Abstract
The indoor environment is the primary location for the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), largely driven by respiratory particle accumulation in the air and increased connectivity between the individuals occupying indoor spaces. In this study, we aimed to track a cohort of subjects as they occupied a COVID-19 isolation dormitory to better understand the impact of subject and environmental viral load over time, symptoms, and room ventilation on the detectable viral load within a single room. We find that subject samples demonstrate a decrease in overall viral load over time, symptoms significantly impact environmental viral load, and we provide the first real-world evidence for decreased aerosol SARS-CoV-2 load with increasing ventilation, both from mechanical and window sources. These results may guide environmental viral surveillance strategies and be used to better control the spread of SARS-CoV-2 within built environments and better protect those caring for individuals with COVID-19.
Similar content being viewed by others
Introduction
The built environment (BE)1,2, or the spaces that we, as humans, have built for ourselves to work in, inhabit, and enjoy life, play an essential role in mitigating the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19)3. SARS-CoV-2 transmission indoors is almost certainly aided through extended close contact and the accumulation and persistence of aerosolized SARS-CoV-2, largely driven by poor ventilation4,5,6,7,8,9,10,11,12,13,14. Significant effort has gone into the identification of SARS-CoV-2 in a multitude of BE’s4,6,15,16,17,18,19,20,21,22,23,24,25,26,27,28. However, most efforts to understand the environmental contamination associated with COVID-19 individuals have been performed at a single time point, missing critical information about the longitudinal dynamics of that environmental contamination. Additionally, minimal characterization has been performed to understand how symptoms and BE factors such as ventilation, measured in air changes per hour (ACH), impact the total environmental and aerosolized contamination by SARS-CoV-2 within the BE over time.
One common scenario faced by people throughout the world is co-occupation of an indoor space with a COVID-19 positive individual while they themselves are not known to be positive. We sought to characterize the environmental viral load associated with these BE’s as they were occupied for extended periods of time. In order to better understand the longitudinal dynamics associated with the occupation of the BE when suffering from COVID-19, isolation dorm rooms housing residence hall students that tested positive for COVID-19 were sampled throughout the course of the individual’s isolation period, typically allowing for up to 10 days of sample collection. Here, we demonstrate that symptom type and symptom severity are predictive factors for the level of SARS-CoV-2 RNA environmental contamination observed and that environmental contamination decreases as individuals recover. Additionally, we provide the first real-world experimental evidence for the suppression of aerosol viral loads through the use of increased ACH from exhaust air and increased natural ventilation through the use of windows.
Results and discussion
Study population
A total of 35 subjects were recruited, completed an informed consent process, and participated in the study between January and May 2021. All subjects tested positive for SARS-CoV-2 RNA through shallow nasal swabs and qRT-PCR. The study cohort was made up of 17 males and 18 females between the age of 18 and 24 (Table 1). The majority of individuals in the study cohort identified as White (68.6%) followed by Hispanic/Latino/Spanish (14.3%). A full breakdown of the self-identifying ethnicity of the study cohort can be found in Table 1.
Viral shedding and environmental contamination associate with isolation day
In an attempt to assess the viral load dynamics over the course of the study cohort’s time in the isolation dormitory, the mean CT, a proxy for observed total viral load, of each study participant from each location was tracked throughout the course of the isolation period. CT values of subject shallow nasal and mouth swabs were found to be significantly (P < 0.05) associated with day since positive test, with CT values increasing (lower viral load) as time since positive test increases (Fig. 1). Additionally, significant increases in CT values were observed as time progressed in environmental swabs taken from the study subject’s computer, phone, the settling plate closest to the study participant, and in the active air samples (AerosolSense). Statistically significant increases in the CT values of participant bathroom floors, bathroom exhaust, and far passive air settling plate were not observed, although nearly all sample types trended towards increased CT values over time. Furthermore, environmental samples (environmental swabs, settling plates, and active air samples) demonstrated decreasing percent positivity over time (Fig. 2).
Increasing nasal and mouth CT values and decreasing rate of positivity of environmental samples as the isolation period progresses both suggest that decreasing viral load in study participants directly translates to decreased viral load within the space occupied by individuals positive for COVID-19 (Figs. 1, 2). While previous investigations have demonstrated the presence of SARS-CoV-2 RNA in BE’s occupied by COVID-19 positive individuals4,15,20,26,28,29, this represents the first link between infection stage, subject viral load over time, and environmental viral load. Additionally, we confirm the findings of multiple other studies that have demonstrated the persistence of SARS-CoV-2 genetic material in patient-derived samples at the end of a treatment and/or isolation period30,31. The persistence of environmental SARS-CoV-2 genomic material has been cited as a potential limitation in multiple sampling campaigns that utilize surface swabs to assess contamination24,32. The strongest trends in increasing CT values among environmental samples were observed in the phone and computer swabs, and AerosolSense active air samples. In comparison to samples that did not demonstrate a significant increase in CT values over time (bathroom exhaust and bathroom floor), these sampling locations were either cleaned in between sampling (phone and computer) or utilize a fresh substrate during each collection period (AerosolSense). This comparison suggests that relic RNA may compose at least a part of the RNA collected in some sampling methods and that routinely cleaned or sampling types more resistant to relic RNA collection (such as active air sampling) may provide more utility as a surveillance tool against SARS-CoV-2 than typical environmental swabbing campaigns.
