLA (92.3% cases) and RA (80.4%) in relation to IVUS (Suppl Fig. 3-II D1 and Suppl Fig. 3-III D1, Suppl Table 1).
The largest proportion of measurements concordant with IVUS (65.3%, Fig. 3B2) occurred for densitometric evaluation of AS by iQA. With this technique, comparing automatically the density of the contrast column in the reference segment and at the point, it reaches a minimum, there was a similar proportion of under- and overestimated measurements (14.8% and 19.9% respectively, Fig. 3B2). The relationship between densitometric iQA and IVUS for MLA and RA measurements is presented in Suppl Fig. 3-II and Suppl Fig. 3-III. The densitometric iQA measurements highly correlated with IVUS (r = 0.75 for AS, r = 0.82 for MLA, r = 0.60 for RA, p < 0.001 for all). iQA measurements of DS showed concordance with IVUS-DS only in 41.1%. iQA underestimated the IVUS measurement in 7.9%, whereas overestimation in relation to IVUS occurred in 51.0% of cases (Suppl Fig. 3-IV D).
Overall, the correlation between DS by iQA and IVUS was good and statistically significant (r = 0.63, p < 0.001). Data for MLD and RD by iQA vs IVUS are given in Suppl Fig. 3-V and Suppl Fig. 3-VI respectively.
ROC analysis identified iQA densitometric measurement of the stenosis severity as the best predictor of IVUS-determined AS ≥ 75% (AUC 0.88, cutoff 74%, Fig. 4). Individual ROC analyses of the predictive values of DUS flow velocities and CTA for IVUS-DS ≥ 50% and IVUS-AS ≥ 75% are provided in Suppl Fig. 4-I and Suppl Fig. 4-II.
On univariate model, PSV (ROC area under the curve, AUC 0.77, cutoff 2.6 m/s), EDV (AUC 0.72, cutoff 0.71 m/s) and CTA DS (AUC 0.83, cutoff 59.6%) were predictors of ≥ 50% DS by IVUS (p < 0.001 for all). Detailed data including sensitivity, specificity and the positive and negative predictive value of PSV, EDV and CTA in determining AS ≥ 75% and DS ≥ 50% by IVUS are given in Tables 3 and 4.
The multivariable model eliminated PSV and EDV, leaving CTA as a sole (amongst those evaluated in the study) independent non-invasive diagnostic modality to determine carotid stenosis severity (p = 0.008).
Discussion
Despite accumulating evidence for the role of carotid plaque morphology in relation to the risk of carotid-related cerebral injury and stroke [1,2,3,4,5,6,7,8,9,10], current guidelines continue to recommend using stenosis severity thresholds (usually 50% and 70% in symptomatic patients and 60% and 80% in asymptomatic subjects) as the principal parameter in clinical decision-making that includes revascularization by surgical or endovascular route [2, 3, 11,12,13].
This is the first prospective study comparing typically used non-invasive modalities (DUS and CTA) against the vascular imaging “gold standard” tool, IVUS, in evaluating the degree of carotid artery stenosis. DUS velocities (PSV, EDV) showed a highly significant though only moderate correlation (coefficient value of ≈0.4–0.5) with IVUS measurements of minimal lumen diameter and area stenosis. The relationship was yet weaker between the DUS NASCET and IVUS measurement of MLD and DS, confirming that DUS should not be used as a sole imaging modality to determine management in individuals with carotid stenosis [45,46,47]. Even with accurate lumen-artery border detection, the one-dimensional ultrasound imaging may lead to underestimation of MLD in case of irregular (eg., elliptic on cross-section) lesion. In our examination, only RD measurement reached better (moderate) accuracy – most likely due to regular, circular shape and better distance/spatial resolution ratio that are naturally more problematic for the minimal lumen.
Reduction of diameter stenosis (DS) on intra-arterial (catheter) quantitative angiography (iQA) has been the reference standard in reporting carotid artery stenosis severity as “% stenosis” [14, 26]. The iQA-DS measurement has been applied in pivotal revascularization trials as a sole [14, 26] or prevailing [48, 49] technique. We found that iQA evaluation of diameter stenosis is broadly consistent with IVUS; however, iQA tends to systematically overestimate DS against IVUS (Suppl Fig. 3-IV).
