Abstract
Background
The purpose of this study is to provide a systematic review of the literature pertaining to Patient-Reported Outcome Measurement Information System (PROMIS) validation and utilization as an outcomes metric in total knee arthroplasty (TKA) patients. This is the first systematic review on PROMIS use in total knee arthroplasty patients.
Methods
A systematic search of the Pubmed/MEDLINE and Embase databases was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Study characteristics, patient demographics, psychometric properties (Pearson and Spearman correlation) with legacy patient-reported outcome measurement (PROM) instruments, floor and ceiling effects, responsiveness, and minimum clinically important difference (MCID) and PROMIS outcomes were recorded and analyzed.
Results
Fifteen studies investigating PROMIS in 11,140 patients were included. The weighted-average Pearson correlation coefficient comparing PROMIS domains with legacy patient-reported outcome measurements in total knee arthroplasty patients was 0.62 [standard error (SE) = 0.06] and the weighted-average Spearman correlation comparing PROMIS domains with legacy patient-reported outcome measurements in total knee arthroplasty patients was 0.59 (SE = 0.06), demonstrating moderate-to-strong correlation and validity. There were no differences in weighted average floor [0.03% (SE = 3.1) versus 0% (SE = 0.1) versus 0.01% (SE = 1.1); p = 0.25] or ceiling effects [0.01% (SE = 0.7) versus 0.02% (SE = 1.4) versus 0.04% (SE = 3.5); p = 0.36] between PROMIS and legacy instruments. The weighted average for percentage of patients achieving MCID was 59.1% for global physical health (GPH), 26.0% for global mental health (GMH), 52.7% for physical function (PF), 67.2% for pain interference (PI), and 37.2% for depression.
Conclusion
Notably, PROMIS global physical health, physical function, and pain interference were found to be significantly responsive, with PROMIS pain interference most effectively capturing clinical improvement as evidenced by the achievement of MCID.
Similar content being viewed by others
Main text
Introduction
Patient-reported outcome measures (PROMs) are validated and standardized questionnaires completed by patients that evaluate a patient’s insight into their quality of health, return to baseline function, and mental well-being [1]. Within the field of knee arthroplasty, commonly used PROMs include the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Injury and Osteoarthritis Outcomes Score (KOOS), the Oxford Knee Score (OKS), and the Lower Extremity Activity Scale (LEAS). These validated PROMs are collectively referred to as legacy instruments. However, completion of PROMs can be a challenging technological and administrative enterprise [2,3,4]. Additionally, lack of standardization among PROMs leads to multiple PROM questionnaires being administered per patient; this can increase the potential for “survey question fatigue” and resultant data incompleteness [5,6,7]. Further, Sabah et al. demonstrated that though there are eight joint-specific PROMs available to evaluate knee replacement outcome scores, only three of these (KOOS, LEAS, and WOMAC) have sufficient evidence of validity [8]. Overall, financial barriers, administrative constraints, and lack of standardization have been cited as obstacles to effective PROM collection and utilization. [5,6,7]
The Patient-Reported Outcome Measurement Information System (PROMIS) is an envisioned gold-standard outcome measurement tool intended to provide psychometrically standardized and validated patient-reported outcomes [9]. PROMIS measures a patient’s physical and mental health across multiple domains such as pain intensity (PROMIS Pain Intensity), pain interference (PROMIS PI), and physical function (PROMIS PF) [10]. Pain interference assesses the effects of pain on the important aspects of one’s life, such as the extent to which pain prevents engagement with emotional, social, physical, and cognitive activities. Likewise, PROMIS global domains such as global mental health (GMH) and global physical health (GPH) assess the overall state of one’s mental and physical health, respectively. It is administered in two forms: a computer adaptive test (CAT) and short form. Based on the item response theory (IRT), the CAT test is a sequence of consecutive questions tailored for delivery based on real-time patient responses, thus allowing for streamlined questioning based on the subject’s previous responses. Studies have shown CAT to be more time-efficient than traditional legacy instruments, requiring fewer questions to reach the identical level of responsiveness [11, 12]. Other advantages of PROMIS include its validity, responsiveness, coverage, and decreased floor and ceiling effects compared with legacy instruments across various orthopedic patient populations. [13,14,15]
To support widespread implementation of PROMIS within the practice of specific orthopedic subspecialties and in the perioperative periods of specific procedures, it is important to evaluate the validity and current utilization of these instruments. The purpose of this study is to provide a systematic review of the literature pertaining to PROMIS validation and utilization as an outcome metric in total knee arthroplasty (TKA) patients.
