Abstract
Background
This study sought to investigate the feasibility, safety and effectiveness of transcatheter closure of atrial septal defects (ASDs) under the guidance of transesophageal echocardiography (TEE) in children.
Methods
We reviewed the medical records of patients who underwent percutaneous ASD closure at our center from August 2016 to December 2017. For a total of 88 patients who were identified as having a single-hole defect and were undergoing percutaneous transcatheter ASD closure, a procedure completely guided by TEE was performed. There were 31 male patients and 57 female patients. The patients’ mean age was 60.09 ± 36.42 months (13–182 months), and their mean body weight was 20.16 ± 10.04 kg (9–77 kg). Patients were followed up by performing transthoracic echocardiography and obtaining chest X-rays and electrocardiograms.
Results
The transcatheter closure of ASDs was successful in all patients. The mean ASD size was 11.58 ± 5.31 mm (3–28 mm), and the mean size of the occlusion device was 16.07 ± 5.29 mm (6–36 mm). The mean procedural times were 13.33 ± 2.82 minutes (6–16 minutes). The mean hospitalization costs were 27,259.66 ± 2507.04 RMB (25,200.00–33,911.45 RMB). The mean postoperative hospital stay was 3.22 ± 0.53 days (3–5 days). Residual shunt, occlusion device shedding or displacement, and pericardial effusion were not observed during or after the operation.
Conclusion
Percutaneous transcatheter ASD closure completely guided by TEE is a feasible, safe, non-invasive and easy procedure.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Transcatheter closure is the preferred treatment for atrial septal defects (ASDs) when the anatomy is suitable because a lower rate of early postprocedural complications is observed for transcatheter closure than that for surgery [1]. Because the development of a safe and less invasive procedure with less radiation exposure is important, particularly for a procedure performed on children, and transesophageal echocardiography (TEE) was generally used patients with clear sound window, transcatheter ASD closure guided by TEE is proposed.
Initially, TEE was used to supplement X-ray imaging in catheter guidance and intraoperative evaluation of cardiac surgery. In recent years, TEE has been found to be feasible for guiding transcatheter ASD closure in children. We retrospectively reviewed cases in our hospital to evaluate the feasibility, safety and effectiveness of this approach.
Methods
This study was approved by the Ethics Committee of Children’s Hospital, Zhejiang University School of Medicine.
All patients were preoperatively diagnosed with isolated secundum ASD based on medical history, clinical signs, chest X-rays, electrocardiograms and transthoracic echocardiography (TTE). Careful examination was performed to assess the locations, numbers, sizes and morphology of ASDs; the distances of ASDs from the superior and inferior vena cava, the atrioventricular valve, and the atrial roof; and ASD dimensions. No patient had severe pulmonary hypertension or evidence of an infectious disease or other diseases that would be contraindications for surgery.
Procedure
After total intravenous and endotracheal anesthesia was induced, we revaluated each ASD via TEE (Philips IE-33) from various viewpoints. In general, we used the right femoral vein as the catheter path, and a 5F arterial sheath was introduced after the vein was punctured. We intravenously administered heparin at a dose of 100 units/kg prior to the procedure. The ASD occluder system from Shanghai Shape Memory Alloy Material Co. Ltd. or Lifetech Technology (Shenzhen) Co., Ltd. was selected.
We use dual imaging/color to visualize the probe in the whole procedure. We selected 90°–110° tomographic sections and inserted a 5F multipurpose (MP) catheter (measuring the distance between the puncture and the left intercostal space of the sternum). We made fine adjustments to show the inferior and superior vena cava and guide the catheter to pass through the inferior vena cava to the left atrium. The wire might sometimes mistakenly enter a liver or kidney vein, particularly during procedures performed by new operators. To avoid this problem, we typically measured the distance between the heart and the incision location and switched from an esophageal probe to an abdominal probe to track the wire. Once the end of this distance had been reached and we could not see the wire in the atrium, we could withdraw the wire immediately to ensure that the liver or kidney remained undamaged. An MP catheter was placed into the left pulmonary vein through the ASD using a TEE transducer angle of 45°–90°, and the catheter was guided into the left atrium or the left pulmonary vein. The catheter was fixed, and the probe was rotated to the left to enable observation of the left atrial appendage and left pulmonary vein and to the right to permit observation of the right pulmonary vein and confirm that the catheter did not reach the top of the left atrial appendage.
A 0.035″ guide wire was inserted into the delivery sheath, and the occlusion device was fed along the delivery sheath into the left atrium. We observed the top of the sheath, created a pathway to deliver the occlusion device, and retracted the wire and core; the occlusion device was then sent along this pathway to the ASD. We subsequently released the left atrial disc after the withdrawal of the delivery system to close the atrial septum and retracted the outer sheath to release the waist and right atrial disc of the occlusion device such that the atrial septum was between the left and right umbrella folders. We used color flow Doppler to confirm closure of the ASD, unobstructed systemic/pulmonary venous return, and no compromise of atrioventricular valve function. After the successful release of the occlusion device had been verified, the delivery system was removed, and the femoral vein puncture was covered with a pressure bandage.
