Abstract
Background
Myocardial strain imaging has gained importance in cardiac magnetic resonance (CMR) imaging in recent years as an even more sensitive marker of early left ventricular dysfunction than left-ventricular ejection fraction (LVEF). fSENC (fast strain encoded imaging) and FT (feature tracking) both allow for reproducible assessment of myocardial strain. However, left-ventricular long axis strain (LVLAS) might enable an equally sensitive measurement of myocardial deformation as global longitudinal or circumferential strain in a more rapid and simple fashion.
Methods
In this study we compared the diagnostic performance of fSENC, FT and LVLAS for identification of cardiac pathology (ACS, cardiac-non-ACS) in patients presenting with chest pain (initial hscTnT 5–52 ng/l). Patients were prospectively recruited from the chest pain unit in Heidelberg. The CMR scan was performed within 1 h after patient presentation. Analysis of LVLAS was compared to the GLS and GCS as measured by fSENC and FT.
Results
In total 40 patients were recruited (ACS n = 6, cardiac-non-ACS n = 6, non-cardiac n = 28). LVLAS was comparable to fSENC for differentiation between healthy myocardium and myocardial dysfunction (GLS-fSENC AUC: 0.882; GCS-fSENC AUC: 0.899; LVLAS AUC: 0.771; GLS-FT AUC: 0.740; GCS-FT: 0.688), while FT-derived strain did not allow for differentiation between ACS and non-cardiac patients. There was significant variability between the three techniques. Intra- and inter-observer variability (OV) was excellent for fSENC and FT, while for LVLAS the agreement was lower and levels of variability higher (intra-OV: Pearson > 0.7, ICC > 0.8; inter-OV: Pearson > 0.65, ICC > 0.8; CoV > 25%).
Conclusions
While reproducibility was excellent for both FT and fSENC, it was only fSENC and the LVLAS which allowed for significant identification of myocardial dysfunction, even before LVEF, and therefore might be used as rapid supporting parameters for assessment of left-ventricular function.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Background
Strain imaging has gained importance in cardiac magnetic resonance (CMR) imaging in recent years. It allows for very sensitive assessment of myocardial deformation and has been shown to detect subclinical changes in patients with a variety of underlying cardiac conditions such as hypertrophic cardiomyopathy, cardiotoxic cancer therapy patients, ischemic heart disease, heart failure, atrial fibrillation, hypertension, or valvular heart disease [1]. Furthermore, recent data has shown promising results regarding myocardial strain for prognostic information [2].
Several methods exist for strain measurement: recent more rapid techniques include fast-strain encoded imaging (fSENC), feature tracking (FT) and left-ventricular long axis strain (LVLAS).
fSENC uses tag lines that are oriented parallel to the imaging plane from which color-coded images can be generated [3].
A disadvantage of fSENC imaging is the non-measurable radial strain and the need for a separate image acquisition sequence and assessment software. However, it has been proven to be highly reproducible [4] and allows for differentiation between different degrees of infarcted tissue [5]. The advantages of fSENC are its objectivity, reproducibility, short breath-hold times and fast post-processing times[6, 7]. Furthermore, we could recently demonstrate the feasibility of fSENC within a patient population presenting with new onset of chest pain [8].
FT enables the measurement of strain by tracing anatomic elements along the cavity-myocardial interface in cine images. Therefore, no additional images need to be acquired and retrospective analyses of pre-existing datasets can be performed. A disadvantage, however, is its susceptibility to through-plane motion artefacts and partial volume effects [9]. However, it has been shown to detect infarcted territories quite accurately, even allowing discrimination between subendocardial or transmural infarction [10] while remaining highly reproducible [11].
A recently emerging parameter for LV functional assessment is the LVLAS. It has been shown that the major portion of stroke volume is generated by the longitudinal atrioventricular plane movement [12]. As suggested by Riffel et al. the LVLAS is measured as the fractional change in distance between epicardial LV apex and the midpoint between the origin of both mitral valve leaflets calculated in end systole and end diastole [13]. Recent studies suggest that LVLAS is an independent and reproducible predictor for adverse cardiac events in patients with cardiac pathology [14,15,16,17].
All these different strain imaging techniques have their individual advantages and pitfalls, yet no direct comparison of LVLAS to FT/fSENC has been performed so far.
The purpose of this study was to assess and directly compare both GLS (global longitudinal strain) and GCS (global circumferential strain) using fSENC and FT as well as LVLAS within a study population of patients presenting with chest pain. We aimed to explore the diagnostic performance of the different strain techniques for identification of myocardial dysfunction (acute coronary syndrome (ACS) or underlying cardiac pathologies) as well as evaluate correlation of GLS and GCS between the three strain imaging tools.
