Abstract
Background
Peak inspiratory and expiratory flows (PIF, PEF) are parameters used to evaluate the mechanics of the respiratory system. These parameters can vary based on whether they are measured using mechanical devices vs. spirometry and based on the barometric pressure at which the measurements are obtained. Our objectives were (1) to report the normal values and variability of PEF and PIF of a Latin American population living at a moderate altitude (2240 m above sea level), (2) to analyze the adjustment of reference values obtained at sea level with those obtained in healthy subjects living at a moderate altitude, and (3) to assess the correlation between PEF obtained by spirometry (PEFs) and PEF obtained by mechanical devices (PEFm).
Methods
In this prospective and transversal study, men and women with good respiratory health aged between 2.8 and 68 years old were invited to participate. Randomly, they underwent spirometry (to measure PEFs and PIFs) and mechanical flowmetry (to measure PEFm).
Results
A total of 314 subjects participated, with an average age of 24.3 ± 16.4 years; 59% were Women. The main determinants for the reference equations were age, weight, height and sex at birth. The agreement of the PEFm, PEFs and PIFs values was inconsistent with that reported by other authors, even at the same barometric pressure. The association between PEFm and PEFs was r = 0.91 (p < 0.001), and the correlation coefficient of concordance was 0.84.
Conclusions
The PEFm, PEFs, and PIFs measurements in individuals living at moderate altitudes are different from those found by other authors in cities with different barometric pressures and ethnicities.
Similar content being viewed by others
Background
Peak inspiratory and expiratory flows (PIF and PEF, respectively) are effort-dependent physiological parameters that are used to assess the mechanics of the respiratory system and provide information on muscle strength, airway caliber, and lung elastic characteristics [1, 2]. PIF/PEF measurements can be performed with a spirometer or by mechanical devices called flowmeters [3].
Mechanical flowmeters for PEF measurement (PEFm) are widely available and have been used primarily in subjects with asthma for home monitoring purposes [4]. These devices help to evaluate airflow limitation and airway response to bronchodilators, allowing the timely detection of decreased expiratory flow [5, 6]. PIF is mainly measured by spirometry (PIFs) and can be very useful in investigating abnormalities in the distal and proximal airways and for outpatient follow-up during pulmonary rehabilitation [7, 8]. Mechanical flowmeters for PIF have been used to determine the most appropriate inhalation device in the treatment of asthma and chronic obstructive pulmonary disease (COPD) [9].
Compared to PEF measurements, PIF measurements are less useful due to lack of available low-cost equipment and reference equations [10, 11] in addition to high test variability and limited knowledge of its clinical applications [12, 13].
Most of the reference equations for PEFm are based on European and Asian populations living at sea level, and although some studies reported a good correlation between PEFm and those obtained by spirometry (PEFs), some authors have reported that PEFm may underestimate the value of expiratory flow when obtained in cities that are at elevations above sea level, probably due to air density [14, 15]. On the other hand, very few studies have reported normal PIF values [10, 11].
The aims of the present study were (1) to report the normal values and variability of PEFm, PEFs and PIFs for a Latin American population living at a moderate altitude; (2) to analyze the adjustment of reference values obtained at sea level with values obtained in healthy subjects living at a moderate altitude; and (3) to assess the correlation between PEFm and PEFs.
Material and methods
Study design and population
A cross-sectional study was conducted at the Department of Respiratory Physiology of the National Institute of Respiratory Diseases in Mexico City between April and September 2019. Healthy men and women, aged 2.8–68.0 years without cardiovascular, hepatic or renal diseases or their antecedents of prematurity, pneumonia, bronchiolitis, or biomass tobacco smoke exposure were invited to participate. These individuals were recruited from schools and workplaces. Those who agreed to participate were required to sign an informed consent form. The study was approved by the Ethics Committee of the institute with the number C12-19.
Anthropometric and pulmonary measurements
The height (cm) and weight (kg) of all the participants were measured using a stadiometer with a scale (Models 206 and 769, Seca, Hamburg, Germany). In addition, participants underwent spirometry, and flowmetry was randomly assigned.