Our work shows that the sensitivity and specificity of PSV appear acceptable to detect IVUS-confirmed area stenosis of ≥ 75% with the PSV cutoff value of ≈2.6 m/s (Suppl Fig. 4-II), and similar findings were obtained for ≥ 50% DS (Suppl Fig. 4-I). However, for several reasons, DUS may fail in any precise determination of AS (and DS), particularly in less severe lesions [22, 48, 49]. First, for anatomic reasons DUS may not show the site of MLD in non-concentric lesions in particular. Another important factor that may reduce the overall accuracy of DUS with respect to the flow velocities may be the presence of contralateral carotid occlusion, leading to the unilateral DUS velocities rise associated with compensatory blood flow increase [52, 53]. It has been suggested that the accuracy of non-invasive imaging for the evaluation of cervical carotid artery stenosis may be generally overestimated in the literature [54,55,56]. This is relevant to clinical practice as—following the methodology of some large trials [23, 25]—up to 40% CEAs may still be performed today based on isolated DUS measurements [57]. Series comparing non-invasive methods with iQA indicate that the grading of carotid stenosis as medical or potentially surgical remains uncertain in a relatively high proportion of patients, suggesting the use of two imaging modalities for decision-making on revascularization [2]. With DUS use for stenosis degree evaluation, 1 out of 6 arteries would be reclassified by CTA [58]. It should be emphasized that DUS alone is not sufficient to distinguish a non-significant vs borderline (such as 50–60%) carotid stenosis with adequate accuracy [59, 60]. This observation is of crucial importance as border-line stenosis (50% for symptomatic and 60% for asymptomatic patients) is a threshold for intervention according to current guidelines [2, 3, 11,12,13]. Recent meta-analysis including 809 carotids confirmed a very poor sensitivity (31%) while it indicated a sufficient specificity (84%) for grading 50–69% stenosis with DUS as compared to iQA. DUS accuracy for grading 70–99% carotid stenosis seems to have a higher sensitivity (83%) but much lower specificity (54%) [54]. However, higher rates of DUS-related misclassifications have been reported, particularly in large-diameter arteries [61]. A recent study showed that the qualification to surgical treatment of carotid artery stenosis suffers from a wide variability in carotid velocity thresholds in different DUS laboratories [62]. This directly influences the treatment decision-making [60].
Even though PSV and EDV were univariate predictors of ≥ 75% IVUS-AS (and ≥ 50% IVUS-DS) in the present study (Suppl Fig. 4-II, Suppl Fig. 4-I), they were both eliminated by CTA in multivariate analysis (Tables 3, 4). Although this might suggest using CTA as a single diagnostic tool, DUS remains the primary screening modality due to a non-negligible risk of CTA contrast-related complications and cost [2, 3, 11,12,13]. We found that although CTA systematically underestimates both MLA and RA, it is highly accurate in AS evaluation (Fig. 3 A1 and B1, Suppl Fig. 3-II A1-D1, Suppl Fig. 3-III A1-D1). CTA does not differentiate between the systolic and diastolic flow whereas IVUS takes (in particular—reference) measurements when the vessel reaches its greatest diameter that may be particularly relevant for the reference segment measurements [63]. Moreover, CT diagnostic accuracy is markedly reduced with lesion calcification [64, 65]. Despite these limitations, not only CTA accuracy in detecting ≥ 50% DS and ≥ 75% AS is greater than that of DUS, but also—according to the present analysis – the overall diagnostic accuracy is not increased significantly by adding DUS in the ROC analysis (Tables 3, 4).
An optimal carotid stenosis screening tool should be both highly sensitive and highly specific (Fig. 4, Suppl Fig. 4-I, Suppl Fig. 4-II). When considering DUS as a screening tool, the velocity threshold should optimally be decreased to the value joining high sensitivity with reasonable loss in specificity to reduce the proportion volume of false-negative results and reduce, at the same time, the number of other examinations (such as CTA) needed for a cross-verification. With the use of only one diagnostic non-invasive method (DUS in particular), a significant proportion of patients may be misclassified into a discordant category (surgical vs. medical), providing an argument for performing both types of non-invasive imaging [58]. In case of discordance between the non-invasive methods, intra-arterial angiography may be needed to determine lesion severity [20, 21, 42, 43]. Once iQA is performed, IVUS may accurately visualize the MLA and RA, assess plaque morphology [39], and provide procedural quality control [66,67,68].
