Abstract
The mechanisms underlying movement sense alterations following repeated eccentric contractions remain unclear. This study concomitantly investigated the effects of unilateral eccentric contractions on movement sense and on neuromuscular function at the knee before, immediately after (POST), 24 (POST24) and 48 (POST48) h after the exercise. Twelve participants performed sets of submaximal knee extensors (KE) eccentric contractions until a 20% decrease in maximal voluntary isometric contraction (MVIC) torque was reached. Threshold to detect passive movement (TTDPM) tasks were used to assess movement sense during both knee flexion (TTDPMFLEX) and extension (TTDPMEXT). KE fatigability was assessed using the interpolated twitch technique. TTDPM values expressed in seconds and the percentage of unsuccessful trials only increased at POST during TTDPMFLEX and TTDPMEXT. The 20%-MVIC decrease was associated with significant decreases in voluntary activation level (− 12.7%, p < 0.01) and potentiated doublet torque at 100 Hz (− 18.1%, p < 0.001). At POST24, despite persistent reductions of maximal voluntary and electrically evoked torques associated with increased perceived muscle soreness, TTDPM values and the percentage of unsuccessful trials returned to baseline values. Consequently, movement sense alterations were only observed in the presence of voluntary activation deficits, suggesting that some exercise-induced central alterations may affect the somatosensory function.
Similar content being viewed by others
Introduction
During exercise, the repetition and/or maintenance of muscle contractions results in a transient reduction in the muscle’s ability to produce force or power1. This transient decline, which refers to performance fatigability, is influenced by complex interactions between peripheral and central factors, involving contractile function and muscle activation alterations2,3. In addition, performance fatigability has been associated with alterations in proprioceptive senses, such as the sense of effort4 and the sense of force5.
Proprioceptive senses also encompass kinesthesia, which refers to the conscious sensations of body positions and movements6, whether generated in a voluntary or passive manner7. Kinesthesia, by providing body representation in space, obviously plays a fundamental role in sensorimotor control and especially relies on signals stemming from muscle spindles8. These intramuscular sensory structures are connected to force-generating extrafusal fibers and are sensitive to muscle lengthening and shortening. More precisely, group Ia afferents inform the central nervous system (CNS) of length change and rate of length change8, whereas secondary endings of group II afferents are length sensors9. Thereby, secondary endings seem to play a major role in the position sense, while primary endings predominantly play a role in the movement sense. In addition, previous studies have highlighted that skin stretch receptors also contribute to movement sense through slow adapting type II receptors served by Ruffini endings10. Finally, joint mechanoreceptors contribute to kinesthesia predominantly in extreme angular positions11.
As performance fatigability is inherent to exercise and sports performance, investigating its effects on kinesthesia is of major interest. In the literature, particular focus has been given to the effects of eccentric exercise on kinesthesia because this contraction mode is known to induce muscle damage to force-generating extrafusal fibers12,13. Muscle damage has been assumed to propagate to muscle spindles and lead to kinesthetic alterations8. Although no significant alterations of muscle spindle firing rates in the presence of eccentric-induced damage were reported in animal experimentation14, significant position sense alterations following repeated eccentric contractions were, however, reported in human studies15,16,17,18,19. The origin of the kinesthetic alterations thus remains unclear, despite the recent research pointing to the implication of central alterations17,18,19. Indeed, Da Silva et al.19 observed a significant correlation between knee position sense alterations and decreases in voluntary activation levels (VA) after submaximal eccentric contractions of knee extensors (KE). This suggests that the central alterations induced by the repetition of eccentric contractions might affect the integration and processing of muscle spindle afferents, accounting for position sense alterations.
Contrary to position sense assessment, and as highlighted by Proske20, the effects of repeated eccentric contractions on movement sense have been overlooked. Given its central role in sensorimotor control, investigating the effects of eccentric exercise on movement sense is of interest in the field of applied physiology and sports sciences. Experimentally, two psychophysical tasks have been used to assess movement sense: contralateral tracking tasks21 and threshold to detect passive movement (TTDPM) tasks22,23,24. TTDPM tasks have been shown to be reliable and valid to evaluate movement sense25. During TTDPM tasks, upper or lower limbs are passively moved at very slow angular velocities (i.e., usually below 0.5° s−1) and participants are instructed to press a hand-held button when they perceive a joint movement26. TTDPM values, expressed in seconds, represent the time lapse between the beginning of the joint movement and its detection. Because of the lack of studies and the different tasks used, debate continues as to whether eccentric contractions affect movement sense immediately and over the days following the exercise. Moreover, experiments which have shown movement sense alterations23,24 did not seek to determine the underlying mechanisms.