To obtain the PEFs and PIFs, an EasyOne On-PC spirometer (NDD, Zurich, Switzerland) was used. After verification of the spirometer calibration, the maneuver was performed according to American Thoracic Society (ATS) and European Respiratory Society (ERS) 2005 standards [16]. While the participant was sitting upright and with a nasal clip, he or she was asked to breathe at a tidal volume, to perform maximum inhalation and to blow hard and continuously through a sterile mouthpiece until the criterion of forced exhalation was met, and then, the participant was asked to perform a fast and maximum inhalation [16]. The maneuver was repeated until the acceptability and repeatability criteria of the test were met (abrupt and vertical onset, with peak expiratory flow, triangular flow-volume curve, with an extrapolated volume ≤ 150 mL). A 6-s exhalation (or 3 s in children) with a plateau at the end of the forced exhalation of at least 1 s and free of artifacts), the highest value of PEFs and PIFs from the 3 best efforts were used for the analysis.
The PEFm was performed with a Truzone® device (peak flow meter, Monaghan Medical 96510, New York, USA); likewise, with the participant sitting with their back upright and their head slightly raised, they were asked to take a quick, deep breath in and immediately afterward to seal their lips around the mouthpiece and perform a quick, strong exhalation. The PEFm maneuver was repeated 3 times, and the highest value obtained was used for analyses [12].
Statistical analysis
The general characteristics of the population are expressed as the median (minimum–maximum) value.
The coefficient of variation (CV, [standard deviation/mean]*100) among the three measurements of PIFs, PEFs and PEFm was calculated for each participant to estimate within-subject variability. Box plots were used to report the median (p25, p75) coefficient of variation for the sex and age groups (< 10, 10–20, 20–40, > 40).
For the agreement and association analysis, the unit of the PEFm variable was transformed to liters/second (L/s) to be the same as the value obtained by spirometry; for the calculation of the regressions and graphs, the PEFm was kept in its original unit liters/minute (L/min). To evaluate the degree of agreement, the mean of differences, and the 95% limits of agreement between PEFm and PEFs measurements, the concordance correlation coefficient (CCC) and Bland–Altman plot were used. The variables did not follow a normal distribution; therefore, the associations between dependent variables (PEFm, PEFs and PIFs) and independent variables (age, weight, height) were calculated using the Spearman’s correlation coefficient (r).
In regression models, the dependent variables were transformed using the natural logarithm, while the independent variables remained at their original value. Multiple linear and quantile regression were fitted to estimate the reference equations for the mean and the lower limit of normal (LLN, defined as the 5th percentile), respectively. The coefficient of determination (R2, linear model) and pseudo coefficient of determination (pseudo-R2, quantile model) were reported to describe the percentage of variation explained in spirometric variables by the independent variables. Root mean square error (RMSE) was reported as a measurement of goodness of fit.
The obtained values were compared with reference equations from other authors [10, 11, 14, 17,18,19,20,21,22,23,24,25,26,27,28]. Results with a p < 0.05 value was considered statistically significant.
The data were collected using Microsoft Excel version 16.39. Statistical analysis was performed with STATA software (version 12; StataCorp, College Station, TX).
Results
A total of 314 participants were recruited, 188 (59.9%) of whom were Women. The entire group had a median age of 21.8 years (2.8–68.0). Table 1 describes the anthropometric and spirometric characteristics of the population. Figure 1 describes the distribution of the sample according to sex and age groups.
Figure 2 is a box plot for CV according to sex and age group for PEFm, PEFs and PIFs. Variables measured by spirometer had the highest variability regardless of sex and age. Medians of CV for PEFm were under 5% for both women and men and for all the age groups.
The correlation between PEFm and PEFs was 0.91 (p < 0.001) (Fig. 3A). The CCC was 0.84, and the mean difference was − 0.97 ± 1.1 L/s with 95% limits of agreement from − 3.07 to 1.15 L/s. Figure 3B depicts the Bland and Altman graph, which describes that PEFm measurement tends to underestimate the PEFs. Adjusted by body temperature, pressure, and water vapor saturated (BTPS), Fig. 3C shows that the mean differences between PEFs and PEFm decreased to − 0.23 ± 1.1 L/s as well as the 95% limits of agreement (from − 2.32 to 1.87 L/s) with a CCC equal to 0.91.
