Abstract
Mass–energy transfer across the boundaries of living systems is crucial for the maintenance of homeostasis; however, it is scarcely known how structural strength and integrity is maintained in extended phenotypes while also achieving optimum heat–mass exchange. Here we present data on strength, stability, porosity and permeability of termite mounds of a fungus-farming species, Odontotermes obesus. We demonstrate that the termite mound is a bi-layered structure with a dense, strong core and a porous shell that is constantly remodelled. Its safety factor is extraordinarily high and is orders of magnitude higher than those of human constructions. The porous peripheries are analogous to the mulch layer used in agriculture and help in moisture retention crucial for the survival of fungus gardens, while also allowing adequate wind-induced ventilation of the mounds. We suggest that the architectural solutions offered by these termites have wider implications for natural and industrial building technologies.
Similar content being viewed by others
Introduction
Mass–energy transfer across the boundaries of living systems is crucial for the maintenance of homeostasis1. These boundaries can be that of an individual (human skin)2 or a colony of individuals (swarm cluster of honeybees)3 or that of a constructed extended phenotype (termite mounds)4,5. The boundary conditions in these systems determine the mass and energy fluxes; therefore, the boundary must be able to respond to ambient changes. Homeostasis can be achieved, for example, by regulation of blood flow to skin2, or the movement of individuals between the periphery and core of a honeybee swarm3; however, little is known about this transfer when the boundary consists of non-living materials, e.g. soil, as in the walls of termite mounds. Regulation becomes more challenging when the construction crew is subterranean as in fungus-farming termites with their fungus gardens6,7,8. Moreover, while the external boundaries of these earthen structures must primarily be designed to respond to changes in the external environment, the internal regions need to maintain structural strength in order to prevent collapse.
Termite mounds are excellent examples of biocementation and collective construction9. Mounds can be three orders of magnitude larger than individual termites9 and can maintain structural integrity for decades to centuries10. Termites collect small, irregular spheres of soil, which they use for construction9. These are analogous to bricks used in human construction, are termed ‘boluses’ (singular: bolus), and are made by mixing their secretions with moist soil11. Once deposited at the construction site, boluses merge and form an almost monolithic structure resembling construction using amorphous materials such as foam. This material nature allows mound construction on irregular surfaces9. Soil manipulation by termites imparts a ten-fold increase to its strength11. Compressive strength and density of mound soil increases from the top to the bottom of the mound due to compaction under self-weight over time11. Termite mounds harness diurnal temperature oscillations for ventilation with convection currents reversing directions across days and nights4. The buttresses of these cathedral-like (terminology taken from Korb and Linsenmair12 mounds (also referred to as flutes)) have surface conduits which are involved in gaseous exchange with the surroundings (see Supplementary Fig. S1 online)4,9. Moreover, mounds also maintain elevated relative humidity (> 98%), extremely high CO2 concentrations (< 1–6%)4,13, and dampened temperature variations relative to the external environment12. This is crucial for the survival of the fungus garden that termites cultivate for food6. Therefore, it is important for the termite mound to have highly regulated exchange of gases through its walls.
Gaseous exchange through the mound walls requires them to be porous14, but it is not clear how this is achieved simultaneously with high strength which requires greater density of soil. While the density of cathedral-shaped termite mounds and concomitantly soil strength increased from the top to the bottom11, very few measurements have been made on the actual structure of mounds. Circumdiel reversal of air flow directions within the peripheries of termite mounds suggests their importance in gaseous exchange4. An interesting trade-off therefore has to be achieved between sufficient ventilation and high strength and stability. In this series of experiments, we explore how high strength and stability coupled with adequate porosity are achieved in mound structure. We tested the strength of the soil, porosity and air permeability of the periphery and core of termite mounds. We further examined the implications of mound geometry in terms of the slope stability and safety factors for a termite mound (see “Methods” for details).
