Abstract
Leg movements during sleep occur in patients with sleep pathology and healthy individuals. Some (but not all) leg movements during sleep are related to cortical arousals which occur without conscious awareness but have a significant effect of sleep fragmentation. Detecting leg movements during sleep that are associated with cortical arousals can provide unique insight into the nature and quality of sleep. In this study, a novel leg movement monitor that uses a unique capacitive displacement sensor and 6-axis inertial measurement unit, is used in conjunction with polysomnography to understand the relationship between leg movement and electroencephalogram (EEG) defined cortical arousals. In an approach that we call neuro-extremity analysis, directed connectivity metrics are used to interrogate causal linkages between EEG and leg movements measured by the leg movement sensors. The capacitive displacement measures were more closely related to EEG-defined cortical arousals than inertial measurements. Second, the neuro-extremity analysis reveals a temporally evolving connectivity pattern that is consistent with a model of cortical arousals in which brainstem dysfunction leads to near-instantaneous leg movements and a delayed, filtered signal to the cortex leading to the cortical arousal during sleep.
Similar content being viewed by others
Introduction
Humans, unlike other animals, move almost exclusively upright on two legs that produce intricate patterns of leg movements from simple to complex, orchestrated mostly via the Central Nervous System (CNS). These processes are inhibited during restorative sleep, and dysfunction in this inhibitory neural circuitry, potentially caused by physiological irregularities, can manifest as specific leg movements while a person is asleep. For example, leg movements during sleep can reflect cortical and/or autonomic arousals, which represent significant changes in brain activity accompanied by, transitory increases in blood pressure and heart rate causing significant sleep disturbances1,2,3,4.
Cortical arousals are theorized to occur as complex phenomena within the central nervous system that involves the cortex, thalamus, brainstem, and spinal cord. These arousals are currently observed and characterized by electroencephalography (EEG) that occurs as part of overnight polysomnography (PSG) or home sleep test (HST) studies. The sleeper is generally unaware of these arousals; however, these arousals can have a significant, negative impact5,6,7.
Although the precise pathophysiology relating leg movements during sleep and cortical arousals remains unclear; since leg movements are associated with cortical arousals8,9,10, their measurement is a critical, yet understudied measure of sleep and potential sleep disturbances. Current methods for measuring leg movements during sleep include actigraphy (accelerometer-only based devices) and EMG used in PSG; however, these devices give a limited view of the complex and sometimes subtle movements of lower extremities. For example, since actigraphy uses accelerometers, the leg must move enough to create a detectable signal above noise-levels and thus may miss more subtle, yet critical movements11. Furthermore, leg movements that do not involve the location of the accelerometers would be completely undetected. Alternatively, EMG can detect subtle movement (through the detection of voltage in muscle) but based on its location overlying the anterior tibialis muscle, can only identify leg movements associated with contraction of that muscle which controls dorsiflexion of the foot. Thus, any leg movements involving flexion at the knee or even some rotations of the foot would not be detected.
Given the hypothesized relationship between leg movements of sleep and brain activity, we developed a new analytic technique called neuro-extremity analysis that examines the effective connectivity between brain sensor (EEG) and leg movement sensors to better understand the temporal dependence of activity between the two. The goal of this approach was to better understand the mechanism behind leg movements associated with cortical arousals. Further, given the complexity of leg movements, we hypothesized that different types of leg sensors may show different strengths of leg movement/cortical connections.
In this pilot study, multiple devices were used to measure leg movements during sleep to evaluate their utility in detecting expert-labeled cortical arousal events and to evaluate their relationship with ongoing brain activity determined by EEG. The sensor data used in this study were the two current standards (EMG and accelerometry based), a textile capacitive based sensor and an inertial measurement unit (IMU) consisting of a 3-axis accelerometer, 3-axis magnetometers, and 3-axis gyroscope.
Our results show that in our small sample size of heterogeneous patients, the capacitive sensor data was most useful in prediction of cortical arousals and showed stronger associations with EEG oscillations than either of the more conventionally used sensor modalities. The temporal pattern of coordinated EEG and leg movement sensor activity changes observed in our results are consistent with the model of brainstem dysfunction causing leg movements during sleep that are associated with cortical arousals.
