Abstract
Purpose
Quality of care in total knee arthroplasty (TKA) between implants was assessed using a novel composite outcome measure, early optimal recovery (EOR), to indicate ideal clinical outcomes and minimal healthcare resource utilization.
Methods
Patients that underwent primary TKA in the study group (ATTUNE® Knee System) or control group (LCS® COMPLETE Knee System) were included in this retrospective, single-center study. EOR was defined as no complications, no readmissions, no extra outpatient visits, ≤ 48 h length of hospital stay (LOS), and restored range of motion and pain perception at 3-month follow-up. Multivariate logistic regression was used to compare EOR between the study and control groups. Results were adjusted for differences in baseline characteristics and are presented with 95% confidence intervals (CI). Data were collected from a specialized clinic for elective surgeries in the Netherlands, between January 2017 and December 2020.
Results
A total of 566 patients (62.4% female, mean age 67 years) were included for analysis; 185 patients (32.7%) underwent TKA in the study group. Compared to the control group, patients in the study group had greater probability of achieving EOR (65.8% [95% CI: 55.1–75.2] vs. 38.9% [95% CI: 32.8–45.3]; p < 0.001), a LOS ≤ 48 h (77.2% [95% CI: 67.7–84.5] vs. 61.4% [95% CI: 54.7–67.7]; p < 0.05), and ideal pain perception at 3-month follow-up (93.3% [95% CI: 85.7–97.0] vs. 78.2% [95% CI: 71.0–83.9]; p < 0.05).
Conclusion
The study group was associated with a greater probability of achieving EOR versus the control group, suggesting improved quality of care.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Background
Total knee arthroplasty (TKA) is a widespread surgery, capable of recovering articular function and relieving pain in patients with osteoarthritis [1]. Incidence of TKA has been rising steadily over time, from just over 7000 surgeries performed in the Netherlands in 2007 to more than 25,000 performed in 2019 [2]. As more than 97% of TKA are performed on patients aged > 50 years, increasing life expectancy coupled with population growth in the Netherlands is expected to further increase the incidence of TKA over time [2, 3].
Key performance metrics in TKA frequently include number of postoperative complications, functional outcomes such as range of motion (ROM), and patient-reported pain and satisfaction using scores such as the Oxford knee score (OKS) and knee society score (KSS) [1, 4]. While TKA is associated with positive outcomes, approximately 20% of patients report dissatisfaction regarding pain and functionality following the procedure [4,5,6]. Additionally, health resource utilization (HRU) in TKA is high, particularly with respect to length of stay (LOS) and operating time [7]. Thus, as the incidence of TKA rises, so does the clinical and HRU burden associated with suboptimal procedures, and the need for quality improvements grows.
Value-based healthcare is a patient-centric model in which the quality of healthcare is measured according to the health outcomes achieved per unit cost [8]. In this model, metrics which provide a comprehensive, accurate reflection of patient satisfaction and quality of life are crucial; however, the complexity of healthcare makes accurate assessment difficult. Evaluation of TKA procedures using specific, individual metrics may fail to capture the extent of the procedure and can lead to significant variability in outcome reporting among studies [9]. All-or-none metrics are binary composite outcomes where overall success requires that a predefined ideal condition is met in each contributing element. By capturing the full complexity of procedures and ensuring that a successful procedure reflects satisfactory outcomes across all aspects of care, these metrics aim to raise the standard of patient-centricity in healthcare [10]. All-or-none metrics have found success in other surgical areas such as gastrointestinal and cardiovascular surgery, but have been studied less in orthopedic surgery [11,12,13]. In this study, the impact of implant design on quality of care in TKA was investigated using a novel, composite, all-or-none metric, early optimal recovery (EOR). The primary objective of TKA is to reduce pain and improve knee functionality [1, 14, 15]. Thus, EOR was designed to capture patient-reported pain, functionality measures, short-term complications, readmissions, prolonged LOS (> 48 h), and additional outpatient visits.
In this study, the ATTUNE® Knee System (study group) was compared against the LCS® COMPLETE Knee System (control group). The implant of the study group was developed to improve joint kinematics, reduce pain, increase stability, and address implant fit, and has previously demonstrated favorable postoperative clinical outcomes [4, 16,17,18,19,20,21,22,23], as well as decreased HRU burden in the form of reductions in LOS, number of outpatient visits, and complication rate compared to patients treated with other implants [17, 24,25,26,27,28].