Furthermore, we hypothesized that LVLAS is comparable to fSENC or FT for LV-function assessment and offers a rapid analysis of myocardial deformation in a simpler and clinically applicable fashion.
Methods
Study population
Patients were prospectively recruited from the chest pain unit of the University Hospital in Heidelberg using a randomized double-blinded single-center study design (consecutive sampling). The inclusion and exclusion criteria for patient enrolment is provided in Table 1.
The CMR scan was performed within a one-hour timeframe before the 2nd hscTnT measurement [18]. Patients were closely monitored (ECG, pulse oximetry, accompanied by a physician during in-hospital transport) at all times. The study was approved by the local ethics committee (Ethikkommission Medizinische Fakultät Heidelberg (S-483/2018)). All participants provided informed written consent and all methods were performed in accordance with the relevant guidelines and regulations.
CMR acquisition
CMR scans were all performed in a 1.5 Tesla whole-body CMR scanner (Ingenia CX 1.5 T, Philips Medical Systems, Best, The Netherlands). A vector ECG was applied for R-wave triggering.
The study protocol included:
-
Standard SSFP cine function images: long axis (LAX) (2, 3 and 4 chamber) and short axis (SAX) (apical, mid, basal)
(FOV 140 mm2, TE 1.38 ms, TR 2.77 ms, flip angle 60°, pixel size 0.88 × 0.88 mm2, 35 acquired phases, slice thickness 8 mm)
-
fSENC images planned on an end systolic timeframe: LAX (2, 3 and 4 chamber) and SAX (apical, mid, basal)
(FOV 100 mm2, TE 0.71 ms, TR 12.16 ms, flip angle 30°, pixel size 1 × 1 mm2, slice thickness 10 mm)
CMR analysis
For FT the software “cvi42” (Circle Cardiovascular Imaging Inc., Calgary, AB, Canada) was applied. Using the “Tissue Tracking” module, GCS and GLS were semi-automatically calculated by averaging peak strain values of individual segments based on the 16-segment model. We also performed a sub-analysis based on artificial intelligence (AI) automated contouring (Fig. 1b).
fSENC images were semi-automatically analyzed after manual contouring of endocardial and epicardial borders (papillary muscles, trabeculae and epicardial fat excluded from blood pool) by the software Myostrain® (Myocardial Solutions, Morrisville, NC, USA). GCS and GLS were reported and represented in color-coded bull’s-eye plots according to the American Heart Association 16-segment model. Longitudinal strain was derived from the SAX images, whereas circumferential strain was gained from the LAX images (Fig. 1a).
LVLAS was calculated in a standard 4-chamber view by measuring the difference in length between the apex to the midpoint of the origin of both mitral valve leaflets between end systole (ES) and end diastole (ED) using the following formula (Fig. 1c):
Intra- and interobserver reproducibility
20 scans for FT and 15 scans for fSENC as well as LVLAS measurement were randomly selected and separately analyzed a second time by the lead study investigator after a period of more than 6 months (no recall bias) as well as another unbiased investigator. All observers are certified experienced readers and were blinded to patients’ final clinical diagnoses.
Reference standard
The reference standard was based on the patient’s final clinical diagnosis as determined by staff cardiologists blinded to our results. Final diagnosis was derived from serial hscTnT testing (4th generation cTnT assay, Roche Diagnostics, Penzberg, Germany [19]) and, if clinically indicated, further diagnostic procedures such as coronary angiography, echocardiography, coronary CT, standard stress CMR or stress ECG.
Statistics
The primary endpoint of this study was to assess the diagnostic performance of LVLAS in comparison to the more established parameter GLS.
Therefore, the null hypothesis was formulated as H0: LVLAS is less accurate at identifying cardiac dysfunction in patients with chest pain than GLS by fSENC and FT.
For all statistical analyses the software programs Excel (Microsoft, Redmond, CA, USA), SPSS (Version 24, IBM, Armonk, USA) and MedCalc (Version 19.2, MedCalc Software, Ostend, Belgium) were used.
Quantitative data is represented with mean values and standard deviation (SD). Receiver Operating Characteristic (ROC) curves were calculated and the area under the curve (AUC) was determined. ROC curves were compared using the Hanley and McNeil test [20]. The data was analyzed using student’s t-test for independent samples and displayed in boxplots. Correlation analysis, intra- and inter-observer analyses were assessed using Pearson’s correlation coefficient as well as intraclass correlation coefficient (ICC). Linear regression analyses and Bland–Altman plots with 95% confidence intervals were drawn to determine levels of bias. P-values < 0.05 were regarded as statistically significant.
