Abstract
Postpartum hemorrhage (PPH) is one of the most common causes of mortality in obstetrics worldwide. The accuracy of estimated blood loss is a priority in determining appropriate treatment. Will the additional use of a visual aid improve physicians’ accuracy in estimating blood loss compared to the use of a collector bag and baby scale alone? Simulation training sessions created three vaginal delivery scenarios for participants to estimate volumes of blood loss: firstly, using only a collector bag and a baby weight scale and secondly, adding a visual aid depicting known volumes of blood. The primary endpoint was to determine if participants could accurately evaluate blood loss within a 20% error margin. The addition of the visual estimator resulted in overestimation of blood loss. The rates of participants’ estimations were significantly more accurate when using the collector bag with the baby weight scale without the addition of the visual aid; 85.5% versus 33.3% (p < 0.01) for 350 mL, 88.4% versus 50.7% (p < 0.01) for 1100 mL and 88.4% versus 78.3% (p < 0.01) for 2500 mL, respectively. Additional use of a visual aid with a collector bag does not seem to be useful in improving the accuracy in the estimation of blood loss.
Similar content being viewed by others
Introduction
Postpartum Hemorrhage (PPH) occurs in 5% to 10% of all deliveries1 worldwide. It is the primary cause of morbidity and mortality in the obstetrical field as well as the first cause of admission into the intensive care unit for the postpartum woman1,2,3,4. Worldwide, 25% of maternal deaths are due to PPH5. According to the Royal College of Obstetricians and Gynaecologists (RCOG)6 and the most recent French guidelines released in 20141,4, PPH is defined by a minimum of 500 ml of blood loss within the first 24 hours of delivery and is considered major when the blood loss is more than 1000 ml3,4,6. An inaccurate estimation of blood loss could result in a delay in treatment, which may negatively influence patient care7. In developed countries, at least 60% of the maternal post-natal deaths8 are considered related to suboptimal treatment because of a delay in PPH diagnosis, as well as a delay in management of the third stage of labor, and therefore could be avoided4.
The visual estimation of blood loss by professionals, without using a graduated collector bag, has been evaluated in several studies9,10,11,12 and has been shown to lack accuracy and to underestimate actual blood loss by up to 30%. The percent of inaccuracy also increases as the volume of blood loss increases10. The collector bag is an objective tool used to estimate blood loss with an accuracy of 90%9,13,14,15. It has been used several times in international randomized controlled clinical trials as the primary endpoint to objectively assess PPH16,17,18. All authorities base their PPH definition and threshold to intervene mainly on the amount of blood loss and underline that visual assessment of blood loss is unreliable and underestimates the true blood loss19. However, there is an apparent contradiction as most of them do not recommend any objective tools to be used to measure blood loss before a diagnosis of PPH although they do recommend these tools once the diagnosis is established19,20,21. For example, the Royal College of Obstetricians and Gynaecologists (RCOG)6 stated that “more accurate methods than visual blood loss may be used such as blood collection drapes for vaginal deliveries and weighing swabs” and that “written and pictorial guidelines may help staff working in labour wards to estimate blood loss”. Meanwhile, The French College of Gynecologists and Obstetricians (CNGOF)4 recommends the use of a collector bag only once the PPH diagnosis is established.
To help with PPH assessment, the International Federation of Gynecology and Obstetrics (FIGO) and the RCOG6 organized simulation training sessions such as masterclasses with workshops with the RCOG stating that “participating in clinical reconstructions may encourage early diagnosis and prompt treatment of PPH.”
A recent American study has suggested that a visual aid depicting known volumes of blood on obstetric materials can improve accuracy of blood volume estimation among obstetric providers20. This visual aid is therefore currently used by some obstetric care providers in their protocol for managing the third stage of labor as well as in training simulation sessions6,20. However, the use of a visual aid in association with a collector bag compared to the use of a collector bag and baby scale only in the estimation of postpartum blood loss has not yet been evaluated.
The aim of this study was to determine if the additional use of a visual aid could improve physicians’ accuracy in estimating blood loss compared to the use of a collector bag with baby scale only.