Symptom presence impacts viral shedding and environmental contamination
The presence (or lack thereof) of symptoms associated with COVID-19 positive individuals and associated viral load in patient samples (nasopharyngeal and oral swabs) has been investigated in a multitude of previous articles and significant differences have not been identified in the viral load associated with symptomatic versus asymptomatic COVID-19 infections33,34,35,36,37,38,39,40,41. Similarly, limited data regarding the relationship between symptomatic infection and environmental contamination are available and warrants continued investigation42. Among the symptoms that were reported by the study population, seven symptoms (coughing, watering eyes, sore throat, loss of smell, GI symptoms, congestion, and brain fog) were found to be significantly associated with altered levels of viral load in the isolation dormitory rooms (Table 2). Increased self-reported coughing, sore throat, loss of smell, and GI symptoms were associated with lower environmental CT values (and thus higher viral loads), with GI symptoms and coughing most strongly correlating with decreased CT values (higher viral load). In comparison, watery eyes, congestion, and brain fog were associated with increased CT values (decreased viral load). Coughing while infected with COVID-19 has been estimated to produce significantly more viral particles than normal breathing43. This small cohort study of 35 individuals supports the hypothesis that increased respiratory expulsion from activities such as coughing would result in increased environmental contamination with SARS-CoV-243,44. Furthermore, it is known, through wastewater analysis and sequencing for the surveillance of SARS-CoV-245, that SARS-CoV-2 is readily emitted from and detected in stool samples in nearly half of COVID-19 positive individuals46. Here we observe increased viral load associated with increased GI symptoms, further supporting the potential for a fecal–oral transmission route of SARS-CoV-2 in certain circumstances. Additionally, the other symptoms associated with increased environmental viral load (sore throat and loss of smell) both implicate the upper respiratory tract. Active viral replication has been identified in the upper respiratory tract and suggests that ongoing infection and symptom onset in the upper respiratory tract may indicate increased levels of viral secretion and environmental contamination in buildings47.
We sought to further understand the potential impact that symptoms play in the transmission of SARS-CoV-2 inside of the BE, and particularly, the impact symptom presence may have on subsequent environmental contamination. As such, each entry into a study participant’s room was queried to determine if the participant had self-reported any symptoms during that visit only. Individual entries were sorted into symptomatic and asymptomatic entries and the CT values from each group were compared. Significantly lower CT values (higher viral load; \(\bar{x}=28.2\) vs. \(\bar{x}=29.7\)) were observed in active air samples collected during entries where the participant reported symptoms (Fig. 3a), representing greater aerosolized viral particles present during that collection time. Furthermore, significantly lower CT values (higher viral load) were observed in all aerosol-based sampling methods (active air samples and passive settling plates; \(\bar{x}=31.5\) vs. \(\bar{x}=32.7\) and \(\bar{x}=34.2\) vs. \(\bar{x}=35.5\)) during symptomatic entries (Fig. 3b,c). Lastly, significantly lower CT values (higher viral load) were also observed in environmental swab samples collected during symptomatic visits compared to asymptomatic visits (Fig. 3d; \(\bar{x}=29.6\) vs. \(\bar{x}=32.7\)). All together, these results suggest that the presence of symptoms, even periodically in some individuals, contributes to increased viral shedding and environmental contamination with SARS-CoV-2.
Additionally, some subjects enrolled in the study demonstrated intermittent negative shallow nasal and oral swabs. To understand whether these periods of potentially low viral load further translated to decreased levels of aerosolized viral particles, each entry into a study participant’s room was investigated to determine whether a positive or negative swab shallow nasal and oral swabs separately) was associated with that entry. Significantly lower (\(\bar{x}=29.3 \; \mathrm{vs} \; \bar{x}=32.5)\) CT values (higher viral load) were observed in active air samples collected during entries where the participant returned a positive shallow nasal swab (Fig. 4a). This same statistically significant relationship \((\bar{x}=27.5\; \mathrm{vs} \;\bar{x}=31.9)\) was also observed when grouping samples based upon the result of their oral swabs (Fig. 4b). Some intermittent detection of SARS-CoV-2 RNA in the later stages of infection have been previously reported48,49,50. COVID-19 has been associated with a significant numbers of super spreader events8,51,52,53. It has been suggested that as low as 2% of COVID-19 positive individuals may account for up to 20% of confirmed cases51. Here, we find a potential relationship between intermittent positivity, symptom dynamics, and the detectable viral load of the subject and their environment. We hypothesize that individuals suffering from COVID-19 may undergo transient periods of viral shedding that may contribute (among many other factors) to lack of transmission in some exposure events and super spreader transmission in other exposure events.
Built environment factors and environmental viral detectivity
The BE has been demonstrated to be an area of high risk when there is a COVID-19 positive individual occupying the space5,9,10,54,55. Despite initial guidance that SARS-CoV-2 is transmitted through droplets and close interactions between individuals56, it has become readily apparent that a major transmission method is through aerosolized viral particles that remain suspended in the air for extended periods of time4,6,7,11,12,13,14,26. As such, we sought to understand the relationship between a range of air exchange rates in the isolation rooms studied and detectability of aerosolized SARS-CoV-2. The rate of exhausted air was measured from each isolation dorm room and the air changes per hour (ACH) were calculated for each room (see “Materials and methods” for full details). The ACH from mechanically exhausted air in the isolation dorm rooms ranged from 0.16 ACH to 0.93 ACH (Fig. 5a). Current American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) guidelines suggest a minimum of 0.35 ACH for multifamily units, 1.7 ACH for retail spaces, and 2.8 ACH for classrooms57. ACH from mechanical exhaust in the isolation rooms was found to be significantly and positively related to observed CT values (P < 0.01), with increased ACH in the room more likely to produce higher CT values (Fig. 5b). However, a significant decrease in the percent positivity of aerosol samples was not observed (P = 0.43) as ACH increased across study rooms (Fig. 5c). Taken together, these results suggest that, even across a fairly narrow range of ACH, increased ventilation rate decreases the detectable aerosolized viral load within enclosed spaces. However, the lack of decrease in percent positivity suggests that the modest range of ACH values found in this study is not enough to decrease the abundance of viral particles in the enclosed space to an undetectable level. Multiple articles have previously hypothesized that increased ventilation rate would translate to lower airborne viral loads19,58,59,60,61. To our knowledge, this study demonstrates the first real-world experimental evidence of increased ventilation within the built environment contributing to decreased aerosolized viral load.
One common method for increasing the ventilation that is available in the vast majority of BE’s is the operation of windows. Windows can dramatically increase the overall ACH within buildings and other enclosed spaces62. In this case, opening a dorm room window will decrease the pressure on the mechanical ventilation (the exhaust air fan in the bathroom) and increase the efficiency of air movement by the exhaust fan63. More importantly, the opening of a window will often increase the absolute ACH, and not just the measured ACH of the exhaust, in the room through bulk air movement in and out of the open window64. In order to assess the potential impact of window operations on the aerosolized viral load present within the study participant’s rooms, study participants were asked the status of their room windows during the course of the previous sampling period and researchers observed current window operation status at each entry. Samples were split into two groups consisting of (i) the window was open for more than 50% of the sampling period or (ii) the window was open for less than 50% of the sampling period. Samples from aerosol collection methods (AerosolSense and passive settling plates) demonstrated a significant increase in CT values (correlating with a decrease in viral load) when the window was open for more than 50% of the sampling period (Fig. 5d). These results suggest that the increased ventilation that is provided from an open window has the ability to reduce the detectable viral load in the room by half when windows are open (\(\bar{x}=34.4\)) compared to when the windows are closed (\(\bar{x}=33.2\)). Window opening, as suggested by a variety of previous analyses and reviews60,65,66,67,68,69, appears to provide significant reduction in viral load while being a low-cost and low-labor intervention when thermal control, security, and environmental introduction is not a concern.
There are multiple limitations to note in our investigation. Our study population, made up of students living in the university residence halls, is inherently not a representative sample of the broad spectrum of individuals that may contract COVID-19. Particularly, our study population is composed of individuals between the ages of 18 and 24. The age of the individual suffering from COVID-19 has been associated with altered levels of detectable SARS-CoV-2 RNA70 and viral shedding dynamics may differ from that seen in our investigation. Additionally, it is important to note that the sampling locations in the rooms were static while the study participants did have the opportunity to move throughout the room. We anecdotally observed that most study participants either worked at the desk that was located in the room or remained in bed and this led to our naming of the settling plate co-located with the AerosolSense sampler as the “far sampling plate.” However, this is in fact a potentially misleading label if the study participant moved around the room throughout the course of the sampling period. Furthermore, our symptom and window position results are largely based upon the results of self-reported survey data. This survey data may suffer from inconsistencies and misclassification bias, particularly data pertaining to symptom presence and severity71,72,73,74. Lastly, there is a lack of data demonstrating a presence or absence of SARS-CoV-2 viability throughout the course of the study participants’ time in the isolation rooms. SARS-CoV-2 RNA has been demonstrated to remain within patient and environmental samples, even when SARS-CoV-2 viability and infectiousness has ceased75,76,77,78.
Overall, we present a detailed longitudinal analysis of oral, nasal, and environmental viral loads associated with individuals in a quarantine environment. We find that subject samples demonstrate a decrease, but not a ceasing, in overall viral load as their quarantine period progresses. Based upon the self-reported symptoms of study participants, we find that coughing and GI symptoms most strongly correlate with increased environmental contamination, likely through an increase in virus shedding during coughing and bowel activity and movements. Additionally, we demonstrate significant differences in environmental contamination between symptomatic and asymptomatic individuals. Lastly, we provide the first real-world experimental evidence for decreased aerosol viral load with increasing mechanical ventilation levels and demonstrate significantly reduced detectable SARS-CoV-2 in study rooms with open windows compared with those with closed windows. These results are directly applicable to those occupying common spaces with an individual known to be positive for COVID-19. We demonstrate that even asymptomatic infection with SARS-CoV-2 can yield high levels of environmental contamination. However, we also identified that increasing the total ACH within the space occupied by the COVID-19 positive individual can aid in the reduction of the overall viral load present in that environment. Furthermore, we add to the mounting evidence that SARS-CoV-2 is emitted by COVID-19 positive individuals which then disperse into the surrounding space as potentially infectious aerosols. Ideally, individuals should physically distance themselves from positive individuals, avoid shared air spaces, increase ventilation, ensure the COVID-19 positive individual wears a mask to reduce the quantity of emitted virus, and wear a mask themselves indoors.
Materials and methods
Institutional approval and data availability
All protocols regarding to the handling of biological materials were reviewed and approved by Advarra Institutional Biosafety Committee (IBC) (Protocol #PROTO202000132). Advarra IBC is an authorized external IBC for the University of Oregon and is registered with the National Institute of Health (NIH). All protocols relating to human subjects involved in the study were reviewed and approved by the University of Oregon Institutional Review Board (IRB) (Protocol #12292020) and all methods were performed in accordance with the relevant guidelines and regulations.
Subject recruitment
University of Oregon COVID-19 protocols require individuals living in the residence halls to move out of their current residence and occupy an isolation dormitory room during the course of their isolation period (14 days). Individuals positive for COVID-19 were identified through the University of Oregon Monitoring and Assessment Program (MAP)79. Following transfer to the isolation dormitory, individuals were recruited into the program for the duration of their stay at the isolation dormitory or until they wished to be removed from the study.