Important novel information from this study is the high diagnostic accuracy of iQA densitometric measurement (density of a contrast column in MLD in a relation to a RD) that was found to be greater than that of the conventionally-used iQA diameter stenosis.
The magnitude of imaging modality-dependent variations in the numeric “value” of stenosis severity identified in the present study suggests that evidence-based decision-making should consult individual clinical trials and studies with respect to the specific modality used to determine stenosis severity. In case of discrepancies, at least CTA should be employed.
Carotid stenosis severity remains important clinically, as totality of current evidence suggests that patients with increased-stroke-risk asymptomatic carotid stenosis of “60–99%” should be considered for low-risk carotid revascularization on top of maximized medical therapy that is now known to be unable to sufficiently control stroke risk in relation to carotid stenosis [69].
Limitations
Our work has evaluated two non-invasive methods, DUS and CTA, in relation to IVUS. We have not been able to include MRA in our analysis because this technique is rarely used in our institution and in referring hospitals. This is consistent with overall rather limited use of MRA in diagnosing carotid stenosis and determining its severity in clinical practice of carotid revascularization [70]. In a recent analysis of imaging prior to CEA in nearly 20,000 procedures in the Vascular Quality Initiative database, MRA was the sole imaging modality in only 2.0% patients whereas DUS and MRA were performed in 9.4% [70].
Other potentially significant shortcomings of our work, in the context of DUS validation with IVUS, may arise from our analysis limited to the cross-sectional stenosis severity. Other factors, such as cardiac output and arterial blood pressure/peripheral vascular resistance [53], contralateral carotid artery occlusion (or severe stenosis) and lesion length may affect DUS velocities. Our pilot analysis indicated that automated pullback of the IVUS catheter tends to be uneven at carotid bifurcations, precluding measurements of the lesion length [71]; a problem similar to the effect of movement artifacts raised previously by other investigators in coronary bifurcations [72]. In addition, in the carotids, there is also an additional, prominent, “jumping” of the IVUS probe, back-and-forth, with the heartbeat [71]. The role of contralateral carotid occlusion (if present) and the potential role of the lesion length on DUS flow velocities require further evaluation. Furthermore, the CCA/ICA PSV ratio was not included into analysis as a result of lack of routine recordings of the CCA velocities. Finally, our analysis intentionally excluded patients with highly calcified lesions as for those patients it is not possible to determine precisely stenosis severity using DUS and CTA [73, 74].
Clinical implications
Stenosis severity directly affects treatment decisions in patients with both symptomatic or asymptomatic carotid stenosis. Our work identified significant imaging modality-dependent variations in carotid stenosis severity determination using IVUS validation. Analysis of the value of routine imaging modalities such as DUS and CTA against imaging gold standard, IVUS, confirmed that Doppler ultrasound flow velocities are not a reliable predictor of stenosis severity especially in ‘borderline’ stenosis. Furthermore, we found that CTA overestimated stenosis severity in more than 30% of patients. This means that some patients operated solely on CTA imaging might not benefit from this treatment. This finding is consistent with recent data by Horev et al. [73] who compared measurements of carotid stenosis severity using iQA and CTA. These investigators demonstrated that out of 90 patients with significant stenosis on CTA (thus being candidates for CEA), only 70 had a significant stenosis on iQA. Thus, the CTA overestimation error of “% diameter stenosis” wrongly classified 22% of lesions (patients) to the revascularization cohort; a finding consistent with our results (Fig. 3). Our findings support the notion of Horev et al. [73] that despite ongoing radiological progress, the specificity of CTA in accurately assessing carotid stenosis remains relatively low; consequently, patients could be referred for unnecessary CEA surgery and may become exposed to associated potential complications [73].
