Abstract
Background
The World Health Organization (WHO) recommends self-monitoring of blood pressure (SMBP) for hypertension management. In addition, during the COVID-19 response, WHO guidance also recommends SMBP supported by health workers although more evidence is needed on whether SMBP of pregnant individuals with hypertension (gestational hypertension, chronic hypertension, or pre-eclampsia) may assist in early detection of pre-eclampsia, increase end-user autonomy and empowerment, and reduce health system burden. To expand the evidence base for WHO guideline on self-care interventions, we conducted a systematic review of SMBP during pregnancy on maternal and neonatal outcomes.
Methods
We searched for publications that compared SMBP with clinic-based monitoring during antenatal care. We included studies measuring any of the following outcomes: maternal mortality, pre-eclampsia, long-term risk and complications, autonomy, HELLP syndrome, C-section, antenatal hospital admission, adverse pregnancy outcomes, device-related issues, follow-up care with appropriate management, mental health and well-being, social harms, stillbirth or perinatal death, birthweight/size for gestational age, and Apgar score. After abstract screening and full-text review, we extracted data using standardized forms and summarized findings. We also reviewed studies assessing values and preferences as well as costs of SMBP.
Results
We identified 6 studies meeting inclusion criteria for the effectiveness of SMBP, 6 studies on values and preferences, and 1 study on costs. All were from high-income countries. Overall, when comparing SMBP with clinic-monitoring, there was no difference in the risks for most of the outcomes for which data were available, though there was some evidence of increased risk of C-section among pregnant women with chronic hypertension. Most end-users and providers supported SMBP, motivated by ease of use, convenience, self-empowerment and reduced anxiety. One study found SMBP would lower health sector costs.
Conclusion
Limited evidence suggests that SMBP during pregnancy is feasible and acceptable, and generally associated with maternal and neonatal health outcomes similar to clinic-based monitoring. However, more research is needed in resource-limited settings.
Systematic review registration
PROSPERO CRD42021233839.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Background
Hypertensive disorders of pregnancy affect approximately 10% of pregnant individuals globally, and are among the leading causes of pregnancy-related mortality and morbidities for women, adolescent girls, and their newborns, particularly in low and middle-income countries (LMICs) [1,2,3]. Hypertension in pregnancy can also lead to long-term health conditions such as development of chronic hypertension and is associated with pre-eclampsia, which can result in a range of morbidities in newborns, including low birth weight and respiratory distress syndrome [4,5,6]. Early antihypertensive treatment and timely delivery can prevent morbidity and potentially mortality [7]. Improving management of hypertension during pregnancy is thus an essential aspect of quality care for maternal and neonatal health.
Despite many interventions implemented in LMICs to improve maternal and child health over the past several decades, unfavorable health outcomes persist [8, 9]. Increased access to and use of high-quality health care during pregnancy and childbirth remains a priority public health goal, and identifying cost-effective intervention strategies is critical in resource-limited settings [10]. Innovative strategies to improve antenatal care management, including through self-care interventions, have the potential to improve the health outcomes of pregnant individuals and their newborns [11].
Routine antenatal care contacts generally include blood pressure measurement, but blood pressure changes may be missed between contacts. Self-monitoring of blood pressure (SMBP), a strategy in which people take a more active role in their own health care by measuring their own blood pressure [12], may be particularly useful in settings where access to and resources for conventional antenatal care are limited. SMBP has also been referred to as home blood pressure monitoring (HBPM), which focuses on the setting instead of the individual taking the measurement. Among the general hypertensive population, the evidence for the efficacy and feasibility of HBPM has been associated with improved hypertension control compared to clinic-based monitoring [13,14,15], though its impact depends on the specific outcomes that were assessed [16]. A recent review found that SMBP had limited impact on blood pressure control in the general population, unless accompanied by certain co-interventions [17]. However, less is known about SMBP specifically for pregnant individuals and their newborns [18]. Two recent reviews reported mixed benefits of HBPM compared to clinic-based monitoring for multiple maternal and neonatal outcomes among pregnant and postpartum individuals [19, 20], suggesting that home-based monitoring may be as effective as receiving provider-administered care.
We conducted this systematic review in the context of expanding the evidence base of the WHO guidelines on self-care interventions for health [21], which include existing WHO recommendations on self-care interventions during pregnancy, childbirth and post-natal care [22, 23]. SMBP is recommended by WHO for the management of hypertension in appropriate patients where the affordability of the technology has been established [21, 24]. Self-monitoring of hypertensive disorders of pregnancy (including individuals with pregnancy-induced hypertension/gestational hypertension, chronic hypertension, or pre-eclampsia) has been identified as a priority topic for expanding the evidence-base on self-care interventions. Building upon WHO recommendations on the prevention and treatment of pre-eclampsia and eclampsia, this systematic review also included considerations for support to pregnant individuals during health emergencies such as the COVID-19 pandemic [25].
Methods
This review addressed the following question: Should SMBP among individuals with hypertensive disorders of pregnancy be made available in addition to clinic check-ups? We reviewed the extant literature in three areas relevant to this question: (1) effectiveness of the intervention, (2) values and preferences of end-users and providers, and (3) cost information. We included all three of these areas because they are components of the evidence-based process used to inform WHO guideline development [26]. We followed Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) guidelines [27] and registered the protocol on the International Prospective Register of Systematic Reviews (PROSPERO registration number CRD42021233839). Ethical approval was not required for this systematic review, since all data came from published articles.
Effectiveness review inclusion criteria
We designed the effectiveness review according to PICO format as follows:
-
Population: Pregnant individuals with hypertension (gestational hypertension, chronic hypertension, and pre-eclampsia)
-
Intervention: Self-monitoring of blood pressure (either by the pregnant individual or by another layperson, such as a family member)
-
Comparison: Clinic blood pressure monitoring by health care providers during antenatal care (ANC) contacts only
-
Outcomes:
-
Maternal outcomes:
-
1.