During the procedure, we closely monitored electrocardiograms for conduction block, T wave changes, other arrhythmias, blood pressure changes, and additional unexpected observations; if any abnormalities were detected, the patient would have immediately been referred for surgical closure (Fig. 1).
Follow-up
Patients were followed up via TTE to assess cardiac function, occlusion device morphology, residual shunt status, and other indicators. Additionally, the patients’ chest X-rays and electrocardiograms were double-checked in cases involving complications.
Results
From August 2016 to December 2017, 88 patients with isolated ostium secundum ASD underwent ASD closure under the guidance of TEE. There were 31 male patients and 57 female patients. The patients’ mean age was 60.09 ± 36.42 months (13–182 months), and their mean body weight was 20.16 ± 10.04 kg (9–77 kg).
Percutaneous transcatheter closure of ASD under the guidance of TEE was performed successfully in all children. The sizes of the secundum ASDs ranged from 3 to 28 mm (11.58 ± 5.31 mm), and the mean distances from the rim to the atrial roof, the superior vena cava and the inferior vena cava were 10.68 ± 3.25 mm (4–19 mm), 13.29 ± 4.45 mm (3.6–25 mm) and 13.11 ± 4.51 mm (6–33 mm), respectively. The mean size of the occlusion device was 16.07 ± 5.29 mm (6–36 mm). The patients were examined via TEE immediately after procedure, and all findings were normal (Table 1). The mean procedural times were 13.33 ± 2.82 minutes (6–16 minutes).
No complications, such as displacement of occluder, cardiac arrhythmia, pericardial effusion, hemolysis were found during follow-up reviews conducted on the first postoperative day, The mean hospitalization costs was 4124.0 ± 379.2 USD (3812.4-5130.3 USD).The mean postoperative hospital stay was 3.2 ± 0.5 days (3–5 days). No complications were found during the third month and one-half year after the procedure.
Discussion
Minimally invasive procedure has become a preferable choice for ASD closure because such procedure does not require thoracotomy, does not leave a scar on the chest and involves less incisions [1,2,3,4].
TEE can provide detailed observations of an ASD and its rims and is a feasible, safe, non-invasive and easy procedure. Moreover, relative to the surgery, TEE results in shorter recovery times, shorter hospital stays, and fewer complications. The use of TEE has been shown to be safe and effective for guidance of ASD closures [2]. Transcatheter closure is evolving to become the new and efficient standard of care for children with ASD [5, 6].
In traditional ASD closure by catheterization, digital subtraction angiography (DSA) is used to estimate the patient’s preoperative condition and to postoperatively indicate whether an operation has been successful due to the clear visualization and immediacy; ultrasound is only used to assist with preoperative assessment [7]. However, DSA-emitted X-rays harm the health of patients and operators [8]. We have found that TEE feasibly provides guidance throughout the entire ASD closure procedure [9]. TEE does not emit radiation; this advantage is especially important for growing children [10,11,12]. Given that DSA instruments are expensive, resulting in procedures that cost much more than TEE-guided procedure, TEE is a better choice than DSA for ASD closure in children.
During ASD closure in children under the guidance of TEE alone, TEE is used to guide wire passage through the vena cava to the right atrium. When the wire enters the right atrium, TEE can reveal the location of the wire and can be helpful when guiding the wire across the ASD and creating a path for the occlusion device. TEE can be utilized to carefully monitor the entire process of the occlusion device being released, particularly with respect to ensuring that the device is correctly placed, determining whether the device is completely released, verifying that no residual shunt remains and indicating the condition of the atrial valve. In our procedures, when the occlusion device was confirmed to be correctly placed, we released the device completely to assess the effect of the device.
The entire minimally invasive process is performed completely under the guidance of TEE; as a result, the principal advantage is avoidance of ionizing radiation; meanwhile, no open chest surgery is performed, no scars are left on patients’ chests, and there is a relatively low risk of postoperative infections. Although TTE can also be used to guide the process, TTE cannot provide a picture as clear as that produced by TEE and can be highly inaccurate in overweight, barrel-chested patients [13,14,15]. Moreover, TTE requires operators with expertise [16].
We successfully occluded 88 patients. One 10-year-old patient with 3 mm ASD was performed the procedure because he suffered from repeated respiratory infections and also had a family history of stroke. After being fully informed about the situation, the parents of the patient asked us to perform the treatment. All patients were treated while under general anesthesia; given that a baby’s esophagus is delicate, we used a probe designed specifically for babies to avoid oropharyngeal and esophageal trauma [17]. All procedures were performed on operating tables to allow for immediate conversion to open chest surgery without the need to anesthetize patients again in case the procedure failed [14].