Table 2 reports the Spearman’s correlation coefficients between spirometric and independent variables. Age, height and weight were statistically significant for men and women. In a multivariate analysis, the best models were those in which the variables of PEFm, PEFs and PIFs were transformed into natural logarithms, while the independent variables remained in their original units.
In Table 3, regression models for the mean and the lower limit of normality (LLN) for PEFm, PEFs and PIFs are described.
The results obtained from PEFm, PEFs and PIFs were compared with those reported by other authors (Additional file 1: Table S1). Table 4 shows the results of the concordance analysis, and Fig. 4 shows these same comparisons between the different authors.
Discussion
The results of this study confirm that the main determinants for obtaining the reference values of PEFm, PEFs and PIFs were age, weight, height and sex at birth and that the measurements in individuals living at a moderate altitude are not interchangeable with those obtained at sea level.
It is well recognized that mechanical "flowmeters" are useful for monitoring patients with obstructive diseases, mainly for patients with asthma [3, 4, 6, 17], due to their availability, portability, and low cost and that do not require specialized training. PEF measurement, either by spirometry or flowmeters, is used to determine the severity of an asthma attack and to monitor the patient's disease at home [4, 29, 30] and has even proposed its use for the diagnosis of the disease [6, 31, 32].
Although the PEFm and the PEFs have a good correlation, there is not an acceptable agreement between the measurements [14, 20, 21]. Differences can even exist between the measurements obtained from the same subject using the same spirometer. When the measurement is obtained with a maneuver that provides a peak flow measurement only vs. a "complete" spirometry maneuver, the PEF value obtained from a short exhalation tends to be higher than the PEF value obtained while performing a forced vital capacity maneuver (29). In the present study, similar results were obtained, with a high correlation (r = 0.91) but with regular agreement (CCC = 0.84), with errors of up to 3 L/s between the measurements with PEFm vs. PEFs. These differences can be expected since the technology used by both devices is different and because the results of PEFs are adjusted based on the correction factor of BTPS units; however, as we demonstrated in the results, even when we adjust the values of PEFm to BTPS units, the agreement between PEFs and PEFm remains practically the same.
Some authors have made reference equations for PEFm adjusting for the BTPS conversion factor [22]; however, we consider that the predicted values should not be adjusted in the day-to-day use of PEFm to facilitate implementation for patients at home, as well as those in primary care settings.
Another important factor that affects the PEFm measurements is the barometric pressure of the location where the measurement is performed [33, 34]. Studies conducted through simulations of people ascending to a high altitude have shown that contrary to the measurements obtained by spirometry [33], the PEFm value is lower at higher altitudes due to the air density. An adjusted PEFm measurement of a 6.6% per 100 mmHg decrease from 760 mmHg in the barometric pressure has been proposed [15, 34]. Gupta et al. found that children living at 2150 m above sea level (masl) had a higher PEFm than those living at 278 (masl) using a Mini Wright® flowmeter and adjusted the result of the measurements of this flowmeter to BTPS units, including air density [22]. It is possible that this finding is substantial because a higher lung volume is usually expected in individuals living at higher altitudes, and by adjusting for air density, higher values are possible. However, we consider that the usefulness of the PEFm is mainly for individual use and perhaps in the clinical context at the first level of care, so making these adjustments in the reference equations could make it difficult to apply on a day-to-day basis.
As shown in Table 4, the results do not agree with those of other authors; Pérez-Padilla et al. found, by studying children under 20 years of age [25] in a Hispanic population living at 2240 masl by means of spirometry, a stronger association and agreement. Therefore, the results obtained in the present study indicate that PEFm can be obtained in individuals who live at a moderate altitude and are between 3 and 68 years of age, which will improve diagnostic evaluations and patient follow-up.