Results
Reference standard, study duration
In total, we prospectively recruited 40 patients with chest pain. Of these 40 patients 6 were found to have ACS (n = 3 non-ST-elevation myocardial infarction), another 6 had an underlying cardiac, non-ACS disease (n = 4 septal hypertrophy/hypertensive heart disease; n = 2 hypertrophic cardiomyopathy), while the remaining 28 were determined to have no cardiac cause of the chest pain. Patient characteristics are depicted in Table 2a, b. Gender was evenly distributed (n = 20 female; n = 20 male) with a mean age of 57.1 ± 17.7 years.
All CMR scans were performed with a mean study time of 19.5 ± 5.3 min, including patient preparation and scan time.
ROC curve analysis
ROC curves were drawn for differentiation between cardiac pathology (6 ACS patients and 6 patients with underlying cardiac disease) from non-cardiac chest pain (n = 28).
GCS-fSENC proved to be the strongest parameter for identification of cardiac dysfunction within the study population (AUC: 0.899) closely followed by GLS-fSENC (AUC: 0.882). Notably, LVLAS achieved good results with an AUC of 0.771, while FT strain values demonstrated the weakest performance (GCS-FT AUC: 0.688, GLS-FT AUC: 0.740). GCS-FT differed significantly from GCS- and GLS-fSENC curves (GCS-FT vs. GCS-fSENC p < 0.025; GCS-FT vs. GLS-fSENC p < 0.035), whereas for the other parameters the difference was not significant (Fig. 2).
Triage analysis
In a further analysis patients were triaged according to diagnosis (0: non-cardiac/1: ACS/2: cardiac-non-ACS) and the GLS and GCS (fSENC, FT) as well as LVLAS compared between the three patient groups. Results are depicted in Fig. 3 and Tables 3 and 4.
All strain parameters could significantly (fSENC/FT: p < 0.005; LVLAS: p < 0.02) differentiate between non-cardiac (0) and underlying cardiac disease patients (2).
While GCS-fSENC (p < 0.0025), GLS-fSENC (p < 0.025) and LVLAS (p < 0.05) all allowed for significant differentiation between non-cardiac (0) and ACS patients (1), further separation between ACS (group 1) and other cardiac diseases (group 2) was only possible with GLS-fSENC (p < 0.006). GCS- and GLS-FT while not allowing for distinction between non-cardiac (0) and ACS (1) patients, were significantly different between ACS (1) and cardiac, non-ACS (2) patients (p < 0.02).
Correlation
Correlation coefficients (Pearson and ICC) for the different myocardial deformation parameters are given in Tables 5, 6 and 7. Pearson’s correlation coefficient was notably strong (> 0.5) between GLS-FT and GLS-fSENC as well as between GCS-/GLS-fSENC and LVLAS. The ICC values were good (> 0.75) between GLS-FT and GLS-fSENC. All correlation values were statistically significant (p < 0.05). Linear regression analyses are depicted graphically in scatter plots (Fig. 4) showing a weak linear relationship between GLS as derived by fSENC or FT and compared to the LVLAS (R2 < 0.5). The correlation was strongest, albeit weak, between GLS-fSENC and GLS-FT (R2 = 0.408).
Bland–Altman plots revealed similar levels of variability for GLS (fSENC, FT) and LVLAS (CoV 22.33%; CoV 26.62%). Variability was lowest between GLS as derived by fSENC compared to FT (CoV 18.18%).
Correlation to LVEF, LVESV and LVEDV
We performed a separate analysis regarding the diagnostic accuracy of LVEF, LVESV and LVEDV within our patient cohort. All three values did not allow for significant differentiation between the three patient groups (0: non-cardiac/1: ACS/2: cardiac-non-ACS). Only the LVEDV could significantly distinguish between group 0 and group 2 (p < 0.05). In a ROC curve analysis, the functional parameters showed a weak performance with the LVEDV demonstrating the highest AUC amongst them for identification of myocardial dysfunction (LVEF AUC: 0.485; LVESV AUC: 0.583; LVEDV AUC: 0.686). In a further analysis we correlated the different strain values to LVEF and LVESV/LVEDV. All strain parameters (GLS-FT, GCS-FT, GLS-fSENC, GCS-fSENC, LVLAS) correlated significantly (p < 0.05) to the LVEDV whereas for LVEF and LVESV it was only GLS-FT and GCS-FT which correlated significantly (p < 0.05).
Inter-observer-/intra-observer variability feature tracking
Intra- and inter-observer reliability was excellent for FT (Pearson and ICC > 0.85). Strain values derived by automated contours using AI tools were similarly reproducible (Pearson and ICC > 0.85). All data were statistically highly significant (p < 0.005). Correlation, limits of agreement (LoA), biases and coefficient of variation (CoV) are depicted in Figs. 5, 6 and Tables 8, 9, 10. Variation was lowest between GCS-FT compared to GCS-FT-AI (CoV 5.32%).