Methods
This systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [16]. The PROSPERO database was searched by two of the authors (NC, PG) for existing systematic reviews on the present topic. Pubmed/MEDLINE and Embase databases were searched using the search terms (“patient-reported outcomes measurement information system” OR “PROMIS”) AND (“knee”) AND (“arthroplasty”) to identify all relevant literature. Inclusion and exclusion criteria for the resultant abstracts were applied once duplicates were excluded. Two independent reviewers evaluated the identified abstracts; if no consensus was reached regarding the choice to include or exclude a particular study, the senior author was consulted, and a consensus was reached. For each included article, the references were manually scanned for additional papers not identified in the original database search. As this was a systematic review of published literature, institutional review board approval was not required.
Published articles reporting on PROMIS in TKA patients were identified (Fig. 1). The inclusion criteria were as follows: any study with level of evidence I–IV that reported the psychometric properties [Pearson and Spearman correlation with legacy instruments, floor and ceiling effects, responsiveness, and minimum clinically important difference (MCID)] and/or utilization of PROMIS in total knee arthroplasty. Study characteristics, patient demographics, psychometric properties, and PROMIS outcomes were recorded and analyzed. Exclusion criteria were as follows: level of evidence V, conference abstracts, reviews, articles written in non-English languages without translation available, and studies that did not distinguish between TKA or total hip arthroplasty (THA), revision TKA, unicompartmental knee arthroplasty, or general knee surgery. Studies were further excluded if PROMIS data were not able to be directly extracted.
The following information was collected: level of evidence, study design, number of patients, mean age of patients, and gender distribution. Pearson’s r and Spearman’s rho were collected to assess the correlation between PROMIS and legacy measures, which included: KOOS Joint Replacement (KOOS-JR), KOOS Functions in Activities of Daily Living (KOOS-ADL), KOOS Sports, KOOS Physical Function Short Form (KOOS-PS), Brief Resilience Scale (BRS), OKS, and modified single assessment evaluation (M-SANE). In this systematic review, very weak correlation is defined as r = 0–0.19, weak as r = 0.20–0.39, moderate as r = 0.40–0.59, strong as r = 0.60–0.79, and very strong as r = 0.80–1.00. Floor and ceiling effects were recorded to assess the coverage (the ability of an instrument to detect the full range of scores of a given measure in a patient population). The generally accepted benchmark for which floor and ceiling effects are considered significant ranges from 5% to 15% of participants scoring the minimum or maximum scores [17, 18]. Responsiveness was evaluated through recorded preoperative and postoperative PROMIS and legacy PROM scores. The established MCID values per PROMIS domain and legacy instrument, as well as the percentage of patients who achieved MCID, was also collected. MCID is the smallest change in scores on a given instrument that represents a clinically important difference to the patient [19]. In general, a smaller MCID is desirable, as that indicates that the change in score is real and not attributed to measurement error.
Studies that did not include analysis of the psychometric properties of PROMIS but reported on PROMIS as an outcome and predictive metric in TKA were also included. Additional data such as patient population, intervention, follow-up time, primary assessment, and main PROMIS findings were collected from each article.
Methodological quality and risk of bias assessment
Two authors (NC, PG) applied the Methodological Index for Non-Randomized Studies (MINORS) criteria to each study included in the systematic review to assess the methodological quality [20]. Cohen’s kappa values were computed to analyze inter-reviewer reliability for each item of the MINORS criteria and assess the degree of concurrence between the two blinded reviewers. The highest attainable score is 24, which denotes that the study under scrutiny is of good methodological quality.
Multiple steps were taken to avoid publication bias, such as including studies that reported both positive and negative results, applying the MINORS criteria to each included study.
Statistical analysis
Weighted averages for the following metrics were calculated: the correlation of PROMIS with legacy instruments (via Pearson and Spearmen correlation coefficients, in which absolute values of coefficients were used); floor and ceiling effects; preoperative, < 3 months postoperative, and ≥ 6 months postoperative PROMIS scores (to assess responsiveness); and MCID scores. The study sample size was used to assign weights. One-way ANOVA and student t-tests were used to determine statistically significant differences. All statistical analyses were carried out in Microsoft Excel Version 16.72, with a cutoff for statistical significance at p < 0.05. Meta-analysis of correlations (https://data-play3.shinyapps.io/Meta_corr/) software was used for meta-analysis, with application of a fixed-effects model to determine whether a statistically significant difference existed between the correlations of PROMIS to legacy instruments between studies.
Results
The preliminary database search yielded 184 studies. Once duplicates were removed, the remaining 122 studies were screened and 15 studies investigating PROMIS in 11,140 patients were ultimately included in this systematic review (Fig. 1; Table 1) [21,22,23,24,25,26,27,28,29,30,31,32,33,34,35].
Validity
Seven studies (n = 7011 patients) reported on PROMIS validity in TKA (Table 2) [21,22,23, 25, 27, 31, 34]. The weighted-average Pearson correlation coefficient was 0.62 [standard error (SE) = 0.06] and the weighted-average Spearman correlation comparing PROMIS domains with legacy PROMs in TKA patients was 0.59 (SE = 0.06) (Fig. 2). The direction of the correlation cannot be commented on as these were absolute value calculations. When evaluating individual PROMIS domains, the weighted-average correlation coefficient for PF was r = 0.79, r = 0.64 for PI, r = 0.30 for GMH, and r = 0.5 for GPH.
Floor and ceiling effects
Three studies reported on the floor and ceiling effects of PROMIS domains and legacy instruments (Table 3) [21, 23, 33]. PF had 0% floor and 0.13% ceiling effects, while PI had 8.5% floor and 0% ceiling effects. GPH had 0.1% floor and 0.2% ceiling effects, and GMH had 0.007% floor and 6.3% ceiling effects. Among PROMIS, KOOS-JR, and M-SANE there were no differences in weighted average floor effects [PROMIS: 0.03% (SE = 3.1) versus KOOS-JR: 0% (SE = 0.1) versus M-SANE: 0.01% (SE = 1.1); p = 0.25]. There were no differences in weighted ceiling effects between PROMIS and legacy instruments [PROMIS: 0.01% (SE = 0.7) versus KOOS-JR: 0.02% (SE = 1.4) versus M-SANE: 0.04% (SE = 3.5); p = 0.36] (Fig. 3).
PROMIS responsiveness
Six studies on 3949 patients reported preoperative and postoperative PROMIS scores (Table 4) [21, 23, 28,29,30, 33]. For GPH, GMH, PF, and PI domains, weighted-average preoperative, < 3 months postoperative, and ≥ 6 months postoperative scores were calculated (Fig. 4). GPH, GMH, and PF all increased from baseline to < 3 months postoperative. (Table 4). These differences were statistically significant for GPH at < 3 months postoperative (baseline to < 3 months postoperative: 38.6 ± 5.3 to 42.4 ± 5.2, p = 0.002) and ≥ 6 months (baseline to ≥ 6 months postoperative: 38.6 ± 5.3 to 44.6 ± 5.7, p = 0.002). The change from baseline to ≥ 6 months postoperative was statistically significant for PF (baseline to ≥ 6 months postoperative: 36.7 ± 5.4 to 42.8 ± 7.4, p = 0.001). PI scores significantly decreased from baseline to postoperative (baseline to ≥ 6 months postoperative: 64.0 ± 6.0 to 53.6 ± 9.6, p = 0.001) Likewise, depression scores decreased from baseline to postoperative, but this was not found to be significant (baseline to ≥ 6 months postoperative: 47.9 ± 9 to 43.3 ± 8.8, p = 0.08). Changes from preoperative to postoperative GMH scores were not found to be statistically significant at < 3 months postoperative (baseline to < 3 months postoperative: 47.0 ± 6.6 to 47.3 ± 5.7, p = 0.2) and ≥ 6 months postoperative (baseline to: 47.0 ± 6.6 to 47.9 ± 5.5, p = 0.1).
MCID
Five studies reported on the MCID and the percentage of patients reaching MCID with PROMIS domains (Table 5) [21, 24, 26, 32, 33]. The weighted-average percentage of patients achieving MCID was 59.1% for GPH, 26.0% for GMH, 52.7% for PF, 67.2% for PI, and 37.2% for depression.
Five studies on 3455 patients utilized PROMIS as an outcome metric (Table 6) [26, 28, 30, 31, 33]. These studies assessed outcomes such as the effectiveness of a certain implant, the effect of preoperative mental health on postoperative outcomes, and the feasibility of PROMIS in bundle-care payment improvement patients.
Meta-analysis
A meta-analysis was performed on seven studies reporting correlations; statistical heterogeneity was found among studies (I2 = 98%, p < 0.0001). Overall, the meta-analysis showed significant difference between correlations (p < 0.0001).
MINORS criteria
The mean MINORS score for all included studies was 19.3 ± 1.3 (range: 17 to 22) points (Table 1). All items assessed using the MINORS criteria demonstrated excellent inter-reviewer reliability with k-coefficient ≥ 0.7 in all items (Appendix 2 Table 9).
Discussion
This is the first systematic review on the psychometric properties and use of PROMIS in assessing TKA outcomes. PROMIS has a moderate-to-strong correlation with the legacy instruments KOOS-JR, KOOS-ADL, KOOS-ADL Sports, OKS, M-SANE, and Brief Resilience Score (BRS), establishing strong criterion validity for PROMIS in TKA patients. PF consistently had strong to very-strong correlations across all compared legacy instruments. GMH was the most variable, with correlations ranging from very weak (r = 0.15) to strong (r = 0.70). This variability within the PROMIS umbrella indicates that certain PROMIS domains may not be as valid for the evaluation of TKA outcomes as others. Our results suggest that the global PROMIS domains (GMH more so that GPH) are less consistently correlated with legacy instruments, while the specific domains (PF and PI) are more consistently strongly correlated. This is likely due to the nonspecific nature of the global domains and their associated broad question banks.
Our study demonstrated 0% floor and ceiling effects for the majority of PROMIS domains (Table 3), showcasing the ability of PROMIS instruments to differentiate between patients both severely and minimally affected by knee arthritis and subsequent TKA. There were no differences found between PROMIS metrics and legacy instruments on pooled analysis of floor and ceiling effects, implying that PROMIS measures are equally effective as KOOS-JR and M-SANE at demonstrating measurement accuracy. PF and PI had insignificant floor and ceiling effects, falling below the 5–15% cutoff range. Similarly, both global PROMIS domains had low floor and ceiling effects. These findings are consistent with the general orthopedic literature: in a cross-sectional study of 94 patients with general knee pain, there were no floor or ceiling effects found with PF, and minimal floor and ceiling effects with KOOS-JR (3.4% and 1.1%, respectively) [36]. Conversely, in the only study that examined PROMIS depression, depression was found to have large floor effects (Lawrie: 21% preoperatively and 38% postoperatively) [33]. The elevated floor effects may indicate that depression may have limited responsiveness in patients who have a lower severity of depression and that its use is limited.
Responsiveness results were variable across different forms of PROMIS. Poor responsiveness was found in GMH and depression. Scores within these domains may be prone to fluctuation, as an individual’s baseline mental health score may be more likely to oscillate than one’s physical function due to mood changes unrelated to TKA. Regarding the global PROMIS domains, responsiveness was more robust at later follow-up (> 6 months postoperative). Responsiveness of an outcome measurement is crucial, as the ability of that tool to discern change through the course of treatment directly augments the ability of that tool to predict outcomes. The ability of PROMIS to capture the assessment of a TKA patient’s overall health while also accurately detecting changes in their knee function further supports its use in this population.
Notably, GPH, PF, and PI had high percentages of patients reaching MCID, with PI most effectively capturing clinical improvement, as evidenced by the achievement of MCID. GMH and depression were less able to showcase clinical improvement, with only 26% and 37.2% of patients achieving MCID, respectively. No statistical differences were found between PROMIS domain and the ability of the legacy instrument to capture clinical improvement. MCID values for PROMIS domains in TKA patients are listed in Table 7, and can be used by clinicians to predict and counsel a patient on how much they are expected to improve after TKA. MCIDs are valued in patient outcomes research as they serve as a standard for treatment success. Reporting MCIDs with PROMIS scores can lead to a more meaningful interpretation of outcome scores.
There are limitations to our study. First, there was some heterogeneity among the PROMIS domains used in this study. Of the seven studies that evaluated PF and PI, four used PF and PI CAT, one used the short form, and two were unspecified. Yet despite this mild heterogeneity, scores from the various forms were comparable, likely due to the common question bank from which they were generated. Another limitation relates to the small number of patients in the analyses of correlation coefficients for some of the PROMIS domains, which could affect the potential clinical significance of the correlation coefficients. The correlation coefficient for PI to KOOS-JR was found to be 0.64, based on a sample size of 124 patients. Despite the strong correlation identified in this study, the small sample size may limit overall generalizability. Additionally, two-thirds of our included 15 studies were retrospective in nature. None used any blinding methods, which may have resulted in selection bias.
Conclusions
Our findings indicate that PROMIS forms are valid and reliable for use by knee arthroplasty surgeons and researchers to evaluate the clinical outcomes of patients undergoing TKA. Given the strengths of validity, responsiveness, ability to detect clinical improvement, and low floor and ceiling effects of both PROMIS PF and PI, we recommend those PROMIS domains be further utilized and studied in the TKA patient population, as they were found to be the most effective in this study. As a standardized method of PROM assessment, PROMIS can help create valid, reliable, and consistent interpretation of the TKA patient population across the orthopedic literature.
Availability of data and materials
The dataset(s) supporting the conclusions of this article is(are) included within the article (and its additional file(s)).
Abbreviations
- PROMIS:
-
Patient-Reported Outcome Measurement Information System
- TKA:
-
Total knee arthroplasty
- PRISMA:
-
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
- PROM:
-
Patient-reported outcome measurement
- MCID:
-
Minimally clinically important difference
- SE:
-
Standard error
- GPH:
-
Global physical health
- GMH:
-
Global mental health
- PF:
-
Physical function
- PI:
-
Pain interference
- WOMAC:
-
Western Ontario and McMaster Universities Osteoarthritis Index
- KOOS:
-
Knee Injury and Osteoarthritis Outcomes Score
- OKS:
-
Oxford Knee Score
- LEAS:
-
Lower Extremity Activity Scale
- CAT:
-
Computer adaptive test
- IRT:
-
Item response theory
- THA:
-
Total hip arthroplasty
- KOOS-JR:
-
Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement
- M-SANE:
-
Modified Single Assessment Numerical Evaluation
- BRS:
-
Brief Resilience Score
References
Black N (2013) Patient reported outcome measures could help transform healthcare. BMJ 346(7896):1–5. https://doi.org/10.1136/bmj.f167
Franklin PD, Lewallen D, Bozic K, Hallstrom B, Jiranek W, Ayers DC (2014) Implementation of patient-reported outcome measures in US total joint replacement registries: rationale, status, and plans. J Bone Jt Surg Am Vol. 96:104–109. https://doi.org/10.2106/JBJS.N.00328
Franklin PD, Harrold L, Ayers DC (2013) Incorporating patient-reported outcomes in total joint arthroplasty registries: challenges and opportunities. Clin Orthop Relat Res 471(11):3482–3488. https://doi.org/10.1007/s11999-013-3193-2
Lizzio VA, Blanchett J, Borowsky P et al (2019) Feasibility of PROMIS cat administration in the ambulatory sports medicine clinic with respect to cost and patient compliance: a single-surgeon experience. Orthop J Sport Med 7(1):1–6. https://doi.org/10.1177/2325967118821875
Hung M, Stuart AR, Higgins TF, Saltzman CL, Kubiak EN (2014) Computerized adaptive testing using the PROMIS physical function item bank reduces test burden with less ceiling effects compared with the short musculoskeletal function assessment in orthopaedic trauma patients. J Orthop Trauma 28(8):439–444. https://doi.org/10.1097/BOT.0000000000000059
Hancock KJ, Glass N, Anthony CA et al (2019) PROMIS: a valid and efficient outcomes instrument for patients with ACL tears. Knee Surg Sport Traumatol Arthrosc 27(1):100–104. https://doi.org/10.1007/s00167-018-5034-z
Gerlach E, Selley R, Johnson D et al (2021) Patient-reported outcomes measurement information system validation in hip arthroscopy: a shift towards reducing survey burden. Cureus. https://doi.org/10.7759/cureus.13265
Sabah SA, Hedge EA, Abram SGF, Alvand A, Price AJ, Hopewell S (2021) Patient-reported outcome measures following revision knee replacement: a review of PROM instrument utilisation and measurement properties using the COSMIN checklist. BMJ Open. https://doi.org/10.1136/bmjopen-2020-046169
Lakey E, Hunt KJ (2019) Patient-reported outcomes in foot and ankle orthopedics. Foot Ankle Orthop. https://doi.org/10.1177/2473011419852930
Fidai MS, Saltzman BM, Meta F et al (2018) Patient-reported outcomes measurement information system and legacy patient-reported outcome measures in the field of orthopaedics: a systematic review. Arthrosc J Arthrosc Relat Surg 34(2):605–614. https://doi.org/10.1016/j.arthro.2017.07.030
Koltsov JCB, Greenfield ST, Soukup D, Do HT, Ellis SJ (2017) Validation of patient-reported outcomes measurement information system computerized adaptive tests against the foot and ankle outcome score for 6 common foot and ankle pathologies. Foot Ankle Int 38(8):870–878. https://doi.org/10.1177/1071100717709573
Rose M, Bjorner JB, Becker J, Fries JF, Ware JE (2008) Evaluation of a preliminary physical function item bank supported the expected advantages of the Patient-Reported Outcomes Measurement Information System (PROMIS). J Clin Epidemiol 61(1):17–33. https://doi.org/10.1016/j.jclinepi.2006.06.025
Ho B, Houck JR, Flemister AS et al (2016) Preoperative PROMIS scores predict postoperative success in foot and ankle patients. Foot Ankle Int 37(9):911–918. https://doi.org/10.1177/1071100716665113
Hung M, Baumhauer JF, Latt LD, Saltzman CL, Soohoo NF, Hunt KJ (2013) Validation of PROMIS® physical function computerized adaptive tests for orthopaedic foot and ankle outcome research. Clin Orthop Relat Res 471(11):3466–3474. https://doi.org/10.1007/s11999-013-3097-1
Trofa DP, Desai SS, Li X, Makhni EC (2022) The current utilization of patient-reported outcome measurement information system in shoulder, elbow, and sports medicine. J Am Acad Orthop Surg 30(12):554–562. https://doi.org/10.5435/jaaos-d-22-00030
Page MJ, Moher D, Bossuyt PM et al (2020) PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews. BMJ 2021:372. https://doi.org/10.1136/bmj.n160
Hung M, Voss MW, Bounsanga J, Gu Y, Granger EK, Tashjian RZ (2018) Psychometrics of the Patient-Reported Outcomes Measurement Information System Physical Function instrument administered by computerized adaptive testing and the disabilities of arm, shoulder and hand in the orthopedic elbow patient population. J Shoulder Elb Surg 27(3):515–522. https://doi.org/10.1016/j.jse.2017.10.015
Hung M, Hon SD, Franklin JD et al (2014) Psychometric properties of the promis physical function item bank in patients with spinal disorders. Spine (Phila Pa 1976) 39(2):158–163. https://doi.org/10.1097/BRS.0000000000000097
Jaeschke R, Singer J, Guyatt GH (1989) Measurement of health status. Ascertaining the minimal clinically important difference. Control Clin Trials 10(4):407–415. https://doi.org/10.1016/0197-2456(89)90005-6
Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (Minors): development and validation of a new instrument. ANZ J Surg 73(9):712–716. https://doi.org/10.1046/j.1445-2197.2003.02748.x
Khalil LS, Darrith B, Franovic S, Davis JJ, Weir RM, Banka TR (2020) Patient-Reported Outcomes Measurement Information System (PROMIS) global health short forms demonstrate responsiveness in patients undergoing knee arthroplasty. J Arthroplasty 35(6):1540–1544. https://doi.org/10.1016/j.arth.2020.01.032
Padilla JA, Rudy HL, Gabor JA et al (2019) Relationship between the patient-reported outcome measurement information system and traditional patient-reported outcomes for osteoarthritis. J Arthroplasty 34(2):265–272. https://doi.org/10.1016/j.arth.2018.10.012
Austin DC, Torchia MT, Werth PM, Lucas AP, Moschetti WE, Jevsevar DS (2019) A one-question patient-reported outcome measure is comparable to multiple-question measures in total knee arthroplasty patients. J Arthroplasty 34(12):2937–2943. https://doi.org/10.1016/j.arth.2019.07.023
Darrith B, Khalil LS, Franovic S et al (2021) Preoperative patient-reported outcomes measurement information system global health scores predict patients achieving the minimal clinically important difference in the early postoperative time period after total knee arthroplasty. J Am Acad Orthop Surg 29(24):e1417–e1426. https://doi.org/10.5435/JAAOS-D-20-01288
Heng M, Tang X, Schalet BD et al (2021) Can the knee outcome and osteoarthritis score (KOOS) function subscale be linked to the PROMIS physical function to crosswalk equivalent scores? Clin Orthop Relat Res 479(12):2653–2664. https://doi.org/10.1097/CORR.0000000000001857
Shaw JH, Lindsay-Rivera KG, Buckley PJ, Weir RM, Banka TR, Davis JJ (2021) Minimal clinically important difference in robotic-assisted total knee arthroplasty versus standard manual total knee arthroplasty. J Arthroplasty 36(7):S233–S241. https://doi.org/10.1016/j.arth.2021.02.038
Shim J, Hamilton DF (2019) Comparative responsiveness of the PROMIS-10 global health and EQ-5D questionnaires in patients undergoing total knee arthroplasty. Bone Jt J. 101 B(7):832–837. https://doi.org/10.1302/0301-620X.101B7.BJJ-2018-1543.R1