The reference values used to calculate the PIFs value will be useful in the clinical context to evaluate whether asthma patients with different degrees of control or those who experience asthma attacks could perform the inspiratory flow necessary to inhale the medication of the different devices [35]. PIFs also help in the diagnosis of upper airway diseases [36, 37], in the follow-up of neuromuscular disorders as an indicator of dysphagia or cough effectiveness [38], in the follow-up and management of patients with distal airway obstruction [9, 39], and for the complementary prognostic evaluation in tracheostomy [36]. Currently, to the best of our knowledge, the mechanical devices currently on the market for PIF measurements are designed to control the inspiratory flow that a patient with asthma could generate when inhaling a medication, but this does not provide the PIF of an individual because it has a maximum "stop" measurement [40].
There are few reference values for PIFs in the literature, and as shown in Table 4, similar to PEFm and PEFs values, the PIFs values show poor agreement with values obtained in other populations.
This study has several limitations. The number of participants above 55 years is small; moreover, individuals above 68 years were not included, so the proposed reference equations are limited to these ages. The variability of the PIFs maneuvers was very high, perhaps because we could not follow a standardized method, and this problem is also because of a lack in the literature about the “inspiratory measurements” acceptability and repeatability criteria.
Conclusions
The measurements of expiratory and inspiratory flows in individuals living at a moderate altitude are different from those found by other authors in cities with different barometric pressures and different ethnicities. Similar to other respiratory function tests, the main determinants of PEFm, PEFs and PIFs values are age, height, weight and sex. We consider that these reference values can be used in the clinical setting for monitoring and diagnosing respiratory diseases in population living at a moderate altitude.
Availability of data and materials
The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- AIC:
-
Akaike information criterion
- COPD:
-
Chronic Obstructive Pulmonary Disease
- CV:
-
Coefficient of variation
- CCC:
-
Concordance correlation coefficient
- PEFm:
-
Mechanical expiratory flow
- Masl:
-
Meters above sea level
- PEF:
-
Peak expiratory flow
- PIF:
-
Peak inspiratory flow
- PIFs:
-
Peak inspiratory flow obtained by spirometry
- PEFs:
-
Peak expiratory flow obtained by spirometry
- SD:
-
Standard deviation
- r:
-
Sperman correlation coefficient
References
Mikalsen IB, Nassehi D, Oymar K. Vortex whistle and smart phone application for peak flow recordings in asthmatic children: a feasibility study. Telemed J E Health. 2019;25(11):1077–82.
Fernández-Vega M, Ortega-Martell J. Diagnóstico de Asma. Neumol Cir Tórax. 2009;68:S116–22.
Leiner George C, Abramowitz S, Small Maurice J, Stenby Victor B, Lewis William A. Expiratory flow rate. Am Rev Respir Dis. 1963;88(5):644–51.
Lopez-Vina A, del Castillo-Arevalo E. Influence of peak expiratory flow monitoring on an asthma self-management education programme. Respir Med. 2000;94(8):760–6.
Chaves C, Ibiapina Cda C, de Andrade CR, Godinho R, Alvim CG, Cruz AA. Correlation between peak nasal inspiratory flow and peak expiratory flow in children and adolescents. Rhinology. 2012;50(4):381–5.
Global Strategy for Asthma Management and Prevention [https://ginasthma.org/wp-content/uploads/2021/05/GINA-Main-Report-2021-V2-WMS.pdf]
Geddes EL, O’Brien K, Reid WD, Brooks D, Crowe J. Inspiratory muscle training in adults with chronic obstructive pulmonary disease: an update of a systematic review. Respir Med. 2008;102(12):1715–29.
Sharma G, Mahler DA, Mayorga VM, Deering KL, Harshaw O, Ganapathy V. Prevalence of low peak inspiratory flow rate at discharge in patients hospitalized for COPD exacerbation. Chronic Obstr Pulm Dis. 2017;4(3):217–24.