Maternal mortality or near-miss
-
2.
Eclampsia or pre-eclampsia (for those without pre-eclampsia prior to entering the study)
-
3.
Long-term risk or complications: stroke, cardiovascular outcomes, chronic kidney (renal) disease, or chronic hypertension
-
4.
Autonomy (measured by self-efficacy, self-determination, empowerment)
-
5.
HELLP syndrome
-
6.
Cesarean section
-
7.
Antenatal hospital admission
-
8.
Adverse pregnancy outcomes: spontaneous abortion, premature rupture of membranes, placental abruption
-
9.
Device-related issues (e.g. test failure, problems with manufacturing, packaging, labelling, or instructions for use)
-
10.
Follow-up care with appropriate management
-
11.
Mental health and well-being (e.g. anxiety, stress, self-harm)
-
12.
Social harms: stigma, discrimination, intimate partner violence
-
1.
-
Fetal/neonatal outcomes:
-
1.
Stillbirth or perinatal death
-
2.
Birthweight and size for gestational age
-
3.
Apgar score
-
1.
-
To be included in the review, an article must have: (1) had a study design that compared SMBP among pregnant individuals with hypertension at home or outside the clinic setting to only during ANC by a health care provider, including randomized controlled trials, non-randomized controlled trials, and comparative observational studies (including prospective controlled cohort studies, retrospective controlled cohort studies, cross-sectional studies, controlled before-after studies and interrupted time series) that compare individuals who received the intervention to those who did not, (2) measured one or more of the above outcomes, and (3) been published in a peer-reviewed journal.
There are many different categories and definitions of hypertensive disorders in pregnancy, which vary across national medical societies and organizations [28]. For the purposes of this review, we included any study that presented data for pregnant individuals with hypertension, no matter how it was defined; however, we carefully reviewed definitions used to ensure comparability when comparing results across studies.
We defined SMBP as monitoring of blood pressure either by the pregnant individual or by another layperson, such as a family member, in which the measurement is initiated by the lay user (whether or not the sphygmanometer was automatic) and the blood pressure data is recorded and/or reviewable by the lay user prior to or at the same time as the provider (whether on paper or electronically). We excluded ambulatory blood pressure monitoring [29], wherein users typically wear a monitor on their upper arms for 24 hours of measurement, and telehealth [30], where end-users may not have the ability to independently record or review their blood pressure measurements without concurrent interaction with a health provider through a mobile or online app.
We did not restrict study inclusion on the basis of language or intervention location. Articles in English, French, Spanish, and Chinese were coded directly; articles in other languages were translated.
Search strategy and screening
We searched four electronic databases (PubMed, CINAHL, LILACS and EMBASE) through the search date of November 9, 2020 using the following search string (designed for PubMed and adapted for each database):
(“blood pressure” [mesh] OR hypertension [mesh] OR “Blood Pressure Monitoring, Ambulatory” [mesh] OR hypertension [tiab] OR hypertensive [tiab] OR PIH [tiab] or “blood pressure” [tiab] OR pre-eclampsia [tiab] or bp [tiab])
AND
(pregnancy [Mesh] OR pregnancy [tiab] OR pregnant [tiab] OR peri-natal [tiab] OR perinatal [tiab] OR antenatal [tiab] OR maternal [tiab])
AND
(“self care”[Mesh] OR “self-care”[tiab] OR “self-monitoring”[tiab] OR “self-management”[tiab] OR “self-monitor”[tiab] OR “self-manage”[tiab] OR “self-monitored”[tiab] OR “self-managed”[tiab] OR “self-evaluation”[tiab] OR “self-test”[tiab] OR “self-testing”[tiab] OR “home”[tiab] OR “pharmacy”[tiab])
We further searched for ongoing randomized controlled trials (RCTs) through clinicaltrials.gov, the WHO International Clinical Trials Registry Platform, the Pan African Clinical Trials Registry, and the Australian New Zealand Clinical Trials Registry. In addition, we searched the Cochrane Database of Systematic Reviews for related reviews. Secondary reference searching was also conducted on all studies included in the review and relevant reviews. Finally, selected experts in the field were contacted to identify additional articles not identified through other search methods.
Titles, abstracts, citation information, and descriptor terms of citations identified through the search strategy were screened by a member of the study staff. Full-text articles were obtained of all selected abstracts, and two independent reviewers assessed all full-text articles for eligibility to determine final study selection. Differences were resolved through consensus.
Data management and analysis
Two reviewers independently abstracted data using standardized forms. Differences in data extraction were resolved through consensus and referral to a senior study team member from WHO as necessary. We gathered the following information from each article: study identification (authors, type of citation, year of publication), study description (study objectives, location, population characteristics, type and definition of hypertension, type of blood pressure apparatus, individual taking the blood pressure at home, description of any additional intervention components such as any education, training, support provided, study design, sample size, follow-up periods, and loss to follow-up), and outcomes (analytic approach, outcome measures, comparison groups, effect sizes, confidence intervals, significance levels, conclusions, study limitations).
For RCTs, risk of bias was assessed using the Cochrane Collaboration’s tool for assessing risk of bias [31]. For studies that were not randomized trials but were comparative, study rigor was assessed using the Evidence Project 8-item checklist for intervention evaluations [32].
Data were analyzed according to coding categories and outcomes. Where there were multiple studies reporting the same outcome, meta-analysis was conducted using random-effects models to combine risk ratios (RRs) or mean differences (MDs) with the program Comprehensive Meta-Analysis (CMA). For each PICO outcome category, data were summarized in a GRADE Evidence Profile table using GRADEPro, prioritizing RCT data over observational data where available.