Methods
Participants and data collection
The experimental methods have been previously published12. All studies were approved by the accredited Institutional Review Board at Johns Hopkins University and all procedures followed the standards provided in the 1964 Declaration of Helsinki. All research was performed in accordance with all applicable guidelines and regulations including obtaining informed consent for all participants and/or their legal guardians.
Briefly, subjects were introduced to the experimental protocol which included simultaneous PSG and leg sensor recordings while they slept. For this pilot study, PSG data from 2 adults (one RLS patient off medications and another normal subject with no sleep complaint) and 4 children (3 children with ADHD not on medication and one child with no sleep complaints) was collected simultaneously with a variety of other sensors on the legs. The children ranged in age from 6 to 10 years old.
Materials
Sensors included 6 channels of EEG (O1, O2, C3, C4, F3, F4), 2 channels of EOG, and 2 channels of EMG activity. The bi-lateral anterior tibialis EMG and the video recording of legs and feet provided ground truth of leg movements during sleep. During these studies, participants wore the RestEaze device on both ankles. The RestEaze product is designed to gather high resolution leg movement information and includes the accelerometry, capacitance, gyroscopy, and magnetometer sensors. These recordings supported the algorithm development and are presented here.
Cortical arousal markings
All PSG sleep measures used in the following analyses were obtained by visual scoring of the sleep studies by trained technicians with a careful review and adjustment of the results as needed by a board-certified sleep professional who was also an expert in leg movement and arousal recordings and measurements. All scoring followed the rules established by the American Academy of Sleep Medicine (AASM). Review of the EEG was conducted off-line after the data collection was completed. On average 80 ± 25 (mean ± SD) CAs were found for each participant. Importantly, these CAs were used in subsequent analyses and used as ground truth for CA.
Analysis
EEG and leg sensor data were analyzed with two approaches to explore the relationship between leg movements and cortical arousals. The initial approach (Approach 1) was used to determine whether information gathered from a variety of sensors on the leg can predict a future cortical event. We use a traditional linear regression analysis and use a metric of explained variance to estimate successful prediction. Our next approach (Approach 2) was more exploratory and used traditional EEG connectivity techniques to investigate the statistical dependencies between the EEG time series and the leg sensor time series.
Approach 1: linear regression
In our first analysis, we tested if the sensor data can be used to predict the occurrence of a cortical arousal using linear regression. In separate regression models, we used the coefficient of variation (CoV, standard deviation divided by the mean) of the data coming from different sensors for a fixed temporal window (t). These data included 3 of each capacitance, gyroscopy, accelerometer, and magnetometer sensors, 2 EMG sensors (Fig. 1A), and an additional measure computed from capacitance sensors, which represented the sum of differential capacitance values across all three capacitance sensors (CDS). This quantity was included given the observed large fluctuation in the measured capacitance values.
Shown as Approach 1 in Fig. 1B, regression was done on a binary dependent variable (Y) which identified if the CoV was calculated for the data t seconds after a CA (Y = 1) or for a randomly selected window of the same length which did not follow the occurrence of a CA (null data, Y = 0). For every CA observed, a null window was identified to be included in the model. For the robustness of this analysis, we conducted 20 regression trials for every stream of the sensor data, and in each trial, required null data windows were selected randomly from the entire duration of the recording.
Regression analysis was done separately for each individual and to compare different sensors as predictors, we used F-statistics, p-values, and R2. Using initial testing, we found a window (t) of 15–30 s to be optimum for the regression models. As a representative comparative metric, we used a standardized R2 (Fig. 1C) for each sensor and subject, which was calculated by subtracting the mean R2 values across all the sensors for a given subject.
Approach 2: neuro-extremity analysis, Granger causal modelling
Our neuro-extremity analysis method calculated time-varying asymmetries between fluctuations in oscillatory activity within the brain and the fluctuations in a variety of sensors placed on the lower extremity. We employed a Granger causal framework to investigate the predictive relationship between the brain activity in the temporal proximity of a clinically defined cortical arousal and sensors specially designed to capture leg movements from a variety of high-resolution sensors. Previous research established that theta (5–8 Hz) rhythms are uniquely tied to sleep and locomotion across species and are used in the scoring of cortical arousals according to v2.6 of the AASM scoring manual. Therefore, in our second approach we focused on theta rhythms.