Materials and Methods
A prospective study occurred in a third level maternity ward at a French teaching hospital from October 1st 2013 to October 13th 2013. This prospective study evaluated the accuracy of the obstetrics providers’ estimations of blood loss after a vaginal delivery during training simulation sessions designed to mimic clinical scenarios. All the medical staff, obstetricians and Gynecologists (OG), midwives, and residents in obstetrics and gynecology (OBGYN) were invited to participate. The participants chosen for this study were those that were most likely to be facing a PPH diagnostic situation in the delivery room. Participants volunteered to participate in the study and were aware of being tested on the estimation of blood loss. During both parts of the two part study, each participant’s estimation was compared to an actual volume of blood loss which was only known by the researchers. Each participant had to evaluate blood loss for three different volume scenarios for each part of the study. They consequently had six volumes to estimate. The three blood loss volumes were identical for both parts of the study and were 350 ml, 1100 ml and 2500 ml. However, the ordering of these volume estimating scenarios was randomly assigned by a computer program for both parts of the study resulting in varying sequencing of scenarios among participants. For each participant, the estimation of postpartum blood loss was made on the same day for both parts of the study. In the delivery room where the study occurred, participants had to estimate postpartum blood loss (in the graduated collector bag and on different obstetrical materials around the mannequin) within two minutes to recreate a more time sensitive clinical environment. The fluid used to recreate blood was in color and density similar to real blood. To determine participant characteristics, each of the participants was asked to fill out a questionnaire.
First part of the study: use of a collector bag and baby scale to evaluate postpartum blood loss
All three blood loss scenarios recreated a normal vaginal delivery. The training session is described as follows: in a delivery room, a mannequin was placed in the lithotomy position with a graduated collector bag directly underneath it (Medline International France − 44110 Chateaubriand, FRANCE - reference DGFMA173), and the delivery equipment nearby. This collector bag is used routinely by our caregivers to estimate blood loss after each vaginal delivery in the lithotomy position, which is the current standard position for vaginal deliveries throughout France7. The collector bag as described in this study is a plastic collector bag graduated every 100 ml from zero ml to 1500 ml. Each volume was to be analyzed separately by each individual participant (Fig. 1). There were three volumes to be analyzed: 350 ml, 1100 ml and 2500 ml. This study was designed for participants to assume that the collector bag contained only blood, and that the fluid on the obstetrical equipment nearby was also blood. According to the study, blood loss was contained in the collector bag but also on obstetrics materials such as a kidney dish, hospital sheets, incontinence pad, and sanitary towel. All of the equipment’s weight (prior to the addition of blood) was known and presented on an accessible table in the same room where the simulation training occurred (sanitary towel, incontinence pad, hospital sheets and kidney dish). A baby weight scale was set up on the side to be used by participants if they wanted to weigh the obstetrical materials covered in blood for estimating the three different volumes.
Second part of the study: use of a visual aid depicting known volumes of blood on obstetric materials to estimate blood loss in addition to a collector bag and a baby weight scale
For this second part of the study, the delivery room and the clinical ambiance which recreated a vaginal delivery was identical to that described in the first part of the study above. Participants had to estimate postpartum blood loss for the same three volumes previously analyzed: 350 ml, 1100 ml, and 2500 ml. Estimation of postpartum blood loss during this second part was presumed to be similar to actual clinical PPH situations. Participants had to estimate blood loss while using a visual aid in addition to the identical collector bag and baby weight scale used in part one of the study (Fig. 2).
The visual aid used was a small pocket card containing images of blood loss on common obstetric materials to serve as a reference (Fig. 2). This visual aid has been described and used before in a British study, by Bose and al22 as well as in a recent American study, by Zuckerwise and al20. It is meant to be used to help in the estimation of blood loss when collected on several obstetrical materials such as an incontinence pad or kidney dish20. The trial design uses each participant as their own control (with or without the visual aid). Each participant could consult the visual aid as they were assessing the blood loss contained in the collector bag and on the several obstetrics materials.
Statistical Analysis
The population qualitative parameters were described in numbers and percentage. The quantitative parameters, which were normally distributed, were described by median and standard deviation (SD) as well as interquartile range (IQR). During the first part of the study, for each of the three volumes which participants were asked to estimate, the professionals’ estimation of the blood loss was indicated as a mean of the difference between the estimated volume of blood loss (EBV) and the real volume of blood loss (RBV):[ (EBV-RBV)/RBV+/−SD]. The mean difference found for (EBV – RBV)/RBV is written as a percentage in order to compare all the estimations made on the different RBVs, based on a common unit. The Bland and Altman method23 was used to evaluate the accuracy in between EBV and RBV, using for the first part of the study the collector bag and baby scale and for the second part the visual aid in addition to the collector bag and baby scale. The Bland and Altman method is used to evaluate the agreement between two measurement techniques. In this situation, the Bland and Altman method was used to evaluate obstetrics care providers’ estimations of blood loss while using two different techniques to estimate blood loss in comparison to real blood loss whose volumes were previously known by the researchers. The first technique was the visual estimation of blood loss using a collector bag with a baby weight scale; the second technique was using a visual aid in addition to a collector bag. The limits of agreement were defined as the mean difference plus or minus 1.96SD of the differences (with a 95% confident interval). The differences between the two measurement techniques were plotted against the averages of the two techniques. For each of the three volume loss scenarios, a univariate analysis with a linear regression was used to evaluate if a dependent variable could explain the differences found between the participants’ responses. The Wilcoxon test was used to analyze data for each estimation of blood loss, with or without using a visual aid in addition to the collector bag. For each analysis p ≤ 0.05 was considered as significant.