Inter-observer-/intra-observer variability fSENC
Intra- and inter-observer reliability for fSENC was excellent and comparable to that of FT (Pearson and ICC > 0.8). All data were statistically highly significant (p < 0.005). Correlation, limits of agreement (LoA), biases and coefficient of variation (CoV) are depicted in Fig. 7 and Tables 11, 12, 13. Variation was lowest for GLS-values (vs. R1 6.80%; vs. R2 4.36%).
Inter-observer-/intra-observer variability LVLAS
While intra-observer reliability was slightly higher (Pearson > 0.7, ICC > 0.8) than inter-observer reliability (Pearson > 0.65, ICC > 0.8), the LVLAS showed lower levels of correlation than FT or fSENC-derived strain values. The correlation data was highly significant (p < 0.005). Correlation, limits of agreement (LoA), biases and coefficient of variation (CoV) are depicted in Fig. 8 and Tables 14, 15. It is evident that variation was markedly higher for LVLAS as compared to FT or fSENC with CoV > 25%.
Discussion
CMR strain imaging has gained more widespread attention in recent years and been shown to be highly reproducible [4, 21,22,23,24]. Reference LV-strain values for FT and fSENC as well as LVLAS have been previously reported [16, 25]. In direct comparison to echocardiographic speckle tracking CMR-derived strain has been shown to correlate significantly to echocardiographic data while being less user-dependent and less subject to suboptimal sonographic conditions [26].
Nevertheless, widespread clinical applicability is hampered by the lack of rapid access to MRI scanners in most institutions [27], a multitude of techniques for strain evaluation [28], and poor inter-vendor agreement [29,30,31]. Additionally, strain values still vary between methods, modalities, and software versions [32] and still lack proper validation [33].
Therefore, more studies regarding feasibility and reproducibility of different CMR-based strain techniques are needed to allow for standardization and subsequently more widespread clinical utilization of myocardial strain.
In our study we directly compared three different methods for assessment of myocardial deformation (FT/fSENC/LVLAS) within a study population of patients with chest pain.
The main findings of our study are the following:
-
1.
LVLAS was comparable to fSENC-derived strain for differentiation between healthy myocardium (non-cardiac chest pain) and myocardial dysfunction (ACS and underlying cardiac pathology) while FT-derived strain showed the weakest performance.
-
2.
GLS-fSENC was the only parameter which allowed for significant patient triage according to final diagnosis (non-cardiac, ACS, cardiac-non-ACS).
-
3.
There was significant variability between the three techniques with moderate correlation of GCS and GLS (FT/fSENC) to LVLAS.
-
4.
Functional parameters (LVEF, LVESV, LVEDV) were less susceptible than strain for identification of cardiac pathologies.
-
5.
Intra- and inter-observer agreement and variability of global strain values were excellent for FT and fSENC.
-
6.
LVLAS showed lower levels of intra- and inter-observer agreement and higher variability than FT or fSENC.
LVLAS is a relatively new method for assessing global left ventricular function – allowing significant discrimination of patients with cardiomyopathies from healthy subjects [13]. Although it has already been shown to predict cardiac events in patients with non-ischemic dilated cardiomyopathy [34], no studies to date have assessed LVLAS performance within an ischemic patient population. Furthermore, no direct comparison of LVLAS to other parameters of myocardial deformation such as global strain has been performed. Reference values have been previously established and set at −17.1 ± 2.3%. Of note, mean values were significantly higher for women and younger people [13]. In our study cohort the LVLAS values were higher (−13.42 ± 3.87%). This may be explained by our relatively young patient population (mean age 57.1 ± 17.7 years).
Interestingly, within our study population LVLAS allowed for similar differentiation between cardiac pathology and non-cardiac disease as fSENC-derived global strain values and demonstrated a better performance than FT. ROC curves did not differ significantly from each other due to the small sample size of patients deemed to be suffering from cardiac pathology and need to be evaluated in a bigger patient population. This data is promising and highlights the usefulness of LVLAS as a rapid alternative approach for the assessment of ventricular function.
FT-derived regional strain has been shown to allow differentiation between areas of myocardial scar and healthy myocardium [35]. We were able to confirm this in our study. However, fSENC-derived global strain as well as the LVLAS proved to be superior to FT-derived global strain for differentiation between healthy and impaired myocardium within our study population. Overall, GCS-fSENC provided a higher accuracy for identification of cardiac dysfunction (AUC: 0.899). However, GLS-fSENC was the only parameter which further allowed for patient triage according to final clinical diagnosis. This is in line with previous studies that have shown GLS to be a feasible alternative to LVEF for the evaluation of myocardial function and risk stratification [36, 37]. Furthermore, GLS has been investigated within a study population of patients following trans-aortic valve replacement and patients undergoing cardiotoxic chemotherapy with good prognostic performance [38, 39].