Objectives
The objective of this study is to evaluate the overall quality of care achieved in the study group compared to the control group using a novel, composite, all-or-none metric called EOR. The study aims to determine if there is a significant difference in EOR between the two TKA implants, hypothesizing that the study group will show superior results over the control group.
Materials and methods
Study design
This retrospective study used EOR to evaluate two knee implants, the ATTUNE® Knee System (study group) and the LCS® COMPLETE Knee System (control group), at the Orthopedic Center, Bergman Clinics, Rijswijk, The Netherlands. Both implant designs were manufactured by DePuy Synthes, Warsaw, IN. The institutional review board of Bergman Clinics approved this study (BMC2020-008) and the Medical Ethics Committee of Nieuwegein deemed the study not subject to the Dutch Medical Research Involving Human Subjects Act (WMO) (W21.194). Data were extracted from patients’ medical records and anonymized by the physician (surgery date, patient name, and patient ID were deleted and variables were dichotomized when possible). Due to the anonymization strategy and as per general data protection regulation (GDPR), patients’ informed consent was not required.
All procedures were performed by three experienced orthopedic surgeons, each of whom performed more than 60 previous TKA procedures. The surgeries were performed in the Bergman Clinics, a large private clinic organization with more than 70 clinics in the Netherlands. TKA procedures were done in 5 separate clinic locations. One surgeon’s experience was primarily with the study device, one the control device, and one frequently implanted both devices. The study device was introduced in February 2019; prior to this, all surgeons utilized the control device.
Participants
Patients aged ≥ 18 years, with a body mass index (BMI) < 35 kg/m2 and an American Society of Anesthesiologists (ASA) score < III that underwent a unilateral primary TKA between January 2017 and December 2020 were included in this study. Exclusion criteria were contralateral TKA, infection or fracture of the ipsilateral knee < 1 year before TKA surgery, previous surgery within the same surgical area < 90 days before TKA surgery or contralateral TKA < 3 months after the index TKA. Uncemented TKA procedures, and procedures in which osteosynthesis material was removed, or in which a patella button or tibial sleeve component was used, were excluded. The implant used was determined by availability and surgeon preference and not influenced by patient characteristics.
Knee implant systems
For a schematic illustration of both prosthetic systems, please refer to Fig. 1 of Koster et al. [29]. Both knee implant systems utilize biocompatible materials such as cobalt-chromium alloys and ultrahigh molecular weight polyethylene for durability and reduced wear. Both aim to restore knee function, alleviate pain, and improve the overall quality of life for patients [29]. They focus on providing stability, range of motion, and longevity of the implant. In the current study, all surgeons used devices with a rotating platform, which were cemented, and cruciate-stabilized.
Control
The LCS® COMPLETE Knee system is known for its mobile-bearing design, allowing rotation and translation that mimic natural knee movements [30]. This system focuses on providing high conformity and reducing wear by allowing for self-alignment [30].
Study
The ATTUNE® Knee system emphasizes kinematic functionality and patient-specific biomechanics. It is designed to enhance knee stability in mid-flexion by featuring a continuously changing radius of femoral component curvature. This articulation surface geometry aims to encourage gradual femoral rollback, thereby reducing surface stresses [4, 16,17,18,19,20,21,22,23]. The bone-implant interface of the femoral component has fewer ridges compared to the control devices, providing a larger contact area. The study device also has more and smaller sizing increments available [29].
Surgical procedure
After administering either spinal or general anesthesia and prophylactic antibiotics, a tourniquet was placed around the upper leg of the patient. The standard medial parapatellar approach was used to access the joint. After measuring the extramedullary tibial alignment and performing a proximal tibial osteotomy, an intramedullary rod was placed to determine the femoral alignment and femoral osteotomy was performed. In case of asymmetry, osteophytes were removed and/or the varus-valgus angle was adjusted and/or medial/lateral collateral ligament release was performed. When flexion and extension gaps corresponded, final osteotomies were performed, and the knee implant component was cemented.