In this context, knee movement sense was evaluated with TTDPM tasks before and immediately after repeated unilateral KE eccentric contractions, as well as 24, and 48 h post-exercise. To the best of our knowledge, this is the first study to concomitantly evaluate KE neuromuscular function and movement sense, the aim being to better understand the mechanisms underlying movement sense alterations following repeated eccentric contractions. Based on recent observations showing correlations between position sense alterations and VA decreases19, we hypothesized that movement sense alterations would only be observed in the presence of VA deficits, i.e., only immediately after the eccentric exercise.
Methods
Participants
Based on previous studies that reported VA decreases27 and movement sense alterations24 following eccentric exercise of the KE, we used GPower (version 3.1.9.4; Kiel University, Kiel, Germany) and estimated that at least seven participants would be required to find a significant effect for repeated measures within-subject analysis with the power set at 0.95. Accordingly, twelve physically active participants [eight males (age: 26.1 ± 4.4 years; body mass: 79.4 ± 7.8 kg; height: 181.6 ± 5.5 cm) and four females (age: 24.0 ± 1.4 years; body mass: 58.0 ± 4.7 kg; height: 168.8 ± 4.7 cm)] volunteered to participate in this study. Based on our study’s sample size, a sensitivity power analysis with an α of 0.05 and a power of 0.95 resulted in a large effect of f = 0.45. Participants recruited had been free from knee neuromuscular injuries for at least six months and had never undergone any kind of knee surgery. They were fully informed of the testing procedures and gave their informed written consent at their arrival to the laboratory before any testing. The local research ethics committee approved the study and the experimental procedures were conducted in accordance with the latest version of the Declaration of Helsinki (2013), with the exception that the trial was not registered in a trial database.
Experimental protocol
To assess immediate and long-lasting effects of a submaximal eccentric exercise on the knee movement sense and on the KE neuromuscular function, participants were required to perform three experimental sessions separated by 24 h (Fig. 1). Neuromuscular and psychophysical evaluations were performed at four time points: before (PRE), immediately after (POST), 24 (POST24) and 48 (POST48) hours after a submaximal eccentric exercise. The warm-up protocol consisted of three sets interspaced by 1-min of continuous KE concentric and eccentric contractions. Participants were required to progressively increase the intensity of contractions (i.e., from 50 to 90%) with a gradual decrease in angular velocity. Participants first performed 12 contractions at 90° s−1, then 8 contractions at 60° s−1, and finally 4 contractions at 30° s−1.
Submaximal eccentric exercise
Participants performed a unilateral submaximal exercise on their right lower limb that consisted of several sets of 15 submaximal eccentric contractions. The contraction intensity was set at 70% of the maximal voluntary eccentric contraction (ECC) measured in PRE. A horizontal line provided on the screen served as visual feedback of the target intensity. The angular velocity was set at of 30° s−1 with a range of motion of 100°, from 5° to 105° (0° = fully extended). After each KE eccentric contraction, the limb was passively moved into full extension at an angular velocity of 90° s−1. At the end of each set of 15 contractions, participants were asked to perform a maximal voluntary isometric contraction (MVIC) without electric nerve stimulations to evaluate the level of MVIC force loss. If the MVIC decrement was less than 20% of the PRE value, a new set of 15 eccentric contractions was performed. Sets were repeated until participants reached a force loss representing a 20% MVIC decrement. This target value was chosen to match the force decrements observed following ecological exercises such as participating in soccer games28 or downhill running29. An additional set of seven eccentric contractions with similar parameters (i.e., 70% of ECC PRE at 30° s−1) was performed in POST between the two tested directions for movement sense evaluations to maintain the target 20% MVIC loss.
Neuromuscular function assessments
Torque measurements
Participants were placed on an isokinetic dynamometer (Biodex System 4, Biodex Medical Systems, Shirley, NY, USA) showing good reliability, to measure voluntary and electrically evoked torques30. They sat on the dynamometer with a 95° hip angle and the knee joint axis aligned with the axis of the dynamometer lever arm. The lever arm was fixed to the dynamometer motor axis and attached 2 cm above the external malleolus of the participants’ right limb. To avoid any movements during the protocol, participants were firmly strapped with belts over the chest and hips. Torque measurements were recorded at a sampling rate of 500 Hz using commercially available software (Acknowledge 4.1 Biopac Systems, Inc., Goleta, CA,, USA). To evaluate and control participants’ KE fatigability, MVIC and ECC were performed. The knee angle during MVICs was set at 60° of knee flexion, while ECCs were performed over the full range of motion (i.e., from 5 to 105° of knee flexion) at an angular velocity of 30° s−1. Each maximal contraction, whether isometric or eccentric, was interspaced by a 1-min rest. The mean value of the torque signal was calculated over a 500-ms window around the highest torque value for MVICs, while highest peak torque values were recorded for ECC. At PRE, POST24, and POST48, participants performed two MVICs and ECCs. Only the best value of these contractions was retained for data analysis. Immediately after the eccentric exercise (i.e., at POST), only one MVIC and one ECC were performed. At the very end of POST condition, another MVIC (MVICEND) was performed to ensure that the target 20%-MVIC torque decrement was maintained.