Granger causal analyses have been used in EEG analyses for some time and have proven a fruitful endeavor to understand how coordinated neural activity may give rise to cognition13,14. We have recently expanded these analytical techniques not only to understand connectivity within the brain, but also to understand how fluctuations in neural activity might explain other variables, like continuous motor behavior15. Largely following this framework, we have expanded these methods to understand: (1) which features of leg movements and cortical arousals, as measured by sensors placed on the leg and scalp, are closely intertwined, (2) the temporal limitations and extent of this relationship, and (3) the extent to which these neuro-extremity relationships may be further explored.
This approach is mainly completed within a few steps that include: (1) preprocessing the EEG and leg sensor data, (2) determining the model parameters, (3) fitting the model, (4) estimating partial directed coherence, (5) statistical testing, and (6) evaluating asymmetry between the brain-predicting-leg and leg-predicting-brain estimations. These steps are detailed below and are roughly depicted in Fig. 2A–C,E.
-
(1)
Because the methods require continuous time series and a generally large amount of time segments to build a predictive model of neuro-extremity connectivity, special care must be considered to discard any perturbations in the signal that might be driven by nuisance factors (e.g., EEG artifact like jaw clenches, poor sensor contact, etc.). Due to some body movement over the > 8 h recording and the limited dataset within this pilot study, we used an artifact subspace removal (ASR) on the electrodes, which decomposes the EEG into principal components in overlapping sliding windows to identify and reject high amplitude components. This method has previously shown to be highly successful in naturalistic EEG data collections16. After this continuous correction of the time series, EEG data were filtered with a low-order (3) butterworth zero-phase filtering scheme. Leg sensor data was not filtered or processed so as to capture any and all possible features from the sensors that might be useful in prediction of (or predicted by) EEG activity surrounding a cortical arousal. Finally, the EEG data were epoched into a 7 s window surrounding the cortical arousal. The leg sensor data was epoched into 7 s windows through the duration of 6 min surrounding the cortical arousal to understand the temporal dynamics of the prediction. Separate autoregressive (AR) models were estimated for each of the leg sensor epochs.
-
(2)
Next, the ARfit toolbox17 was used to implement a stepwise least squares estimation of multivariate auto-regressive (AR) model at a variety of model orders (5–30), and the Schwarz Bayes information criterion (SBC) across the model orders was inspected to find the optimal model order (20) for these complex neuro-extremity relationships. The relatively high model order was used to capture as many possible temporally dependencies as might be available in the time series.
-
(3)
Finally, we calculated the partial directed coherence (PDC), a measure that describes the direction of information flow based on a multivariate decomposition of the partial coherences within complex time varying signals18,19. This resulted in a 21 × 21 matrix for all pair-wise EEG and leg sensor directional relationships.
-
(4)
The PDC estimates, on their own, imply the information flow between two time series derived from a metric that signifies how a time series may predict a future fluctuation in another time series, but they could also signify some inherent predictable feature in both signals. To determine the robustness of the PDC, a null distribution of PDC values was created by randomly rotating the time series of the EEG and leg data. PDC was estimated in the shuffled data, and then all estimates were aggregated. Only the PDC values above (or below) the 95% confidence interval of the null distribution mean were considered. Figure 2C steps through this process showing the mean PDC across all sensors (left panel), then a count of time points that are significantly above (or below) the 95% confidence interval of the null distribution (middle panel), and then finally, the mean PDC when only considering the significant edges (right panel).
-
(5)
Lastly, when estimating the directed connectivity in this dataset, we studied the time course of PDC, specifically to understand the asymmetry in the prediction. We estimated the asymmetry index (AI) as the difference normalized by the sum of each pairwise sensor relationship. If the AI is < 0, then it suggests more that leg sensor measurements can be used to predict the EEG measurements than the EEG sensor measurements can be used to predict the leg sensor measurements. If the AI is > 0, then the opposite is true. After the AI was estimated across the time course, the time-evolving asymmetry matrix was subjected to the same statistical thresholding procedure in (4) and only those significant PDC values were used to estimate the average asymmetry 1 min before the CA and 1 min after the CA, now known as CApre and CApost.