All patients received identical healthcare, and except from a change in anesthesia method, they had identical recovery programs throughout the period of observation. The anesthesia method was changed in September 2019 from a femoral block with a low dose of local infiltration anesthesia (LIA) to a saphenous block and a high dose of LIA.
All patients were admitted on the day of surgery. Patients were mobilized by a physiotherapist when the effect of anesthesia had worn off. Patients were discharged when (1) they were able to walk independently with crutches, (2) their pain was under control with oral medications, and (3) they had no wound complications. The standard pain protocol included paracetamol, nonsteroidal anti-inflammatory drugs, tramadol, and gabapentin.
Outcomes
Patient demographical characteristics included age, sex, BMI, smoking status, and ASA classification. Clinical characteristics included comorbidities (rheumatic diseases, cardiac disorder or coronary heart disease, hypertension, chronic obstructive pulmonary disorder, history of cerebrovascular accident, and diabetes mellitus) as well as previous surgeries in the operated knee.
The primary outcome measurement was the proportion of patients achieving EOR following TKA. EOR was assessed at 3-month follow-up and defined as no negative outcome measures (< 48 h LOS following initial surgery, no outpatient visits other than the 2 regular follow-up visits, no surgery-related readmissions, and no surgery-related complications), ideal ROM (complete extension [0 degrees] and complete flexion [≥ 120°] or flexion/extension greater or similar to the preoperative flexion/extension [31]), and ideal pain perception (a negative answer to the question: “do you still feel pain in the operated knee?” [14]). Complications included bleeding, wound nonhealing (such as dehiscence or necrosis), wound infection, deep joint infection, thromboembolic event, neurovascular injury, joint instability, ligament injury, malalignment, fracture, tibiofemoral or patellofemoral dislocation, implant loosening, implant fracture/tibial insert dissociation, bearing surface wear, osteolysis, reoperation, revision, or death. Baseline characteristics were adjusted for covariates (BMI, ASA classification, previous surgery, surgeon, and anesthesia methods) to account for differences between groups.
Secondary, individual outcome measurements were compared between the two groups including: ROM, pain perception, complication rate and type, total number of outpatient visits, ≤ 48 h LOS.
Sample size
We anticipated an EOR percentage of 75–80% in the study group and 60% in the control group. With an alpha of 5%, a power of 90%, and a two-sided Z-test, with ratio 1:2, the sample size calculation indicated approximately 170 in the study group and 433 in the control group.
Statistical methods
Outcome measures were analyzed descriptively. Values are reported with standard deviations (SDs) or 95% confidence intervals (CI). Bivariate comparison of baseline data was conducted.
Multivariate models were used to examine the outcomes between the study group and control group and were adjusted for the relevant demographic, patient, and procedural characteristics, including anesthesia method. Logistic regression models were used for categorical outcomes. Generalized linear modeling was used for length of stay with gamma distribution and log link. Confounders were included either on the basis of an absolute standardized difference of > 0.10 between the two groups, or by expectations from the literature. There was a check for multicollinearity.
All analyses were conducted using R Studio (2021.09.0 Build 351). Statistical significance was set at p < 0.05.
Results
Participants
A total of 566 patients were included in this study, of which 185 (32.7%) patients were included in the study group. See Fig. 1 for the inclusion flowchart.
The overall mean (SD) age of the cohort was 67 (8) years and 62.4% of the patients were female. All other baseline patient characteristics are found in Table 1. Most baseline characteristics were similar between the study and control groups. However, significant differences were observed in ASA II status (72.4% vs. 25.7%; p < 0.001), Charnley score A (38.4% vs. 20.5%; p < 0.001), and previous knee surgeries (32.4% vs. 8.1%; p < 0.001) (Table 1).
Procedural characteristics
The study device was only used in TKA performed in 2019 and 2020, while the number of TKA with the control device decreased over time. Surgeon 1 performed relatively fewer operations in the study group than the control group (32.4% vs. 83.7%; p < 0.001) (Table 2). Due to a change in anesthesia method, the femoral block + LIA was used less often in the study group than in the control group (48.6% vs. 96.9%; p < 0.001).
Surgeon 3 only performed TKA in 2019 and 2020, and performed a greater proportion of surgeries on ASA II patients compared to surgeons 1 and 2. Surgeon 3 also operated on more patients with previous ipsilateral knee surgery (p < 0.001), and had more participants in the study group (p < 0.001) than surgeons 1 and 2.
There were moderate to high correlations for the following variables: implant design, surgery year, anesthesia method, surgeon, ASA classification, and previous surgery. Due to the differences in baseline values, results were adjusted for covariates (BMI, ASA classification, previous surgery, surgeon, and anesthesia methods) unless specified otherwise. Operating year could not be integrated due to multicollinearity.
Primary outcome: EOR
After adjusting for covariates, patients in the study group had a significantly greater probability of achieving EOR (65.8% [95% CI: 55.1–75.2]) compared to patients in the control group (38.9% [95% CI: 32.8–45.3]; odds ratio: 0.33; p < 0.001, Table 3, Fig. 2). Unadjusted results of EOR are presented in Supplementary Table S1.
Secondary outcomes
Each individual outcome contributing to EOR was adjusted for covariates and compared between groups (Table 3). A significantly larger proportion of patients had a < 48 h LOS in the study group and were pain-free at 3 months in the study group compared to the control group. Differences in complication rates, readmission rates, number of outpatient visits, number of patients with ≤ 2 outpatient visits, and number of patients achieving ideal ROM were not significant between groups (Table 3). Complications observed in this study are presented in Table 4, and unadjusted study outcomes are presented in Supplementary Table S1.
Other analyses
Following the primary analysis, several subgroup analyses were also conducted: (1) only including years 2019–2020, as these years included both implants while in 2017–2018 only the control device was used, and because a decreasing trend in LOS was observed throughout, (2) excluding saphenous block + LIA as this was mostly used in 2020, mainly by surgeon 3 and mostly alongside the study device, (3) excluding surgeon 3 who operated mostly with the study device, (4) only including year 2019 with the same justification as (1) and because in 2019 there was an equal distribution of procedures between the control and study devices, and (5) excluding surgeons 2 and 3, and saphenous block + LIA with the same justification as (2) and (3), and because surgeon 1 did not use saphenous block + LIA except in one case. In each of the subgroup analyses, patients in the study group were significantly more likely to achieve EOR than those in the control group (all p < 0.05, Table 5).
Discussion
All results were adjusted for covariates including BMI, ASA classification, previous surgery, surgeon, and anesthesia method. The percentage of patients who achieved EOR was significantly higher in the study group (65.8% [95% CI: 55.1–75.2]) than in the control group (38.9% [95% CI: 32.8–45.3]; odds ratio: 0.33; p < 0.001). Compared to the control group, patients in the study group also had significant improvements in pain perception (pain-free rate control 78.2% vs. study 93.3%) at 3-month follow-up, and a significantly higher number of patients were discharged from hospital within 48 h after the procedure (LOS ≤ 48 h control 61.4% vs. study 77.2%). Differences between groups in postoperative ROM, complication rates, number of reoperations, and number of patients requiring readmission were not significant.
As a retrospective study, the lack of randomization and the opportunity for bias in measuring outcomes after exposure are inherent limitations of this study. The study reflects the experience of a single-center, and thus the replicability of these results is uncertain. Nevertheless, while we identified difference in baseline characteristics, they were controlled for using multivariate analysis methods. Robustness of the results was also investigated further in subgroup analyses. Additionally, the noticeably greater proportion of control devices compared to study devices, and the small sample size of patients with complications, readmissions, and reoperations place limitations on the conclusions which can be drawn. Due to the retrospective design, it was not possible to include robust measures of patient satisfaction or ambulatory status; future prospective studies may seek to address this.
Composite metrics in orthopedic surgery have found success in two studies where the quality of care was compared between hospitals; the composite metrics were superior to individual outcomes in highlighting variation between centers, and differences were detected faster and required less data, potentially decreasing the time required to introduce procedural innovations [32, 33]. To our knowledge, EOR is the first all-or-none composite outcome that attempts to demonstrate the quality of care associated with two TKA implant devices.
EOR was developed to evaluate the quality of care in TKA by combining functional outcomes (ideal ROM) and indicators of HRU burden (< 48 h LOS, no readmissions, and no reoperations) with measures of patient satisfaction (ideal pain perception). Therefore, EOR provides a simple, comprehensive image of the value of healthcare interventions in TKA and can be used to drive improvement initiatives such as the use of new devices, surgical techniques, or care programs. Additionally, metrics such as EOR could be used to compare performance between surgeons, facilities, or countries, as well as helping patients to make informed decisions about their healthcare.
The hypothesis that there would be a higher EOR in the study group compared to the control group was confirmed in this study. This aligns with previous findings which compared PROMs between the two devices where the study device (although underpowered) showed better three-month postoperative scores in KOOS-PS, OKS, and NRS activity compared to the control device [29]. The other clinical outcomes of Koster et al. [29] however were similar for the two designs and comparable to those reported in the Dutch registry for all patients undergoing TKA [2]. Although the EOR is not completely comparable to the outcomes measured in the study of Koster et al. [29], it does show a higher percentage of patients who are pain-free at 3 months post-surgery in the study group (98.8%) compared to the control group (78.2%; P < 0.02). In addition, it shows the advantages on HRU (higher percentages of LOS rate within 48 h for the study group (77.2%) compared to the control group (61.4%; P < 0.02). This difference in LOS between the study and control device was also seen in a study of Meermans et al. (2020) where patients who received the study device had a significantly shorter LOS (adjusted mean 2.76 days) versus the control group (adjusted mean 3.43 days; P < 0.01) [24]. In this case, it seemed like the design to enhance knee stability in mid-flexion by featuring a continuously changing radius of femoral component curvature helped with increasing the combined outcome EOR. These results align with previous research, where innovations in joint kinematics, implant fit, and stability associated with the study device have demonstrated improvements in pain perception, [4, 18, 34] and led to reductions in hospital LOS compared to patients treated with other implants, [24,25,26,27,28] addressing ongoing challenges in TKA.
The definition of optimal recovery is complex, and subjectivity in measures of patient satisfaction may reduce the alignment of EOR to real-world patient experience [35,36,37,38]. Future work may seek to enhance the value of EOR through the inclusion of patient-reported outcome measures such as the visual analog scale and KSS, which could increase the objectivity, applicability, and prognostic accuracy of EOR as an indicator of procedural success [39, 40]. Consensus studies could be used to reach agreement on patient treatment goals, [41] and align EOR with expert opinion on ideal quality of care [42]. Outcomes may be weighted to reflect their impact on patient satisfaction, for example, placing greater emphasis on a reoperation over a LOS > 48 h, and metrics more reflective of real-world outcomes, for example, indicators of joint functionality which better reflect postoperative ambulatory status and patient satisfaction [43].
EOR successfully measured the quality of care associated with TKA procedures and may have value in a value-based healthcare setting. EOR could be used to drive improvement initiatives, standardize measurement, and compare cross-center performance; however, further prospective studies are needed. Participants in the study group had a greater probability of achieving EOR in comparison to the control group, indicating that the implant leads to improved quality of care.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request. More details on Johnson & Johnson’s commitment to transparency are available via the following link: https://www.jnj.com/covid-19/our-commitment-to-transparency.
References
Escobar A, Quintana JM, Bilbao A, Azkárate J, Güenaga JI, Arenaza JC, Gutierrez LF (2006) Effect of patient characteristics on reported outcomes after total knee replacement. Rheumatology 46(1):112–119. https://doi.org/10.1093/rheumatology/kel184
Dutch Athroplasty Register (LROI). Annual report (2021). Available at: https://www.lroi-report.nl/app/uploads/2022/2002/PDF-LROI-annual-report-2021.pdf. http://www.lroi-report.nl
StatLine. Population, households and population dynamics (2021). Available at: https://opendata.cbs.nl/#/CBS/en/dataset/37556eng/table?ts=1663667216977
Indelli PF, Pipino G, Johnson P, Graceffa A, Marcucci M (2016) Posterior-stabilized total knee arthroplasty: a matched pair analysis of a classic and its evolutional design. Arthroplast Today 2(4):193–198. https://doi.org/10.1016/j.artd.2016.05.002
Bourne RB, Chesworth B, Davis A, Mahomed N, Charron K (2010) Comparing patient outcomes after THA and TKA: is there a difference? Clin Orthop Relat Res 468(2):542–546. https://doi.org/10.1007/s11999-009-1046-9
Tolk JJ, van der Steen MC, Janssen RPA, Reijman M (2017) Total knee arthroplasty: what to expect? a survey of the members of the Dutch knee society on long-term recovery after total knee arthroplasty. J Knee Surg 30(6):612–616. https://doi.org/10.1055/s-0036-1593868
Monsef JB, Della Valle AG, Mayman DJ, Marx RG, Ranawat AS, Boettner F (2014) The impact of blood management on length of stay after primary total knee arthroplasty. Open Orthop J 8:108–113. https://doi.org/10.2174/1874325001408010108
Porter ME (2010) What is value in health care? N Engl J Med 363(26):2477–2481. https://doi.org/10.1056/NEJMp1011024
Vajapey SP, Morris J, Spitzer AI, Glassman AH, Greco NJ, Li M (2020) Outcome reporting patterns in total knee arthroplasty: a systematic review. J Clin Orthop Trauma 11:S464–S471. https://doi.org/10.1016/j.jcot.2020.05.014
Nolan TW, Berwick DM (2006) All-or-none measurement raises the bar on performance. JAMA 295(10):1168–1170
Karthaus EG, Lijftogt N, Busweiler LAD, Elsman BHP, Wouters M, Vahl AC, Hamming JF (2017) textbook outcome: a composite measure for quality of elective aneurysm surgery. Ann Surg 266(5):898–904. https://doi.org/10.1097/sla.0000000000002388
Kolfschoten NE, Kievit J, Gooiker GA, van Leersum NJ, Snijders HS, Eddes EH, Tollenaar RA, Wouters MW, Marang-van de Mheen PJ (2013) Focusing on desired outcomes of care after colon cancer resections; hospital variations in ‘textbook outcome.’ Eur J Surg Oncol 39(2):156–163. https://doi.org/10.1016/j.ejso.2012.10.007
Busweiler LA, Schouwenburg MG, van Berge Henegouwen MI, Kolfschoten NE, de Jong PC, Rozema T, Wijnhoven BP, van Hillegersberg R, Wouters MW, van Sandick JW (2017) Textbook outcome as a composite measure in oesophagogastric cancer surgery. Br J Surg 104(6):742–750. https://doi.org/10.1002/bjs.10486
Puolakka PA, Rorarius MG, Roviola M, Puolakka TJ, Nordhausen K, Lindgren L (2010) Persistent pain following knee arthroplasty. Eur J Anaesthesiol EJA 27(5):455–460. https://doi.org/10.1097/EJA.0b013e328335b31c
Zanasi S (2011) Innovations in total knee replacement: new trends in operative treatment and changes in peri-operative management. Eur Orthop Traumatol 2(1–2):21–31. https://doi.org/10.1007/s12570-011-0066-6
Clary CW, Fitzpatrick CK, Maletsky LP, & Rulkoetter PJ (2012) Improving Dynamic Mid-stance Stability: An Experimental and Finite Element. Study Research Society. 58th Annual Meeting. San Francisco, CA, 1044
Toomey SD, Daccach JA, Shah JC, Himden SE, Lesko JP, Hamilton WG (2017) Comparative incidence of patellofemoral complications between 2 total knee arthroplasty systems in a multicenter. Prospective Clin Study J Arthroplast 32(9s):S187-s192. https://doi.org/10.1016/j.arth.2017.04.014
Martin JR, Jennings JM, Watters TS, Levy DL, McNabb DC, Dennis DA (2017) Femoral implant design modification decreases the incidence of patellar crepitus in total knee arthroplasty. J Arthroplast 32(4):1310–1313. https://doi.org/10.1016/j.arth.2016.11.025
Takagi H, Asai S, Sato A, Maekawa M, Kawashima H, Kanzaki K (2012) (2017) Case series report of navigation-based in vivo knee kinematics in total knee arthroplasty with a gradually reducing femoral radius design. Ann Med Surg 17:33–37. https://doi.org/10.1016/j.amsu.2017.03.032
Khasian M, Sharma A, Fehring TK, Griffin WL, Mason JB, Komistek RD (2020) Kinematic performance of gradually variable radius posterior-stabilized primary tka during various activities: an in vivo study using fluoroscopy. J Arthroplast 35(4):1101–1108. https://doi.org/10.1016/j.arth.2019.10.053
Pfitzner T, Moewis P, Stein P, Boeth H, Trepczynski A, Von Roth P, Duda GN (2018) Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation. Knee Surg Sports Traumatol Arthrosc 26(6):1645–1655. https://doi.org/10.1007/s00167-017-4622-7
List R, Schütz P, Angst M, Ellenberger L, Dätwyler K, Ferguson SJ (2020) Videofluoroscopic evaluation of the influence of a gradually reducing femoral radius on joint kinematics during daily activities in total knee arthroplasty. J Arthroplast 35(10):3010–3030. https://doi.org/10.1016/j.arth.2020.05.039
Ranawat CS, White PB, West S, Ranawat AS (2017) Clinical and Radiographic results of attune and PFC sigma knee designs at 2-year follow-up: a prospective matched-pair analysis. J Arthroplast 32(2):431–436. https://doi.org/10.1016/j.arth.2016.07.021
Meermans G, Galvain T, Wigham R, Do Rego B, Schröer D (2020) Comparative analysis investigating the impact of implant design on hospital length of stay and discharge destination in a Dutch hospital with an established enhanced recovery program. J Arthroplast 35(1):182–187. https://doi.org/10.1016/j.arth.2019.08.040
Etter K, Lerner J, Kalsekar I, de Moor C, Yoo A, Swank M (2018) Comparative analysis of hospital length of stay and discharge status of two contemporary primary total knee systems. J Knee Surg 31(6):541–550. https://doi.org/10.1055/s-0037-1604442
Brüggenjürgen B, Muehlendyck C, Gador LV, Katzer A (2019) Length of stay after introduction of a new total knee arthroplasty (TKA)-results of a German retrospective database analysis. Med Devices (Auckl) 12:245–251. https://doi.org/10.2147/mder.S191529
Mantel J, Corso KA, Wei D, Holy CE, Muehlendyck C, Jayakumar P, Higgins M, Westbrook A (2017) Economic effectiveness Of The Attune® Knee System - analysis of real world hospital length of stay and incidence of early complications. Value in Health 20(9):A579. https://doi.org/10.1016/j.jval.2017.08.1023
Pipino G, Paragò V, Corso KA, Wigham R, Holy C, Rego B (2017) Economic outcomes of The Attune® Knee System: analysis of real world length of stay in an Italian hospital. Value Health 20:A595. https://doi.org/10.1016/j.jval.2017.08.1116
Koster LA, Rassir R, Kaptein BL, Sierevelt IN, Schager M, Nelissen R, Nolte PA (2023) A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty. Bone Joint J 105-B(2):148–157. https://doi.org/10.1302/0301-620X.105B2.BJJ-2022-0414.R1
Zurcher A, van Hutten K, Harlaar J, Poll R (2017) Mobility of the rotating platform in low contact stress knee arthroplasty is durable. Knee Surg Sports Traumatol Arthrosc 25(8):2580–2585. https://doi.org/10.1007/s00167-015-3823-1
Zhou Z, Yew KS, Arul E, Chin PL, Tay KJ, Lo NN, Chia SL, Yeo SJ (2015) Recovery in knee range of motion reaches a plateau by 12 months after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23(6):1729–1733. https://doi.org/10.1007/s00167-014-3212-1
van Schie P, van Bodegom-Vos L, Van Steenbergen LN, Nelissen RGHH, Marang-van de Mheen PJ (2022) A more comprehensive evaluation of quality of care after total hip and knee arthroplasty: combining 4 indicators in an ordered composite outcome. Acta Orthop 93:138–145. https://doi.org/10.2340/17453674.2021.861
Hofstede SN, Ceyisakar IE, Lingsma HF, Kringos DS, Marang-van de Mheen PJ (2019) Ranking hospitals: do we gain reliability by using composite rather than individual indicators? BMJ Qual Saf 28(2):94–102. https://doi.org/10.1136/bmjqs-2017-007669