Where possible, we planned to stratify all analyses by the following categories/subgroups: form of hypertension during pregnancy (gestational hypertension, chronic hypertension, and pre-eclampsia), prior risk of hypertension, age (adolescent girls and young adults of ages 10–14, 15–19, and 15–24, and women of ages 25+), type of blood pressure (BP) monitor, vulnerabilities (i.e. obesity, poverty, disability, rural/urban, literacy/educational level), and high-income versus low or middle-income countries.
Complementary reviews
We conducted complementary reviews to examine the values and preferences of end-users and providers and costs related to SMBP. We used the same search strategy to identify studies to be included in these reviews. These studies could have been qualitative or quantitative in nature, but had to present primary data collection; think pieces and review articles were not included. We summarized this literature qualitatively and organized findings by study design and methodology, location, and population.
Values and preferences review
We focused on studies examining the values and preferences of pregnant individuals who expressed willingness to self-manage their blood pressure (including non-hypertensive individuals) and were able to accurately record and report blood pressure measurements to their healthcare provider. Given the growing use of remote patient monitoring and web/app-based health services [33], we included studies involving telehealth. We also included studies examining the values and preferences of healthcare providers, including their willingness to trust their clients. We considered issues related to age of availability, informed decision-making, coercion and seeking redress in this section.
Cost review
We included studies in this review if they presented primary data comparing costing, cost-effectiveness, cost-utility, or cost-benefit of the intervention and comparison listed in the PICO question above, or if they presented cost-effectiveness of the intervention as it related to the PICO outcomes listed above. This included both cost to the health system and cost to the end-user. Cost literature was classified into four categories: health sector costs, other sector costs, patient/family costs, and productivity impacts.
Patient and public involvement
Feedback on the review protocol and analysis was received from the WHO patient safety working group. Patients were involved in a global survey of values and preferences conducted to inform the WHO guideline on self-care interventions and play a role in the overall recommendation informed by this review.
Results
Our database search yielded 2598 records, and we identified another 34 through hand- and secondary searching (Fig. 1). Of the 1794 unique records, we retained 91 for full-text review. Ultimately, we included 6 studies in the effectiveness review [34,35,36,37,38,39], 7 studies (reported in 8 articles) in the values and preferences review [40,41,42,43,44,45,46,47,48,49], and 1 study in the cost review [50].
Effectiveness review
Overall, 6 studies met the inclusion criteria for the effectiveness review [34,35,36,37,38,39]. Table 1 presents descriptive data for the 1 RCT and 5 observational studies. To assess the highest-certainty evidence for each PICO outcome category, we included RCT data in the GRADE Evidence Profile (Table 2) when available, and where RCT data were not available, we included data from observational studies. Given the small number of studies presenting outcome data, no further stratifications from our a priori list were possible.
One small feasibility RCT among 154 pregnant women with chronic or gestational hypertension without pre-eclampsia at four health centers in the UK (OPTIMUM-BP) compared SMBP with usual care from December 2015 to December 2017 [37]. This study was classified as low risk of bias for all outcomes; though participant and provider blinding was not possible given the nature of the intervention (potential detection bias), the clinical outcomes measured by this trial were unlikely to have been affected by lack of blinding. This RCT reported on several maternal and neonatal outcomes of interest: pre-eclampsia, c-section, antenatal hospital admission, stillbirth or perinatal death, and birthweight/size for gestational age.
Two observational studies at the same hospital in the UK, one case-control among pregnant women with gestational hypertension [38] and one prospective cohort among pregnant women with chronic hypertension, gestational hypertension, or high risk of developing pre-eclampsia [36], examined maternal adverse events, comparing between SBMP and routine ANC. These studies were also judged to have low risk of bias. Three additional observational studies were not included in the GRADE Evidence Profile because they reported the same outcomes as the RCT [34, 35, 39].
Eclampsia or pre-eclampsia
Comparing between individuals who self-monitored blood pressure and those who had their BP measured during routine ANC, the single RCT found no statistically significant difference in pre-eclampsia rate among pregnant individuals with either chronic (RR: 2.15, 95% confidence interval (CI): 0.89–5.17) or gestational (RR: 0.84, 95% CI: 0.42–1.69) hypertension [37]. This was graded as low-certainty evidence because of the small sample size and because the 95% confidence interval for relative risk crossed 1 and included the potential for both appreciable benefit or appreciable harm.
Cesarean section
The RCT found that SMBP was associated with higher C-section rates among pregnant individuals with chronic hypertension compared to clinic monitoring (RR: 2.01, 95% CI: 1.22–3.30, moderate certainty – downgraded for very small sample size), but there was no difference between SMBP and clinic monitoring among participants with gestational hypertension (RR: 0.86, 95% CI: 0.55–1.34) [37]. This was graded as low-certainty evidence for the same reasons as the previous outcome.
Antenatal hospital admission
The RCT found no difference between SMBP and clinic monitoring on antenatal hospital admissions, for pregnant individuals with either chronic or gestational hypertension. This was considered low-to-moderate certainty evidence because of the very small sample size and very rare or non-existent events (in some groups, there were no records of admission to the hospital inpatient intensive therapy unit) [37].
Adverse pregnancy outcomes
Two observational studies found no difference between SMBP and clinic monitoring on maternal morbidity, as measured with composite maternal adverse outcomes among pregnant individuals with gestational hypertension (RR: 0.79, 95% CI: 0.05–12.34) [36] or among pregnant individuals with chronic hypertension, gestational hypertension, or high risk of developing preeclampsia (RR: 0.27, 95% CI: 0.02–2.90) [38]. This was graded as very low certainty evidence because the number of events in both groups was very small (very rare events, despite reporting a composite outcome of many types of maternal adverse events combined) and because of the very small sample size.
Stillbirth or perinatal death
The RCT showed no difference between SMBP and clinic monitoring of BP on stillbirth or perinatal death. This was considered low-to-moderate certainty evidence because of the very small sample size and very rare (or non-existent) events in one or both arms [37].
Birthweight / size for gestational age
The RCT showed that SMBP was associated with lower birthweight (MD: -300.2, 95% CI: − 690.7-90.2) and a higher rate of infants being born small for gestational age (RR: 4.53, 95% CI: 0.59–34.48) among pregnant individuals with chronic hypertension compared with clinic monitoring, though these associations were not statistically significant [37]. The associations were similarly non-significant for those with gestational hypertension (MD in birthweight: 54.2, 95% CI: -341.7-450; RR for being born small for gestational age: 1.01, 95% CI: 0.35–2.93) [37]. This was graded as low-certainty evidence for the same reasons as the pre-eclampsia outcome.
Other outcomes of interest
No quantitative comparative data were identified from either RCTs or observational studies related to maternal mortality or near-miss; long-term term risk or complications (e.g. stroke, cardiovascular outcomes, chronic kidney (renal) disease, or chronic hypertension); autonomy (measured by self-efficacy, self-determination, empowerment); HELLP syndrome; device-related issues; follow-up care with appropriate management; mental health and wellbeing (e.g. anxiety, stress, self-harm); social harms (e.g. stigma, discrimination, intimate partner violence); or Apgar score.
Values and preferences review
Seven studies reported in 8 articles [40,41,42,43,44,45,46,47] conducted in North America, Europe, and Oceania (all high-income countries) provided values and preferences data on SMBP for pregnant individuals with hypertensive disorders (Table 3). Two of these studies also reported data on providers’ perspectives [40, 46]. In terms of study design, 4 were quantitative studies, 3 were qualitative, and 1 was mixed methods; all employed non-probability facility-based sampling methods for participant recruitment.
Overall, most end-users found SMBP highly satisfactory or acceptable. In fact, when end-users were specifically asked whether they would recommend SMBP to others in the SAFE@HOME study, almost all (especially multiparous women) reported that they would [42, 47]. For end-users, reasons for liking SMBP included the technical ease of use [43] and convenience of the device while conducting daily activities [41, 42]. There was some variation in end-users’ perception of ease of use; one study found that a certain brand and model of the device used for SMBP was perceived to be uncomfortable and noisy [45].
Reasons for liking SMBP went beyond the technical qualities of the self-monitoring device. For many end-users, SMBP reduced anxiety about their health during pregnancy; those who reported history of preeclampsia felt that self-monitoring allowed them to have more accurate and up-to-date information on their own health [41]. Women also reported feeling reassured when the SMBP device confirmed their BP status as “normal” [42]. In addition, SMBP was seen as helpful for encouraging healthy pregnancy-related behaviors [43]. End-users widely agreed that SMBP was beneficial and conducive to decreased stress during pregnancy, and they appreciated the reduction in frequency of care visits [42, 44].
End-users also noted SMBP for its role in facilitating self-empowerment. The practice of SMBP created the impression that they were taking a greater role in self-care as related to blood pressure, pregnancy, and health [42] through taking initiative in using the device [45], and the resulting sense of empowerment helped to alleviate anxiety [44]. Despite SMBP reducing the number of care visits, many patients whose SMBP devices enabled them to communicate with their providers (i.e. through apps for remote monitoring and telehealth) felt even more connected to their care team [43]. Generally, women agreed that they would continue to use SMBP themselves and recommend others to do the same [42, 47].
Two studies in the Netherlands and the UK reported values and preferences surrounding SBMP from the provider perspective [40, 41, 46]. Healthcare providers generally approved of SMBP, though with several concerns. The most frequently mentioned advantages of this strategy were improved patient comfort and reductions in emotional burden of admission, as well as better rest/less stress, increased patient autonomy, satisfaction, and safety, and decreased over-medicalization during pregnancy. However, clinicians stressed that the practice may be vulnerable to inaccurate and unreliable BP measurements, whether related to technical issues or inability to follow instructions/conduct monitoring at home, leading to a false sense of security, and that end-users should be educated on how to responsibly react to abnormal BP. Some expressed worries about device security issues. Moreover, clinicians opined that SMBP may not be popular for care teams since self-monitoring would shift the responsibility for healthcare to individuals, which may lead to delays in providing care during emergencies or acute problems, curtailed direct communication/patient assessments with the consulting gynecologist, or other cost/reimbursement issues.
Cost review
One study in the UK assessed the cost-minimization of HBPM (likely performed by the end-user at home, but not specified by the study authors) among hypertensive pregnant women using an automated BP machine linked to paper notes or smartphone app [50]. In terms of direct costs for the health system, authors found a mean cost savings per week per patient using HBPM compared with traditional BP monitoring at maternity outpatient hospital visits was £200.69, which increased to £286.53 when using a smartphone application instead of a diary to record the blood pressure readings and clinical symptoms, and receive feedbacks. When using process modeling for the health system, they predicted a weekly savings of £98.32–£245.80 per patient, depending on the number of outpatient visits (visit cost included: midwife, doctor, blood tests, and fetal cardiotocography). In a second modeling scenario, if hospital admission were needed to initiate treatment, costs were similar for HBPM and traditional monitoring, but these incidents were anticipated and modeled to be infrequent occurrences, leading to significant cost savings.
Discussion
Compared with clinic BP monitoring, SMBP was associated with twice the rate of C-section among individuals with chronic hypertension but no difference in C-section among individuals with gestational hypertension. However, the overall certainty of this evidence is low, due to small sample size, few events, and wide CIs, so it remains unclear whether SMBP changes the risk of C-section compared with BP monitoring during routine ANC visits. No other associations between SMBP and outcomes of interest were observed for pregnant individuals with any type of hypertension (chronic hypertension, gestational hypertension, or high risk of pre-eclampsia). Most end-users found SMBP highly satisfactory or acceptable and cited various factors including the device’s ease of use, convenience, and ability to help them feel empowered as reasons for liking self-monitoring. SMBP was also found to incur significant cost savings compared to usual care, due in part to fewer clinic visits.
Insufficient research on SMBP among pregnant individuals with hypertension has been conducted in LMICs. All our included studies were conducted in high-income countries. However, studying the health implications of SMBP for pregnant women with hypertensive disorders is of particular importance in LMICs. Pre-eclampsia is the world’s second leading cause of direct maternal death [51], and management of hypertension in LMICs could be improved [52]. In resource-limited settings, including in humanitarian crises or during pandemics like COVID-19, workable strategies for prevention, maintenance, and early intervention are needed for pregnant individuals [51].
A 2020 Cochrane review examining settings and techniques for monitoring blood pressure during pregnancy [18] identified the same feasibility RCT [37] we did. Another review found that HBPM significantly reduced the odds of preeclampsia and prenatal hospital admission relative to clinic-based monitoring for pregnant women [20]. The differences between these reviews’ findings and ours are likely due to differences in the characteristics of the study populations: our review was restricted to pregnant women with hypertension, while these reviews included all pregnant women.
Multiple strategies for blood pressure monitoring exist, including ambulatory blood pressure monitoring (ABPM) or recording a person’s blood pressure at different intervals over a 24-hour period [29]. A recent RCT found no statistically significantly difference in blood pressure measurements between 24-hour ABPM and clinic-monitoring [53], suggesting that the former may be just as effective as the latter. However, this model of blood pressure monitoring may be more feasible in high-income countries, given the infrastructure needed to support remote/mobile monitoring from home, such as internet access or publicly accessible Bluetooth and Wireless connections [54]. A recent review found ABPM utilization in just 36% of LMICs [55]. Potential reasons for low uptake include rejection by end-users because of the device disrupting sleep, higher initial cost versus other modes of SMBP like automated sphygmomanometers, end-users having to overcome the burden of transporting the devices, and the lack of formal training for clinicians with ABPM in many settings [55].
A viable alternative is SMBP, with or without the support of a mobile health (mHealth) or telehealth component. Hodgkinson et al. recently published a review on the optimal SMBP schedule [56]. mHealth is already widely used in the high-income countries (e.g. smartphone applications) and is gaining pace in LMICs (e.g. SMS) for its utility in managing a variety of conditions, providing clinical support to patients, and easing health system burden by preventing unnecessary clinic visits [30, 57]. With high and growing mobile phone ownership globally, mHealth-based SMBP has the potential to be an effective, acceptable, and cost-saving tool for monitoring hypertension [58, 59] and improving obstetric outcomes [60].
The growth of the digital health field – and technology’s role in health – may provide opportunities to expand the use of certain SMBP approaches, especially in low-resource settings. WHO has made progress in classifying the various types of digital health interventions, one of which is personal health tracking including self-monitoring of health or diagnostic data by clients. While some innovative technologies may be more suitable for low-resource settings [61], future work should continue to investigate which digital technologies can facilitate accurate and more consistent BP measurements in LMICs. In an effort to build capacity and support to countries to use digital technologies for the delivery of evidence-based healthcare and health practices, WHO has started producing guidelines to facilitate the implementation of WHO guidelines and recommendations in the digital age [62].
Furthermore, there are several types of devices that can be used to measure BP. These devices can be manual/analogue or automated/electric, and each type of device presents a range of benefits and challenges for health workers as well as lay people. In general, manual devices are not recommended and are being phased out because of environmental concerns, need for frequent calibration to maintain measurement accuracy, and inaccurate BP measurements. Instead, automated devices are preferred and recommended, as they may produce more accurate and consistent measurements [29]. In all settings, good-quality, validated devices need to be available to provide accurate BP measurements. However, low-resource settings may face particular challenges with acquiring, properly maintaining and calibrating these devices, and ensuring their appropriate use.
This review has a number of strengths. We conducted a comprehensive search across multiple databases as well as a hand search and secondary search. We also rigorously assessed the methodological quality of studies and examined not only the effectiveness of SMBP compared to monitoring during ANC but also its acceptance by pregnant individuals and providers and costing. Through this process, we found that SMBP is generally not associated with poorer maternal or neonatal health outcomes, that pregnant individuals and providers generally supported use of SMBP, and that SMBP could be cost-saving for a health system.
This review also had several limitations. First, our definition of SMBP was very specific. We excluded ambulatory monitoring and remote/telemonitoring from our effectiveness review because these methods put the primary responsibility for health monitoring on the provider, bypassing the person-centered focus of self-care. Second, the evidence base for our effectiveness, values and preferences, and cost reviews was limited: small sample sizes precluded our ability to reveal any effect on SMBP on maternal and perinatal outcomes of interest like stillbirth, and our findings came exclusively from high-income settings. Future research should examine the ramifications of implementing SMBP in resource-limited settings. Included studies did not provide details on the health literacy assessment of participants, though a few mentioned educational level or general language competency, so further research could investigate the feasibility, acceptability, and impact of this strategy for end-users of varying health literacy levels. Of note, the included studies all occurred prior to significant changes in prenatal care delivery during the COVID-19 pandemic. It is possible that in the context of increased familiarity with both remote monitoring and self-management of chronic disease [63], providers and patients would have different attitudes, knowledge and potential use cases for SMBP during pregnancy. Finally, the included studies do not specifically address potential benefits of SMBP postpartum. A current focus of postpartum quality improvement efforts in the US includes improved ascertainment and treatment of hypertension after delivery [64]. We were unable to assess the impact of SMBP on outcomes after the delivery such as morbidity, hospital readmission, and unplanned care utilization.
Using the evidence from this review and discussion among the guideline development group, the WHO Consolidated guideline on self-care interventions for health and well-being published in 2021 included the following recommendation: “WHO suggests making the self-monitoring of blood pressure during pregnancy available as an additional option to clinic blood pressure monitoring by health workers during antenatal contacts only, for individuals with hypertensive disorders of pregnancy. (Conditional recommendation; very low certainty evidence)” [65].