Invasive angiography correlated best with IVUS imaging. This is important because invasive angiography has been the pivotal imaging technique in initial trials of carotid revascularization in primary and secondary stroke prevention that provided basis for clinical guidelines [14, 15] In more recent quality trials such as CREST-1 [26] or ACT-1 [24] intraarterial angiography has been employed as a prevailing technique in case of discrepancies in non-invasive imaging. IVUS is an invasive technique, and it would be impractical and costly to routinely perform IVUS in patients referred for carotid revascularization. IVUS, as the ‘final’ verification technique will be reserved for patients in whom invasive angiography is ambiguous.
Conclusions
Physicians should be aware of the variability in carotid stenosis severity determined using different imaging modalities. The stenosis severity evaluation method(s) should be taken into consideration when applying clinical trial data as the basis for clinical decision-making.
References
Brinjikji W, Huston J, Rabinstein AA, Kim GM, Lerman A, Lanzino G (2016) Contemporary carotid imaging: from degree of stenosis to plaque vulnerability. J Neurosurg 124(1):27–42. https://doi.org/10.3171/2015.1.JNS142452
Aboyans V, Ricco JB, Bartelink MLEL et al (2018) Editor’s Choice – 2017 ESC guidelines on the diagnosis and treatment of peripheral arterial diseases, in collaboration with the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg 55(3):305–368. https://doi.org/10.1016/j.ejvs.2017.07.018
Bonati LH, Kakkos S, Berkefeld J et al (2021) European Stroke Organisation guideline on endarterectomy and stenting for carotid artery stenosis. Eur Stroke J 6(2):I–XLVII. https://doi.org/10.1177/23969873211012121
Thammongkolchai T, Riaz A, Sundararajan S (2017) Carotid stenosis: role of plaque morphology in recurrent stroke risk. Stroke 48(8):e197–e199. https://doi.org/10.1161/STROKEAHA.117.017779
Kamtchum-Tatuene J, Noubiap JJ, Wilman AH, Saqqur M, Shuaib A, Jickling GC (2020) Prevalence of high-risk plaques and risk of stroke in patients with asymptomatic carotid stenosis: a meta-analysis. JAMA Neurol 77(12):1524–1535. https://doi.org/10.1001/JAMANEUROL.2020.2658
Hosseini AA, Simpson RJ, Altaf N, Bath PM, Macsweeney ST, Auer DP (2017) Magnetic resonance imaging plaque hemorrhage for risk stratification in carotid artery disease with moderate risk under current medical therapy. Stroke 48(3):678–685. https://doi.org/10.1161/STROKEAHA.116.015504
Paprottka KJ, Saam D, Rübenthaler J et al (2017) Prevalence and distribution of calcified nodules in carotid arteries in correlation with clinical symptoms. Radiol Med 122(6):449–457. https://doi.org/10.1007/S11547-017-0740-Z
Svoboda N, Voldřich R, Mandys V et al (2022) Histological analysis of carotid plaques: the predictors of stroke risk. J Stroke Cerebrovasc Dis. https://doi.org/10.1016/J.JSTROKECEREBROVASDIS.2021.106262
Nakagawa I, Kotsugi M, Park HS et al (2021) Near-infrared spectroscopy carotid plaque characteristics and cerebral embolism in carotid artery stenting. EuroIntervention 17(7):599–606. https://doi.org/10.4244/EIJ-D-20-01050
Štěchovský C, Hájek P, Roland R, Horváth M, Veselka J (2021) Long-term changes after carotid stenting assessed by intravascular ultrasound and near-infrared spectroscopy. Cardiovasc Diagn Ther 11(6):1180. https://doi.org/10.21037/CDT-21-160
Kleindorfer DO, Towfighi A, Chaturvedi S et al (2021) Guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American Heart Association/American Stroke Association. Stroke 2021:E364–E467. https://doi.org/10.1161/STR.0000000000000375
AbuRahma AF, Avgerinos ED, Chang RW et al (2022) Society for Vascular Surgery clinical practice guidelines for management of extracranial cerebrovascular disease. J Vasc Surg 75(1S):4S-22S. https://doi.org/10.1016/J.JVS.2021.04.073
Naylor AR, Rantner B, Ancetti S et al (2022) European society for vascular surgery (ESVS) 2023 Clinical practice guidelines on the management of atherosclerotic carotid and vertebral artery disease. Eur J Vasc Endovasc Surg https://doi.org/10.1016/J.EJVS.2022.04.011
Taylor DW, Haynes RB, Sackett DL et al (1991) Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 325(7):445–453. https://doi.org/10.1056/NEJM199108153250701
Foster DS (1995) Endarterectomy for asymptomatic carotid artery stenosis. JAMA J Am Med Assoc 274(19):1505b–11505. https://doi.org/10.1001/jama.274.19.1505b
Willinsky RA, Taylor SM, TerBrugge K, Farb RI, Tomlinson G, Montanera W (2003) Neurologic complications of cerebral angiography: Prospective analysis of 2,899 procedures and review of the literature. Radiology 227(2):522–528. https://doi.org/10.1148/radiol.2272012071
Choudhri O, Schoen M, Mantha A et al (2016) Increased risk for complications following diagnostic cerebral angiography in older patients: trends from the Nationwide Inpatient Sample (1999–2009). J Clin Neurosci 32:109–114. https://doi.org/10.1016/J.JOCN.2016.04.007
Fifi JT, Meyers PM, Lavine SD et al (2009) Complications of modern diagnostic cerebral angiography in an academic medical center. J Vasc Interv Radiol 20(4):442–447. https://doi.org/10.1016/J.JVIR.2009.01.012
Kaufmann TJ, Huston J, Mandrekar JN, Schleck CD, Thielen KR, Kallmes DF (2007) Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 243(3):812–819. https://doi.org/10.1148/RADIOL.2433060536
Serruys PW, Reiber JHC, Wijns W et al (1984) Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. Am J Cardiol 54(6):482–488. https://doi.org/10.1016/0002-9149(84)90235-2
Escaned J, Foley DP, Haase J et al (1993) Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques. Am Heart J 126(6):1326–1333. https://doi.org/10.1016/0002-8703(93)90530-M
Saxena A, Ng EYK, Lim ST (2019) Imaging modalities to diagnose carotid artery stenosis: progress and prospect. Biomed Eng. https://doi.org/10.1186/s12938-019-0685-7
Halliday A, Mansfield A, Marro J et al (2004) Prevention of disabling and fatal strokes by successful carotid endarterectomy in patients without recent neurological symptoms: randomised controlled trial. Lancet 363(9420):1491–1502. https://doi.org/10.1016/S0140-6736(04)16146-1
Rosenfield K, Matsumura JS, Chaturvedi S et al (2016) Randomized trial of stent versus surgery for asymptomatic carotid stenosis. N Engl J Med 374(11):1011–1020. https://doi.org/10.1056/NEJMOA1515706/SUPPL_FILE/NEJMOA1515706_DISCLOSURES.PDF
Halliday A, Bulbulia R, Bonati LH et al (2021) Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy. Lancet (London, England) 398(10305):1065. https://doi.org/10.1016/S0140-6736(21)01910-3
Sheffet AJ, Roubin G, Howard G et al (2010) Design of the carotid revascularization endarterectomy vs. stenting trial (CREST). Int J Stroke 5(1):40–46. https://doi.org/10.1111/J.1747-4949.2009.00405.X
Long A, Lepoutre A, Corbillon E, Branchereau A (2002) Critical review of non- or minimally invasive methods (duplex ultrasonography, MR- and CT-angiography) for evaluating stenosis of the proximal internal carotid artery. Eur J Vasc Endovasc Surg 24(1):43–52. https://doi.org/10.1053/ejvs.2002.1666
Nicolaides AN, Shifrin EG, Bradbury A et al (1996) Angiographic and duplex grading of internal carotid stenosis: Can we overcome the confusion? J Endovasc Surg 3(2):158–165. https://doi.org/10.1583/1074-6218(1996)003%3c0158:AADGIC%3e2.0.CO;2
Jogestrand T, Fredén-Lindqvist J, Lindqvist M, Lundgren S, Tillman AS, Zachrisson H (2016) Discrepancies in recommended criteria for grading of carotid stenosis with ultrasound. Clin Physiol Funct Imaging 36(4):326–329. https://doi.org/10.1111/cpf.12236
Waller BF, Pinkerton CA, Slack JD (1992) Intravascular ultrasound: a histological study of vessels during life. The new “gold standard” for vascular imaging. Circulation 85(6):2305–2310. https://doi.org/10.1161/01.CIR.85.6.2305
Bluth EI, Stavros AT, Marich KW, Wetzner SM, Aufrichtig D, Baker JD (1988) Carotid duplex sonography: a multicenter recommendation for standardized imaging and Doppler criteria. Radiographics 8(3):487–506. https://doi.org/10.1148/RADIOGRAPHICS.8.3.3289100
Grant EG, Benson CB, Moneta GL et al (2003) Carotid artery stenosis: gray-scale and Doppler US diagnosis—Society of Radiologists in Ultrasound Consensus Conference1. Radiology 229(2):340–346. https://doi.org/10.1148/RADIOL.2292030516
Oates CP, Naylor AR, Hartshorne T et al (2009) Joint recommendations for reporting carotid ultrasound investigations in the United Kingdom. Eur J Vasc Endovasc Surg 37(3):251–261. https://doi.org/10.1016/j.ejvs.2008.10.015
Filis KA, Arko FR, Johnson BL et al (2002) Duplex ultrasound criteria for defining the severity of carotid stenosis. Ann Vasc Surg 16(4):413–421. https://doi.org/10.1007/S10016-001-0175-8
Ota H, Takase K, Rikimaru H et al (2005) Quantitative vascular measurements in arterial occlusive disease. Radiographics 25(5):1141–1158. https://doi.org/10.1148/RG.255055014
Alexandrov AV, Bladin CF, Maggisano R, Norris JW (1993) Measuring carotid stenosis. Time for a reappraisal. Stroke 24(9):1292–1296. https://doi.org/10.1161/01.STR.24.9.1292
Latchaw RE, Alberts MJ, Lev MH et al (2009) Recommendations for imaging of acute ischemic stroke: a scientific statement from the American heart association. Stroke 40(11):3646–3678. https://doi.org/10.1161/STROKEAHA.108.192616
Diethrich EB, Margolis MP, Reid DB et al (2007) Virtual Histology Intravascular Ultrasound Assessment of Carotid Artery Disease: The Carotid Artery Plaque Virtual Histology Evaluation (CAPITAL) Study. J Endovasc Ther 14(5):676–686. https://doi.org/10.1177/152660280701400512
Musialek P, Dabrowski W, Mazurek A et al (2020) Quantitative Virtual Histology for In Vivo Evaluation of Human Atherosclerosis—a Plaque Biomechanics-Based Novel Image Analysis Algorithm: validation and applications to atherosclerosis research. In: Intravascular ultrasound. Elsevier, pp 71–96. https://doi.org/10.1016/B978-0-12-818833-0.00005-9
Mazurek A, Partyka L, Trystula M et al (2019) Highly-calcific carotid lesions endovascular management in symptomatic and increased-stroke-risk asymptomatic patients using the CGuardTM dual-layer carotid stent system: analysis from the PARADIGM study. Catheter Cardiovasc Interv 94(1):149–156. https://doi.org/10.1002/CCD.28219
Musialek P, Pieniazek P, Tracz W et al (2012) Safety of embolic protection device-assisted and unprotected intravascular ultrasound in evaluating carotid artery atherosclerotic lesions. Med Sci Monit. https://doi.org/10.12659/msm.882452
Zacharatos H, Hassan AE, Qureshi AI (2010) Intravascular ultrasound: principles and cerebrovascular applications. Am J Neuroradiol 31(4):586–597. https://doi.org/10.3174/ajnr.A1810
Lee JT, White RA (2004) Basics of intravascular ultrasound: an essential tool for the endovascular surgeon. Semin Vasc Surg 17(2):110–118. https://doi.org/10.1053/j.semvascsurg.2004.03.009
Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327(8476):307–310. https://doi.org/10.1016/S0140-6736(86)90837-8
Mohebali J, Patel VI, Romero JM et al (2015) Acoustic shadowing impairs accurate characterization of stenosis in carotid ultrasound examinations. J Vasc Surg 62(5):1236–1244. https://doi.org/10.1016/J.JVS.2015.06.137
Morales MM, Anacleto A, Filho CM, Ledesma S, Aldrovani M, Wolosker N (2019) Peak systolic velocity for calcified plaques fails to estimate carotid stenosis degree. Ann Vasc Surg 59:1–4. https://doi.org/10.1016/j.avsg.2018.12.086
Wardlaw JM, Lewis S (2005) Carotid stenosis measurement on colour Doppler ultrasound: agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement. Eur J Radiol 56(2):205–211. https://doi.org/10.1016/j.ejrad.2005.04.021
Warlow C, Farrell B, Fraser A, Sandercock P, Slattery J (1998) Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST). Lancet 351(9113):1379–1387. https://doi.org/10.1016/s0140-6736(97)09292-1
Rosenfield K, Matsumura J, Chaturvedi S et al (2016) Randomized trial of stent versus surgery for asymptomatic carotid stenosis. N Engl J Med 374:1011–1020
Met R, Bipat S, Legemate DA, Reekers JA, Koelemay MJW (2009) Diagnostic performance of computed tomography angiography in peripheral arterial disease a systematic review and meta-analysis. JAMA J Am Med Assoc 301(4):415–424. https://doi.org/10.1001/jama.301.4.415
Jahromi AS, Cinà CS, Liu Y, Clase CM (2005) Sensitivity and specificity of color duplex ultrasound measurement in the estimation of internal carotid artery stenosis: a systematic review and meta-analysis. J Vasc Surg 41(6):962–972. https://doi.org/10.1016/j.jvs.2005.02.044
Preiss JE, Itum DS, Reeves JG et al (2015) Carotid duplex criteria for patients with contralateral occlusion. J Surg Res 193(1):28–32. https://doi.org/10.1016/j.jss.2014.08.037
Van Everdingen KJ, Van der Grond J, Kappelle LJ (1998) Overestimation of a stenosis in the internal carotid artery by duplex sonography caused by an increase in volume flow. J Vasc Surg 27(3):479–485. https://doi.org/10.1016/S0741-5214(98)99999-2
Chappell FM, Wardlaw JM, Young GR et al (2009) Carotid artery stenosis: accuracy of noninvasive tests - individual patient data meta-analysis. Radiology 251(2):493–502. https://doi.org/10.1148/radiol.2512080284
Arous EJ, Judelson DR, Malka KT et al (2019) Carotid duplex velocity criteria recommended by the Society of Radiologists in Ultrasound and Endorsed by the Intersocietal Accreditation Commission Lack Predictive Ability for Identifying High-Grade Carotid Artery Stenosis. Ann Vasc Surg 61:227–232. https://doi.org/10.1016/j.avsg.2019.05.051
Bryant C, Pugh N, Coleman D, Morris R, Williams P, Humphries K (2013) Comparison of Doppler ultrasound velocity parameters in the determination of internal carotid artery stenosis. Ultrasound 21(3):124–131. https://doi.org/10.1177/1742271X13496680
Norris JW, Morriello F, Rowed DW, Maggisano R (2003) Vascular imaging before carotid endarterectomy. Stroke. https://doi.org/10.1161/01.STR.0000069423.21542.61
Zavanone C, Ragone E, Samson Y (2012) Concordance rates of Doppler ultrasound and CT angiography in the grading of carotid artery stenosis: a systematic literature review. J Neurol 259(6):1015–1018. https://doi.org/10.1007/s00415-011-6265-9
Von Reutern GM, Goertler MW, Bornstein NM et al (2012) Grading carotid stenosis using ultrasonic methods. Stroke 43(3):916–921. https://doi.org/10.1161/STROKEAHA.111.636084
Wardlaw JM, Chappell FM, Stevenson M et al (2006) Accurate, practical and cost-effective assessment of carotid stenosis in the UK. Health Technol Assess. https://doi.org/10.3310/HTA10300
Wardlaw J, Chappell F, Best J, Wartolowska K, Berry E (2006) Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 367(9521):1503–1512. https://doi.org/10.1016/S0140-6736(06)68650-9
Columbo JA, Zwolak RM, Arous EJ, Goodney PP, Lilly MP, Welch HG (2020) Variation in ultrasound diagnostic thresholds for carotid stenosis in the United States. Circulation 141(12):946–953. https://doi.org/10.1161/CIRCULATIONAHA.119.043963
Shaw JA, Kingwell BA, Walton AS et al (2002) Determinants of coronary artery compliance in subjects with and without angiographic coronary artery disease. J Am Coll Cardiol 39(10):1637–1643. https://doi.org/10.1016/S0735-1097(02)01842-9
Brodoefel H, Burgstahler C, Tsiflikas I et al (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247(2):346–355. https://doi.org/10.1148/radiol.2472070906
Meng L, Cui L, Cheng Y et al (2009) Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol 10(4):347–354. https://doi.org/10.3348/kjr.2009.10.4.347
Kotsugi M, Takayama K, Myouchin K et al (2017) Carotid artery stenting: investigation of plaque protrusion incidence and prognosis. JACC Cardiovasc Interv 10(8):824–831. https://doi.org/10.1016/J.JCIN.2017.01.029
Okazaki T, Sakamoto S, Shinagawa K et al (2019) Detection of in-stent protrusion (ISP) by intravascular ultrasound during carotid stenting: usefulness of stent-in-stent placement for ISP. Eur Radiol 29(1):77–84. https://doi.org/10.1007/S00330-018-5636-3
Clark DJ, Lessio S, O’Donoghue M, Schainfeld R, Rosenfield K (2004) Safety and utility of intravascular ultrasound-guided carotid artery stenting. Catheter Cardiovasc Interv 63(3):355–362. https://doi.org/10.1002/CCD.20188
Musialek P, Rosenfield K, Siddiqui A, Grunwald IQ. Thrombosis and haemostasis carotid stenosis and stroke: medicines, stents, surgery-"Wait-and-See" or protect? Thromb Haemost. 2022 https://doi.org/10.1055/a-1952-1159
Arous EJ, Simons JP, Flahive JM et al (2015) National variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic carotid artery stenosis. J Vasc Surg 62(4):937–944. https://doi.org/10.1016/J.JVS.2015.04.438
Musialek P (2013) Virtual histology intravascular ultrasound evaluation of atherosclerotic carotid artery stenosis: time for fully quantitative image analysis. J Endovasc Ther 20(4):589–594. https://doi.org/10.1583/13-4303L.1
Alfonso F, Hernando L, Dutary J (2010) Virtual histology assessment of atheroma at coronary bifurcations: colours at the crossroads? Euro-Intervention 6:295–301. https://doi.org/10.4244/EIJV6I3A50. (PMID: 20884405)
Horev A, Honig A, Cohen JE et al (2021) Overestimation of carotid stenosis on CTA - real world experience. J Clin Neurosci 85:36–40. https://doi.org/10.1016/J.JOCN.2020.12.018
Mannil M, Ramachandran J, Vittoria De Martini I et al (2017) Modified dual-energy algorithm for calcified plaque removal: evaluation in carotid computed tomography angiography and comparison with digital subtraction angiography. Invest Radiol 52(11):680–685. https://doi.org/10.1097/RLI.0000000000000391
Funding
This work was supported by the National Committee for Scientific Research (PL-N402-184234), the Polish Cardiac Society/Servier Clinical Research in Atherosclerosis grant (to PM), the National Science Centre (2022/06/X/NZ5/00583) and Jagiellonian University Medical College (K/ZDS/007819). The authors have no relevant financial or non-financial interests to disclose.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation and data collection were performed by Lukasz Tekieli, Anna Kablak-Ziembicka, Wladyslaw Dabrowski, Karolina Dzierwa, Zbigniew Moczulski, Malgorzata Urbanczyk-Zawadzka, Adam Mazurek, Piotr Paluszek, Maciej Krupinski, Tadeusz Przewlocki, Piotr Pieniazek and Piotr Musialek. Statistical analysis was performed by Justyna Stefaniak. The first draft of the manuscript was written by Lukasz Tekieli and Piotr Musialek, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors have no relevant financial or non-financial interests to disclose.
Ethical approval
This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Jagiellonian University Ethics Committee (402/184234) and all patients provided written informed consent to participate.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Tekieli, L., Kablak-Ziembicka, A., Dabrowski, W. et al. Imaging modality-dependent carotid stenosis severity variations against intravascular ultrasound as a reference: Carotid Artery intravasculaR Ultrasound Study (CARUS). Int J Cardiovasc Imaging 39, 1909–1920 (2023). https://doi.org/10.1007/s10554-023-02875-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-023-02875-1