Results
Strength of termite mound regions
Strength testing was conducted on small cylindrical samples extracted from the core and peripheral buttresses of mounds. Samples from abandoned and occupied mounds were used to examine any differences arising from constant repair and remodelling by termites in the occupied mounds. An abandoned mound was sectioned into slices and samples were extracted from each slice (see Supplementary Fig. S1 online). Occupied mounds were drilled into to obtain samples while minimising damage (see “Methods” for details). For the abandoned mound, core and buttress regions differed significantly in peak compressive stress along the cross sections (results of type II analysis of variance (ANOVA): Compressive strength ~ Height + Region; Height: F5,70 = 1.01, P = 0.41; Region: F1,70 = 6.96; P = 0.01; Fig. 1a; see “Methods” for details) with the core being up to 35–40% stronger than the buttress. A similar pattern was observed for occupied mounds for heights of 90 cm and 120 cm from the base wherein higher strength was recorded for the core compared to the buttress at 90 cm and 120 cm from the base; however, the difference was statistically significant only at 120 cm from the base (unpaired t test for samples extracted at 90 cm from base: t = − 2.18, P = 0.057; unpaired t test for samples extracted at 120 cm from base: t = − 2.20, P = 0.04; Fig. 1b; see “Methods” for details). The difference in compressive strength between core and buttress was not statistically significant at 90 cm from the base of the mound probably owing to consolidation via material settlement over time at the base of the mound (Fig. 1b). Furthermore, termites engage in lesser remodelling of the buttress at lower heights (most mound remodelling takes place at the top of the mound (N Zachariah, pers. observ.)), thereby allowing for consolidation over time at the base. It is evident, therefore, that the termite mound is a bi-layered structure with the core stronger than the buttress.
Stability analysis of termite mounds
Since termite mounds are made up of soil particles adhered together and do not undergo slope movement due to gravity, it is important to quantify the resistance of termite mounds towards slope movement. Slope stability analysis assesses the resistance/vulnerability of slopes or rocks towards movement. We performed slope stability analysis to evaluate the mechanical stability of the mound against gravity, i.e. under self-weight. A prerequisite for slope stability analysis is measuring variation in density, compressive strength and tensile strength of the material across topology. Tensile strength of the termite mound represents the cohesion between soil particles and matrix suction due to partial saturation of pores as well as biocementation11 (see “Methods”). Average tensile strength (see “Methods”) did not change along the height and region (buttress versus core) of the mound (results of type II analysis of variance (ANOVA): Tensile strength ~ Height + Region; Height: F2,11 = 1.29, P = 0.31; Region: F1,11 = 0.27; P = 0.61; Fig. 2; see “Methods” for details) suggesting that the cohesion achieved between soil particles in mound construction is the same throughout.
For slope stability analysis, we modelled the geometry of the mound as both a triangle and a trapezoid (see “Methods”). These two geometries represent two extreme cases while the reality of the fluted, cathedral-like mounds probably lies somewhere in between. A triangular geometric domain was much more stable than a trapezoidal domain with safety factors of 113 and 46 respectively keeping the base soil as infinitely rigid (Fig. 3) and using parameters characteristic of occupied mounds. The intact domain after failure was identical for both cases (Fig. 3). The strength of the base soil places a practical limitation on the dimension of the termite mound. If the base soil is considered as purely frictional (not rigid as assumed before) with friction angle of 27° (according to measurements reported in Kandasami et al.11 for this residual soil) the maximum height of the triangular mound would be approximately 15 m for a mechanically safe structure. Since termite mounds of this species do not reach such heights in nature, additional constraints must be in operation. Similar analysis was carried out for material parameters extracted for an abandoned mound. Here the safety factor for triangular and trapezoidal geometries were 147 and 60 respectively, indicating small increases in these values over the occupied mounds. It is possible that with the presence of moisture in occupied mounds, the compressive strength is lower, though still very high.
Porosity distribution from computed tomography
Given that termite mounds are highly stable structures, we further investigated the porosity and permeability of mound walls that facilitate gaseous homeostasis. We examined the distribution of the pore structure in the mound core and buttress through a series of X-ray computed tomography analyses (see “Methods”). The average pore size in the mounds was 0.53 ± 0.09 mm (mean ± SD). Overall, larger pore sizes were found in the buttress when compared to the core in the top and middle sections of the mound (Fig. 4; Table 1). This is also apparent from the results of compressive strength testing where the buttress was weaker in compression compared to the core in the top and middle regions of the mound compared to the base.