The primary endpoint was to determine if participants could accurately evaluate blood loss, in each of the three scenarios, within a 20% margin of error. Estimations made that were more than 20% of the real volume of blood loss were considered overestimations, while estimations made that were less than 20% of the real volume of blood loss were considered underestimations12.
Results
Sixty-nine professionals from the maternity ward were available to participate to the study (including fifty-one midwives, ten obstetricians, and eight residents in OBGYN).
Characteristics of the population of the study are described in Table 1.
In all cases, the rates of participant estimations were significantly more accurate when using the collector bag with the baby weight scale without the addition of the visual aid; 85.5% versus 33.3% (p < 0.01) for 350 mL, 88.4% versus 50.7% (p < 0.01) for 1100 mL and 88.4% versus 78.3% (p < 0.01) for 2500 mL, respectively (Table 2). Figure 3a–f represent Bland Altman charts for each of the three scenarios (350 ml, 1100 ml, and 2500 ml) while using a visual scale in addition to the collector bag and while not using the visual scale.
The vertical axis represents the differences in estimation of blood loss and the horizontal axis represents the mean estimation of blood loss. Outcomes demonstrated that, while using a visual aid in addition to a collector bag, the limits of agreement determined by the Bland Altman method reference [−262–239] for each of the three volume analysed (350 ml, 1100 ml, 2500 ml) were outside each of their confidence intervals, and all closer to the +20% margin of acceptability. It demonstrated a tendency of professionals to overestimate blood loss while using the visual aid (Fig. 3b,d and f). Results for the use of the collector bag alone demonstrated that the limits of agreement, for each volume analysed, were mostly included in their confidence interval, however there was an underestimation tendency for the highest volume and an overestimation tendency for the lowest volume (Fig. 3a,c and e).
Discussion
Our results suggest that the additional use of a visual aid with a collector bag and a baby weight scale results in an overestimation of blood loss and is consequently not associated with the improvement of the estimation of blood loss by obstetric care providers.
In fact, during the training sessions which recreated postpartum blood loss after a vaginal delivery, the average estimation of the blood loss when using the collector bag and the baby weight scale was 87.3% accurate, according to our primary endpoint which included a 20% margin of error. While using the visual aid depicting known volumes of blood on obstetric materials (in addition to the collector bag and baby scale), the average estimation was 54.1% accurate. For the higher volume (2500 ml) accuracy was 78.3% and for the lower volume (350 ml) accuracy was reduced even further to 33.3%. Our margin of error of 20% concurred with the current literature as it has been commonly used as a percentage of error that is considered significant in other studies evaluating the accuracy in the estimation of blood loss by professionals working in maternity wards while using a visual scale13,22.