Results
Linear regression suggests capacitance sensor can identify CAs
We used linear regression models for each sensor to test if the coefficient of variation in the sensor time series can dissociate arousal events from non-arousal events (Fig. 1B, also see “Methods” section). We assessed model F-statistics, p-values, and the R2 values to test how each sensor performed. For each sensor stream the mean and standard deviation of the R2 across all channels was displacement capacitive: 0.2 ± 0.12; accelerometers: 0.06 ± 0.072; gyroscope 0.0084 ± 0.008; magnetometers 0.065 ± 0.07; and EMG 0.005 ± 0.0026. In Fig. 1C, we show the standardized R2 calculated for all the sensors across different subjects to summarize our findings. We calculated this quantity by subtracting the mean R2 value observed across all the sensors from the R2 value observed for the given sensor for each subject and regression trial. We found that the capacitance sensors performed the best and separated the arousals from non-arousal reasonably well.
Neuro-extremity analysis reveals special role of capacitance in EEG signal prediction
As a more exploratory approach, to support the analysis in Approach 1, we implemented a neuro-extremity analysis technique that employs an EEG connectivity approach, partial directed coherence (PDC) to inspect the directional information flow between all pairwise sensors. Figure 2 visually describes this analysis technique, which is largely derived from a previous neuro-behavioral analysis used to describe the relationships between the brain and continuous behavioral changes15. This resulted in a series of PDC matrices that represented how well one signal may be used to predict another, from 3 min before the cortical arousal to 3 min after the cortical arousal. To determine whether the value of each cell of the PDC matrix was significant, we estimated a null distribution and only considered values that were higher than the 95% confidence interval surrounding the mean of the null distribution, and then only considered these values in the overall mean (Fig. 2C, right panel). As is observed in Fig. 2C, a structured pattern emerges for each of the panels. First, the overall mean PDC values, without statistical thresholding (Fig. 2C, left panel), shows high mean PDC for connectivity between the EEG sensors. Capacitance (Cap) and EMG sensors also show relatively high mean PDC with directional information flow from the leg sensors to the EEG sensors, without much spatial specificity. Next, the number of significant connections across all 5 subjects and time windows (Fig. 2C, middle panel: 6 total minutes, 241 windows), suggests many of the cells representing the information flow between the EEG sensors and leg sensors show many significant time windows in the cells of the time varying PDC matrix, as compared to the lack of significant pairs within the EEG sensors alone. Finally, when only considering the significant windows, the mean PDC from the Capacitance sensors to the EEG sensors appears to be higher than the alternative direction, suggesting the temporal fluctuations in the leg sensors are more predictive of the EEG signal fluctuations than the alternative.
Finally, to confirm the specificity of the results shown in the mean PDC matrix (Fig. 2C, right), we next summed the significant PDC values over all 6 EEG sensors PDC and inspected the inflow and outflow of each type of leg sensor for each subject. In other words, we were interested in how well each leg sensor measurement was influenced or predicted using the EEG sensors (i.e., inflow) and vice versa (i.e., outflow). Supporting the findings in Fig. 2C, the Cap sensors display the highest overall inflow and outflow with a couple of exceptions in which a subset of the EMG sensors in 2 participants also displayed similarly high inflow and outflow. Interestingly, 2 of the 3 pediatric patients did not have time windows that survived the null model comparison, as the variance in the statistical dependencies between all sensors in the null model was higher than that in the other subjects.