Air permeability of mound soil
To understand the functional significance of this difference in porosity between core and periphery, air permeability was tested in samples from the core and buttress of abandoned and occupied mounds (see “Methods”). Higher pressure was necessary to achieve the same flow velocity for the core samples indicating that the core had lower permeability than the buttress (Fig. 5). Sample permeability is expected to depend on the number, size, distribution and connection of pores within the sample. The pore size was smaller for the core in all cases except for one (Table 1), and consequently the permeability was always lower for the core than the buttress. In addition to the difference in strength, porosity and permeability, the thickness of mound walls is highest at the centre (~ 5–15 cm) and is lowest in the buttress (~ 2 cm) (see Supplementary Fig. S1 online). Moreover, the buttress walls have pits (Fig. S1) which further reduce the effective barrier between the mound interior and exterior to only ~ 5 mm.
Discussion
All our results, combined together, indicate that termites construct bi-layered mounds with a strong core and a porous periphery; this combination achieves the dual function of extraordinary strength, stability as well as ventilation. Our results suggest that termite mounds are of an intermediate geometry between a triangle and a trapezoid with extraordinarily high safety factors. Most human construction is designed with a factor of safety between 1 and 2 except for potentially hazardous structures such as dams and nuclear power plants15. It is, however, noteworthy that our analysis considers only the effect of gravity; other natural disturbances arising from the surroundings might require higher safety factors or can reduce the maximum height termite mounds can attain—one possible reason why 15 m tall termite mounds are not seen in nature. Even after considering natural disturbances, we expect that the factor of safety for termite mounds will be much higher than that for human constructions. Inter-grain and inter-bolus cementation, in addition to matrix suction due to the partial saturation conditions, have been suggested as major contributors to mound stability11.
The enhanced porosity of the periphery may allow termite mounds to act as temperature and relative humidity ‘stabilisers' maintaining high relative humidity (> 98%), high levels of CO2 and moderate temperatures compared to the outside13. These conditions are crucial for the survival of O. obesus termites and their fungal gardens13. We have previously shown that termites manipulate soil in the presence of moisture for manufacturing bricks (boluses) which they use for mound construction9. Boluses deposited during construction coalesce and form a uniform mass of soil with fine capillaries9. Studies with model porous materials made from glass beads have been used to study the effect of textural layering in moisture retention16. Studies with both horizontal and vertical layering of coarse and fine particles show that finer particles draw moisture from the coarse grains resulting in moisture retention for a long time between the fine particles16. This phenomenon has been used in agriculture for retention of soil moisture using a ‘mulch’ layer17. The dense core and porous periphery of termite mounds demonstrated in our study is analogous to a coarse over fine configuration of glass beads15 which can help in moisture retention inside a termite mound.
Tomography of the mounds of other mound-building termites such as Microcerotermes nervosus and Macrognathotermes spp. revealed that in the mounds of these species macro-pores are evenly distributed in the mound interior while the external walls are relatively thick and porous18. The mounds of Tumulitermes pastinator had thick dense outer walls and thin interior walls18 (similar to fine over coarse textural layering). Both these cases exhibit a sharp contrast to the mounds of O. obesus where the core of the mound has broad tunnels (see Supplementary Fig. S1 online) (not macro-pores) and has higher density than the exterior (similar to coarse over fine or mulch configuration mentioned above). However, it is noteworthy that out of the four species of termites mentioned above, only O. obesus is a fungus-farming species19. Fungus farming requires maintenance of a highly controlled internal environment especially high relative humidity13. Therefore, a coarse over fine configuration in the mounds of O. obesus will help in reducing moisture loss while enabling optimum gaseous exchange and maintaining extraordinary structural strength and stability. A network of large and small pores in the outer walls of a non-fungus farming species Trinervitermes geminatus has been reported suggesting increased CO2 diffusivity, thermal insulation and quick drainage of water14. However, unlike the mound of Trinervitermes geminatus which is around 0.47 m tall20, the mound of O. obesus is several meters tall and maintains structural integrity for several decades9. Therefore, the architectural design of O. obesus mounds is such that the strong core and supportive buttresses (similar to the buttresses in buildings) provide structural strength while the high permeability of the buttresses facilitates ventilation at the same time.
We conclude that the termite mound of O. obesus is a bi-layered structure with a dense, strong core and porous peripheries enabling regulated heat–mass transfer through its boundaries. This composite structure helps in achieving simultaneously two rather contradictory objectives, i.e. high strength and optimum ventilation. The architectural solutions offered by these termites have wider implications for natural and industrial building technologies.
Materials and methods
Study species and site
Odontotermes obesus is a fungus-farming termite species21 which makes cathedral-shaped, buttressed mounds9. It is widely distributed in India21 with mounds of several meters in height9. The study was conducted at the Indian Institute of Science Campus in Bangalore, India, which has a residual red soil formed from weathering of gneissic bedrock22. The soil is classified as inorganic clay of low plasticity and contains kaolinite and montmorillonite as dominant clay minerals, and quartz, mica and feldspar as non-clay mineral fractions22. It contains 43%, 34% and 23% of sand, silt and clay-sized fractions respectively22. For all analysis presented in this paper, the outermost region of termite mounds with surface conduits directly in contact with the atmosphere was considered as the buttress and the innermost region farthest away from the mound exterior was considered as the mound core. This was determined visually on a case to case basis based on the architecture of individual termite mounds (see Supplementary Fig. S1 online).
Strength of termite mound regions
To understand the scaling of strength with dimensions of mound samples, termite mound slices used by Kandasami et al.11 were obtained and samples were cored out with diameters 2 cm, 2.5 cm and 3.5 cm and standard aspect ratio of 223. These were tested under unconfined compression in a micro Universal Testing Machine (micro UTM) at a displacement of 1 mm/min. The unconfined compressive stress (UCS) for these samples were not significantly different (see Supplementary Fig. S2 online) and were similar to values in Kandasami et al.11 with samples of 6 cm × 3 cm (height: diameter) suggesting no effect of specimen dimension in strength testing; samples of small dimensions could therefore be used for further experiments. This validation was essential since it was not possible to get samples of 6 cm × 3 cm (height: diameter) dimensions from the buttress of the mound due to presence of pits in the mound walls (see Supplementary Fig. S1 online). Samples of 2 cm × 1 cm (height:diameter) were cored out from the core and buttress of the horizontal slices mentioned above. Depending on the availability of samples without channels/tunnels made by termites, 3 to 8 samples were cored out from each location, weighed and their densities were calculated. These samples acted as technical replicates. Samples were oven dried at 50 °C overnight since the mound slices from which they were derived had been stored under laboratory conditions. Samples were then tested under unconfined compression at 1 mm/min displacement and peak compressive stress recorded.
In order to obtain biological replicates, a drill was attached to a sampling tube (see Supplementary Fig. S3 online), and soil samples were obtained from the core and buttress of occupied mounds (N = 6 mounds). Drilling was carried out at 90 cm and 120 cm from the base (see Supplementary Fig. S3 online). Termites repaired the drilled section within 24 h. This method of sample collection, therefore, ensured minimal damage to the mounds. Samples were carefully transported in zip lock bags to minimise moisture loss, were cored to the dimensions 2 cm × 1 cm (height:diameter), were tested under unconfined compression at 1 mm/min displacement and the peak compressive stress was recorded. The in situ moisture content of soil from the core of the occupied mounds was 6–10% and that for the buttress was 0–4%. Some moisture loss was observed during sample testing, which was attributable to moisture loss occurring during sampling and testing.
Brazilian test for tensile strength of mound soil
To determine the tensile strength of termite mound soil, we performed a set of Brazilian or diametral compression tests wherein a disc of diameter 13.70 mm and thickness 6.60 mm24 was subjected to compression (displacement rate = 1 mm/min) under displacement–controlled loading along its diametral plane. Due to the compression load, a tensile stress state develops in the specimen normal to the compressed diameter with peak values near the centre of the specimen (see details in Supplementary, see Supplementary Fig. S4 online). To avoid local failure at compressed ends due to stress concentration, a cushion arc subtending an angle 2α (12°) at the centre of the disc is used to distribute the load uniformly25. With increase in axial displacement, the axial load increases to a peak where a crack initiates near the centre of the specimen and propagates towards the compressed ends instantly. The tensile strength corresponding to this peak load is calculated using σt = 2P/πDt where P is the peak compression load at failure or first drop in the load displacement curve, t is the thickness of the disc and D is the diameter of the disc26.
The tensile strength was estimated for samples extracted from different cross-sections at varying heights. For each cross section of the mound, several tests were performed (slice A2: n for buttress = 3, n for core = 3; slice A4: n for buttress = 2, n for core = 3; slice A7: n for buttress = 1, n for core = 3). The strength among these tests did not vary significantly (see “Results”).
Stability analysis of termite mounds
Slope stability analysis was performed on termite mounds to examine the effect of varying soil density and strength along the radial direction. Two geometrical models, triangular and trapezoidal, of the slope were used in this analysis (see Supplementary Fig. S5 online). The finite element method was used to perform slope stability analysis using a strength reduction factor. The advantage of using finite element-based slope stability analysis is that it does not require any à priori assumption of the failure surface27,28. The termite mound slope was modelled as an axisymmetric domain with an isotropic, homogeneous, linear elastic perfectly plastic Mohr–Coulomb material. The axisymmetric domains were discretized with six noded triangular elements with reduced integration to obtain the global stiffness matrix (see Supplementary Fig. S5 online). Discretization is a prerequisite for performing slope stability analysis using the finite element method. The termite mound was discretized into triangular elements, force balance was performed on each element and the results obtained from individual elements were integrated to obtain the overall slope stability of the mound. The bases of these domains were kept fixed for finite element analysis (soil below the termite mound was not considered). The finite element simulations were performed in Plaxis 2D software. As observed from uniaxial compression test data and density calculations, the strength and density of the mound soil varied in radial directions; to accommodate this variation four sets of model parameters were used (Table S1) for outer buttress, inner buttress, outer core, and inner core (see Supplementary Fig. S5 online). The parameters for inner core and outer buttress were the average of their values along the height of the specimen. For outer core and inner buttress, density and cohesion were linearly interpolated between the inner core and outer buttress. The tensile strength was considered to be constant throughout the domain as obtained in our Brazilian test results using samples from the abandoned mound. Since the soil density is comparable between occupied and abandoned mounds and the cementation is also expected to be the same, the tensile strength is expected to be similar between occupied and abandoned mounds.
Cohesive strength (c) for slope stability analysis is half of the average uniaxial compressive strength. Friction (ϕ) and dilation (ψ) angle were set to zero as the termite soil is predominantly clayey. The parameters used for slope stability analysis are provided in Table S1 online.
In the strength reduction factor method, strength parameters were continuously reduced until slope failure occurred. This method involves the reduction of strength by a strength reduction factor in a step-by-step procedure. The factor of safety corresponds to a stable strength reduction factor over a number of successive steps given that the slope failure is achieved in these steps28. A slope failure is identified by a contiguous surface/curve at the plastic limit (or pre-identified failure shear strain) whose end points lie at the boundary of the slope. The strength reduction factor at failure is approximately equal to the factor of safety as defined in limit equilibrium methods29,30.
Porosity distribution from computed tomography
X-ray computed tomography (XCT) was performed on samples (of diameter ~ 1.3 mm, aspect ratio of one) extracted from buttress and core at different heights for analysing the distribution of pores within mound soil. From the reconstructed XCT data, the scanned volume was segmented into two phases, air voids and termite mound soil, using thresholds corresponding to air–soil gray-level intensity cutoff. A typical slice of scanned volume data is presented in Fig. S6 (see Supplementary Fig. S6 online) along with a binarized image corresponding to air–soil gray level intensity cutoff. In order to obtain the distribution of porosity from the binarized volume data, a probing cube of 101 voxels (~ 1.3 mm) was traversed along all the interior voxels within the specimen with the cube residing completely in the specimen. The size of the pores within the cube is estimated as
Porosity of all interior voxels was determined and frequencies of pore sizes were plotted for core and buttress of slices A2, A4 and A7 (Fig. 4). A total of 18 samples were scanned for this analysis (3 samples each for core and buttress within each slice). The pore sizes were divided into 1,000 bins between 0 and 1 mm for plotting. Any attempt towards reduction in the number of bins (say 500, 250, 200, 125, 100, 50, … bins) led to loss of information and statistical significance between core and buttress (see “Statistical analysis”).
We also calculate the porosity of the whole specimen by the following relation
The porosity measurements for buttress and core at different cross sections are listed in Table 1.
Air permeability of mound soil
To understand the functional significance of the differences in density and strength on the gaseous permeability of termite mound samples, one sample each from the core and buttress at different heights from the abandoned mound was examined (see Supplementary Fig. S1 online). Samples were also obtained from the core and buttress of six occupied mounds by drilling at 0.9 and 1.2 m heights from the base of the mounds. Samples of dimensions 2 cm × 1 cm (height:diameter) were cored and inserted inside custom-made glass T-tubes. The samples were sealed inside the tubes with a commercial adhesive. The adhesive was allowed to dry and harden for 24 h before permeability testing. To ensure that all air flow can be attributed to the permeability of the mound samples alone, it was confirmed that the adhesive itself is impermeable to air in the range of air pressures tested. The set-up used for testing the permeability of termite mound soil was modified from King et al.4. The glass T-tubes with the samples were attached to a source of synthetic air (80% N2, 20% O2, 0% RH) and the flow rate was regulated using mass flow controllers Alicat MFC-100 and Alicat MFC-500 in the range 10–100 sccm (standard cubic centimetres per minute) and 100–500 sccm, respectively. The corresponding pressure was measured using a custom-made 14,000 Pa MEMS (micro-electronic measurement sensor) pressure transducer (0.28% full scale error) (see Supplementary Fig. S7 online). Air flow velocity vs. pressure graphs were plotted for samples from occupied and abandoned mounds. The pressures recorded in our experiment fell beyond the full scale error suggesting that they are not due to measurement error and thus reflect a real phenomenon.
Statistical analysis
We analysed the data using the software package R version 3.3.3 (2017-03-06). Data were tested for normality using the Shapiro–Wilk test. For the data on the scaling of strength in termite mound soil, Mann–Whitney U tests were performed followed by Bonferroni corrections. For the unconfined compressive strength data obtained from the abandoned mound, no significant interactions were found; therefore, a type II analysis of variance (ANOVA)31 was performed using the model: Compressive Strength ~ Height + Region by employing the Anova function in the car package where Compressive Strength denotes peak compressive strength for each sample, Height refers to distance of each slice of the termite mound from the base (A2–A7; Fig. 1 and see Supplementary Fig. S1 online), and Region denotes the region within a slice (core vs. buttress; see Supplementary Fig. S1 online). For compressive strength data from the occupied mound, unpaired t tests were performed to check for differences between core and buttress at 90 cm and 120 cm from the base of the mound. Type II analysis of variance (ANOVA) was performed using the model: Tensile Strength ~ Height + Region by employing the Anova function in the car package where Tensile Strength denotes the tensile strength for each sample (see details in “Methods” and Supplementary; see Supplementary Fig. S4 online), Height refers to distance of each slice of the termite mound from the base (A2, A4, A7; see Supplementary Fig. S1 online), and Region denotes the region within a slice (core vs. buttress; see Supplementary Fig. S1 online). Data for porosity distribution in termite mound wall were analysed using a Kolmogorov–Smirnov (KS) test. Pore size distribution of core and buttress were compared for slices A2, A4 and A7 individually. The actual pore size values were compared using unpaired Mann–Whitney U tests for slices A2, A4 and A7 individually. Since the sample sizes in all these cases were very large, random subsamples were also taken and were subjected to unpaired Mann–Whitney U tests; results showed that the difference between core and buttress remained significant even when the sample was reduced to 1/128th of its original size (only results from original sample size and reduction to 1/128th of sample sizes are shown). Any further reduction would not have provided a representative sample.
Data availability
The data that support the findings of this study are available in the Supplementary Information and also online at https://drive.google.com/drive/folders/14x40HL2_Kzaio5beVCSXw8fKHtVH4Be-?usp=sharing.
References
Schneider, E. & Kay, J. Life as a manifestation of the second law of thermodynamics. Math. Comput. Model. 19, 25–48 (1994).
Djongyang, N., Tchinda, R. & Njomo, D. Thermal comfort: A review paper. Renew. Sust. Energy Rev. 14, 2626–2640 (2010).
Ocko, S. & Mahadevan, L. Collective thermoregulation in bee clusters. J. R. Soc. Interface 11, 20131033 (2013).
King, H., Ocko, S. & Mahadevan, L. Termite mounds harness diurnal temperature oscillations for ventilation. Proc. Natl. Acad. Sci. USA 112, 11589–11593 (2015).
Korb, J. Thermoregulation and ventilation of termite mounds. Naturwissenschaften 90, 212–219 (2003).
Mueller, U. & Gerardo, N. Fungus-farming insects: Multiple origins and diverse evolutionary histories. Proc. Natl. Acad. Sci. USA 99, 15247–15249 (2002).
Tschinkel, W. The nest architecture of the Florida harvester ant Pogonomyrmex badius. J. Insect Sci. 4, 1–19 (2004).
Kleineidam, C., Ernst, R. & Roces, F. Wind-induced ventilation of the giant nests of the leaf-cutting ant Atta vollenweideri. Naturwissenschaften 88, 301–305 (2001).
Zachariah, N., Das, A., Murthy, T. G. & Borges, R. M. Building mud castles: a perspective from brick-laying termites. Sci. Rep. 7, 4692 (2017).
Erens, H. et al. The age of large termite mounds—Radiocarbon dating of Macrotermes falciger mounds of the Miombo woodland of Katanga,. Palaeogeogr. Palaeocl. 435, 265–271 (2015).
Kandasami, R., Borges, R. M. & Murthy, T. G. Effect of biocementation on the strength and stability of termite mounds. Environ. Geotech. 3, 99–113 (2016).
Korb, J. & Linsenmair, K. E. Ventilation of termite mounds: New results require a new model. Behav. Ecol. 11, 486–494 (2000).
Katariya, L., Ramesh, P. & Borges, R. M. Dynamic environments of fungus-farming termite mounds exert growth-modulating effects on fungal crop parasites. Environ. Microbiol. 20, 971–979 (2017).
Singh, K. et al. The architectural design of smart ventilation and drainage systems in termite nests. Sci. Adv. 5, eaat8520 (2019).
Kennedy, R., Cornell, C., Campbell, R., Kaplan, S. & Perla, H. Probabilistic seismic safety study of an existing nuclear power plant. Nucl. Eng. Des. 59, 315–338 (1980).
Kumar, N. & Arakeri, J. H. Evaporation from layered porous medium in the presence of infrared heating. Water Resour. Res. 54, 7670–7687 (2018).
Li, X., Chang, S. X. & Salifu, K. F. Soil texture and layering effects on water and salt dynamics in the presence of a water table: A review. Environ. Rev. 22, 41–50 (2014).
Nauer, P. A., Chiri, E., Souza, D. D., Hutley, L. B. & Arndt, S. K. Technical note: Rapid image-based field methods improve the quantification of termite mound structures and greenhouse-gas fluxes. Biogeosciences 15, 3731–3742 (2018).
Inward, D. J., Vogler, A. P. & Eggleton, P. A comprehensive phylogenetic analysis of termites (Isoptera) illuminates key aspects of their evolutionary biology. Mol. Phylogenet. Evol. 44, 953–967 (2007).
Brossard, M., López-Hernández, D., Lepage, M. & Leprun, J. Nutrient storage in soils and nests of mound-building Trinervitermes termites in Central Burkina Faso: consequences for soil fertility. Biol. Fertil. Soils 43, 437–447 (2007).
Bose, G. Termite Fauna of Southern India (ed. Director, Zoological Survey of India) 189–192 (Zoological Survey of India, Calcutta, 1984).
Rao, S. M. & Revanasiddappa, K. Collapse behaviour of a residual soil. Géotechnique 52, 259–268 (2002).
ASTM International. ASTM D 2166—Standard Test Method for Unconfined Compressive Strength of Cohesive Soil (ASTM International, West Conshohocken, PA, 2006).
ASTM International. ASTM D3967–16, Standard Test Method for Splitting Tensile Strength of Intact Rock Core Specimens (ASTM International, West Conshohocken, PA, 2008).
García, V. J., Márquez, C. O., Zúñiga-Suárez, A. R., Zuñiga-Torres, B. C. & Villalta-Granda, L. J. Brazilian test of concrete specimens subjected to different loading geometries: Review and new insights. Int. J. Concr. Struct. M. 11, 343–363 (2017).
Hondros, G. The evaluation of Poisson’s ratio and the modulus of materials of low tensile resistance by the Brazilian (indirect tensile) test with particular reference to concrete. Aust. J. Appl. Sci. 10, 243–268 (1959).
Griffiths, D. V. Lane slope stability analysis by finite elements. Géotechnique 49, 387–403 (1999).
Brinkgreve, R. B. J., Swolfs, W. M., Engin, E., Waterman, D., Chesaru, A., Bonnier, P.G. & Galavi, V. PLAXIS 2D 2010 User manual, Plaxis bv (2010).
Griffiths, D. V. & Marquez, R. M. Three-dimensional slope stability analysis by elasto-plastic finite elements. Géotechnique 57, 537–546 (2007).
Matsui, T. & San, K. Finite element slope stability analysis by shear strength reduction technique. Soils Found. 32, 59–70 (1992).
Langsrud, Ø. ANOVA for unbalanced data: Use type II instead of type III sums of squares. Stat. Comput. 13, 163–167 (2003).
Acknowledgements
We are grateful to Navakant Bhat of the Centre for Nano Science and Engineering (CeNSE), Indian Institute of Science, for the mass flow controller; MM Nayak and Veera Pandi N. for the MEMS pressure transducer. We thank Alison Erlene Viegas and Sidharthan KG for assistance in permeability testing; SA Shariff for assistance in designing set-ups; A Deepika for assistance in micro-CT; Aditi Vijayan, S Thejaswini, Abitha Chakrapani and Surabhi Chauhan for help in performing experiments. This work benefitted from discussions with Ramesh Kandasami, Shwetabh Yadav and Navneet Kumar. We acknowledge financial support from the Department of Biotechnology-IISc Partnership Programme, Department of Science and Technology-FIST, Council of Scientific and Industrial Research, Ministry of Environment, Forests & Climate Change, Government of India, and the CeNSE facilities funded by Department of Information Technology.
Author information
Authors and Affiliations
Contributions
N.Z., T.G.M. and R.M.B conceived and designed the study; N.Z., S.S., T.G.M. and R.M.B wrote the manuscript; N.Z. performed experiments, S.S. performed the image analysis and the FE analysis, and N.Z. and S.S. analyzed the data; all authors interpreted the data.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zachariah, N., Singh, S., Murthy, T.G. et al. Bi-layered architecture facilitates high strength and ventilation in nest mounds of fungus-farming termites. Sci Rep 10, 13157 (2020). https://doi.org/10.1038/s41598-020-70058-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-020-70058-2
- Springer Nature Limited
This article is cited by
-
Bacterial diversity from soil-feeding termite gut and their potential application
Annals of Microbiology (2023)
-
Building Castles on the Ground: Conversations Between Ecologists and Engineers
Journal of the Indian Institute of Science (2023)
-
Are wood-feeding and fungus-growing termites so different? Comparison of the organization and properties of Microcerotermes pakistanicus and Odontotermes obesus soil constructions in the Western Ghats, India
Insectes Sociaux (2021)