Zuckerwise et al.20 evaluated the use of a visual aid to improve obstetric care providers’ accuracy in the estimation of postpartum blood loss. In this simulation study on 151 participants, Zuckerwise et al. evaluated improvement in estimation of blood loss before and after use of a visual aid. Before using it, estimation of blood loss was only a visual estimation without the use of any other objective tool (such as a collector bag). After, with the use of the visual aid, subjective estimation improvement occurred in 90% of the population, according to the post-test survey. In Zuckerwise et al’s study no other objective tool was used in protocol before the use of the visual aid, to estimate blood loss. Therefore, it appeared to them that a visual aid could be useful to help obstetric providers to objectively estimate, postpartum blood loss. However, several studies have shown that visual estimation only of blood loss was inaccurate and lead to underestimations of up to 32%9,10,11,14,15,22,24,25,26,27,28,29. Interestingly, our study showed an increased accuracy using only a collector bag compared to using a visual aid in addition to a collector bag. The use of such a tool for all deliveries could reduce the underestimation of blood loss and thereby avoid under-treatment for women falsely categorized as not having PPH. Use of a baby weight scale to help health care providers on their blood loss estimation should be part of every PPH diagnosis since it is a very reliable easy access tool with a low cost expenses. These results suggest that a visual aid is not useful and could be, moreover, considered detrimental when providers already use an adequate tool such as a collector bag to assess blood loss. Our study does present some limitations. Obstetrics providers were more familiar with the use of the collector bag which is part of our daily protocol in labor wards for the estimation of blood loss, which could explain a better accuracy in the estimation of postpartum blood loss while using it. Using the visual aid in an effective manner may require practice with feedback about how estimation matches actual blood loss. However, as in real life, when a new tool is being used for the first time, a learning period is necessary before becoming familiar with it. In the Zuckerwise et al. study20 the visual aid was used for the first time as well. Also, this study did not evaluate blood loss, while using the collector bag or the visual aid, during real clinical situations. Thus, there was no maternal outcome improvement rate while using a collector bag and or a visual aid after vaginal deliveries during real clinical situations. Although training simulation sessions are obviously not considered real clinical situations, in our study participants were asked to quickly evaluate blood loss (contained in the collector bag and on different obstetric material) within two minutes to attempt to recreate a more time sensitive clinical environment as in a real clinical situation. For participants to be acting as in a real PPH clinical situation, each training occurred in a delivery room, with artificial blood comparable in color and density to real blood. In addition, each estimation was compared to a known volume, which made our high percentage of accuracy when using the collector bag even more dependable.
Conclusion
The use of a visual aid in addition to a collector bag does not improve obstetric care providers’ estimation of postpartum blood loss. Its use seems to be detrimental and results in a much more frequent overestimation of estimated blood loss which may lead to unnecessary treatment of PPH.
Additional Information
How to cite this article: Brooks, M. et al. Use of a Visual Aid in addition to a Collector Bag to Evaluate Postpartum Blood loss: A Prospective Simulation Study. Sci. Rep. 7, 46333; doi: 10.1038/srep46333 (2017).
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
Deneux Tharaux, C., Bonnet, M. P. & Tort, J. Epidemiology of postpartum haemorrhage. J Gynocol Obstet Biol Reprod (Paris). 43(10), 936–950 (2014).
Khan, K. S., Wojdyla, D., Say, L., Gülmezoglu, A. M. & Van look, P. F. WHO analysis of causes of maternal death: a systematic review. Lancet. 367(9516), 1066–74 (2006).
Tunçalp, O., Souza, J. P. & Gülmezoglu, M. New WHO recommendations on prevention and treatment of postpartum haemorrhage. Int J Gynaecol Obstet, 123(3), 254–6 (2013).
Sentilhes, L., et al. Postpartum Haemorrhage: Guidelines for clinical practice from the French College of Gynaecologists and Obstetricians (CNGOF). Eur J Obstet Gynecol Reprod Biol. 198, 12–21 (2016).
World Health Organization, authors. Maternal mortality in 2005: estimates developed by WHO, UNICEF, UNFPA and the World Bank. Geneva (Switzerland): WHO; 2007.
Royal College of Obstetricians and Gynaecologists (RCOG) Prevention and management of postpartum haemorrhage. Green-top guideline No52. 24p. www.rcog.org.ukhttps://www.rcog.org.uk/globalassets/events/masterclass-in-management-of-pph-programme.pdf (2011).
Driessen, M., Bouvier-Colle, M. H. & Dupont, C. Postpartum haemorrhage resulting from uterine atony after vaginal delivery: factors associated with severity. Obstet Gynecol. 117, 21–31 (2011).
Saucedo, M., Deneux-Tharaux, C. & Bouvier-Colles, M. H. Ten years of confidential inquiries into maternal deaths in France, 1998-2007. Obstet Gynecol. 122(4), 752–60 (2013).
Patel, A., Goudar, S. S., Geller, S. E. et al. Drape estimation vs. visual assessment for estimating postpartum haemorrhage. Int J Gynaecol Obstet. 93(3), 220–4 (2006).
Glover, P. Blood loss at delivery: how accurate is your estimation? Aust J Midwifery. 16(2), 21–4 (2003).
Al kadri, H. M., Al anazi, B. K. & Tamim, H. M. Visual estimation versus gravimetric measurement of postpartum blood loss: a prospective cohort study. Arch Gynecol Obstet. 283(6), 1207–13 (2011).
Toledo, P., Mccarthy, R. J., Hewlett, B. J., Fitzgerald, P. C. & Wong, C. A. The accuracy of blood loss estimation after simulated vaginal delivery. Anesth Analg. 105(6), 1736–40, table of contents (2007).