Subject questionnaire
During the first sampling period, study subjects verbally filled out a questionnaire (1st entry questionnaire) that asked participants about their infection timeline, positive test date, age, biological sex, race and ethnicity, recent travel history, lifestyle, medications taken, and symptom onset and severity. Additionally, study subjects verbally completed a followup questionnaire during each subsequent entry into the room to track their symptoms, medications taken, and the status of the study room windows. The symptoms that were tracked included fever, coughing, sneezing, difficulty breathing, fatigue, headache, aching eyes, watering eyes, sore throat, distorted taste, loss of taste, distorted smell, loss of smell, ringing ears, gastrointestinal (GI) symptoms, congestion, and brain fog. Study participants indicated whether or not they were currently experiencing any of the surveyed or other symptoms and the severity on a scale of 1–5, with 5 being the most severe. All survey answers were self-reported by the study participants.
Airflow monitoring
The rate of air exhausted from the isolation rooms were determined for each room. The only location which is designed to exhaust air from the rooms is through the exhaust air vent located in the bathroom of each unit or an open window. The room air is supplied from either the building common areas (via a roof-top unit supplying 100% outside air) or the dormitory room windows. The velocity of exhausted air from each room was measured by placing a customized adapter with a three inch diameter outlet that rested against the exhaust air grille structural perimeter. A hot wire anemometer (TSI Incorporated, model #9565) with probe (TSI Incorporated, model #964) measured the velocity of flow at the center. The measurement was converted to volumetric flow rate using the equation \(VF=\frac{0.9\times \pi \times {0.25}^{2}}{4}\times V\), where \(V\) is the measured velocity at the center in feet per minute, \(0.25\) is the three inch diameter outlet converted to feet, and \(0.9\) is the conversion factor accounting for peak flow at the center and averaging flow across the area of the hole. The air changes per hour (ACH) flow rate was calculated using the dimensions of the study rooms as described in the architectural plans and the equation \(AC{H}_{F}=\frac{VF\times 60}{v}\), where \(v\) is the volume of the room in cubic feet, \(60\) is the minutes in an hour, and \(VF\) is the calculated volumetric flow rate. Measurements were taken with (1) the hall door, exterior window and, bathroom door closed, and (2) the hall door closed and the exterior window and bathroom door open.
Sample collection
Samples were collected 3–5 times throughout a day with approximately 3 h (and up to 16 h for overnight collection, if participants did not turn off samplers) of sampling time occurring between subsequent sampling times. At each entry, both a mouth and shallow nasal swab were collected from the study participant. Environmental samples were collected through environmental swabs, passive air settling plates, and active air sampling (Fig. 6). Environmental swabs were collected from the participant’s cell phone, computer, bathroom floor, and exhaust air grille located within the bathroom. Flocked nylon fiber oropharyngeal swabs (Typenex Medical LLC, Catalog #SW0202) pre-moistened with DNA/RNA Shield (Zymo Research, Catalog #R1100) were used to thoroughly swab the sampling location (sampling area ~ 600 cm2, except for smaller items such as cellphones) for 15–20 s and returned to 1 mL of DNA/RNA Shield. Subject phones and computers were cleaned with bleach wipes following sampling to remove the residue left behind by the DNA/RNA shield. Settled particulates were captured using both components (base and lid) of standard Petri dishes (Corning Scientific). Following the sampling period, both sides of the Petri dish (sampling area ~ 110 cm2) were swabbed following the protocol described above for environmental swabs. Active air samples were collected using the AerosolSense 2900 sampler (Thermo Scientific, Catalog #121561-00). The AerosolSense sampler works by drawing air into an accelerating impactor at a rate of 200 L/min, causing particles to impact onto a collection substrate. Following the sampling period, the collection substrate was transferred to 1 mL of DNA/RNA Shield using sterilized forceps and transported back to the laboratory. Upon return to the laboratory, the capture media was briefly vortexed, then centrifuged for 2 min at 1500×g to collect all liquid from the collection substrate. Following centrifugation, the collection substrate was discarded.
Molecular analysis
All protocols were performed in a Purifier Logic + Class II, Type A2 biosafety cabinet (LabConco, Catalog #302420001). An aliquot of 400 μL of each sample was used as the input for RNA extraction using the Quick-DNA/RNA Viral Magbead kit (Zymo Research, Catalog #R2141) following the manufacturer’s protocol. Briefly, 800 μL of lysis buffer and 20 μL magnetic beads were added to each well, the plate was sealed, and shaken continuously for 10 min. Following the ten minute incubation, the supernatant was removed, and the lysates were washed four times (1× with MagBead DNA/RNA Wash 1, 1X MagBead with DNA/RNA Wash 2, 2× with 100% ethanol). Nucleic acids were eluted into 50 μL nuclease-free water and stored at − 80 °C until downstream analysis. Successful RNA extraction was confirmed in each sample through the addition of a 5 μL spike-in of Escherichia coli MS2 bacteriophage into each extraction well. Each extraction plate also contained one extraction control containing nuclease-free water instead of sample.
All samples underwent quantitative reverse-transcription polymerase chain reaction (qRT-PCR) analysis using the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, Catalog #A47814). This quadruplex qRT-PCR reaction targets the spike (S), nucleocapsid (N), and RNA-dependent RNA polymerase (RdRP/ORF1ab) genomic regions. Additionally, the assay also targets the Escherichia coli MS2 bacteriophage as an internal process control. The reaction mixtures included 5 μL TaqPath 1-Step Multiplex Mastermix without ROX (Thermo Fisher Scientific, Catalog #A28521), 9 μL nuclease-free water (Invitrogen, Catalog #4387936), 1 µL COVID-19 Real Time PCR Assay Multiplex Mix (Thermo Fisher Scientific, Catalog #A47814), and 5 µL of template RNA. Thermocycling was performed with the QuantStudio5 (Applied Biosystems) using the following cycling conditions: 25 °C for 2 min, 53 °C for 10 min, 95 °C for 2 min, and 40 cycles of 95 °C for 3 s and 60 °C for 30 s. Samples were considered positive if amplification was observed in two of three genome targets with a cycle threshold (CT) value less than or equal to 35 (CT < 35). Each qRT-PCR plate contained a positive RNA control, a no-template control (nuclease-free water), and three extraction controls. All controls performed as expected.
Statistical analyses
Analyses were performed using the statistical programming environment R80. Collected data was assessed for normality using a density plot and quantile–quantile plotting (Supplementary Fig. 1). A slight skew towards lower CT values was observed, likely due to a combination of our selected study population (COVID-positive individuals) and the hard positive-sample cutoff CT of 35. Associations between observed CT values and study subject symptoms were identified through the use of a generalized linear model of the form \(y={\beta }_{1}({x}_{1})+{\beta }_{2}({x}_{2})+...{\beta }_{n}({x}_{n}+E)\) where \(y\) is the observed CT, \({\beta }_{i}\) values are linear regression coefficients for fixed effects \({x}_{i}\), and \(E\) is a vector of errors. Significant changes in CT values over time were identified through linear mixed models of the form \({y}_{i}={X}_{i}\beta +{Z}_{i}{u}_{i}+{\epsilon }_{i}\)81,82 using a restricted maximum likelihood (REML) approach and including the individual occupying the room as a random effect. Student’s t-tests were used to compare differences in observed CT values between sampling groups. Differences were considered significant with P < 0.05.
Data and code availability
All data and code supporting this study and required to recreate the analyses are deposited in Github at https://github.com/BioBE/UO-COVID-Dorms. The packages broom83 (version 0.7.8), dplyr84 (version 1.0.7), flextable85 (version 0.6.6), ggplot286 (version 3.3.5), ggpubr87 (version 0.4.0), ggsignif88 (version 0.6.2), lmerTest89 (version 3.1-3), lme490 (version 1.1-27.1), lubridate91 (version 1.7.10), plyr92 (version 1.8.6), scales93 (version 1.1.1), tidyverse94 (version 1.3.1), viridis95 (version 0.6.1), and wesanderson96 (version 0.3.6) were utilized in the analysis and presentation of all data.
References
National Academies of Sciences, Engineering, and Medicine et al. The Built Environment and Microbial Communities. (National Academies Press (US), 2017).
Horve, P. F. et al. Building upon current knowledge and techniques of indoor microbiology to construct the next era of theory into microorganisms, health, and the built environment. J. Expo. Sci. Environ. Epidemiol. https://doi.org/10.1038/s41370-019-0157-y (2019).
Naming the coronavirus disease (COVID-19) and the virus that causes it. https://www.who.int/emergencies/diseases/novel-coronavirus-2019/technical-guidance/naming-the-coronavirus-disease-(covid-2019)-and-the-virus-that-causes-it. Accessed on 10 August 2021
Lednicky, J. A. et al. Collection of SARS-CoV-2 virus from the air of a clinic within a university student health care center and analyses of the viral genomic sequence. Aerosol. Air Qual. Res. 20, 1167–1171 (2020).
Hamner, L. et al. High SARS-CoV-2 attack rate following exposure at a choir practice—skagit county, washington, March 2020. MMWR Morb. Mortal. Wkly. Rep. 69, 606–610 (2020).
Razzini, K. et al. SARS-CoV-2 RNA detection in the air and on surfaces in the COVID-19 ward of a hospital in Milan, Italy. Sci. Total Environ. 742, 140540 (2020).
Morawska, L. & Cao, J. Airborne transmission of SARS-CoV-2: The world should face the reality. Environ. Int. 139, 105730 (2020).
Liu, J., Huang, J. & Xiang, D. Large SARS-CoV-2 outbreak caused by asymptomatic traveler, China. Emerg. Infect. Dis. 26, 2260–2263 (2020).
Speake, H. et al. Flight-Associated transmission of severe acute respiratory syndrome coronavirus 2 corroborated by Whole-Genome sequencing. Emerg. Infect. Dis. 26, 2872–2880 (2020).
Katelaris, A. L. et al. Epidemiologic evidence for airborne transmission of SARS-CoV-2 during church singing, Australia, 2020. Emerg. Infect. Dis. 27, 1677–1680 (2021).
Nissen, K. et al. Long-distance airborne dispersal of SARS-CoV-2 in COVID-19 wards. Sci. Rep. 10, 19589 (2020).
Somsen, G. A., van Rijn, C., Kooij, S., Bem, R. A. & Bonn, D. Small droplet aerosols in poorly ventilated spaces and SARS-CoV-2 transmission. Lancet Respir. Med. 8, 658–659 (2020).
Dumont-Leblond, N. et al. Positive no-touch surfaces and undetectable SARS-CoV-2 aerosols in long-term care facilities: An attempt to understand the contributing factors and the importance of timing in air sampling campaigns. Am. J. Infect. Control https://doi.org/10.1016/j.ajic.2021.02.004 (2021).
Correia, G., Rodrigues, L., Gameiro da Silva, M. & Gonçalves, T. Airborne route and bad use of ventilation systems as non-negligible factors in SARS-CoV-2 transmission. Med. Hypotheses 141, 109781 (2020).
Ye, G. et al. Environmental contamination of SARS-CoV-2 in healthcare premises. J. Infect. https://doi.org/10.1016/j.jinf.2020.04.034 (2020).
Ryu, B.-H. et al. Environmental contamination of SARS-CoV-2 during the COVID-19 outbreak in South Korea. Am. J. Infect. Control 48, 875–879 (2020).
Ahn, J. Y. et al. Environmental contamination in the isolation rooms of COVID-19 patients with severe pneumonia requiring mechanical ventilation or high-flow oxygen therapy. J. Hosp. Infect. 106, 570–576 (2020).
Jin, T. et al. SARS-CoV-2 presented in the air of an intensive care unit (ICU). Sustain. Cities Soc. 65, 102446 (2021).
Cheng, V.C.-C. et al. Air and environmental sampling for SARS-CoV-2 around hospitalized patients with coronavirus disease 2019 (COVID-19). Infect. Control Hosp. Epidemiol. 41, 1258–1265 (2020).
Fernández-de-Mera, I. G. et al. Detection of environmental SARS-CoV-2 RNA in a high prevalence setting in spain. Transbound. Emerg. Dis. 68, 1487–1492 (2021).
Li, Y. H., Fan, Y. Z., Jiang, L. & Wang, H. B. Aerosol and environmental surface monitoring for SARS-CoV-2 RNA in a designated hospital for severe COVID-19 patients. Epidemiol. Infect. 148, e154 (2020).
Escudero, D. et al. SARS-CoV-2 analysis on environmental surfaces collected in an intensive care unit: Keeping ernest shackleton’s spirit. Intensive Care Med. Exp. 8, 68 (2020).
Ong, S. W. X. et al. Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient. JAMA https://doi.org/10.1001/jama.2020.3227 (2020).
Coil, D. A. et al. SARS-CoV-2 detection and genomic sequencing from hospital surface samples collected at UC davis. PLoS One 16, e0253578 (2021).
Borges, J. T., Nakada, L. Y. K., Maniero, M. G. & Guimarães, J. R. SARS-CoV-2: A systematic review of indoor air sampling for virus detection. Environ. Sci. Pollut. Res. Int. https://doi.org/10.1007/s11356-021-13001-w (2021).
Lednicky, J. A. et al. Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients. Int. J. Infect. Dis. 100, 476–482 (2020).
Horve, P. F. et al. Identification of SARS-CoV-2 RNA in healthcare heating, ventilation, and air conditioning units. Indoor Air 31, 1826–1832 (2021).
Hermesch, A. C. et al. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) environmental contamination and childbirth. Obstet. Gynecol. 136, 827–829 (2020).
van Doremalen, N. et al. Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. N. Engl. J. Med. https://doi.org/10.1056/NEJMc2004973 (2020).
Joukar, F. et al. Persistence of SARS-CoV-2 RNA in the nasopharyngeal, blood, urine, and stool samples of patients with COVID-19: A hospital-based longitudinal study. Virol. J. 18, 134 (2021).
Aranha, C., Patel, V., Bhor, V. & Gogoi, D. Cycle threshold values in RT-PCR to determine dynamics of SARS-CoV-2 viral load: An approach to reduce the isolation period for COVID-19 patients. J. Med. Virol. 93, 6794–6797 (2021).
Zhou, Y., Zeng, Y. & Chen, C. Presence of SARS-CoV-2 RNA in isolation ward environment 28 days after exposure. Int. J. Infect. Dis. 97, 258–259 (2020).
Lavezzo, E. et al. Suppression of a SARS-CoV-2 outbreak in the italian municipality of vo’. Nature 584, 425–429 (2020).
Finelli, C. & Parisi, S. The clinical impact of COVID-19 epidemic in the hematologic setting. Adv. Biol. Regul. 77, 100742 (2020).
Arons, M. M. et al. Presymptomatic SARS-CoV-2 infections and transmission in a skilled nursing facility. N. Engl. J. Med. 382, 2081–2090 (2020).
Zhou, R. et al. Viral dynamics in asymptomatic patients with COVID-19. Int. J. Infect. Dis. 96, 288–290 (2020).
Wei, W. E. et al. Presymptomatic transmission of SARS-CoV-2—singapore, january 23-march 16, 2020. MMWR Morb. Mortal. Wkly. Rep. 69, 411–415 (2020).
Bernal, J. L. et al. Transmission dynamics of COVID-19 in household and community settings in the united kingdom. bioRxiv https://doi.org/10.1101/2020.08.19.20177188 (2020).
Decker, A. et al. Prolonged SARS-CoV-2 shedding and mild course of COVID-19 in a patient after recent heart transplantation. Am. J. Transplant 20, 3239–3245 (2020).
Folgueira, M. D., Luczkowiak, J., Lasala, F., Pérez-Rivilla, A. & Delgado, R. Persistent SARS-CoV-2 replication in severe COVID-19. bioRxiv https://doi.org/10.1101/2020.06.10.20127837 (2020).
van Kampen, J. J. A. et al. Duration and key determinants of infectious virus shedding in hospitalized patients with coronavirus disease-2019 (COVID-19). Nat. Commun. 12, 267 (2021).
Santarpia, J. L. et al. Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care. Sci. Rep. 10, 12732 (2020).
Riediker, M. & Tsai, D.-H. Estimation of viral aerosol emissions from simulated individuals with asymptomatic to moderate coronavirus disease 2019. JAMA Netw. Open 3, e2013807–e2013807 (2020).
Wang, Y., Xu, G. & Huang, Y.-W. Modeling the load of SARS-CoV-2 virus in human expelled particles during coughing and speaking. PLoS One 15, e0241539 (2020).
Peccia, J. et al. Measurement of SARS-CoV-2 RNA in wastewater tracks community infection dynamics. Nat. Biotechnol. 38, 1164–1167 (2020).
Parasa, S. et al. Prevalence of gastrointestinal symptoms and fecal viral shedding in patients with coronavirus disease 2019: A systematic review and meta-analysis. JAMA Netw. Open 3, e2011335–e2011335 (2020).
Schulze, J. et al. Analysis of severe acute respiratory syndrome 2 replication in explant cultures of the human upper respiratory RTract reveals broad tissue tropism of wild-type and B.1.1.7 variant viruses. J. Infect. Dis. 224, 2020–2024 (2021).