Contractile function and voluntary activation of the quadriceps
The effects of the eccentric exercise on both central and peripheral factors of KE fatigability were investigated using the interpolated twitch technique during MVICs31. For this purpose, the cathode, a self-adhesive surface electrode (diameter: 10 mm, Ag–AgCl, Contrôle-Graphique S.A., Brie-Comte-Robert, France) was positioned on the femoral triangle. The anode electrode (self-adhesive rectangular electrode, 5 cm × 9 cm—Stimex, Wetzlar, Germany) was placed at the level of the great trochanter. Placements of cathode and anode electrodes were marked on the skin to ensure a similar repositioning at POST24 and POST48. Rectangular pulses (400 V maximum voltage and 1 ms duration) were delivered at the level of the femoral nerve by an electrical stimulator (Digitimer Stimulator DS7, Digitimer Ltd., Hertfordshire, UK) to induce maximal mechanical twitches (i.e., Tw) and compound muscle action potentials (i.e., maximal M-wave, MMAX) of KE at rest. To ensure adequate assessment of central and peripheral components of KE neuromuscular function32, the stimulation intensity (135.7 ± 28.5 mA) was set to 120% of the optimal stimulation intensity which generated maximal Tw and MMAX. MVICs were associated with an interpolated 100-Hz paired stimuli (Dtsup) over MVIC plateaus and two paired electrical stimulations at a frequency of 10 Hz (Dt10 Hz) and 100 Hz (Dt100 Hz) after the contraction. Interpolated 100-Hz paired stimuli were used to evaluate KE VA. Then, Dtsup and Dt100 Hz were used to calculated VA according to the formula proposed by Merton33:
Dt100 Hz, Dt10 Hz and Dt10 Hz-to-Dt100 Hz ratio (Dt10 Hz/Dt100 Hz) measurements were used for further analysis.
Surface electromyography (EMG) recordings
Before the placement of EMG surface electrodes, participants’ skin was prepared by shaving, lightly abrading and cleaning with alcohol to reduce impedance at the skin–electrode interface below 5 kΩ. Electrical muscle activity was recorded using six pairs of EMG surface electrodes (Ag/AgCl, diameter = 10 mm; inter-electrode distance = 20 mm; Contrôle-Graphique, Brie-Comte-Robert, France) placed according to the SENIAM recommendations34 on the rectus femoris (RF), the vastus lateralis (VL), the vastus medialis (VM) and the biceps femoris (BF) of the exercised limb. A reference electrode was also positioned on the right lateral tibial condyle. To ensure a similar repositioning over the consecutive days (i.e., at POST24 and POST48), each electrode placement was marked on the skin. EMG signals were amplified using the Biopac MP150 system (Biopac Systems, Inc., Goleta, CA,, USA) within a bandwidth frequency ranging from 10 to 500 Hz (common mode rejection ratio = 110 dB, Z Input = 1000 MΩ, gain = 1000). During voluntary and electrically evoked contractions, EMG signals were recorded at a sampling frequency of 2 kHz. Root mean square (RMS) values of KE EMG of each muscle were computed over a 500-ms period during MVICs and ECCs and normalized to the respective MMAX value (i.e., average of the three responses) recorded at each time point31. The level of antagonist coactivation during maximal voluntary torque production was calculated using the ratio between the BF RMS value computed over the same period and the sum of the RMS/MMAX values of RF, VL and VM muscles35.
Psychophysical evaluations
Movement sense evaluations
Evaluations of knee movement sense were performed on the dynamometer using TTDPM tasks during both knee flexion (TTDPMFLEX) and extension (TTDPMFXT). Participants seated in the position described above and all audiovisual cues were eliminated as participants were blindfolded and wore noise-canceling headphones. A cuff was placed on participants’ leg to attenuate any tactile cues related to the displacement of the dynamometer lever arm36. Only the right exercised limb was tested and directions (i.e., TTDPMFLEX and TTDPMEXT) were randomized in a counterbalanced order between participants. One trial was performed as follows: (i) the limb was passively moved and supported by the dynamometer lever arm to a starting angle of 30° of knee flexion, (ii) an experimenter touched the limb of the participant to inform him/her that the movement could be initiated randomly within 30 s, (iii) the dynamometer arm moved passively at a constant very slow speed (i.e., angular velocity of 0.25° s−1)24 into one of the tested directions (i.e., TTDPMFLEX and TTDPMEXT), and (iv) the participant pressed a button placed in his/her left hand as soon as he/she felt sensation of movement or a change in the initial position of their leg. To limit learning effects, participants were familiarized with TTDPM tasks before the start of the protocol. During familiarization, participants performed five trials per tested direction as described previously.