Legendre, G., Richard, M., Brun, S. et al. Evaluation by obstetric care providers of simulated postpartum blood loss using a collector bag: a French prospective study. J Matern Fetal Neonatal Med. 26, 1–7 (2016).
Tourné, G., Collet, F., Lasnier, P. et al. Usefulness of a collecting bag for the diagnosis of postpartum haemorrhage. J Gynecol Obstet Biol Reprod (Paris). 33(3), 229–34 (2004).
Lilley, G., Burkett-st-laurent, D., Precious, E. et al. Measurement of blood loss during postpartum haemorrhage. Int J Obstet Anesth. 24(1), 8–14 (2015).
Blum, J., Winikoff, B., Raghavan, S. et al. Treatment of post-partum haemorrhage with sublingual misoprostol versus oxytocin in women receiving prophylactic oxytocin: a double-blind, randomised, non-inferiority trial. Lancet. 16, 375(9710), 217–23 (2010).
Sentilhes, L., Daniel, V. & Darsonval, A. TRAAP - TRAnexamic Acid for Preventing postpartum haemorrhage after vaginal delivery: a multicenter randomized, double-blind, placebo-controlled trial. BMC Pregnancy Childbirth. 15, 135 (2015).
Deneux-Tharaux, C., Sentilhes, L., Maillard, F. et al. Effect of routine controlled cord traction as part of the active management of the third stage of labour on postpartum haemorrhage: multicentre randomized controlled trial (TRACOR). BMJ. 346, f1541 (2013).
Sentilhes, L. et al. Comparison of postpartum haemorrhage guidelines: discrepancies underline our lack of knowledge. BJOG (2016).
Zuckerwise, L. C. et al. Use of a novel visual aid to improve estimation of obstetric blood loss. Obstet Gynecol. 123(5), 982–6 (2014).
ACOG Practice Bulletin: Clinical Management Guidelines for Obstetrician-Gynaecologists Number 76, October 2006: postpartum haemorrhage. Obstet Gynecol. 108(4), 1039–47 (2006).
Bose, P., Regan, F. & Paterson-Brown, S. Improving the accuracy of estimated blood loss at obstetric haemorrhage using clinical reconstructions. BJOG. 113(8), 919–24 (2006).
Bland, J. M. & Altman, D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1(8476), 307–10 (1986).
Nelson, G. H. et al. Method for calculating blood loss at vaginal delivery. South Med J. 74(5), 550–2 (1981).
Stafford, I., Dildy, G. A., Clark, S. L. & Belfort, M. A. Visually estimated and calculated blood loss in vaginal and cesarean delivery. Am J Obstet Gynecol. 199(5), 519.e1–7 (2008).
Dildy, G. A., Paine, A. R., George, N. C. & Velasco, C. Estimating blood loss: can teaching significantly improve visual estimation? Obstet Gynecol. 104(3), 601–6 (2004).
Deneux-tharaux, C., Dupont, C., Colin, C. et al. Multifaceted intervention to decrease the rate of severe postpartum haemorrhage: the PITHAGORE 6 cluster-randomised controlled trial. BJOG. 117(10), 1278–87 (2010).
Buckland, S. S. & Homer, C. S. Estimating blood loss after birth: using simulated clinical examples. Women Birth. 20(2), 85–8 (2007).
Weeks, A. The prevention and treatment of postpartum haemorrhage: what do we know, and where do we go to next? BJOG. 122(2), 202–10 (2015).
Author information
Authors and Affiliations
Contributions
The submission of this manuscript is under the consent of each of its authors: M. Brooks (MD), G. Legendre (MD), S. Brun (MD), P.-E. Bouet (MD), L. Pereira Mendes (Ms), B. Merlot (MD), L. Sentilhes (MD-PhD). Author M. Brooks, G. Legendre, L. Sentilhes contributed to the writing of the final manuscript. Author M. Brooks, G. Legendre, L. Sentilhes, L. Pereira Mendes made substantial contributions to the concept and design. Author S. Brun, P.-E. Bouet and B. Merlot made substantial contribution to analysis and interpretation of data. All authors made substantial contribution to drafting and revisions. Each author read and approved the final manuscript and no conflict of interest was reported by any of them. The authors also agree to the inclusion of their names in the list of authors on the manuscript in the order shown on the title page.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Brooks, M., Legendre, G., Brun, S. et al. Use of a Visual Aid in addition to a Collector Bag to Evaluate Postpartum Blood loss: A Prospective Simulation Study. Sci Rep 7, 46333 (2017). https://doi.org/10.1038/srep46333
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/srep46333