Asymmetry in neuro-extremity analysis suggests a new pathway to investigate brain/body relationships
While the previous summary of results referred to the specificity in EEG-leg sensor prediction, our final step in the neuro-extremity analysis, directly compares the EEG-leg sensor PDC values across time. To perhaps shed light onto the observed relationships and taking advantage of the temporal information present in the time-evolving PDC matrices, we next derived an asymmetry index (AI), which directly estimates the directional bias in PDC values. For illustrative purposes, we only inspect the most robust Cap sensor and specifically ask whether there are pairwise relationships that may change their directional bias in windows before (CApre) and/or after (CApost) the CA. Figure 2F is a visualization of the average asymmetry (considering only significant time windows), of the individual EEG sensors to all of Cap sensors, including the differential sum of all 3 Cap sensors (Cds). We observe that overall, there is a substantial bias in the leg sensors predicting the temporal dynamics of the EEG sensors, and this relationship is especially apparent in the 1 min before a CA (Fig. 2F, compare left and right panels); however, there are a couple of noticeable exceptions, in central and posterior electrodes (C3, O2) for a subset of the Cap sensors. Figure 2G pictorially represents these relationships, with red arrows representing the direction of prediction. These results add to the previous findings that showed perhaps special features in the dynamics of Cap sensors as they can predict CAs and provide a framework to further study brain-corporeal investigations.
Discussion
In this pilot study textile capacitive sensor measurements of the lower extremity were more valuable in discriminating cortical arousals than other sensor modalities and further, these data were more closely related to EEG-theta oscillations near the cortical arousal events. Collectively, these results (1) provide preliminary support that complex leg movements during sleep are associated with cortical arousals and (2) provide preliminary evidence of causal connections (neuro-extremity analysis) between these leg movements and the brain during cortical arousals.
Leg movements during sleep can be significant biomarkers for cortical arousals that reflect significant fragmentation in homeostatic sleep mechanisms and are implicated in multiple sleep disorders20, attention deficit hyperactivity disorder21, neurodegenerative disease22, and cardiovascular disease23. Despite these significant relationships, it is still unknown whether this reflects (i) a process in which dysfunction in the brainstem leads to an immediate movement of the legs with delayed processing through the thalamus to cortex or (ii) somatosensory feedback of the leg movement to cortex, or perhaps a combination of the two mechanisms. Indeed, the emergence of a leg movement during sleep is a complex process involving numerous muscles of the lower extremity and several cortical and subcortical structures24. Because of this complexity, there is significant variability in the type and duration of leg movements during sleep. In this study, using capacitive sensors, we were able to capture and model this complexity in relationship to cortical arousals and EEG dynamics related to those arousals.
The first analysis revealed that the relative variability accounted for in detecting cortical arousals was highest with the capacitive sensors (Fig. 1C). Similarly, the neuro-extremity analysis that examines the connectivity between EEG-theta activity and leg movement sensor data, revealed stronger effective connectivity between the capacitive sensors and EEG-theta oscillations than other sensor modalities (Fig. 2C,D). Capacitive sensors can capture more diverse leg movements during sleep than the other sensors. By design, the capacitive sensors capture relative changes in the electromagnetic field that are generated through changes in lower extremity position. This enables the sensor to capture numerous types of leg movements including those that do not involve the anterior tibialis (muscle used during PSG/EMG studies) nor the physical movement of the ankle itself (e.g. dorsiflexion of the great toe) used by actigraphy (accelerometry based devices). Thus, the present results that show a stronger relationship between these data and EEG-theta activity may be able to capture a more general movement circuit between leg movements and the brain. The other leg sensors used in this study detect leg movements during sleep but are more specific to particular types of movements. For example, the EMG channels used here (and in common practice for PSG) will only detect activation of the anterior tibialis muscle which controls dorsiflexion of the foot but may miss the other movements (e.g. flexion at the knee). Similarly, actigraphy requires that the sensors physically move sufficiently above baseline noise levels for leg movements to be detected. Thus, subtle movements measured by actigraphy may not show relationships to cortical arousals and neural activity that are detected by capacitive sensing.
The neuro-extremity axis analysis reveals an interesting pattern of effective connectivity. The temporal relationship between leg movements and EEG-theta changes shows significant effective connectivity from the leg movement to the cortex before the manually demarcated cortical arousal (Fig. 2F). This implies that leg movements precede detectable changes in EEG before the cortical arousal. After the arousal, there is, similarly, significant outflow from the leg-sensors to EEG, but several EEG-leg sensor pairs that also show the opposite directionality (effective connectivity from EEG to the leg movement time series) emerge during this time.
Collectively, we interpret these findings as representative of a theory suggesting that certain leg movements during sleep (those associated with cortical arousals), originate in the brainstem and signal in two pathways with two different delays25. One pathway, from the brainstem through the spine and to the muscles of the leg which is relatively quick to generate a leg movement. It originates in the brainstem and involves subcortical structures including central pattern generators (CPGs) that are otherwise inhibited during sleep26. The other pathway, from the brainstem through the thalamus and to the cortex is slower relative to the brainstem to leg movement pathway and results in a cortical arousal following a leg movement. The brainstem to cortex pathway is involved with sleep/wake balance and this is likely involved in the sleep fragmentation, cortical arousal associated with the particular leg movements studied in this manuscript27,28.
The current results are consistent with this model. From a temporal perspective, the inciting event is thought to originate in the brainstem in which CPGs create prototypical leg movements during sleep that begin very early in the process. Simultaneously, a delayed signal from the brainstem through the thalamus and to cortex is transmitted resulting in detectable changes in EEG. This signal is detected as an effective connection between the leg movement and EEG changes in Fig. 2F (left) which may be related to the cortical arousal event. As the legs continue to move, the associated cortical activity changes (as measured by EEG) resulting in effective connectivity from EEG to leg movements as shown in Fig. 2F (right). This conceptual model is captured in Fig. 3.
Other studies have shown different temporal patterns of EEG and leg movement activity. Specifically, in periodic leg movement disorder a study demonstrated that delta rhythms precede PSG (EMG-derived) estimates of leg movements which the authors conclude as representative of a cortical origin of periodic leg movements during sleep in Periodic Leg Movement Disorder (PLMD) patients29. Another study has demonstrated similar findings to ours in Restless Leg Syndrome (RLS) patients where significant alpha and beta spectral power changes were observed after the initiation of leg movements with no change in delta range30. There are a few reasons for this discrepancy. First, these two studies used patients with different diagnoses (PLMD vs RLS) which may have different underlying pathophysiology and are associated with different sleep characteristics31. Second, our approach to the measurement of leg movement is unique. Instead of using EMG of the anterior tibialis we used a textile based capacitive sensor. This sensor will detect more leg movements than an EMG probe and thus is better suited to capture more complex leg movements that involve different muscles. Preliminary evidence collected by our group suggests that leg movements begin earlier and last longer than those detected by EMG alone (Brooks et al., under review). Our future work will investigate relationships between additional EEG rhythms (e.g. alpha), leg movements, and additional sleep-related movement disorders.
Conclusions
Leg movements during sleep associated with cortical arousals are complex and poorly understood phenomena. Our preliminary research has provided some additional insight by demonstrating that (1) capacitive sensor data can provide an improved ability to detect cortical arousals based on leg movement data and (2) proposes a neuo-extremity analysis to estimate the temporal dynamics in the EEG-leg movement relationship. Initial implementation of this approach shows consistency with models of brainstem dysfunction as a potential source of leg movements during sleep associated with cortical arousals.
There are a few limitations to consider with this study. First, the sample size is quite small and heterogenous and additional data is needed to further clarify the physiology of leg movements during sleep. Second the sparse locations of the EEG sensors used in this study is poor, thus prohibiting clear interpretation of the functional areas of cortex involved. Finally, additional characterization is needed to understand the precise muscle activations (and subsequent movements) associated with the capacitive time series data. Future research is needed to clarify these points.
Data availability
The data underlying this article will be shared on reasonable request to the corresponding author.
References
Cassel, W. et al. Significant association between systolic and diastolic blood pressure elevations and periodic limb movements in patients with idiopathic restless legs syndrome. Sleep Med. 17, 109–120. https://doi.org/10.1016/j.sleep.2014.12.019 (2016).
Chenini, S. et al. Blood pressure profile and endothelial function in restless legs syndrome. Sci. Rep. 9(1), 15933. https://doi.org/10.1038/s41598-019-52401-4 (2019).
Pennestri, M. H., Montplaisir, J., Colombo, R., Lavigne, G. & Lanfranchi, P. A. Nocturnal blood pressure changes in patients with restless legs syndrome. Neurology 68(15), 1213–1218. https://doi.org/10.1212/01.wnl.0000259036.89411.52 (2007).
Siddiqui, F. et al. Rise of blood pressure with periodic limb movements in sleep and wakefulness. Clin. Neurophysiol. 118(9), 1923–1930. https://doi.org/10.1016/j.clinph.2007.05.006 (2007).
Martin, S. E., Engleman, H. M., Deary, I. J. & Douglas, N. J. The effect of sleep fragmentation on daytime function. Am. J. Respir. Crit. Care Med. 153(4), 1328–1332. https://doi.org/10.1164/ajrccm.153.4.8616562 (1996).
Stepanski, E. J. The effect of sleep fragmentation on daytime function. Sleep 25(3), 268–276. https://doi.org/10.1093/sleep/25.3.268 (2002).
Bonnet, M. H. Sleep restoration as a function of periodic awakening, movement, or electroencephalographic change. Sleep 10(4), 364–373. https://doi.org/10.1093/sleep/10.4.364 (1987).
Sforza, E., Juony, C. & Ibanez, V. Time-dependent variation in cerebral and autonomic activity during periodic leg movements in sleep: Implications for arousal mechanisms. Clin. Neurophysiol. 113(6), 883–891. https://doi.org/10.1016/S1388-2457(02)00066-4 (2002).
Sforza, E. et al. EEG and cardiac activation during periodic leg movements in sleep: Support for a hierarchy of arousal responses. Neurology 52(4), 786–786. https://doi.org/10.1212/WNL.52.4.786 (1999).
Montplaisir, J., Boucher, S., Gosselin, A., Poirier, G. & Lavigne, G. Persistence of repetitive EEG arousals (K-alpha complexes) in RLS patients treated with L-DOPA. Sleep 19(3), 196–199. https://doi.org/10.1093/sleep/19.3.196 (1996).
Yang, M. S. et al. Valid measures of periodic leg movements (PLMs) during a suggested immobilization test using the PAM-RL leg activity monitors require adjusting detection parameters for noise and signal in each recording. Sleep Med. 15(1), 132–137. https://doi.org/10.1016/j.sleep.2013.08.788 (2014).
Jha, A. et al. Pilot study: Can machine-learning analyses of movement discriminate between leg movements in sleep (LMS) with vs. without cortical arousals? Sleep Breath. 25, 373. https://doi.org/10.1007/s11325-020-02100-6 (2020).
Friston, K. J. Functional and effective connectivity in neuroimaging: A synthesis. Hum. Brain Mapp. 2(1–2), 56–78. https://doi.org/10.1002/hbm.460020107 (1994).
Friston, K. J. Functional and effective connectivity: A review. Brain Connect. 1(1), 13–36. https://doi.org/10.1089/brain.2011.0008 (2011).
Garcia, J. O. et al. Estimating direction in brain-behavior interactions: Proactive and reactive brain states in driving. Neuroimage 150, 239–249. https://doi.org/10.1016/j.neuroimage.2017.02.057 (2017).
Kothe, C. A. & Makeig, S. BCILAB: A platform for brain-computer interface development. J. Neural Eng. 10(5), 056014. https://doi.org/10.1088/1741-2560/10/5/056014 (2013).
Schneider, T. & Neumaier, A. Algorithm 808: Arfit—A matlab package for the estimation of parameters and eigenmodes of multivariate autoregressive models. ACM Trans. Math. Softw. 27(1), 58–65. https://doi.org/10.1145/382043.382316 (2001).
Baccalá, L. A. & Sameshima, K. Partial directed coherence: A new concept in neural structure determination. Biol. Cybern. 84(6), 463–474. https://doi.org/10.1007/PL00007990 (2001).
Omidvarnia, A., Mesbah, M., O’Toole, J. M., Colditz, P. & Boashash, B. Analysis of the time-varying cortical neural connectivity in the newborn EEG: A time-frequency approach. In: International Workshop on Systems, Signal Processing and Their Applications, WOSSPA, 179–182. https://doi.org/10.1109/WOSSPA.2011.5931445 (IEEE, 2011).