Throughout the experimental protocol, knee angles and time values were recorded over three trials for each tested direction (i.e., TTDPMFLEX and TTDPMEXT) at each time point (i.e., PRE, POST, POST24 and POST48). Instead of using typical angle errors, TTDPM values were computed as the time (in seconds) between movement initiation and the moment when participants pressed the button. Only the best trial of each set per condition (i.e., the trial with the lowest TTDPM values in seconds) was used for further analysis. Moreover, in some trials, participants felt that their limb was moving while it was not (i.e., they pressed the button while the lever arm had not started to move). To consider these failed trials, a statistical analysis of the distribution between successful and unsuccessful trials was performed using binary encoding. For this purpose, we assigned values of 1 to successful trials (TTDPM of ≤ 2.5°, i.e., less than or equal to 10 s to detect the movement) and 0 to unsuccessful trials (TTDPM of > 2.5°, i.e., more than 10 s to detect the movement plus the failed trials). All trials were considered for statistical analyses.
Perceived muscle soreness (PMS)
Participants were asked to estimate the level of their PMS at each time point using a 0–10 numerical rating scale (0: no pain at all; 10: worst pain ever). For this purpose, a constant pressure of 25 N was applied next to the proximal EMG electrode of the corresponding KE muscle (i.e., RF, VL and VM) with a cylindrical object (0.5 cm diameter)37. PMS scores of the RF, VL and VM were averaged across muscles at each time point for further statistical analysis.
Statistical analyses
KE fatigability and PMS parameters were analyzed using one-way analyses of variance (ANOVAs) with repeated measures (PRE vs. POST vs. POST24 vs. POST48). ANOVAs were performed using Statistica software version 8.0 (StatSoft Inc., Tulsa, OK, USA). TTDPM values of the best trial of each set were submitted to a 2-direction (TTDPMFLEX vs. TTDPMEXT) × 4 time points (PRE vs. POST vs. POST24 vs. POST48) repeated measure ANOVA. Data were first screened for normality of distribution and homogeneity of variances using the Kolmogorov–Smirnov test and the Bartlett test. When ANOVAs displayed significant main or interaction effects, a Tukey HSD post-hoc test was applied. Effect sizes were determined from partial eta square values (η2p) with interpretation thresholds fixed at 0.01, 0.08, 0.26, and 0.50 for small, moderate, large, and very large effect sizes, respectively. The values are reported in tables and figures as means ± standard deviations (SD). Significance level was set at p < 0.05 for all statistical analyses.
The effects of the eccentric exercise on the distribution between successful and unsuccessful trials were studied using a generalized linear mixed-effect model (GLMM) with binomial distribution and logit link function performed using IBM SPSS Statistics software for Windows version 27 (IBM Corp., Armonk, NY, USA). GLMMs are an extension of linear mixed models that allow binary repeated measures to be statistically analyzed38. Models with and without inclusion of a random slope were compared using the Akaike information criterion (AIC) and the model with the lowest score was retained as recently recommended39. Thus, the GLMM used included the following fixed effects: the time points (PRE vs. POST vs. POST24 vs. POST48), the tested direction (TTDPMFLEX vs. TTDPMEXT) and the trial order within sets (to control for order effects within measures). When the model displayed significant main or interaction effects (p < 0.05), Sidak adjusted pairwise comparisons were performed.
Ethics declarations
Approval was obtained from the ethics committee of Université Côte d’Azur. This study was conducted in accordance with the latest version of the Declaration of Helsinki.
Consent to participate
Informed consent was obtained from all individual participants included in the study.
Consent for publication
Participants signed informed consent regarding publication of their data.
Results
During the submaximal eccentric exercise, an average eccentric peak torque value of 251.3 ± 81.1 Nm was reached, and participants performed 76 ± 34 contractions to reach the target of a 20% MVIC decrease.
Neuromuscular function parameters
Maximal voluntary torque production
A significant main effect of the time point was found for MVIC (F3, 33 = 13.3, p < 0.001, η2p = 0.55) and ECC (F3, 33 = 12.9, p < 0.001, η2p = 0.54). MVIC and ECC torques were significantly impaired following the eccentric exercise (p < 0.001; Table 1 and Fig. 2a). At POST24, MVIC and ECC torques remained significantly lower compared to PRE values (p < 0.01), but were no longer different from PRE values at POST48 (p > 0.12). MVICEND (189.1 ± 69.1 N.m) was not statistically different from MVIC measured at POST (211.5 ± 66.2 N.m, p = 0.07).
Electrically evoked torques and MMAX
A significant effect of the time point was found for Dt100 Hz (F3,33 = 13.4, p < 0.001, η2p = 0.55), Dt10 Hz (F3,33 = 50.3, p < 0.001, η2p = 0.82) and Dt10 Hz/Dt100 Hz (F3,33 = 44.9, p < 0.001, η2p = 0.80). At POST, Dt100 Hz, Dt10 Hz and Dt10 Hz/Dt100 Hz values were significantly reduced (p < 0.001; Fig. 2c and 2d). The eccentric exercise also induced persistent significant reductions of Dt100 Hz and Dt10 Hz at POST24 (p < 0.05; Fig. 2c,d). Dt100 Hz and Dt10 Hz were no longer different from PRE values at POST48 (p > 0.47).