Correlation between the three modalities was moderate with high variability. GLS-FT and GLS-fSENC showed the best correlation (Pearson > 0.5, ICC > 0.75) with the least variation (CoV = 18.18%). This confirms previous data showing that differences in image acquisition and post-processing analysis may ultimately lead to substantial bias [40, 41]. The fixed position of slices renders FT susceptible to through-plane motion artifacts. fSENC on the other hand, depends on the correct orthogonal positioning of the tag lines with the need for meticulous image planning. More studies are needed to establish validated standardized reference values before fSENC- and FT-global strain data can be rendered comparable.
In general, functional parameters such as LVEF, LVESV and LVEDV per se did not allow for significant identification of the underlying cardiac pathologies within our study cohort. This is in line with previous studies which have indicated that strain is a more sensitive marker of early left ventricular dysfunction than left-ventricular ejection fraction (LVEF) [42, 43]. Interestingly, only the LVEDV allowed for significant differentiation between healthy patients and those suffering from an underlying cardiac disease. This makes sense, as HCM or hypertensive heart disease typically initially present with diastolic dysfunction and only lead to reduced EF in later stages of the disease [44, 45]. All strain parameters correlated significantly only to the LVEDV which underlines the fact that strain as well as the LVEDV were the more susceptible markers for earlier identification of cardiac pathologies within our study cohort.
Intra- and inter-observer analysis was excellent for both FT and fSENC with low levels of variation. However, correlation was lower for LVLAS intra-/inter-observer reliability with higher variation. This stands in contrast to the previous data by Riffel et al. which showed low levels of variability (intra-OV: 5.6 ± 4.2%, inter-OV: 6.3 ± 4.2%) within a larger patient cohort consisting of 40 healthy volunteers and 125 cardiomyopathy patients [13]. This discrepancy may be explained by our smaller sample size (15 patients) leading to a potential larger impact of outliers we were able to observe. Nevertheless, it needs to be noted that the correct calculation of LVLAS is susceptible to several factors such as the correct identification of end systolic and end diastolic phases of the cardiac cycle as well as the accurate definition of the mitral valve ring. We believe with correct training and experience these difficulties can be overcome and LVLAS may be used as a supporting or in certain cases, alternative parameter for assessment of LV function. More studies evaluating accuracy and reproducibility of LVLAS within larger patient samples are required.
Limitations
The main limitation of our study is the relatively small sample size. Additionally, findings were not compared to standard CMR protocols or echocardiographic derived strain data. No extended follow-up was performed—prospective studies are required to evaluate LVLAS as a prognostic parameter.
Conclusions
While reproducibility was excellent for both FT and fSENC. It was only fSENC and the LVLAS which allowed for significant identification of myocardial dysfunction, even with preserved LVEF, and therefore might be used as additional parameters for the assessment of left-ventricular function.
Availability of data and materials
The datasets generated and/or analysed during the current study are not publicly available as the contained information could compromise the privacy of research participants, but are available from the corresponding author on reasonable request.
Abbreviations
- ACS:
-
Acute coronary syndrome
- AI:
-
Artificial intelligence
- AUC:
-
Area under the curve
- BMI:
-
Body mass index
- BP:
-
Blood pressure
- CMR:
-
Cardiac magnetic resonance
- COV:
-
Coefficient of variation
- CT:
-
Computer tomography
- ECG:
-
Electrocardiogram
- EDV:
-
Enddiastolic volume
- ESV:
-
Endsystolic volume
- FOV:
-
Field of view
- fSENC:
-
Fast strain encoded
- FT:
-
Feature tracking
- GCS:
-
Global circumferential strain
- GLS:
-
Global longitudinal strain
- hscTnT:
-
High-sensitivity cardiac troponin T
- ICC:
-
Intraclass correlation coefficient
- IOV:
-
Interobserver variability
- LAX:
-
Long axes
- LoA:
-
Limits of agreement
- LVEF:
-
Left ventricular ejection fraction
- LVLAS:
-
Left ventricular long axis strain
- NYHA:
-
New York Heart Association
- Py:
-
Pack years
- ROC:
-
Receiver operating curve
- SAX:
-
Short axes
- SSFP:
-
Steady-state free precession
- TE:
-
Time to echo
- TR:
-
Time to repeat
References
Abuelkasem E, Wang DW, Omer MA, Abdelmoneim SS, Howard-Quijano K, Rakesh H, Subramaniam K. Perioperative clinical utility of myocardial deformation imaging: a narrative review. Br J Anaesth. 2019;123(4):408–20.