Trotti, L. M. Restless Legs syndrome and sleep-related movement disorders. Contin. Lifelong Learn. Neurol. 23(4), 1005–1016. https://doi.org/10.1212/CON.0000000000000488 (2017).
Pockett, C. & Kirk, V. Periodic limb movements in sleep and attention deficit hyperactivity disorder: Are they related? Paediatr. Child Health 11(6), 355–358. https://doi.org/10.1093/pch/11.6.355 (2006).
Manconi, M. et al. Time structure analysis of leg movements during sleep in REM sleep behavior disorder. Sleep 30(12), 1779–1785. https://doi.org/10.1093/sleep/30.12.1779 (2007).
Mirza, M. et al. Frequent periodic leg movement during sleep is associated with left ventricular hypertrophy and adverse cardiovascular outcomes. J. Am. Soc. Echocardiogr. 26(7), 783–790. https://doi.org/10.1016/j.echo.2013.03.018 (2013).
Steriade, M. Chapter 41: Modulation of information processing in thalamocortical systems: Chairman’s introductory remarks. In Progress in Brain Research Vol. 98 (ed. Steriade, M.) 341–343 (Elsevier, 1993).
Provini, F. et al. Motor pattern of periodic limb movements during sleep. Neurology 57(2), 300–304. https://doi.org/10.1212/WNL.57.2.300 (2001).
Guertin, P. A. Central pattern generator for locomotion: Anatomical, physiological, and pathophysiological considerations. Front. Neurol. 3, 183. https://doi.org/10.3389/fneur.2012.00183 (2013).
Gent, T. C., Bassetti, C. L. & Adamantidis, A. R. Sleep-wake control and the thalamus. Curr. Opin. Neurobiol. 52, 188–197. https://doi.org/10.1016/j.conb.2018.08.002 (2018).
Picchioni, D. et al. Decreased connectivity between the thalamus and the neocortex during human nonrapid eye movement sleep. Sleep 37(2), 387–397. https://doi.org/10.5665/sleep.3422 (2014).
Ferrillo, F. et al. Changes in cerebral and autonomic activity heralding periodic limb movements in sleep. Sleep Med. 5(4), 407–412. https://doi.org/10.1016/j.sleep.2004.01.008 (2004).
Sieminski, M., Pyrzowski, J. & Partinen, M. Periodic limb movements in sleep are followed by increases in EEG activity, blood pressure, and heart rate during sleep. Sleep Breath. 21(2), 497–503. https://doi.org/10.1007/s11325-017-1476-7 (2017).
Eisensehr, I., Ehrenberg, B. L. & Noachtar, S. Different sleep characteristics in restless legs syndrome and periodic limb movement disorder. Sleep Med. 4(2), 147–152. https://doi.org/10.1016/S1389-9457(03)00004-2 (2003).
Acknowledgements
The authors are exceptionally grateful for the insights and ideas provided by the late Richard Allen, Ph.D. We thoroughly enjoyed reviewing earlier versions of this manuscript with him and are excited to continue our understanding of sleep pathology based on his work. We are also grateful to our patients for their time.
Funding
This work was performed at Johns Hopkins Medical Center, the Kennedy Krieger Institute, University of Maryland, Baltimore County, and Tanzen Medical Inc. This work was supported by a Grant from the National Science Foundation, Small Business Innovation Research Phase I Grant, No: 1819626.
Author information
Authors and Affiliations
Contributions
K.B., J.G., N.B., and J.B. performed the analysis and writing of the main manuscript. C.F. and R.R. contributed to the data analysis, signal processing, and data acquisition. C.E. provided significant contributions to the clinical context and neurological modeling. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing interests
JB, CF, RR, and NB are shareholders of Tanzen Medical Inc. All other authors have no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Bansal, K., Garcia, J., Feltch, C. et al. A pilot study to understand the relationship between cortical arousals and leg movements during sleep. Sci Rep 12, 12685 (2022). https://doi.org/10.1038/s41598-022-16697-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-16697-z
- Springer Nature Limited