The fatiguing eccentric exercise had no effect on RF MMAX (p = 0.31, η2p = 0.10), VL MMAX (p = 0.13, η2p = 0.15) or VM MMAX (p = 0.48, η2p = 0.07) values (Table 1).
VA and EMG recordings during maximal torque productions
A significant effect of the time point was found for VA (F3,33 = 6.0, p < 0.01, η2p = 0.35). VA values were significantly reduced at POST only (p < 0.01; Table 1 and Fig. 2b).
Whether during MVIC or ECC, the eccentric exercise did not induce significant changes of RF EMG RMS/MMAX, VL EMG RMS/MMAX, VM EMG RMS/MMAX values (p > 0.07, η2p < 0.20; Table 1). Additionally, the computed antagonist coactivation values during MVIC and ECC were unaffected by the eccentric exercise (p > 0.48, η2p < 0.08; Table 1).
Psychophysical parameters
Movement sense
TTDPM
A significant effect of the time point was found for TTDPM values (F3, 33 = 3.0, p < 0.05, η2p = 0.21; Fig. 3a) but no direction or interaction effects were observed (p > 0.11). Whatever the tested direction, TTDPM values significantly increased at POST compared to PRE (p < 0.05). TTDPM values were no longer different from PRE at POST24, and POST48 (p > 0.84).
Distribution of successful and unsuccessful trials
The GLMM (performed without random slopes of the time point) showed a significant effect of the time point (F3, 263 = 4.5, p < 0.01; Fig. 3b and Table 2). However, no significant effects of the tested direction (p > 0.99), the trial order (p > 0.98) or the interactions between all fixed factors (p > 0.75) were found. Similar to the results of the ANOVA, the number of unsuccessful trials significantly increased at POST (p < 0.01) and was no longer different from PRE at POST24 (p > 0.40). Note that participants made significantly fewer unsuccessful trials at POST48 compared to PRE (p < 0.05).
PMS
A significant effect of the time point was found for PMS scores (F3,33 = 6.9, p < 0.001, η2p = 0.39). PMS scores measured at POST (1.1 ± 1.3) did not differ from PRE values (0.9 ± 0.9, p = 0.90), whereas they were significantly higher at POST24 and POST48 (2.2 ± 1.2 and 2.1 ± 1.5, respectively; p < 0.01).
Discussion
The present study was conducted to evaluate immediate and long-lasting effects of repeated KE eccentric contractions on knee movement sense using TTDPM tasks. For this purpose, concomitant evaluations of KE fatigability and movement sense were carried out before, immediately after, and 24 and 48 h after a submaximal eccentric exercise. The purpose of these concurrent evaluations was to better delineate the mechanisms underlying movement sense alterations following repeated eccentric contractions. In line with our assumptions, movement sense alterations were only observed when VA deficits were present, i.e., only immediately after the eccentric exercise. Despite persistent PMS and alterations of electrically evoked torques at POST24, TTDPM values and the number of unsuccessful trials had returned to baseline values, meaning that movement sense alterations were no longer present at this time point.
At POST, the 20%-MVIC decrease was associated with alterations in electrically evoked torques and VA values with different recovery rates in the days following the eccentric exercise (Table 1 and Fig. 2). In the present study, VA deficits were only observed immediately after the eccentric exercise with a 12.7% decrease at POST (p < 0.01; Fig. 2b). In contrast, at POST24, significant reductions in Dt100 Hz and Dt10 Hz indicate that alterations in muscle contractile properties were still present (p < 0.01; Fig. 2c and 2d). This long-lasting reduction in electrically evoked torques was associated with a significant increase in PMS (p < 0.01), and thus likely indicates the presence of muscle damage commonly observed following repeated eccentric contractions12,13. Our observations of acute VA decreases and persistent alterations in electrically evoked torques are consistent with previous research on damaging eccentric contractions40,41.
To explain the presence of acute movement sense alterations following the eccentric exercise, two distinct hypotheses can be formulated: i) a peripheral hypothesis where eccentric contractions would have altered muscle spindle integrity or ii) a central hypothesis where the integration and/or processing of movement-related sensory inputs at the CNS level would have been altered. It is unlikely that the peripheral hypothesis could account for our observations. First, due to their compliant connections with extrafusal fibers14, muscle spindles seem to be protected from eccentric-induced mechanical damage14, suggesting that muscle spindle sensitivity remained unchanged following the eccentric exercise. Second, the number of unsuccessful trials also increased during TTDPMEXT tasks at POST (Fig. 3b). In this tested direction, movement sense mainly relied on signals arising from muscle spindles of the knee flexors which were not submitted to the damage caused by repeated eccentric contractions. This reinforces the idea that the disturbance of movement sense was not due to alterations of muscle spindle integrity.