Conclusion
SMBP is commonly available, especially in high-income settings, and generally accepted by end-users and health workers, suggesting its feasibility as an additional option for monitoring blood pressure during the antenatal period for pregnant individuals with hypertension. This review of the existing limited literature suggests that SMBP can be a cost-effective approach to expanding health services to the end-user with similar outcomes as receiving typical care from ANC, but more research is needed in low-resource settings.
Availability of data and materials
Extracted data are available on request to the corresponding author. No additional data beyond what is presented in this article.
Abbreviations
- SMBP:
-
Self-monitoring of blood pressure
- WHO:
-
World Health Organization
- LMIC:
-
Low and middle-income country
- HBPM:
-
Home blood pressure monitoring
- PRISMA:
-
Preferred Reporting Items for Systematic review and Meta-Analysis
- RCT:
-
Randomized controlled trial
- RR:
-
Risk ratios
- MD:
-
Mean difference
- CMA:
-
Comprehensive Meta-Analysis
- BP:
-
Blood pressure
- SMART:
-
Standards-based, machine-readable, adaptive, requirements-based, and testable
References
Abalos E, Cuesta C, Grosso AL, Chou D, Say L. Global and regional estimates of preeclampsia and eclampsia: a systematic review. Eur J Obstet Gynecol Reprod Biol. 2013;170(1):1–7.
Duley L. The global impact of pre-eclampsia and eclampsia. Semin Perinatol. 2009;33(3):130–7.
Steegers EA, von Dadelszen P, Duvekot JJ, Pijnenborg R. Pre-eclampsia. Lancet (London, England). 2010;376(9741):631–44.
Wen Y-H, Yang H-I, Chou H-C, Chen C-Y, Hsieh W-S, Tsou K-I, et al. Taiwan Premature Infant Developmental Collaborative Study G: Association of Maternal Preeclampsia with Neonatal Respiratory Distress Syndrome in Very-Low-Birth-Weight Infants. Sci Rep. 2019;9(1):13212.
Bramham K, Parnell B, Nelson-Piercy C, Seed PT, Poston L, Chappell LC. Chronic hypertension and pregnancy outcomes: systematic review and meta-analysis. BMJ. 2014;348:g2301.
Seely EW, Ecker J. Chronic hypertension in pregnancy. Circulation. 2014;129(11):1254–61.
Webster LM, Conti-Ramsden F, Seed PT, Webb AJ, Nelson-Piercy C, Chappell LC. Impact of antihypertensive treatment on maternal and perinatal outcomes in pregnancy complicated by chronic hypertension: a systematic review and meta-analysis. J Am Heart Assoc. 2017;6(5):e005526.
Lassi ZS, Middleton PF, Bhutta ZA, Crowther C. Strategies for improving health care seeking for maternal and newborn illnesses in low- and middle-income countries: a systematic review and meta-analysis. Glob Health Action. 2016;9:31408.
Nyamtema AS, Urassa DP, van Roosmalen J. Maternal health interventions in resource limited countries: a systematic review of packages, impacts and factors for change. BMC Pregnancy Childbirth. 2011;11(1):30.
Mangham-Jefferies L, Pitt C, Cousens S, Mills A, Schellenberg J. Cost-effectiveness of strategies to improve the utilization and provision of maternal and newborn health care in low-income and lower-middle-income countries: a systematic review. BMC Pregnancy Childbirth. 2014;14:243.
Kolivand M, Rahimi MA, Keramat A, Shariati M, Emamian MH. Effect of a new self-care guide package on maternal and neonatal outcomes in gestational diabetes: A randomized control trial. J Diabetes. 2019;11(2):139–47.
Uhlig K, Patel K, Ip S, Kitsios GD, Balk EM. Self-Measured Blood Pressure Monitoring in the Management of Hypertension. Ann Intern Med. 2013;159(3):185–94.
Agarwal R, Bills JE, Hecht TJ, Light RP. Role of home blood pressure monitoring in overcoming therapeutic inertia and improving hypertension control: a systematic review and meta-analysis. Hypertension (Dallas, Tex : 1979). 2011;57(1):29–38.
Verberk WJ, Kroon AA, Kessels AG, de Leeuw PW. Home blood pressure measurement: a systematic review. J Am Coll Cardiol. 2005;46(5):743–51.
Stergiou GS, Bliziotis IA. Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review. Am J Hypertens. 2011;24(2):123–34.
Ogedegbe G, Schoenthaler A. A systematic review of the effects of home blood pressure monitoring on medication adherence. J Clin Hypertension. 2006;8(3):174–80.
Tucker KL, Sheppard JP, Stevens R, Bosworth HB, Bove A, Bray EP, et al. Self-monitoring of blood pressure in hypertension: A systematic review and individual patient data meta-analysis. PLoS Med. 2017;14(9):e1002389.
Ashworth DC, Maule SP, Stewart F, Nathan HL, Shennan AH, Chappell LC. Setting and techniques for monitoring blood pressure during pregnancy. Cochrane Database Syst Rev. 2020;8:Cd012739.
Tucker KL, Bankhead C, Hodgkinson J, Roberts N, Stevens R, Heneghan C, et al. How do home and clinic blood pressure readings compare in pregnancy? Hypertension (Dallas, Tex : 1979). 2018;72(3):686–94.
Kalafat E, Benlioglu C, Thilaganathan B, Khalil A. Home blood pressure monitoring in the antenatal and postpartum period: A systematic review meta-analysis. Pregnancy Hypertension. 2020;19:44–51.
WHO. WHO consolidated guideline on self-care interventions for health: sexual and reproductive health and rights. Geneva: World Health Organization; 2019.
WHO. WHO recommendations for prevention and treatment of pre-eclampsia and eclampsia. Geneva: World Health Organization; 2011.
WHO. WHO recommendations on antenatal care for a positive pregnancy experience. Geneva: World Health Organization; 2017.
WHO. WHO package of essential noncommunicable (PEN) disease interventions for primary health care. Geneva: World Health Organization; 2020.
WHO. Maintaining essential health services: operational guidance for the COVID-19 context interim guidance. Geneva: World Health Organization; 2020.
WHO. WHO handbook for guideline development, 2nd ed. Geneva: World Health Organization; 2014.
Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.
Braunthal S, Brateanu A. Hypertension in pregnancy: Pathophysiology and treatment. SAGE Open Med. 2019;7:2050312119843700.
WHO. WHO technical specifications for automated non-invasive blood pressure measuring devices with cuff. Geneva: World Health Organization; 2020.
Abaza H, Marschollek M. mHealth Application Areas and Technology Combinations*. A Comparison of Literature from High and Low/Middle Income Countries. Methods Inf Med. 2017;56(7):e105–22.
Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane Handbook for Systematic Reviews of Interventions. 2nd Edition. Chichester (UK): Wiley; 2019.
Kennedy CE, Fonner VA, Armstrong KA, Denison JA, Yeh PT, O’Reilly KR, et al. The Evidence Project risk of bias tool: assessing study rigor for both randomized and non-randomized intervention studies. Syst Rev. 2019;8(1):3.
Vegesna A, Tran M, Angelaccio M, Arcona S. Remote patient monitoring via non-invasive digital technologies: a systematic review. Telemed J E Health. 2017;23(1):3–17.
Fukushima T, Berumen M, Vargas N, Zadeh N, Hon EH. The effects of cardiovascular dynamics monitoring in the outpatient management of pregnancy hypertension. Am J Obstet Gynecol. 2002;186(6):1207–13 discussion 1213-1205.
Iwama N, Metoki H, Ohkubo T, Ishikuro M, Obara T, Kikuya M, et al. Maternal clinic and home blood pressure measurements during pregnancy and infant birth weight: The BOSHI study. Hypertens Res. 2016;39(3):151–7.
Kalafat E, Leslie K, Bhide A, Thilaganathan B, Khalil A. Pregnancy outcomes following home blood pressure monitoring in gestational hypertension. Pregnancy Hypertens. 2019;18:14–20.
Pealing LM, Tucker KL, Mackillop LH, Crawford C, Wilson H, Nickless A, et al. A randomised controlled trial of blood pressure self-monitoring in the management of hypertensive pregnancy. OPTIMUM-BP: A feasibility trial. Pregnancy Hypertens. 2019;18:141–9.
Perry H, Sheehan E, Thilaganathan B, Khalil A. Home blood-pressure monitoring in a hypertensive pregnant population. Ultrasound Obstetr Gynecol. 2018;51(4):524–30.
Rayburn WF, Piehl EJ, Compton AA. Clinical significance of home blood pressure monitoring during pregnancy. Clinical Exp Hypertension Part B. 1985;4(1):63–73.
Hinton L, Hodgkinson J, Tucker KL, Rozmovits L, Chappell L, Greenfield S, et al. Exploring the potential for introducing home monitoring of blood pressure during pregnancy into maternity care: current views and experiences of staff—a qualitative study. BMJ Open. 2020;10(12):e037874.
Hinton L, Tucker KL, Greenfield SM, Hodgkinson JA, Mackillop L, McCourt C, et al. Blood pressure self-monitoring in pregnancy (BuMP) feasibility study; a qualitative analysis of women's experiences of self-monitoring. BMC Pregnancy Childbirth. 2017;17(1):427.
Jongsma KR, van den Heuvel JFM, Rake J, Bredenoord AL, Bekker MN. User Experiences With and Recommendations for Mobile Health Technology for Hypertensive Disorders of Pregnancy: Mixed Methods Study. JMIR mHealth uHealth. 2020;8(8):e17271.
Marko KI, Krapf JM, Meltzer AC, Oh J, Ganju N, Martinez AG, et al. Testing the Feasibility of Remote Patient Monitoring in Prenatal Care Using a Mobile App and Connected Devices: A Prospective Observational Trial. JMIR Res Protocols. 2016;5(4):e200.
Sheehan E, Khalil A, Kay L. Using a smartphone app to identify signs of pre-eclampsia and/or worsening blood pressure. Br J Midwifery. 2019;27(2):92–9.
Taylor RS, Freeman L, North RA. Evaluation of ambulatory and self-initiated blood pressure monitors by pregnant and postpartum women. Hypertension Pregnancy. 2001;20(1):25–33.
van den Heuvel JFM, Ayubi S, Franx A, Bekker MN. Home-Based Monitoring and Telemonitoring of Complicated Pregnancies: Nationwide Cross-Sectional Survey of Current Practice in the Netherlands. JMIR mHealth uHealth. 2020;8(10):e18966.
van den Heuvel JFM, Lely AT, Huisman JJ, Trappenburg JCA, Franx A, Bekker MN. SAFE@HOME: Digital health platform facilitating a new care path for women at increased risk of preeclampsia - A case-control study. Pregnancy Hypertension. 2020;22:30–6.
Black KD. Stress, symptoms, self-monitoring confidence, well-being, and social support in the progression of preeclampsia/gestational hypertension. J Obstetr Gynecol Neonatal Nurs. 2007;36(5):419–29.
Lan PG, Hyett J, Gillin AG. Home blood pressure measurement in women with pregnancy-related hypertensive disorders. Pregnancy Hypertens. 2017;10:213–9.
Xydopoulos G, Perry H, Sheehan E, Thilaganathan B, Fordham R, Khalil A. Home blood-pressure monitoring in a hypertensive pregnant population: cost-minimization study. Ultrasound Obstetr Gynecol. 2019;53(4):496–502.
Firoz T, Sanghvi H, Merialdi M, von Dadelszen P. Pre-eclampsia in low and middle income countries. Best Pract Res Clin Obstetr Gynaecol. 2011;25(4):537–48.
Geldsetzer P, Manne-Goehler J, Marcus M-E, Ebert C, Zhumadilov Z, Wesseh CS, et al. The state of hypertension care in 44 low-income and middle-income countries: a cross-sectional study of nationally representative individual-level data from 1·1 million adults. Lancet. 2019;394(10199):652–62.
Rhodes CA, Beevers DG, Churchill D. A randomized trial of ambulatory blood pressure monitoring versus clinical blood pressure measurement in the management of hypertension in pregnancy. A feasibility study. Pregnancy Hypertension. 2018;11:142–4.
Piette JD, Datwani H, Gaudioso S, Foster SM, Westphal J, Perry W, et al. Hypertension management using mobile technology and home blood pressure monitoring: results of a randomized trial in two low/middle-income countries. Telemedicine J E-Health. 2012;18(8):613–20.
Abdalla M. Ambulatory Blood Pressure Monitoring: A Complementary Strategy for Hypertension Diagnosis and Management in Low-Income and Middle-Income Countries. Cardiol Clin. 2017;35(1):117–24.
Hodgkinson JA, Stevens R, Grant S, Mant J, Bray EP, Hobbs FDR, et al. Schedules for Self-monitoring Blood Pressure: A Systematic Review. Am J Hypertens. 2019;32(4):350–64.
Hurt K, Walker RJ, Campbell JA, Egede LE. mHealth Interventions in Low and Middle-Income Countries: A Systematic Review. Global J Health Sci. 2016;8(9):54429.
Vedanthan R, Bernabe-Ortiz A, Herasme OI, Joshi R, Lopez-Jaramillo P, Thrift AG, et al. Innovative Approaches to Hypertension Control in Low- and Middle-Income Countries. Cardiol Clin. 2017;35(1):99–115.
Iribarren SJ, Cato K, Falzon L, Stone PW. What is the economic evidence for mHealth? A systematic review of economic evaluations of mHealth solutions. PLoS One. 2017;12(2):e0170581.
Lanssens D, Vonck S, Storms V, Thijs IM, Grieten L, Gyselaers W. The impact of a remote monitoring program on the prenatal follow-up of women with gestational hypertensive disorders. Eur J Obstetr Gynecol Reprod Biol. 2018;223:72–8.
WHO. WHO compendium of innovative health technologies for low-resource settings. Geneva, World Health Organization; 2017. Available at: https://www.who.int/publications/i/item/9789240032507.
Mehl G, Tunçalp Ö, Ratanaprayul N, Tamrat T, Barreix M, Lowrance D, et al. WHO SMART guidelines: optimising country-level use of guideline recommendations in the digital age. Lancet Digital Health. 2021;3(4):e213–6.
Peahl AF, Smith RD, Moniz MH. Prenatal care redesign: creating flexible maternity care models through virtual care. Am J Obstet Gynecol. 2020;223(3):389.e381–10.
Hauspurg A, Lemon LS, Quinn BA, Binstock A, Larkin J, Beigi RH, et al. A Postpartum Remote Hypertension Monitoring Protocol Implemented at the Hospital Level. Obstet Gynecol. 2019;134(4):685–91.
WHO. WHO consolidated guideline on self-care interventions for health and wellbeing. Geneva: World Health Organization; 2021. Available at: https://app.magicapp.org/#/guideline/Lr21gL.
Acknowledgements
We thank Laura Ferguson, Maurice Bucagu, Cherian Varghese, and Bianca Hemmingsen for their feedback on the review protocol. We also thank our research assistants from the Johns Hopkins Bloomberg School of Public Health (Jingjia Cynthia Li, Jaime Marquis, Hadijja Nakawooya, Sherryn Sherryn, and Xuhao Yang) for their help in screening citations and abstracting data. An early draft of this manuscript was used to inform the WHO guideline on self-care interventions for health and well-being [65] published in July 2021.
Funding
We gratefully acknowledge financial support of The Children’s Investment Fund Foundation (CIFF). The funder played no part in the decision to submit the article for publication, nor in the collection, analysis, and interpretation of data. All authors had full access to all of the data in the study and can take responsibility for the integrity of the data and the accuracy of the data analysis.
Author information
Authors and Affiliations
Contributions
MN conceptualized the study. CEK and PTY designed the protocol with feedback from OT, RG, BL, and MN. PTY ran the database search and oversaw search, screening, full text review, and data abstraction processes with support from DR. CEK and PTY performed data analysis. PTY and DR drafted the manuscript. CEK, DR, CZ, OT, RG, BL, and MN reviewed the draft, provided critical review, and read and approved the final manuscript. The corresponding author, as guarantor, accepts full responsibility for the finished article has access to any data and controlled the decision to publish. The corresponding author attests that all listed authors meet the authorship criteria and that no others meeting the criteria have been omitted. The named authors alone are responsible for the views expressed in this publication and do not necessarily represent the decisions or the policies of the World Health Organization (WHO) or the UNDP-UNFPA-UNICEF-WHO-World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP). The corresponding author, as guarantor, affirms that the manuscript is an honest, accurate, and transparent account of the study being reported; that no important aspects of the study have been omitted; and that any discrepancies from the study as planned (and, if relevant, registered) have been explained. The author(s) read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Ethical approval and patients’ consent to participate was not applicable to this systematic review, since all data came from published articles.
Consent for publication
Not applicable, since all data came from published articles and not from any individual person.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Yeh, P.T., Rhee, D.K., Kennedy, C.E. et al. Self-monitoring of blood pressure among women with hypertensive disorders of pregnancy: a systematic review. BMC Pregnancy Childbirth 22, 454 (2022). https://doi.org/10.1186/s12884-022-04751-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12884-022-04751-7