AlJishi, J. M. & Al-Tawfiq, J. A. Intermittent viral shedding in respiratory samples of patients with SARS-CoV-2: Observational analysis with infection control implications. J. Hosp. Infect. 107, 98–100 (2021).
Li, N., Wang, X. & Lv, T. Prolonged SARS-CoV-2 RNA shedding: Not a rare phenomenon. J. Med. Virol. 92, 2286–2287 (2020).
Liu, W.-D. et al. Prolonged virus shedding even after seroconversion in a patient with COVID-19. J. Infect. 81, 318–356 (2020).
Lau, M. S. Y. et al. Characterizing superspreading events and age-specific infectiousness of SARS-CoV-2 transmission in georgia, USA. Proc. Natl. Acad. Sci. U. S. A. 117, 22430–22435 (2020).
Parhizkar, H., Van Den Wymelenberg, K. G., Haas, C. N. & Corsi, R. L. A quantitative risk estimation platform for indoor aerosol transmission of COVID-19. Risk Anal. https://doi.org/10.1111/risa.13844 (2021).
Majra, D., Benson, J., Pitts, J. & Stebbing, J. SARS-CoV-2 (COVID-19) superspreader events. J. Infect. 82, 36–40 (2021).
Jianyun, L. et al. COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020. Emerg. Infect. Dis. J. 26, 2789–2791 (2020).
Thanh, H. N. et al. Outbreak investigation for COVID-19 in Northern Vietnam. Lancet Infect. Dis. 20, 535–536 (2020).
Escandón, K. et al. COVID-19 false dichotomies and a comprehensive review of the evidence regarding public health, COVID-19 symptomatology, SARS-CoV-2 transmission, mask wearing, and reinfection. BMC Infect. Dis. 21, 710 (2021).
The American Society of Heating, Refrigerating and Air Condition Engineers, Inc. (ASHRAE). Ventilation of health care facilities (ANSI/ASHRAE/ASHE standard 170-2017). https://www.academia.edu/40918042/ASHRAE_Standard_170-2017 (2017). Accessed on 10 August 2021
Allen, J. G. & Ibrahim, A. M. Indoor air changes and potential implications for SARS-CoV-2 transmission. JAMA 325, 2112–2113 (2021).
Chia, P. Y. et al. Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients. Nat. Commun. 11, 2800 (2020).
Dietz, L. et al. 2019 novel coronavirus (COVID-19) pandemic: Built environment considerations to reduce transmission. mSystems 5, e00245-20 (2020).
Klompas, M., Baker, M. A. & Rhee, C. Airborne transmission of SARS-CoV-2: Theoretical considerations and available evidence. JAMA 324, 441–442 (2020).
Howard-Reed, C., Wallace, L. A. & Ott, W. R. The effect of opening windows on air change rates in two homes. J. Air Waste Manag. Assoc. 52, 147–159 (2002).
Qian, H. et al. Natural ventilation for reducing airborne infection in hospitals. Build. Environ. 45, 559–565 (2010).
Escombe, A. R. et al. Natural ventilation for the prevention of airborne contagion. PLoS Med. 4, e68 (2007).
Morawska, L. et al. How can airborne transmission of COVID-19 indoors be minimised?. Environ. Int. 142, 105832 (2020).
Nembhard, M. D., Burton, D. J. & Cohen, J. M. Ventilation use in nonmedical settings during COVID-19: Cleaning protocol, maintenance, and recommendations. Toxicol. Ind. Health 36, 644–653 (2020).
Mathai, V., Das, A., Bailey, J. A. & Breuer, K. Airflows inside passenger cars and implications for airborne disease transmission. Sci. Adv. 7, eabe0166 (2021).
Bhagat, R. K., Davies Wykes, M. S., Dalziel, S. B. & Linden, P. F. Effects of ventilation on the indoor spread of COVID-19. J. Fluid Mech. 903, F1 (2020).
Jarvis, M. C. Aerosol transmission of SARS-CoV-2: Physical principles and implications. Front. Public Health 8, 590041 (2020).
Zhou, C. et al. Impact of age on duration of viral RNA shedding in patients with COVID-19. Aging 12, 22399–22404 (2020).
Daniali, H. & Flaten, M. A. What psychological factors make individuals believe they are infected by coronavirus 2019?. Front. Psychol. 12, 667722 (2021).
den Bergh, M. F. Q. K. et al. Prevalence and clinical presentation of health care workers with symptoms of coronavirus disease 2019 in 2 Dutch hospitals during an early phase of the pandemic. JAMA Netw. Open 3, e209673–e209673 (2020).
Nomura, S. et al. An assessment of self-reported COVID-19 related symptoms of 227,898 users of a social networking service in japan: Has the regional risk changed after the declaration of the state of emergency?. Lancet Reg. Health Western Pac. 1, 100011 (2020).
Merckelbach, H., Dandachi-FitzGerald, B., van Helvoort, D., Jelicic, M. & Otgaar, H. When patients overreport symptoms: More than just malingering. Curr. Dir. Psychol. Sci. 28, 321–326 (2019).
Zhang, Y. et al. Prevalence and persistent shedding of fecal SARS-CoV-2 RNA in patients with COVID-19 infection: A systematic review and meta-analysis. Clin. Transl. Gastroenterol. 12, e00343 (2021).
Rawlings, S. A. et al. No evidence of SARS-CoV-2 seminal shedding despite SARS-CoV-2 persistence in the upper respiratory tract. Open Forum Infect. Dis. 7, ofaa325 (2020).
Yang, J.-R. et al. Persistent viral RNA positivity during the recovery period of a patient with SARS-CoV-2 infection. J. Med. Virol. 92, 1681–1683 (2020).