Regarding the central hypothesis, movement sense was only altered at POST (Fig. 3a and 3b), i.e., in presence of VA deficits (Fig. 2b). Movement sense seemed to be unaffected by the persistent alterations in muscle contractile function and the increased PMS observed the following days (i.e., at POST24 and POST48; Fig. 3a and 3b). Therefore, movement sense alterations followed the time-course of central factor alterations (i.e., VA deficits) related to KE fatigability rather than those of the peripheral alterations. Altogether, these results support the idea that central mechanisms related to VA deficits could have contributed to the acute movement sense alterations reported in the present study. In line with recent propositions19, the exercise-induced increase neural flow in groups III and IV afferents at the somatosensory cortex42 could have altered the integration and/or processing of Ia and II afferents at the CNS level, contributing to the lowered sensitivity to detect movement-related sensory signals.
Previous research has investigated the immediate and long-lasting effects of repeated eccentric contractions on knee movement sense23,24. Consistent with our results, Torres et al.23 reported movement sense alterations during TTDPMEXT tasks only immediately after a submaximal eccentric exercise. However, the authors did not investigate central and peripheral factors of performance fatigability. In contrast to our findings, Naderi et al.24 observed movement sense alterations up to 48 h after 4 sets of 25 maximal eccentric contractions. In their study, the maximal voluntary torque production capacity was still reduced by 29% 48 h after the eccentric exercise, whereas it had fully recovered in the present study (Table 1 and Fig. 2a). Although VA was not assessed in Naderi et al.’s study, another experiment43 observed that 20% torque production capacity reduction was associated with significant VA deficits 48 h after the exercise. Consequently, one could assume that persistent central factor alterations were present in Naderi et al.’s study, thus contributing to the long-lasting movement sense alterations.
From a methodological perspective, the main limitation of the present study is the absence of an independent familiarization session with TTDPM tasks. This might explain the lower number of unsuccessful trials at POST48 compared to PRE (Fig. 3b and Table 2). Nonetheless, this potential limitation had no effect on TTDPM values of the best trial, as shown by the absence of significant differences between PRE and POST48 values (Fig. 3a). Moreover, the effect of the eccentric exercise on the distribution of successful and unsuccessful trials at POST was substantial (Fig. 3a). Therefore, it is highly probable that a familiarization session would not have changed the general tendency of our results. Nonetheless, in view of this possible learning effect, researchers should pay particular attention when familiarizing participants with the tasks used to evaluate movement sense.
Furthermore, for future studies on the effects of exercise on kinesthesia, researchers should consider different methods and statistical approaches. To facilitate the comparisons between studies, Watkins et al.44 recently proposed to standardize the task parameters (e.g., passive movement speed). As in the present paper, future studies should use a statistical approach that considers the unsuccessful trials during movement sense assessment and not only typical TTDPM values. It would also be important to investigate the effects of eccentric contractions on movement sense during active tasks. For example, a new task modality where participants must detect passive movements while contracting their muscles at controlled intensities might be proposed. This would be interesting since the afferent responses of muscle spindles are more complex and poorly understood during voluntary contractions due to their fusimotor activation45.
Although passive movement sense assessment enhances kinesthesia-related fundamental knowledge, the observations made here and in the literature are hardly applicable to daily life or sport. Experiencing slow passive movements in relaxed muscles is indeed far from ecological conditions. Nonetheless, despite the unpractical nature of the task used to evaluate movement sense, our findings open new avenues of reflection on the effects of VA deficits on kinesthesia. For example, persistent VA deficits observed following soccer games28 may involve kinesthetic alterations in the ensuing days that may prolong the negative impact on motor performance. Future studies should investigate the effects of ecologically induced VA deficits (e.g., after soccer games and trail running) on movement sense. In addition, to better understand the relationship between movement sense alterations and VA deficits, future studies should also focus on the effects of long-lasting VA deficits on movement sense.
Conclusion
In summary, we demonstrated that repeated submaximal eccentric contractions led to movement sense alterations only in presence of VA deficits, i.e., only immediately after the eccentric exercise. The present study broadens knowledge about the effects of repeated eccentric contractions on kinesthetic senses, following a previous study on the assessment of position sense using active bilateral joint position matching tasks19. Therefore, whatever the assessment modality and the kinesthetic sense evaluated (i.e., active contralateral matching for position sense or passive movement detection for movement sense), deleterious effects of repeated eccentric contractions on kinesthesia have been observed only in the presence of VA deficits. Movement and position sense alterations could therefore result from central factor alterations due to the repetition of eccentric contractions. Future studies are now needed to better understand how eccentric contractions affect the integration and processing of kinesthetic inputs at the somatosensory cortex level.