Taube C, Rydzy L, Eich A, Korn S, Kornmann O, Sebastian M, Jorres RA, Buhl R. Use of a portable device to record maximum inspiratory flow in relation to dyspnoea in patients with COPD. Respir Med. 2011;105(2):316–21.
Tomalak W, Radlinski J, Pogorzelski A, Doniec Z. Reference values for forced inspiratory flows in children aged 7–15 years. Pediatr Pulmonol. 2004;38(3):246–9.
Kainu A, Timonen KL, Vanninen E, Sovijarvi AR. Reference values of inspiratory spirometry for Finnish adults. Scand J Clin Lab Invest. 2018;78(4):245–52.
Pride NB. Tests of forced expiration and inspiration. Clin Chest Med. 2001;22(4):599–622.
Price DB, Yang S, Ming SWY, Hardjojo A, Cabrera C, Papaioannou AI, Loukides S, Kritikos V, Bosnic-Anticevich SZ, Carter V, et al. Physiological predictors Of peak inspiRatory flow using Observed lung function resultS (POROS): evaluation at discharge among patients hospitalized for a COPD exacerbation. Int J Chron Obstruct Pulmon Dis. 2018;13:3937–46.
Bouti K, Benamor J, Bourkadi JE. Predictive regression equations of flowmetric and spirometric peak expiratory flow in healthy moroccan children. J Clin Diagn Res. 2017;11(8):SC01–4.
Thomas PS, Harding RM, Milledge JS. Peak expiratory flow at altitude. Thorax. 1990;45:620–2.
Miller M, Hankinson J, Brusasco V. ATS/ERS task force: standarization of lung function testing. Eur Respir J. 2005;26:319–38.
Gregg I, Nunn AJ. Peak expiratory flow in normal subjects. Br Med J. 1973;3(5874):282–4.
Mehta B, Garg K, Ambwani S, Bhandari B, Bhagat OL. Peak expiratory flow rate: a useful tool for early detection of airway obstruction in school children. Open Med J. 2016;3(1):159–65.
Alfredo JL, Mireya FF, Ana CC, María Isabel LA, Jorge OR, Sánchez de Osa Reinaldo B. Medición del pico de flujo espiratorio Valores normales e interpretación en la clasificación del paciente asmático. Rev cub Med Fis Rehab. 2014;6(1):53–60.
Ike D, Bueno CEC, Cutlac Neto J, Pessoa-Santos BV, Jamami M. Analysis of agreement between peak expiratory flow meters and comparison of reference values. Fisioterapia em Movimento. 2017;30(3):509–17.
Lu Y, Zheng J, Liu C, Ai T, Wang N, Meng N, Li S, Luo R, Ren X, Jiang W, et al. Peak expiratory flow among healthy children aged 5–14 years in China. J Thorac Dis. 2018;10(3):1377–85.
Gupta S, Mittal S, Kumar A, Singh K. Peak expiratory flow rate of healthy school children living at high altitude. N Am J Med Sci. 2013;5(7):422.
Hankinson JL, Odencrantz JR, Fedan KB. Spirometric reference values from a sample of the general U.S. population. Am J Respir Crit Care Med. 1999;159(1):179–87.
Pérez-Padilla R, Valdivia G, Muiño A, López María V, Nelly MM, Montes de Oca M, Tálamo C, Lisboa C, Julio P, Jardime José Roberto B, et al. Valores de referencia espirométrica en 5 grandes ciudades de Latinoamérica para sujetos de 40 o más años de edad. Arch Bronchoneumol. 2006;42(7):317–25.
Perez-Padilla R, Regalado-Pineda J, Rojas M, Catalan M, Mendoza L, Rojas R, Chapela R, Villalba J, Torres V, Borja-Aburto V, et al. Spirometric function in children of Mexico City compared to Mexican-American children. Pediatr Pulmonol. 2003;35(3):177–83.
Franca DC, Camargos PA, Jones MH, Martins JA, Vieira Bda S, Colosimo EA, de Mendonca KM, Borja Rde O, Britto RR, Parreira VF. Prediction equations for spirometry in four- to six-year-old children. J Pediatr (Rio J). 2016;92(4):400–8.