Melnic CM, Paschalidis A, Katakam A et al (2021) Patient-reported mental health score influences physical function after primary total knee arthroplasty. J Arthroplasty 36(4):1277–1283. https://doi.org/10.1016/j.arth.2020.10.031
Kagan R, Anderson MB, Christensen JC, Peters CL, Gililland JM, Pelt CE (2018) The recovery curve for the patient-reported outcomes measurement information system patient-reported physical function and pain interference computerized adaptive tests after primary total knee arthroplasty. J Arthroplasty 33(8):2471–2474. https://doi.org/10.1016/j.arth.2018.03.020
Frye BM, Patton C, Kinney JA, Murphy TR, Klein AE, Dietz MJ (2021) A medial congruent polyethylene offers satisfactory early outcomes and patient satisfaction in total knee arthroplasty. Arthroplast Today 7:243-249.e0. https://doi.org/10.1016/j.artd.2020.11.003
Nwankwo VC, Jiranek WA, Green CL, Allen KD, George SZ, Bettger JP (2021) Resilience and pain catastrophizing among patients with total knee arthroplasty: a cohort study to examine psychological constructs as predictors of post-operative outcomes. Health Qual Life Outcomes 19(1):1–12. https://doi.org/10.1186/s12955-021-01772-2
Stiegel KR, Lash JG, Peace AJ, Coleman MM, Harrington MA, Cahill CW (2019) Early experience and results using patient-reported outcomes measurement information system scores in primary total hip and knee arthroplasty. J Arthroplasty 34(10):2313–2318. https://doi.org/10.1016/j.arth.2019.05.044
Lawrie CM, Abu-Amer WY, Clohisy JC (2021) Is the patient-reported outcome measurement information system feasible in bundled payment for care improvement total knee arthroplasty patients? J Arthroplasty 36(1):6–12. https://doi.org/10.1016/j.arth.2020.07.041
Tang X, Schalet BD, Heng M et al (2022) Linking the KOOS-PS to PROMIS physical function in knee patients evaluated for surgery. J Am Acad Orthop Surg 30(6):281–289. https://doi.org/10.5435/JAAOS-D-21-00461
Christensen J, Peters C, Gililland J, Stoddard G, Pelt C (2021) Physical activity, pain interference and comorbidities relate to PROMIS physical function in younger adults following total knee arthroplasty. Disabil Rehabil 43(26):3741–3747. https://doi.org/10.1080/09638288.2020.1749944
Kortlever JTP, Leyton-Mange A, Keulen MHF et al (2020) PROMIS physical function correlates with KOOS, JR in patients with knee pain. J Knee Surg 33(9):903–911. https://doi.org/10.1055/s-0039-1688780
Acknowledgements
Not applicable.
Funding
There was no funding for this study.
Author information
Authors and Affiliations
Contributions
NC: data acquisition; data analysis and interpretation; manuscript writing; manuscript editing; approval of submitted version; PG: data acquisition; creation of tables; approval of submitted version; SSD: data acquisition; creation of figures; data analysis and interpretation; approval of submitted version; TRH: data analysis and interpretation; manuscript editing; approval of submitted version; ALN: conceptualization; data analysis and interpretation; manuscript editing; approval of submitted version; DPT: conceptualization; data analysis and interpretation; manuscript editing; approval of submitted version. All authors have agreed to be personally accountable for their own contributions and to ensure that questions related to the accuracy or integrity of any part of the work will be appropriately investigated and resolved.
Corresponding author
Ethics declarations
Competing interests
Thomas R. Hickernell is on the Board of Directors for the New York State Society of Orthopedic Surgeons. Otherwise, the authors declares that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Czerwonka, N., Gupta, P., Desai, S.S. et al. Patient-reported outcomes measurement information system instruments in knee arthroplasty patients: a systematic review of the literature. Knee Surg & Relat Res 35, 27 (2023). https://doi.org/10.1186/s43019-023-00201-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s43019-023-00201-6