Data availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Gandevia, S. Spinal and supraspinal factors in human muscle fatigue. Physiol. Rev. 81, 1725–1789 (2001).
Kluger, B. M., Krupp, L. B. & Enoka, R. M. Fatigue and fatigability in neurologic illnesses: Proposal for a unified taxonomy. Neurology 80, 409–416 (2013).
Enoka, R. M. & Duchateau, J. Translating fatigue to human performance. Med. Sci. Sports Exerc. 48, 2228–2238 (2016).
Swart, J., Robert Lindsay, T., Ian Lambert, M., Craig Brown, J. & David Noakes, T. Perceptual cues in the regulation of exercise performance-physical sensations of exercise and awareness of effort interact as separate cues. Br. J. Sports Med. 46, 42–48 (2012).
Carson, R. G., Riek, S. & Shahbazpour, N. Central and peripheral mediation of human force sensation following eccentric or concentric contractions. J. Physiol. 539, 913–925 (2002).
Proske, U. & Gandevia, S. C. Kinesthetic senses. Compr. Physiol. 8, 1157–1183 (2018).
Taylor, J. L. Kinesthetic inputs. in Neuroscience in the 21st Century: From Basic to Clinical, Second Edition 1055–1089 (Springer, 2016).
Proske, U. & Gandevia, S. C. The proprioceptive senses: Their roles in signaling body shape, body position and movement, and muscle force. Physiol. Rev. 92, 1651–1697 (2012).
Matthews, P. B. C. Mammalian muscle receptors and their central actions. Q. J. Exp. Physiol. Cogn. Med. Sci. 58, 290–293 (1972).
Collins, D. F., Refshauge, K. M., Todd, G. & Gandevia, S. C. Cutaneous receptors contribute to kinesthesia at the index finger, elbow, and knee. J. Neurophysiol. 94, 1699–1706 (2005).
Burgess, P. R. & Clark, F. J. Characteristics of knee joint receptors in the cat. J. Physiol. 203, 317–335 (1969).
Hotfiel, T. et al. Advances in delayed-onset muscle soreness (DOMS): Part I: Pathogenesis and diagnostics. J. Physiol. 32, 243–250 (2018).
Maeo, S., Ando, Y., Kanehisa, H. & Kawakami, Y. Localization of damage in the human leg muscles induced by downhill running. Sci. Rep. 7, 1–11 (2017).
Gregory, J. E., Morgan, D. L. & Proske, U. Responses of muscle spindles following a series of eccentric contractions. Exp. Brain Res. 157, 234–240 (2004).
Brockett, C., Warren, N., Gregory, J. E., Morgan, D. L. & Proske, U. A comparison of the effects of concentric versus eccentric exercise on force and position sense at the human elbow joint. Brain Res. 771, 251–258 (1997).
Givoni, N. J., Pham, T., Allen, T. J. & Proske, U. The effect of quadriceps muscle fatigue on position matching at the knee. J. Physiol. 584, 111–119 (2007).
Allen, T. J., Leung, M. & Proske, U. The effect of fatigue from exercise on human limb position sense. J. Physiol. 588, 1369–1377 (2010).
Tsay, A., Allen, T. J., Leung, M. & Proske, U. The fall in force after exercise disturbs position sense at the human forearm. Exp. Brain Res. 222, 415–425 (2012).
Da Silva, F. et al. Altered position sense after submaximal eccentric exercise-inducing central fatigue. Med. Sci. Sport. Exerc. 53, 218–227 (2020).
Proske, U. Exercise, fatigue and proprioception: A retrospective. Exp. Brain Res. 237, 2447–2459 (2019).
Allen, T. J. & Proske, U. Effect of muscle fatigue on the sense of limb position and movement. Exp. Brain Res. 170, 30–38 (2006).
Skinner, H. B., Wyatt, M. P., Hodgdon, J. A., Conard, D. W. & Barrack, R. L. Effect of fatigue on joint position sense of the knee. J. Orthop. Res. 4, 112–118 (1986).
Torres, R., Vasques, J., Duarte, J. A. & Cabri, J. M. H. Knee proprioception after exercise-induced muscle damage. Int. J. Sports Med. 31, 410–415 (2010).
Naderi, A., Rezvani, M. H. & Degens, H. Foam rolling and muscle and joint proprioception after exercise-induced muscle damage. J. Athl. Train. 55, 58–64 (2020).
Boerboom, A. L. et al. Validation of a method to measure the proprioception of the knee. Gait Posture 28, 610–614 (2008).
Fridén, T., Roberts, D., Zätterström, R., Lindstrand, A. & Moritz, U. Proprioception in the nearly extended knee: Measurements of position and movement in healthy individuals and in symptomatic anterior cruciate ligament injured patients. Knee Surg. Sport. Traumatol. Arthrosc. 4, 217–224 (1996).