Kang, H., Wang, Y., Tong, Z. & Liu, X. Retest positive for SARS-CoV-2 RNA of ‘recovered’ patients with COVID-19: Persistence, sampling issues, or re-infection?. J. Med. Virol. 92, 2263–2265 (2020).
University of Oregon. Monitoring and assessment program (MAP). https://coronavirus.uoregon.edu/map. Accessed on 10 August 2021
R Core Team. R: A Language and Environment for Statistical Computing. (R Foundation for Statistical Computing, 2021).
Laird, N. M. & Ware, J. H. Random-effects models for longitudinal data. Biometrics 38, 963–974 (1982).
Raudenbush, S. W. & Bryk, A. S. Hierarchical Linear Models: Applications and Data Analysis Methods. (SAGE, 2002).
David, R., Alex, H. & Simon, C. broom: Convert Statistical Objects into Tidy Tibbles. R package version 0.7.8. (2021). https://CRAN.R-project.org/package=broom. Accessed on 10 August 2021
Hadley, W., Romain, F., Lionel, H. & Kirill, M. dplyr: A grammar of data manipulation. R package version 1.0.7. (2021). https://CRAN.R-project.org/package=dplyr. Accessed on 10 August 2021
David, G. flextable: Functions for Tabular Reporting. R package version 0.6.6. (2021). https://CRAN.R-project.org/package=flextable. Accessed on 10 August 2021
Wickham, H. ggplot2: Elegant Graphics for Data Analysis (Springer, 2016).
Alboukadel, K. ggpubr: 'ggplot2' Based Publication Ready Plots. R package version 0.4.0. (2020). https://CRAN.R-project.org/package=ggpubr. Accessed on 10 August 2021
Ahlmann-Eltze, C. & Patil, I. ggsignif: R Package for displaying significance brackets for “ggplot2”. PsyArxiv https://doi.org/10.31234/osf.io/7awm6 (2021).
Kuznetsova, A., Brockhoff, P. B. & Christensen, R. H. B. lmerTest Package: Tests in linear mixed effects models. J. Stat. Softw. 82(13), 1–26. https://doi.org/10.18637/jss.v082.i13 (2017).
Bates, D., Maechler, M., Bolker, B. & Walker, S. Fitting linear mixed-effects models using lme4. J. Stat. Softw. 67(1), 1–48. https://doi.org/10.18637/jss.v067.i01 (2015).
Garrett, G. & Hadley, W. Dates and times made easy with lubridate. J. Stat. Softw. 40(3), 1–25 (2011).
Hadley, W. The split-apply-combine strategy for data analysis. J. Stat. Softw. 40(1), 1–29 (2011).
Hadley, W. & Dana, S. scales: Scale Functions for Visualization. R package version 1.1.1. (2020). https://CRAN.R-project.org/package=scales. Accessed on 10 August 2021
Wickham, et al. Welcome to the tidyverse. J. Open Source Softw. 4(43), 1686. https://doi.org/10.21105/joss.01686 (2019).
Simon, G., Noam, R., Robert, R., Antônio, P. C., Marco, S., & Cédric, S. Rvision—Colorblind-Friendly Color Maps for R. R package version 0.6.1. (2021).
Karthik, R. & Hadley, W. wesanderson: A Wes Anderson Palette Generator. R package version 0.3.6. (2018). https://CRAN.R-project.org/package=wesanderson.
Acknowledgements
The authors would like to thank Chuck Williams and Tony Schaffer, University of Oregon, for their aid in forming a relationship with Thermo Fisher Scientific. The authors would like to thank countless staff members from the University of Oregon. The authors would like to acknowledge the tireless team at the lab, center and instate, for all of their help, including Surbhi Nahata, Kate Qi, Jackson Mestler, Dan Richards, Kathrine Tush, Liliya Zagorski, Marin Nagle, and Ellie Thacker. Most importantly, we would like to extend a special thanks to the study participants who welcomed us during a very stressful event in their lives.
Funding
Funding for this research was partially provided by Thermo Fisher Scientific under award number 4133V1, as well as a confidential gift to the University of Oregon.
Author information
Authors and Affiliations
Contributions
K.G.V.D.W. performed funding acquisition and managed the investigation team. P.F.H., L.G.D., and K.G.V.D.W. conceived of project scope and methodology. K.G.V.D.W. and L.G.D. enrolled and consented study participants. G.B. and P.F.H. performed data curation and initial data exploration. P.F.H developed final analysis scripts, performed final analysis, and created visualizations. P.F.H., L.G.D., G.B., G.M., A.O.M., D.N., V.M., L.B., and H.P. collected field samples and performed laboratory analyses. P.F.H. developed the original manuscript with direction and input from K.G.V.D.W. L.G.D., G.B., G.M., A.O.M., D.N., V.M., L.B., H.P., and K.G.V.D.W. provided manuscript revisions and edits on subsequent manuscript drafts.
Corresponding author
Ethics declarations
Competing interests
KGVDW has a company called Duktile through which he provides healthy building consulting, including consulting related to viral pathogens, and he serves as a scientific advisor to EnviralTech and Poppy, companies that conduct viral surveillance. No other authors have any competing interests to declare.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Horve, P.F., Dietz, L.G., Bowles, G. et al. Longitudinal analysis of built environment and aerosol contamination associated with isolated COVID-19 positive individuals. Sci Rep 12, 7395 (2022). https://doi.org/10.1038/s41598-022-11303-8
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-11303-8
- Springer Nature Limited
This article is cited by
-
Implemented indoor airborne transmission mitigation strategies during COVID-19: a systematic review
Journal of Environmental Health Science and Engineering (2023)