Stiermaier T, Busch K, Lange T, Patz T, Meusel M, Backhaus SJ, Frydrychowicz A, Barkhausen J, Gutberlet M, Thiele H et al. Prognostic value of different CMR-based techniques to assess left ventricular myocardial strain in takotsubo syndrome. J Clin Med 2020;9(12).
Osman NF, Sampath S, Atalar E, Prince JL. Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI. Magn Reson Med. 2001;46(2):324–34.
Giusca S, Korosoglou G, Zieschang V, Stoiber L, Schnackenburg B, Stehning C, Gebker R, Pieske B, Schuster A, Backhaus S, et al. Reproducibility study on myocardial strain assessment using fast-SENC cardiac magnetic resonance imaging. Sci Rep. 2018;8(1):14100.
Oyama-Manabe N, Ishimori N, Sugimori H, Van Cauteren M, Kudo K, Manabe O, Okuaki T, Kamishima T, Ito YM, Tsutsui H, et al. Identification and further differentiation of subendocardial and transmural myocardial infarction by fast strain-encoded (SENC) magnetic resonance imaging at 3.0 Tesla. Eur Radiol. 2011;21(11):2362–8.
Neizel M, Lossnitzer D, Korosoglou G, Schaufele T, Lewien A, Steen H, Katus HA, Osman NF, Giannitsis E. Strain-encoded (SENC) magnetic resonance imaging to evaluate regional heterogeneity of myocardial strain in healthy volunteers: comparison with conventional tagging. J Magn Reson Imaging. 2009;29(1):99–105.
Neizel M, Lossnitzer D, Korosoglou G, Schaufele T, Peykarjou H, Steen H, Ocklenburg C, Giannitsis E, Katus HA, Osman NF. Strain-encoded MRI for evaluation of left ventricular function and transmurality in acute myocardial infarction. Circ Cardiovasc Imaging. 2009;2(2):116–22.
Riffel JH, Siry D, Salatzki J, Andre F, Ochs M, Weberling LD, Giannitsis E, Katus HA, Friedrich MG. Feasibility of fast cardiovascular magnetic resonance strain imaging in patients presenting with acute chest pain. PLoS ONE. 2021;16(5): e0251040.
Muser D, Castro SA, Santangeli P, Nucifora G. Clinical applications of feature-tracking cardiac magnetic resonance imaging. World J Cardiol. 2018;10(11):210–21.
McComb C, Carrick D, McClure JD, Woodward R, Radjenovic A, Foster JE, Berry C. Assessment of the relationships between myocardial contractility and infarct tissue revealed by serial magnetic resonance imaging in patients with acute myocardial infarction. Int J Cardiovasc Imaging. 2015;31(6):1201–9.
Schmidt B, Dick A, Treutlein M, Schiller P, Bunck AC, Maintz D, Baessler B. Intra- and inter-observer reproducibility of global and regional magnetic resonance feature tracking derived strain parameters of the left and right ventricle. Eur J Radiol. 2017;89:97–105.
Carlsson M, Ugander M, Mosen H, Buhre T, Arheden H. Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathy. Am J Physiol Heart Circ Physiol. 2007;292(3):H1452-1459.
Riffel JH, Andre F, Maertens M, Rost F, Keller MG, Giusca S, Seitz S, Kristen AV, Muller M, Giannitsis E, et al. Fast assessment of long axis strain with standard cardiovascular magnetic resonance: a validation study of a novel parameter with reference values. J Cardiovasc Magn Reson. 2015;17:69.
Buss SJ, Breuninger K, Lehrke S, Voss A, Galuschky C, Lossnitzer D, Andre F, Ehlermann P, Franke J, Taeger T, et al. Assessment of myocardial deformation with cardiac magnetic resonance strain imaging improves risk stratification in patients with dilated cardiomyopathy. Eur Heart J Cardiovasc Imaging. 2015;16(3):307–15.
Arenja N, Riffel JH, Fritz T, Andre F, Aus dem Siepen F, Mueller-Hennessen M, Giannitsis E, Katus HA, Friedrich MG, Buss SJ. Diagnostic and prognostic value of long-axis strain and myocardial contraction fraction using standard cardiovascular MR imaging in patients with nonischemic dilated cardiomyopathies. Radiology. 2017;283(3):681–91.
Leng S, Tan RS, Zhao X, Allen JC, Koh AS, Zhong L. Fast long-axis strain: a simple, automatic approach for assessing left ventricular longitudinal function with cine cardiovascular magnetic resonance. Eur Radiol 2020.
Gjesdal O, Almeida AL, Hopp E, Beitnes JO, Lunde K, Smith HJ, Lima JA, Edvardsen T. Long axis strain by MRI and echocardiography in a postmyocardial infarct population. J Magn Reson Imaging. 2014;40(5):1247–51.
Roffi M, Patrono C, Collet JP, Mueller C, Valgimigli M, Andreotti F, Bax JJ, Borger MA, Brotons C, Chew DP, et al. 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC). Eur Heart J. 2016;37(3):267–315.
Giannitsis E, Kurz K, Hallermayer K, Jarausch J, Jaffe AS, Katus HA. Analytical validation of a high-sensitivity cardiac troponin T assay. Clin Chem. 2010;56(2):254–61.
Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143(1):29–36.
Erley J, Zieschang V, Lapinskas T, Demir A, Wiesemann S, Haass M, Osman NF, Simonetti OP, Liu Y, Patel AR, et al. A multi-vendor, multi-center study on reproducibility and comparability of fast strain-encoded cardiovascular magnetic resonance imaging. Int J Cardiovasc Imaging. 2020;36(5):899–911.
Erley J, Genovese D, Tapaskar N, Alvi N, Rashedi N, Besser SA, Kawaji K, Goyal N, Kelle S, Lang RM, et al. Echocardiography and cardiovascular magnetic resonance based evaluation of myocardial strain and relationship with late gadolinium enhancement. J Cardiovasc Magn Reson. 2019;21(1):46.
Backhaus SJ, Metschies G, Zieschang V, Erley J, Mahsa Zamani S, Kowallick JT, Lapinskas T, Pieske B, Lotz J, Kutty S, et al. Head-to-head comparison of cardiovascular MR feature tracking cine versus acquisition-based deformation strain imaging using myocardial tagging and strain encoding. Magn Reson Med. 2021;85(1):357–68.
Li H, Qu Y, Metze P, Sommerfeld F, Just S, Abaei A, Rasche V. Quantification of biventricular myocardial strain using CMR feature tracking: reproducibility in small animals. Biomed Res Int. 2021;2021:8492705.
Weise Valdes E, Barth P, Piran M, Laser KT, Burchert W, Korperich H. Left-ventricular reference myocardial strain assessed by cardiovascular magnetic resonance feature tracking and fSENC-impact of temporal resolution and cardiac muscle mass. Front Cardiovasc Med. 2021;8: 764496.
Obokata M, Nagata Y, Wu VC, Kado Y, Kurabayashi M, Otsuji Y, Takeuchi M. Direct comparison of cardiac magnetic resonance feature tracking and 2D/3D echocardiography speckle tracking for evaluation of global left ventricular strain. Eur Heart J Cardiovasc Imaging. 2016;17(5):525–32.
Andre F, Buss SJ, Friedrich MG. The role of MRI and CT for diagnosis and work-up in suspected ACS. Diagnosis (Berl). 2016;3(4):143–54.
van Everdingen WM, Zweerink A, Nijveldt R, Salden OAE, Meine M, Maass AH, Vernooy K, De Lange FJ, van Rossum AC, Croisille P, et al. Comparison of strain imaging techniques in CRT candidates: CMR tagging, CMR feature tracking and speckle tracking echocardiography. Int J Cardiovasc Imaging. 2018;34(3):443–56.
Pierpaolo P, Rolf S, Manuel BP, Davide C, Dresselaers T, Claus P, Bogaert J. Left ventricular global myocardial strain assessment: Are CMR feature-tracking algorithms useful in the clinical setting? Radiol Med. 2020;125(5):444–50.
Cao JJ, Ngai N, Duncanson L, Cheng J, Gliganic K, Chen Q. A comparison of both DENSE and feature tracking techniques with tagging for the cardiovascular magnetic resonance assessment of myocardial strain. J Cardiovasc Magn Reson. 2018;20(1):26.
Schuster A, Stahnke VC, Unterberg-Buchwald C, Kowallick JT, Lamata P, Steinmetz M, Kutty S, Fasshauer M, Staab W, Sohns JM, et al. Cardiovascular magnetic resonance feature-tracking assessment of myocardial mechanics: intervendor agreement and considerations regarding reproducibility. Clin Radiol. 2015;70(9):989–98.
Reichek N. Myocardial strain: still a long way to go. Circ Cardiovasc Imaging. 2017;10(11):7145.
Amzulescu MS, De Craene M, Langet H, Pasquet A, Vancraeynest D, Pouleur AC, Vanoverschelde JL, Gerber BL. Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. Eur Heart J Cardiovasc Imaging. 2019;20(6):605–19.
Riffel JH, Keller MG, Rost F, Arenja N, Andre F, Aus dem Siepen F, Fritz T, Ehlermann P, Taeger T, Frankenstein L, et al. Left ventricular long axis strain: a new prognosticator in non-ischemic dilated cardiomyopathy? J Cardiovasc Magn Reson. 2016;18(1):36.
Stathogiannis K, Mor-Avi V, Rashedi N, Lang RM, Patel AR. Regional myocardial strain by cardiac magnetic resonance feature tracking for detection of scar in ischemic heart disease. Magn Reson Imaging. 2020;68:190–6.
Potter E, Marwick TH. Assessment of left ventricular function by echocardiography: the case for routinely adding global longitudinal strain to ejection fraction. JACC Cardiovasc Imaging. 2018;11(2 Pt 1):260–74.
Shehata IM, Odell TD, Elhassan A, Urits I, Viswanath O, Kaye AD. Global longitudinal strain: is it time to change the preoperative cardiac assessment of oncology patients? Oncol Ther. 2021;9(1):13–9.
Al-Rashid F, Totzeck M, Saur N, Janosi RA, Lind A, Mahabadi AA, Rassaf T, Mincu RI. Global longitudinal strain is associated with better outcomes in transcatheter aortic valve replacement. BMC Cardiovasc Disord. 2020;20(1):267.
Oikonomou EK, Kokkinidis DG, Kampaktsis PN, Amir EA, Marwick TH, Gupta D, Thavendiranathan P. Assessment of prognostic value of left ventricular global longitudinal strain for early prediction of chemotherapy-induced cardiotoxicity: a systematic review and meta-analysis. JAMA Cardiol. 2019;4(10):1007–18.
Bucius P, Erley J, Tanacli R, Zieschang V, Giusca S, Korosoglou G, Steen H, Stehning C, Pieske B, Pieske-Kraigher E et al. Comparison of feature tracking, fast-SENC, and myocardial tagging for global and segmental left ventricular strain. ESC Heart Fail 2019.
Vo HQ, Marwick TH, Negishi K. MRI-Derived Myocardial Strain Measures in Normal Subjects. JACC Cardiovasc Imaging. 2018;11(2 Pt 1):196–205.
Smiseth OA, Torp H, Opdahl A, Haugaa KH, Urheim S. Myocardial strain imaging: how useful is it in clinical decision making? Eur Heart J. 2016;37(15):1196–207.
Choi EY, Rosen BD, Fernandes VR, Yan RT, Yoneyama K, Donekal S, Opdahl A, Almeida AL, Wu CO, Gomes AS, et al. Prognostic value of myocardial circumferential strain for incident heart failure and cardiovascular events in asymptomatic individuals: the Multi-Ethnic Study of Atherosclerosis. Eur Heart J. 2013;34(30):2354–61.
Cordts K, Seelig D, Lund N, Carrier L, Boger RH, Avanesov M, Tahir E, Schwedhelm E, Patten M. Association of asymmetric dimethylarginine and diastolic dysfunction in patients with hypertrophic cardiomyopathy. Biomolecules. 2019;9(7):277.
Ginelli P, Bella JN. Treatment of diastolic dysfunction in hypertension. Nutr Metab Cardiovasc Dis. 2012;22(8):613–8.
Acknowledgements
We thank our technologists Daniel Helm, Melanie Feiner, Vesna Bentele, Miriam Hess and Leonie Siegmund. A special thanks to M.Sc. Maximilian Pilz who helped with data analysis.
Funding
Open Access funding enabled and organized by Projekt DEAL. DS was partially supported by the German Heart Foundation.
Author information
Authors and Affiliations
Contributions
DS: acquisition, analysis, interpretation of data/writing and editing of draft; JR: conceptualization, analysis, interpretation of data/editing of draft/supervision; JS: interpretation of data; FA: interpretation of data/editing of draft; LW: acquisition and interpretation of data/editing of draft; MO: interpretation of data; NA: acquisition; EH: analysis, interpretation of data/editing of draft; DA: acquisition; HK: resources; EG: resources; NF: resources/editing of draft; MF: conceptualization/analysis, interpretation of data/editing of draft/supervision; All authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
The study was approved by the local ethics committee Ethikkommission Medizinische Fakultät Heidelberg with the case number: S-483/2018. All participants provided informed written consent and all methods were performed in accordance with the relevant guidelines and regulations.
Consent for publication
Not applicable.
Competing interests
MF is advisor, board member and shareholder of Circle Cardiovascular Imaging Inc., Calgary. MF is listed as one of the original patent holders for the United States Patent 15/483,712: MEASURING OXYGENATION CHANGES IN TISSUE AS A MARKER FOR VASCULAR FUNCTION. All other authors do not have any conflicts of interest to declare.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Siry, D., Riffel, J., Salatzki, J. et al. A head-to-head comparison of fast-SENC and feature tracking to LV long axis strain for assessment of myocardial deformation in chest pain patients. BMC Med Imaging 22, 159 (2022). https://doi.org/10.1186/s12880-022-00886-3