Garnier, Y. M., Paizis, C. & Lepers, R. Corticospinal changes induced by fatiguing eccentric versus concentric exercise. Eur. J. Sport Sci. 19, 166–176 (2019).
Brownstein, C. G. et al. Etiology and recovery of neuromuscular fatigue following competitive soccer match-play. Front. Physiol. 8, 831 (2017).
Giandolini, M. et al. Acute and delayed peripheral and central neuromuscular alterations induced by a short and intense downhill trail run. Scand. J. Med. Sci. Sport. 26, 1321–1333 (2016).
Place, N., Maffiuletti, N. A., Martin, A. & Lepers, R. Assessment of the reliability of central and peripheral fatigue after sustained maximal voluntary contraction of the quadriceps muscle. Muscle Nerve 35, 486–495 (2007).
Place, N. & Millet, G. Y. Quantification of Neuromuscular Fatigue: What Do We Do Wrong and Why?. Sport. Med. 50, 439–447 (2020).
Neyroud, D., Vallotton, A., Millet, G. Y., Kayser, B. & Place, N. The effect of muscle fatigue on stimulus intensity requirements for central and peripheral fatigue quantification. Eur. J. Appl. Physiol. 114, 205–215 (2014).
Merton, P. A. Voluntary strength and fatigue. J. Physiol. 123, 553–564 (1954).
Hermens, H. J., Freriks, B. & Catherine Rau, G. Development of recommendations for SEMG sensors and sensor placement procedures. J. Electromyogr. Kinesiol. 10, 361–374 (2000).
Doix, A. C. M., Lefèvre, F. & Colson, S. S. Time course of the cross-over effect of fatigue on the contralateral muscle after unilateral exercise. PLoS ONE 8, e64910 (2013).
Han, J., Waddington, G., Adams, R., Anson, J. & Liu, Y. Assessing proprioception: A critical review of methods. J. Sport Heal. Sci. 5, 80–90 (2016).
Proske, U. et al. Force matching errors following eccentric exercise. Hum. Mov. Sci. 23, 365–378 (2004).
McCulloch, C. E., Searle, S. R. & Neuhaus, J. M. Generalized, Linear, and Mixed Models 2nd edn. (Wiley, 2008).
Barr, D. J., Levy, R., Scheepers, C. & Tily, H. J. Random effects structure for confirmatory hypothesis testing: Keep it maximal. J. Mem. Lang. 68, 255–278 (2013).
Behrens, M., Mau-Moeller, A. & Bruhn, S. Effect of exercise-induced muscle damage on neuromuscular function of the quadriceps muscle. Int. J. Sports Med. 33, 600–606 (2012).
Pethick, J., Whiteaway, K., Winter, S. L. & Burnley, M. Prolonged depression of knee-extensor torque complexity following eccentric exercise. Exp. Physiol. 104, 100–111. (2018).
Taylor, J. L., Todd, G. & Gandevia, S. C. Evidence for a supraspinal contribution to human muscle fatigue. Clin. Exp. Pharmacol. Physiol. 33, 400–405 (2006).
Skurvydas, A. et al. The effect of sports specialization on musculus quadriceps function after exercise-induced muscle damage. Appl. Physiol. Nutr. Metab. 36, 873–880 (2011).
Watkins, M. et al. A standardized method for measurement of elbow kinesthesia. J. Vis. Exp. 2020, 1–14 (2020).
Delhaye, B. P., Long, K. H. & Bensmaia, S. J. Neural basis of touch and proprioception in primate cortex. Compr. Physiol. 8, 1575–1602 (2018).
Acknowledgements
The authors would like to sincerely thank Gauthier Denis, Jerome Lebrun and Patrick Coquillard for their precious help regarding the use of the generalized linear mixed-effect model. The authors would also like to thank the participants for their time and effort.
Author information
Authors and Affiliations
Contributions
F.D.S., S.S.C., F.Z., F.C., O.G. and F.M. conceived and designed the study. F.D.S., S.S.C., F.Z. and F.M. conducted the experiments. F.D.S., S.S.C. and F.M. analyzed data. F.D.S., S.S.C. and F.M. wrote the first draft of the manuscript. F.D.S., S.S.C., F.Z., F.C., O.G. and F.M. contributed to the writing and approved the final version of the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Da Silva, F., Colson, S.S., Zghal, F. et al. Immediate voluntary activation deficits following submaximal eccentric contractions of knee extensors are associated with alterations of the sense of movement. Sci Rep 12, 2338 (2022). https://doi.org/10.1038/s41598-022-06081-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-022-06081-2
- Springer Nature Limited
This article is cited by
-
Knee position sense and knee flexor neuromuscular function are similarly altered after two submaximal eccentric bouts
European Journal of Applied Physiology (2023)