Primhak RA, Biggins JD, Tsanakas JN, Hatzimichael A, Milner RD, Karpouzas JG. Factors affecting the peak expiratory flow rate in children. Br J Dis Chest. 1984;78(1):26–35.
Bouti K, Maouni I, Benamor J, Bourkadi JE. Predictive regression equations of flowmetric and spirometric peak expiratory flow in healthy moroccan adults. Int Sch Res Notices. 2017;2017:8985067.
Cano-Zárate R. Flujometría Automonitorización del asma en el paciente pediátrico. Revisión sistemática Alerg Asma Inmun PEdiatr. 2013;22(1):11–8.
Miquel-Gomara Perelló J, Román-Rodríguez M. Grupo De Respiratorio De La Societat Balear De Medicina Familiar I Comunitaria: Medidor de Peak-flow: técnica de manejo y utilidad en Atención Primaria. Medifam. 2002;3:206–13.
British guideline on the management of asthma [https://www.brit-thoracic.org.uk/search/?query=asthma]
Guía Española Para El Manejo Del Asma [www.gemasma.com]
Fischer R, Lang SM, Bergner A, Huber RM. Monitoring of expiratory flow rates and lung volumes during a high altitude expedition. Eur J Med Res. 2005;10:469–74.
Pollard AJ, Mason NP, Barry PW, Pollard RC, Collier DJ, Fraser RS, Miller MR, Milledge JS. Effect of altitude on spirometric parameters and the performance of peak flow meters. Thorax. 1996;51:175–8.
Ghosh S, Ohar JA, Drummond MB. Peak inspiratory flow rate in chronic obstructive pulmonary disease: implications for dry powder inhalers. J Aerosol Med Pulm Drug Deliv. 2017;30(6):381–7.
Lesnik M, De Crouy CO, Herve C, Guerlain J, Perie S. Peak inspiratory flow as predictor for tracheotomy. Eur Ann Otorhinolaryngol Head Neck Dis. 2018;135(1):3–6.
Sanz Santiago V, López Neyra A, Almería Gil E, Villa Asensi JR. Patrones espirométricos en la disfunción de cuerdas vocales. An Pediatr (Barc). 2012;78(3):173–7.
Pitts T, Bolser D, Rosenbek J, Troche M, Sapienza C. Voluntary cough production and swallow dysfunction in Parkinson’s disease. Dysphagia. 2008;23(3):297–301.
Banno M, Ibata H, Niimi T, Sato S, Matsushita R. The usefulness of inspiratory flow rate during inhalation corticosteroid therapy in asthma. Respiration. 2009;78(4):387–92.
In-Check DIAL G16 [https://www.haag-streit.com/clement-clarke/products/inhaler-technique/in-check-dial-g16/?no_cache=1]
Acknowledgements
Not applicable.
Funding
This manuscript did not receive any financial support.
Author information
Authors and Affiliations
Contributions
L.G.R: Study design, literature search, analysis of data, manuscript preparation. K.Y.R.P: Data collection. A.K.G.B: Data collection, study design, manuscript preparation. C.G.V: Analysis of Data. R.F.P: Analysis of data. L.T.B: Review of manuscript. D.M.B: Analysis of data, manuscript preparation. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent participate
The study was approved by the National Institute of Respiratory Diseases “Ismael Cosío Villegas” science and bioethics committee (C12-19). Individuals were recruited from schools and workplaces. Those who agreed to participate were required to sign an informed consent form. Informed consent from parent/ Legally authorized representatives were obtained when participants were under eighteen years old. All methods were carried out in accordance with relevant guidelines and regulations.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Additional file 1.
Supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visithttp://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Gochicoa-Rangel, L., Rodríguez-Peralta, K.Y., Gutiérrez-Bautista, A.K. et al. Maximal inspiratory and expiratory flow at moderate altitude: a study of a Latin American population. BMC Pulm Med 22, 147 (2022). https://doi.org/10.1186/s12890-022-01943-x
Received:
Accepted:
Published: