Abstract
Here we investigated how a coating of intravascular balloon with paclitaxel (drug-coated balloon; DCB, Freeway™) impacted porcine peripheral artery vascular function and remodeling. Domestic swine (n = 54) underwent percutaneous overstretch balloon dilation of femoral and iliac arteries, controlled by angiography and optical coherence tomography (OCT). Paclitaxel tissue uptake was measured at 1 h and 1, 3, and 9 days post-dilation. At these time-points and at 32 ± 2 days, vascular function of the dilated arteries was assessed using the organ chamber model. Neointimal growth and remodeling indices were determined using OCT and histology at 32 ± 2 days. Intima and media fibrosis were quantified by picrosirius red staining. Post-inflation femoral artery tissue drug levels were 460 ± 214, 136 ± 123, 14 ± 6, and 0.1 ± 0.1 ng/mg at 1 h and 1, 3, and 9 days, respectively. Compared to plain balloon, Freeway™ resulted in a significantly smaller neointimal area (P < 0.05), less tunica intima (8.0 ± 5.4 vs 14.2 ± 4.7 %) and media fibrosis (15.6 ± 7.7 vs 24.5 ± 5.4 %), and less femoral artery constrictive remodeling (remodeling index: 1.08 ± 0.08 vs 0.94 ± 0.08). The DCB was associated with significantly increased vasoconstrictor tone and endothelium-dependent vasodilation impairment shortly after post-overstretch injury. Overall, DCB dilation of peripheral arteries resulted in high drug uptake into arterial tissue. Compared with the plain balloon, the DCB was associated with decreased vessel wall fibrosis after balloon overstretch injury, and reduced degrees of constrictive remodeling and neointimal hyperplasia.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
1 Introduction
As treatment for atherosclerotic peripheral artery disease, percutaneous transluminal angioplasty shows limited success due to high restenosis rates [1–3], with 1-year patency rates of 75–85 % after bare-metal stent (BMS) placement [4–6]. Studies testing the implantation of drug-eluting stents (DES) in the superficial femoral artery to prevent restenosis have shown conflicting results, with DES showing advantages over BMS in the short term (6 months) [3], but with diminishing benefits over a longer time [6]. Sirolimus-coated stents are more consistently superior for treating focal infrapopliteal lesions when compared with BMS [7]. In the Zilver PTX randomized study of patients with peripheral artery disease, implantation of polymer-free DES led to improved 12-month results compared to balloon dilation, with similar superiority results when balloon dilation was followed by provisional DES stenting [8].
The use of drug-coated balloons (DCBs) represents an alternative approach to DES for local antiproliferative drug delivery into the vessel wall [9–13]. DCB employment in peripheral endovascular procedures has been successfully demonstrated in pre-clinical [14–17] and clinical [18–24] studies.
Optical coherence tomography (OCT) has recently been introduced into clinical practice to allow in vivo visualization of stent strut coverage with neo-endothelium [25]. Correct imaging of femoral or iliac vessels is technically challenging due to the large size of the peripheral arteries. Accordingly, current publications describing OCT use in peripheral arteries are limited to case reports [26, 27] and ex vivo imaging [28].
We previously demonstrated that drug deposition in coronary arteries leads to time-dependent impairment of vascular function, despite decreased restenosis [29]. Unlike in coronary arteries, the long atherosclerotic lesions of human peripheral vessels can exhibit both adaptive and constrictive remodeling within a single vessel [30], carrying potential consequences of both vessel thrombotic occlusion and severe restenosis. No systematic investigation has yet reported how peripheral arterial wall remodeling is impacted by percutaneous intervention with a paclitaxel-coated balloon, and any related mechanical injury.
The present pre-clinical investigation aimed to assess the vascular response to antiproliferative drug accumulation in the peripheral arteries after balloon dilation with the paclitaxel-coated balloon Freeway™ (Eurocor, Germany). The impact was examined in terms of vessel remodeling and vasodilatory or vasoconstrictive capacity of the femoral or iliac arteries compared to with plain balloon dilation.
2 Materials and methods
2.1 Local drug-delivery device
The Freeway™ balloon is a peripheral dilation balloon for use in humans. Its surface is coated with 3.0 µg/mm2 paclitaxel using the shellac-coating technique. The balloon’s tri-fold design protects the drug coating from early wash-off into the peripheral circulation while the balloon is introduced.
2.2 Experimental design
This study was approved by the Ethical Committee on Animal Experiments at the University of Kaposvar, Hungary. Our study protocol conformed to the “Position of the American Heart Association on Research Animal Use,” adopted by the AHA on November 11, 1984.
The design of this prospective study is illustrated in Fig. 1, and described in detail in the Supplementary Materials and methods. Briefly, domestic pigs (weight 30–40 kg, n = 54) were pre-treated with 300 mg clopidogrel and 250 mg acetylsalicylic acid. After overnight fasting, the pigs were anesthetized for the peripheral intervention. Into the right and left femoral and iliac arteries (four vessels in each pig), we introduced the Freeway™ or plain balloon (femoral: diameter of 5.0 or 6.0 mm and length of 20 mm; iliac: diameter of 7.0 or 8.0 mm and length of 40 mm). The balloons were then inflated with 6–12 atm pressure to achieve a 1.3:1 balloon/artery ratio, producing overstretch injury. Balloon inflation was controlled by angiography, and the inflated balloon size was related to the vessel size displayed by the baseline angiography. The duration of balloon inflation was 60 or 120 s, depending on the experimental setup. The animals were allowed to recover after the procedure. Upon completing the predetermined follow-up time, the animals were humanely euthanized with saturated potassium chloride.
2.2.1 Pharmacokinetic study
Blood samples were taken at 5, 10, 20, and 60 min after the interventional procedure. At 1 h and 1, 3, and 9 days of follow-up, the paclitaxel concentration in femoral and iliac arterial tissue was measured using high-performance liquid chromatography (AnaKat Institut für Biotechnologie GmbH, Berlin, Germany) [31, 32]. In five animals, the proximal and distal reference segments of five iliac and femoral arteries (2-min dilation groups) were dissected. All balloon remnants were stored for measurements of paclitaxel on the surface.
2.2.2 Vascular response study measuring vasoconstrictor tone and endothelium-dependent and -independent vasodilation
Vasomotor reactions—including contraction, and endothelium-dependent and -independent vasodilation—were measured using the organ chamber model, as previously described [29] (Supplementary Materials and Methods).
2.2.3 Vascular remodeling study
Our investigation of vascular remodeling included OCT and histology analyses. During a follow-up period of 32 ± 2 days, the pigs received a daily dose of 75 mg clopidogrel and 100 mg acetylsalicylic acid. At the end of the study, angiography and OCT imaging were performed, and then the animals were euthanized. For histopathological and histomorphometric analyses, the peripheral arteries were flushed with 100 mL saline, followed by pressure fixation in 4 % buffered formaldehyde at 100–110 mmHg for 30 min.
2.3 OCT imaging and analysis
For OCT imaging, a Dragonfly™ catheter (St. Jude Medical, Lightlab Imaging, Inc., Westford, MA) was placed 3 cm distal to the affected peripheral artery segment, and images were acquired via motorized pullback [25]. The images were digitally stored using the ILUMIEN System (St. Jude Medical, St. Paul, MN). The large artery size prohibited blood clearance with a single contrast medium flush. Thus, OCT image acquisition was combined with proximal gentle balloon occlusion of the artery using low balloon inflation pressure [26]. The analysis is described in detail in the Supplementary Materials and Methods. Briefly, for the lesion with the highest degree of stenosis, we determined the remodeling index as the IEM area of the lesion divided by the IEM area of the reference segment (mean IEM of the proximal and distal reference segments within 1 cm of the lesion edge) [25]. A remodeling index of >1 or <1 was considered to indicate adaptive or constrictive remodeling, respectively.
2.4 Histopathology and histomorphometry
The formalin-fixed dilated segments were cut into distal, mid, and proximal segments. These pieces were embedded in paraffin, cut into 4– 6-µm-thick slices, and routinely stained with hematoxylin–eosin and modified Movat’s pentachrome and picrosirius staining. We used planimetry to quantify fibrosis of the tunica intima, media, and adventitia as described elsewhere [33]. All histopathological, histomorphometric, and immunohistochemical analyses were performed in accordance with published guidelines by experienced investigators who were blinded to the treatment (Supplementary Materials and Methods). The remodeling index was calculated as the external elastic lamina (EEL) area of the lesion with the highest grade of stenosis divided by the EEL area of the reference segment (mean value of the proximal and distal reference EEL area).
2.5 Statistics
The continuous parameters of the angiographic, histologic, and physiologic analyses are expressed as mean ± standard deviation. Tissue and plasma paclitaxel levels are presented as mean ± standard error. The continuous variables of the plain balloon and Freeway™ groups were compared using the two-sided Student’s t test with a significance level of 0.05. All measurements were performed offline by an independent observer who was blinded to the randomization group. For all OCT images, the lumen area of the selected region of interest was repeatedly assessed by one observer, as well as assessed by a second observer, enabling calculation of the intra- and inter-observer variability of the OCT measurements. Statistical analyses were performed using SPSS for Macintosh version 19.
3 Results
Figure 2 depicts the baseline anatomy of the porcine superficial femoral and iliac arteries. The common iliac artery was longer and wider than the femoral arteries, having a size similar to human femoral arteries and thus being better suited for testing human DCBs. The iliac arteries are more elastic, with collagen and elastin fibers dominating in the tunica media, and relatively few smooth muscle fibers. In contrast, the femoral arteries are muscular-type arteries, showing predominant content of smooth muscle cells.
Overstretch balloon dilation led to severe vessel injury in each case, as confirmed by angiography, OCT, and histology (Figs. 3, 4, 5). OCT images showed severe vessel wall injury after overstretch balloon dilation, including dissection, and parietal and intraluminal floating thrombi, but without acute artery closure. At 1 h after balloon dilation, fluorescent staining of the femoral arterial cross-sections showed cell-rich (plain balloon) or cell-poor (Freeway™) intraluminal thrombus formation, and massive expression of tumor necrosis factor-alpha by the inflammatory cells and platelets (Figs. 3, 4, 5).
3.1 Paclitaxel accumulation in the peripheral vessel wall
Compared with 1-min dilation, the 2-min inflation time was definitively more effective in terms of tissue retention of the drug in both arteries (Figs. 6, 7). Therefore, we used the 2-min balloon inflation time in our vascular response and remodeling studies, which is also the more commonly used inflation time in human peripheral interventions.
Following 2-min balloon inflation of the femoral arteries, the paclitaxel concentration at the 1-h follow-up was 36.9 ± 17.8 ng/mg in the proximal reference segments and 17.0 ± 6.3 ng/mg in the distal reference segments. As expected, the plasma paclitaxel concentration decreased with time after DCB use. At 5 and 10 min after a 1-min balloon inflation, the paclitaxel concentrations decreased from 9.2 ± 4.5 to 0 ng/mL. At 5, 10, 20, and 60 min after a 2-min balloon inflation, the paclitaxel concentrations were 14.6 ± 6.8, 10.2 ± 4.9, 7.7 ± 3.1, and 0.6 ± 0.4 ng/mL, respectively. The percentages of paclitaxel remaining on the balloon surface after the procedures were 53.2 ± 9.8 and 30.9 ± 4.3 % following 1- and 2-min dilation of the femoral arteries, respectively.
3.2 Vessel remodeling study
Quantitative peripheral angiography revealed that Freeway™ dilation was associated with a significant percentage of decrease in the stenosis diameter of the femoral arteries, and with a trend toward less stenosis of the iliac arteries (Tables 1, 2). Among ten selected OCT images, the intra- and inter-observer variability values were r = 0.95 and r = 0.91 (P < 0.001), respectively. At 32 ± 2 days, OCT imaging revealed that Freeway™ was associated with a significantly lower percentage area of stenosis in both the femoral and iliac arteries (Tables 3, 4). With the use of plain balloons, OCT indicated vessel constriction (Figs. 4, 5). Quantitative OCT images revealed a remodeling index of <1 in femoral arteries dilated with a plain balloon, suggesting constrictive remodeling (Tables 3, 4). No meaningful arterial remodeling was observed in the elastic-type iliac arteries (Tables 3, 4).
Histopathological analyses showed similar inflammation and injury scores between the two groups. Both device groups showed complete endothelialization in femoral arteries. In the iliac arteries, endothelialization was complete in the plain balloon group and was 95 ± 5 % with the Freeway™ balloon (Tables 5, 6). No vessel calcification was observed. Histomorphometric analyses of both arteries revealed that the Freeway™ group showed a significantly larger lumen area, smaller neointimal area, and lower percentage area of stenosis compared to these values in the plain balloon group (Tables 7, 8). Alpha-actin staining revealed invasion of smooth muscle cells into the intima in the femoral arteries after plain balloon use, in contrast with the Freeway™-dilated arteries (Fig. 6). Additionally, arterial wall exposure to paclitaxel inhibited fibrin deposition in the tunica intima and media in the femoral arteries (Fig. 8), and in the intima in the iliac arteries (Fig. 9).
3.3 Physiological response of the peripheral arteries to balloon dilation
Enhanced endothelin-induced vasoconstriction in the Freeway™-treated peripheral arteries was more pronounced in the femoral arteries than in the iliac arteries, and showed rapid normalization at 3 days post-intervention (Figs. 8, 9). The endothelium-dependent vasodilator reaction was profoundly impaired during the first 3 days in the femoral vessels but not in the iliac arteries, with no difference between the two balloon types. Endothelium-independent vasodilation did not change after balloon injury in the femoral or iliac arteries (Figs. 8, 9).
4 Discussion
Our present study results provide novel data with translational value regarding the use of DCB in clinical practice. We report that arterial dilation with the DCB Freeway™ inhibited fibrin accumulation in the tunica intima and media of the femoral arteries, leading to significantly less constrictive remodeling of the injured vessel. However, tissue uptake of the drug into the vessel wall after percutaneous intervention resulted in a predisposition to vessel constriction in both the iliac and femoral arteries, as well as impaired endothelium-dependent vasodilation of the femoral arteries. Our present report also includes the application of high-resolution OCT imaging for in vivo display of peripheral vascular injury following the use of an intravascular device, which demonstrated non-flow-limiting dissection and thrombus formation with an inflammatory reaction. Finally, we report the pathophysiological differences between femoral and iliac arteries in response to intravascular intervention using either the plain balloon or DCB (Table 9).
4.1 Tissue and plasma drug levels after balloon catheter-derived delivery: comparison with data from the literature
Our present results showed that use of the Freeway™ DCB led to paclitaxel accumulation in both the femoral and iliac arteries, and the longitudinal distribution of this drug both proximal and distal to the balloon dilation site. Yazdani et al. previously reported much lower paclitaxel levels in the arteria femoralis tissue of healthy domestic swine following their use of the Lutonix drug-coated balloon (Lutonix Inc., New Hope, MN). However, in their study, the femoral arteries were dilated without overstretch injury for an inflation time of only 30 s [34]. In another study, Buszmann et al. measured paclitaxel levels at 1 h after 30-s dilation with the Cotavance DCB (MEDRAD Interventional, Indianola, PA) in hypercholesterolemic domestic pigs with in-stent restenosis of the peripheral arteries, and reported paclitaxel tissue uptake of <50 ng/mg tissue [17]. Comparatively, our present study showed paclitaxel uptake of 143 ± 60 and 460 ± 214 ng/mg femoral artery tissue at 1 h after balloon dilation with a 1- or 2-min inflation time, respectively. Granada et al. [16] reported that histology, but not quantitative angiography, is sufficiently sensitive to determine the effect of a zotarolimus-coated balloon for restenosis prevention. Like in our study, Kolachalama et al. demonstrated that the tissue drug level of zotarolimus in peripheral arteries was dependent on the balloon inflation time [35].
In contrast with previously published peripheral DCB studies, in our present study, we separately analyzed the iliac and femoral arteries because these arteries differ in structure and in their physiological responses to injury (as shown in our study). We also applied optical imaging to examine the morphological effects of balloon inflation in the femoro-iliac arteries. OCT images of peripheral arteries revealed severe post-dilation vessel injury, including dissections and luminal thrombi, and proved to be more sensitive than angiography for the assessing lumen morphology and dimensions, similar to histology.
It appears that a long presence and high concentration of the drug in the arterial wall are crucial for inhibition of neointimal proliferation and restenosis [36, 37]. In our study, the paclitaxel tissue level was maintained over 9 days—beyond occurrence of the initial thrombotic and inflammatory processes following vessel trauma from endovascular interventions, and beyond the smooth muscle cell migration and proliferation from the media and adventitia. Longer presence of an antiproliferative drug—especially one with a narrow therapeutic window, like paclitaxel—could result in vascular toxicity, including ectasia of the treated vessels [21]. Our present results showed that a 1-min balloon inflation time in peripheral arteries resulted in an artery tissue paclitaxel level similar to that previously observed in coronary arteries [31, 32]. Due to the potential for untoward cardiac effects from prolonged ischemia, a longer balloon inflation time is not desirable in coronary arteries. Paclitaxel is released into systemic circulation immediately after balloon inflation. The use of a 2-min balloon inflation time led to a gradual decrease in the plasma drug level, corresponding to the plasma paclitaxel clearance half-life [38]. Dose-finding clinical investigations show that a plasma concentration below 6.3 µmol/L (5400 ng/mL; well above the 15 ng/mL maximal level in our study) is not associated with any systemic toxicity [39, 40].
4.2 Vascular remodeling study
Paradoxical arterial (or constrictive) remodeling was first described in femoral arteries by Pasterkamp et al. [41]. Our present experiments revealed that paclitaxel accumulation in the femoral arterial wall inhibited fibrin deposition in the intimal and medial layers. Paclitaxel did not substantially influence the amount of fibrous collagen in the tunica media of the iliac arteries, but it did reduce fibrin deposition in the intima. Thus, the higher post-intervention lumen area may be explained not only by inhibition of smooth muscle cell migration into the intima, but also by prevention of constrictive remodeling. While tissue drug levels are published for other DCB systems, such vessel remodeling and pathophysiological studies have not yet been performed for other DCBs.
4.3 Pathophysiological study
Our physiological investigation revealed that tissue drug level was clearly associated with increased vasoconstrictor tone of the affected vessel. This association was more pronounced in the femoral arteries than in the iliac vessels during the first days following overstretch injury. Dilation with the DCB led to increased vasoconstrictive response in both the iliac and femoral arteries, and notably in vessels with injury scores similar to those of arteries dilated with the plain balloon. Thus, the overstretch injury (denudation) of the arteries was not the only cause of this pathological reaction.
Vascular procedures induce a reflexive, mechanically induced vasospasm. In contrast to the coronary arteries [29], the intact control peripheral vessels showed much lower endothelium-dependent vasodilator capacity. Notably, endothelium-independent (muscular layer) vasodilation was unaffected by the balloon overstretch injury, likely due to the high fibrous collagen tissue content. The results of our previous physiological studies in coronary arteries [29] together with our current findings in peripheral vessels, appear to indicate that the peripheral arteries are much less reactive with regards to contraction and to endothelium-dependent and -independent vasodilation. This fact may be particularly important if coronary devices are tested in rabbit iliac arteries.
4.4 Practical application and translational nature of the study
The Freeway™ DCB is commercially available in Europe and in several non-USA countries for human peripheral artery interventions. However, animal studies of this device still provide a unique opportunity to examine the reaction of the host tissue; to investigate tissue pathology and inflammation; to study drug retention, delivery, kinetics, and toxicology; to assess systemic drug disposition or other harmful effects related to the application of drugs and/or a foreign body; and to further explore their mechanisms of action. These data acquired from animal research can directly lead to improvements of technological concepts and to refinements of intravascular devices. In contrast, human trials typically focus on the safety and efficacy of an interventional therapy, without attaining new information regarding the underlying biology.
Accordingly, in our present animal model of the use of peripheral intravascular DCB, we demonstrated that the drug coating on an intravascular balloon surface did not cause delayed re-endothelialization in peripheral arteries. Thus, in contrast with drug-coated stents, the use of DCB could reduce the duration of dual antiplatelet therapy [36], which is of clinical interest. In cases of non-flow-limiting dissection, the use of a DCB is apparently sufficient to prevent restenosis without provisional stenting in peripheral arteries, thus avoiding stent fractures or foreign body reactions. Moreover, the use of DCBs for peripheral artery dilation prevents unfavorable constrictive remodeling, thereby inhibiting disease progression. It is also notable that the impaired vasoreactivity caused by drug deposition in the arterial wall requires more aggressive post-intervention vasodilatory treatment.
4.5 Limitations
Percutaneous intervention of healthy porcine peripheral arteries cannot mimic the peripheral intervention of atherosclerotic human arteries, and is not entirely comparable with the injury model of familial hypercholesterolemic swine [16]. It was recently proposed that deep acute endothelium injury in hypercholesterolemic swine could be used as an animal model for device assessment [16]. However, the current guidelines for performing pre-clinical tests in coronary and peripheral arteries do not recommend the use of diseased porcine models [34]. Nevertheless, in our present study, visible injury of the peripheral arteries was confirmed by angiography and OCT following gross overdilation. It should also be noted that the pathophysiological response of the denuded artery [16] influences the endothelial uptake of locally delivered drugs. Further limitations of this study are described in the Supplemental Material.
5 Conclusions
Our present results demonstrated the safety and efficacy of the Freeway™ paclitaxel-coated balloon in a preclinical model of overstretch injury in peripheral arteries. The observed beneficial effects of the Freeway™ balloon may be attributed to inhibition of smooth muscle cell migration and neointimal hyperplasia development, as well as prevention of fibrosis of the intima and media, resulting in less constrictive vessel remodeling. We also showed that higher arterial wall paclitaxel concentration was associated with local vasoconstriction and impaired endothelium-dependent vasodilation. Furthermore, our findings show that although high-resolution OCT imaging is technically challenging, it was useful for in vivo display of peripheral vascular injury after intravascular device usage, demonstrating non-flow-limiting dissection and thrombus formation with inflammatory reaction in peripheral arteries.
References
Dormandy JA, Rutherford RB. Management of peripheral arterial disease (pad). tasc working group. Transatlantic inter-society consensus (TASC). J Vasc Surg. 2000;31:S1–296.
Norgren L, Hiatt WR, Dormondy JA, et al. Inter-society consensus for the management of peripheral arterial disease (TASC II). J Vasc Surg. 2007;45(Suppl S):S5A–67A.
Duda SH, Bosiers M, Lammer J, et al. Sirolimus-eluting versus bare nitinol stent for obstructive superficial femoral artery disease: the SIROCCO II trial. J Vasc Interv Radiol. 2005;16:331–8.
Schillinger M, Sabeti S, Loewe C, et al. Balloon angioplasty versus implantation of nitinol stents in the superficial femoral artery. N Engl J Med. 2006;354:1879–88.
Scheinert D, Grummt L, Piokowski M, et al. A novel self-expanding interwoven nitinol stent for complex femoropopliteal lesions: 24-month results oft he SUPERA SFA registry. J Endovasc Ther. 2011;18:745–52.
Duda SH, Bosiers M, Lammer J, et al. Drug-eluting and bare metal stents for the treatment of atherosclerotic lesions in the superficial femoral artery: long-term result from the SIROCCO trial. J Endovasc Ther. 2006;13:701–10.
Scheinert D, Ulrich M, Scheinert S, et al. Comparison of sirolimus-eluting vs. bare-metal stents for the treatment of infrapopliteal obstructions. EuroIntervention. 2006;2:169–74.
Dake MD, Ansel GM, Jaff MR, et al. Paclitaxel-eluting stents show superiority to balloon angioplasty and bare metal stents in femoropopliteal disease: twelve-month Zilver PTX randomized study results. Circ Cardiovasc Interv. 2011;4:495–504.
Gray WA, Granada JF. Drug-coated balloons for the prevention of vascular restenosis. Circulation. 2010;121:72–2680.
Buechel R, Stirnimann A, Zimmer R, et al. Drug-eluting stents and drug-coated balloons in peripheral artery disease. Vasa. 2012;41:48–261.
Krokidis M, Spiliopoulos S, Katsanos K, Sabharwal T. Peripheral applications of drug-coated balloons: past. Cardiovasc Intervent Radiol. 2013;36:281–91.
Kumar A, Brooks SS, Cavanaugh K, Zuckerman B. FDA perspective on objective performance goals and clinical trial design for evaluating catheter-based treatment of critical limb ischemia. J Vasc Surg. 2009;50:1474–6.
Scheller B, Hehrlein C, Bocksch W, et al. Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. N Engl J Med. 2006;355:2113–24.
Albrecht T, Speck U, Baier C, et al. Reduction of stenosis due to intimal hyperplasia after stent supported angioplasty of peripheral arteries by local administration of paclitaxel in swine. Invest Radiol. 2007;42:579–85.
Milewski K, Afari ME, Tellez A, et al. Evaluation of efficacy and dose response of different Paclitaxel-coated balloon formulations in a novel Swine model of iliofemoral in-stent restenosis. JACC Cardiovasc Interv. 2012;5:1081–8.
Granada JF, Milewski K, Zhao H, et al. Vascular response to zotarolimus-coated balloons in injured superficial femoral arteries of the familial hypercholesterolemic Swine. Circ Cardiovasc Interv. 2011;4:447–55.
Buszman PP, Tellez A, Afari ME, et al. Tissue uptake, distribution, and healing response after delivery of paclitaxel via second-generation iopromide-based balloon coating: a comparison with the first-generation technology in the iliofemoral porcine model. JACC Cardiovasc Interv. 2013;6:883–90.
Werk M, Langner S, Reinkensmeier B, et al. Inhibition of restenosis in femoropopliteal arteries: paclitaxel-coated versus uncoated balloon: femoral paclitaxel randomized pilot trial. Circulation. 2008;118:1358–65.
Tepe G, Schnorr B, Albrecht T, et al. Angioplasty of femoral-popliteal arteries with drug-coated balloons: 5-year follow-up of the THUNDER trial. JACC Cardiovasc Interv. 2015;8:102–8.
Werk M, Albrecht T, Meyer DR, et al. Paclitaxel-coated balloons reduce restenosis after femoro-popliteal angioplasty: evidence from the randomized PACIFIER trial. Circ Cardiovasc Interv. 2012;5:831–40.
Schmidt A, Piorkowski M, Werner M, et al. First experience with drug-eluting balloons in infrapopliteal arteries: restenosis rate and clinical outcome. J Am Coll Cardiol. 2011;58:1105–9.
Micari A, Cioppa A, Vadala G, et al. 2-year results of paclitaxel-eluting balloons for femoropopliteal artery disease. JACC Cardiovasc Interv. 2013;6:282–9.
Rosenfield K, Jaff MR, White CJ, et al. Trial of a Paclitaxel-Coated Balloon for femoropopliteal artery disease. N Engl J Med. 2015;373:145–53.
Scheinert D, Schulte KL, Zeller T, et al. Paclitaxel-releasing balloon in femoropopliteal lesions using a BTHC excipient: twelve-month results from the BIOLUX P-I randomized trial. J Endovasc Ther. 2015;22:14–21.
International Working Group for Intravascular Optical Coherence Tomography. (IWG-IVOCT). Consensus standards for acquisition, measurement and reporting of intravascular optical coherence tomography studies. J Am Coll Cardiol. 2012;59:1058–72.
Negi SI, Rosales O. The role of intravascular optical coherence tomography in peripheral percutaneous interventions. J Invasive Cardiol. 2013;25:E51–3.