In conclusion, non-fluoroscopic percutaneous transcatheter ASD closure in children under the guidance of TEE not only avoids the use of DSA but also is easy to learn and utilize. This procedure offers a safe, feasible and effective method for ASD closure.
References
Butera G, Biondi-Zoccai G, Sangiorgi G, Abella R, Giamberti A, Bussadori C, et al. Percutaneous versus surgical closure of secundum atrial septal defects: a systematic review and meta-analysis of currently available clinical evidence. EuroIntervention. 2011;7:377–85.
Wu Q, Yang Y, Xu X, Gao L, Yang J, Wang X, et al. Echocardiography in mini-invasive surgical device closure of secundum atrial septal defects. Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2013;38:602–9 (in Chinese).
Carminati M, Giusti S, Hausdorf G, Qureshi S, Tynan M, Witsenburg M, et al. A European multicentric experience using the CardioSEal and Starflex double umbrella devices to close interatrial communications holes within the oval fossa. Cardiol Young. 2000;10:519–26.
Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K. Amplatzer Investigators. Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol. 2002;39:1836–44.
Yang Y, Zhang W, Wu Q, Gao L, Jin W, Zhao T. Transcatheter closure of atrial septal defects without fluoroscopy: a well-established procedure for alternative use in children. EuroIntervention. 2016;12:e652–7.
Gao W, Zhou AQ, Yu ZQ, Li F, Zhang YQ, Sun K, et al. Transcatheter closure of secundum atrial septal defect in children. Zhonghua Er Ke Za Zhi. 2004;42:287–90 (in Chinese).
Tseng HC, Hsiao PN, Lin YH, Wang JK, Tsai SK. Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect. J Formos Med Assoc. 2000;99:684–8.
Wagdi P, Ritter M. Patient radiation dose during percutaneous interventional closure of interatrial communications. J Cardiol. 2009;53:368–73.
Schulze CJ, Wildhirt SM, Boehm DH, Weigand C, Kornberg A, Reichenspurner H, et al. Continuous transesophageal echocardiographic (TEE) monitoring during port-access cardiac surgery. Heart Surg Forum. 1999;2:54–9.
Kleinerman RA. Cancer risks following diagnostic and therapeutic radiation exposure in children. Pediatr Radiol. 2006;36(Suppl 2):121–5.
Abrams HL, Bingham E, Buffler PA, Cardis E, Cleaver JE, Cox R. Health risks from exposure to low levels of ionizing radiation: BEIR VII-Phase 2. National Research Council; 2006.
Yakoumakis EN, Gialousis GI, Papadopoulou D, Makri T, Pappouli Z, Yakoumakis N, et al. Estimation of children’s radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation. J Radiol Prot. 2009;29:251–61.
Lu H, Chen L, Zhang G, Liao D, Wang Q. Clinical evaluation of percutaneous atrial septal defect closer guided by transthoracic echocardiography and/or transesophageal echocardiography. Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2015;40:646–50 (in Chinese).
Feng KJ, Wang H, Meng H, Zhao X, Ouyang WB, Zhang FW, et al. Transcatheter closure of atrial septal defect under the guidance of two-dimensional transthoracic echocardiography. Chin J Ultrasonogr. 2014;23:573–6 (in Chinese).
Pan X, Li S, Hu S, Ouyang W, Zhang F, Zhang D, et al. Feasibility of transcatheter closure of atrial septal defect under the guidance of transthoracic echocardiography. Zhonghua Xin Xue Guan Bing Za Zhi. 2014;42:744–7 (in Chinese).
Baruteau AE, Hascoet S, Fraisse A. Transthoracic echocardiography is a safe alternative for assessment and guidance of transcatheter closure of secundum atrial septal defect in children. J Thorac Dis. 2017;9:1247–56.
Hanslik A, Moysich A, Laser KT, Mlczoch E, Kececioglu D, Haas NA. Percutaneous closure of atrial septal defects in spontaneously breathing children under deep sedation: a feasible and safe concept. Pediatr Cardiol. 2014;35:215–22.
Funding
This study was funded by a Grant from the Department of Education of Zhejiang Province (Y201636526).
Author information
Authors and Affiliations
Contributions
JJY and WZX conceived and designed the project, analyzed the data, and drafted the initial manuscript. JHL, JGY and ZWZ collected the data and participated in patient management. JY and XYS interpreted the data and funded the project. All authors approved the final manuscript as submitted.
Corresponding author
Ethics declarations
Ethical approval
All procedures performed in studies involving human participants were conducted in accordance with the ethical standards of applicable institutional and/or national research committees and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Conflict of interest
All authors declare that there are no conflicts of interest associated with this work.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Xu, WZ., Shou, XY., Li, JH. et al. Non-fluoroscopic percutaneous transcatheter closure of atrial septal defects in children under transesophageal echocardiographic guidance. World J Pediatr 14, 378–382 (2018). https://doi.org/10.1007/s12519-018-0179-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12519-018-0179-x