Richardson G, Turgeon T, T G, E L, E B, and M D (2017) Stability assessment of a new knee replacement product using radiostereometric analysis. Poster presentation at the Canadian orthopaedic association meeting, Ottawa, Ontario
Hamilton DF, Lane JV, Gaston P, Patton JT, Macdonald D, Simpson AH, Howie CR (2013) What determines patient satisfaction with surgery? a prospective cohort study of 4709 patients following total joint replacement. BMJ Open 3(4):e002525. https://doi.org/10.1136/bmjopen-2012-002525
Lingard EA, Sledge CB, Learmonth ID (2006) Patient expectations regarding total knee arthroplasty: differences among the United States, United Kingdom, and Australia. J Bone Joint Surg Am 88(6):1201–1207. https://doi.org/10.2106/jbjs.E.00147
Barrack R, Ruh E, Chen J, Lombardi A, Berend K, Parvizi J, Valle C, Hamilton W, Nunley R (2013) Impact of socioeconomic factors on outcome of total knee arthroplasty. Clin orthop relat res. https://doi.org/10.1007/s11999-013-3002-y
Scott CE, Oliver WM, MacDonald D, Wade FA, Moran M, Breusch SJ (2016) Predicting dissatisfaction following total knee arthroplasty in patients under 55 years of age. Bone Joint J 98-b(12):1625–1634. https://doi.org/10.1302/0301-620x.98b12.Bjj-2016-0375.R1
Giesinger JM, Hamilton DF, Jost B, Behrend H, Giesinger K (2015) WOMAC, EQ-5D and knee society score thresholds for treatment success after total knee arthroplasty. J Arthroplast 30(12):2154–2158. https://doi.org/10.1016/j.arth.2015.06.012
Andersen JD, Hangaard S, Buus AAØ, Laursen M, Hejlesen OK, El-Galaly A (2021) Development of a multivariable prediction model for early revision of total knee arthroplasty – the effect of including patient-reported outcome measures. J Orthop 24:216–221. https://doi.org/10.1016/j.jor.2021.03.001
Lange T, Schmitt J, Kopkow C, Rataj E, Günther K-P, Lützner J (2017) What do patients expect from total knee arthroplasty? a Delphi consensus study on patient treatment goals. J Arthroplast 32(7):2093-2099.e2091. https://doi.org/10.1016/j.arth.2017.01.053
Anderson AM, Comer C, Smith TO, Drew BT, Pandit H, Antcliff D, Redmond AC, McHugh GA (2021) Consensus on pre-operative total knee replacement education and prehabilitation recommendations: a UK-based modified Delphi study. BMC Musculoskelet Disord 22(1):352. https://doi.org/10.1186/s12891-021-04160-5
Farahini H, Moghtadaei M, Bagheri A, Akbarian E (2012) Factors influencing range of motion after total knee arthroplasty. Iran Red Crescent Med J 14(7):417–421
Acknowledgements
The authors acknowledge Reuben Duncan, Marc Lynch, PhD, and Alex Pashley, MChem, from Costello Medical, UK, for medical writing and editorial assistance based on the authors’ input and direction.
Funding
This study was sponsored by Johnson & Johnson. Support for third-party writing assistance for this article, provided by Costello Medical, UK, was funded by Johnson & Johnson in accordance with Good Publication Practice (GPP3) guidelines: https://www.ismpp.org/gpp3.
Author information
Authors and Affiliations
Contributions
All authors contributed to the design of the study protocol and writing of the manuscript. TG and PvK performed the data analysis. LvK wrote the first draft of the article and validated the data.
Corresponding author
Ethics declarations
Conflict of interest
LvK, RJAS, PvK, and TAJtK: nothing to disclose. TG, CM, SD and PB are employees of Johnson & Johnson. NRAB and TH are consultants for Johnson & Johnson.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
van Keulen, L.Z., Sonnega, R.J.A., Baas, N.R.A. et al. Evaluating two implant designs in patients undergoing primary total knee arthroplasty using a novel measure of early optimal recovery: a retrospective observational study. Musculoskelet Surg (2024). https://doi.org/10.1007/s12306-024-00851-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s12306-024-00851-z