Stefano GT, Mehanna E, Parikh SA. Imaging a spiral dissection of the superficial femoral artery in high resolution with optical coherence tomography—seeing is believing. Catheter Cardiovasc Interv. 2013;81:568–72.
Meissner OA, Rieber J, Babaryka G, et al. Intravascular optical coherence tomography: comparison with histopathology in atherosclerotic peripheral artery specimens. J Vasc Interv Radiol. 2006;17:343–9.
Plass CA, Sabdyusheva-Litschauer I, Bernhart A, et al. Time course of endothelium-dependent and -independent coronary vasomotor response to coronary balloons and stents: comparison of plain and drug-eluting balloons and stents. JACC Cardiovasc Interv. 2012;5:741–51.
Gyöngyösi M, Strehblow C, Haumer M, et al. Vascular remodeling in atherosclerotic femoral arteries: three-dimensional US analysis. Radiology. 2004;233:366–75.
Posa A, Hemetsberger R, Petnehazy O, et al. Attainment of local drug delivery with paclitaxel-eluting balloon in porcine coronary arteries. Coron Artery Dis. 2008;19:243–7.
Posa A, Nyolczas N, Hemetsberger R, et al. Optimization of drug-eluting balloon use for safety and efficacy: evaluation of the 2nd generation paclitaxel-eluting DIOR-balloon in porcine coronary arteries. Catheter Cardiovasc Interv. 2010;76:395–403.
Vogel B, Siebert H, Hofmann U, Freantz S. Determination of collagen content within picrosirius red stained paraffin-embedded tissue sections using fluorescence microscopy. MethodsX. 2015;2:124–34. doi:10.1016/j.mex.2015.02.007.
Yazdani SK, Pacheco E, Nakano M, et al. Vascular, downstream, and pharmacokinetic responses to treatment with a low dose drug-coated balloon in a swine femoral artery model. Catheter Cardiovasc Interv. 2014;83:132–40.
Kolachalama VB, Pacetti SD, Franses JW, et al. Mechanisms of tissue uptake and retention in zotarolimus-coated balloon therapy. Circulation. 2013;127:2047–55.
Speck U, Cremers B, Kelsch B, et al. Do pharmacokinetics explain persistent restenosis inhibition by a single dose of paclitaxel? Circ Cardiovasc Interv. 2012;5:392–400.
Byrne RA, Joner M, Alfonso F, Kastrati A. Drug-coated balloon therapy in coronary and peripheral artery disease. Nat Rev Cardiol. 2014;11:13–23.
Eiseman JL, Eddington ND, Leslie J, et al. Plasma pharmacokinetics and tissue distribution of paclitaxel in CD2F1 mice. Cancer Chemother Pharmacol. 1994;34:465–71.
Margolis J, McDonald J, Heuser R, et al. Systemic nanoparticle paclitaxel (nab-Paclitaxel) for in-stent restenosis I (SNAPIST-I): a first-in-human safety and dose-finding study. Clin Cardiol. 2007;30:165–70.
Freyhardt P, Zeller T, Kroncke TJ, et al. Plasma levels following application of paclitaxel-coated balloon catheters in patients with stenotic or occluded femoropopliteal arteries. Rofo. 2011;183:448–55.
Pasterkamp G, Wensing PJ, Post MJ, et al. Paradoxical arterial wall shrinkage may contribute to luminal narrowing of human atherosclerotic femoral arteries. Circulation. 1995;91:1444–9.
Acknowledgments
Open access funding provided by Medical University of Vienna. The pharmacokinetic study was sponsored by Eurocor GmbH. The vascular physiology measurements and histological analyses were supported by the Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Dr. Pogge von Strandmann and Dr. Stahnke are employees of Eurocor GmbH, Germany. The other authors have no conflict of interest.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Pavo, N., Samaha, E., Sabdyusheva, I. et al. Coating of intravascular balloon with paclitaxel prevents constrictive remodeling of the dilated porcine femoral artery due to inhibition of intimal and media fibrosis. J Mater Sci: Mater Med 27, 131 (2016). https://doi.org/10.1007/s10856-016-5737-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10856-016-5737-y