Abstract
The paper investigates the influence of variation of web stiffener locations on the sectional capacities of SupaCee sections under bending about the weak axis. The SupaCee is the new section made on the basis of the traditional channel section by adding several stiffeners in the web of the channel section to increase stability. The variation of stiffener locations has specific impacts on the flexural capacities of SupaCee sections about the weak axis. With the asymmetrical character of the SupaCee section about the weak axis, the behaviour of this section is analysed when the moment direction is changed. The flexural capacities of cold-formed steel SupaCee sections are determined according to the Australian/New Zealand Standard AS/NZS 4600:2018. Based on the investigated results, it is found that the behaviour of SupaCee sections depends on the moment directions. Also, the web stiffeners should be kept far from the flanges which will be more beneficial for the flexural capacities of SupaCee sections about the weak-axis.
You have full access to this open access chapter, Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
Cold-formed steel structures have been progressively used in buildings due to their convenience in manufacturing, fabrication, transportation and assembly. Their applications are seen in industrial or commercial buildings. More details of the applications can be found in Yu et al. [1]. Cold-formed channel section is a popular product that has been available in the worldwide market for decades. This section has a wide and flat web that is very sensitive to local buckling. This drawback subsequently has been solved by adding stiffeners in this web to create a new section called SupaCee. This SupaCee section will be considered in this investigation.
In terms of design for cold-formed steel structures, Direct Strength Method (DSM) can be seen as a new design method that has attracted the mentions of researchers and designers due to its advantages compared to the traditional effective width method (EWM) [2,3,4]. The new method allows the designers to easily determine the capacities of complex section shapes such as the SupaCee section. This method has been regulated in the Australian/New Zealand Standard AS/NZS 4600:2018 [5]. Elastic buckling analyses are compulsory for the application of this DSM method that can be carried out by using commercial software packages such as CUFSM [6] or THIN-WALL-2 [7, 8]. The design procedure was reported by Pham and Vu [9]. The DSM method will be used for the investigation in this paper.
In literature, a huge number of studies on channel or SupaCee sections under flexure have been available. Almost of the studies are flexure about the strong-axis [4, 10,11,12,13,14,15] whereas these on flexure about the weak-axis remained limited [16, 17]. Impacts of web stiffeners on the capacities of SupaCee sections under bending about the strong axis were studied in previous works [18] whereas their impacts on the weak-axis were not reported. Flexure about the weak axis of SupaCee sections can be found in numerous cases and this has a specific influence on the flexural capacities of SupaCee sections. The strength and behaviour of SupaCee sections under bending about the weak-axis are investigated in this paper. The distances between web stiffeners are subsequently varied in order to study their distance impacts on the flexural capacities about the weak-axis.
2 Sectional Capacities of Cold-Formed Steel Sections Under Bending Using the Direct Strength Method
In this paper, global buckling failures are prevented by using bracing systems as illustrated in Fig. 1 and discussed in Pham and Vu [9]. The member capacities can be determined as the sectional capacities with the replacement of the global buckling moment by the yield moment in the design formulae using the DSM method regulated in the Australian/New Zealand Standard AS/NZS 4600:2018 [5]. The flexural capacity is the smaller of the local buckling moment (Mbl) and the distortional buckling moment (Mbd) as follows:
where \(\lambda_{l} = \sqrt {M_{y} /M_{ol} }\); \(\lambda_{d} = \sqrt {M_{y} /M_{od} }\); My is the yield moment; Mol and Mod are the elastic local and distortional buckling moments respectively and are determined as presented in Sect. 3.
3 Behaviour and Strength of SupaCee Sections Under Flexure About the Weak Axis
SupaCee sections for the investigation are selected from the commercial sections provided by BlueScope Lysaght [19] as listed in Table 1, and their dimensions are illustrated in Fig. 2. Each section is labelled on the basis of its depth and thickness. For instance, “SC25015” means that: “SC” stands for SupaCee; “250” shows the nominal depth of 250 mm; “15” indicates the thickness of 1.5 mm. The grade G450 is used for the investigation as regulated in the Australian Standard AS1397 [20] including yield stress fy = 450 MPa; Young’s modulus E = 200 GPa.
Due to the asymmetry of SupaCee sections about the weak axis, the bending directions are considered in the investigation with the directions regulated in Fig. 3. Elastic buckling analyses are conducted by using the software program THIN-WALL-2 [7, 8]. The elastic buckling stresses are obtained and given in Table 2 for both two bending directions. For the negative direction, two lips are in tension whereas web areas are in compression. This leads to the observation of local buckling in the web as illustrated in Fig. 4a, and distortional buckling does not occur in this situation. For the positive direction, tension is found in the webs and compression is observed in the lips and flange areas adjacent to the lips. Local buckling is seen in the flange areas and distortional buckling is also observed, as illustrated in Fig. 4b, c. Based on the obtained elastic buckling stresses, the flexural capacities of the investigated SupaCee sections are determined according to the DSM method as presented in Sect. 2. The results are given in Table 3. It is found that the local buckling occurs for the negative moment direction and this is distortional buckling for the positive direction.
Table 3 shows that the capacities in the positive direction (M(+)) are significantly higher than those in the negative direction (M(−)). Also, it is found that the ratios M(+)/M(−) are seen as a downward trend when the section thicknesses increase. This is explained that the increase in the thickness allows the webs to become more stable which has significant impacts on the negative moments M(−).
The negative moment is the detrimental case for the flexural capacities of SupaCee sections about the weak-axis, and this moment is also significantly affected by stiffeners. Therefore, the negative direction is used to investigate the impacts of web stiffener locations on the flexural capacities of SupaCee sections about the weak-axis, as presented in Sect. 4.
4 Effects of Web Stiffener Locations on the Flexural Capacities of SupaCee Sections About the Weak-Axis
As seen in Fig. 2, SupaCee has two couples of stiffeners, and these couples are close to the flanges. The distance between two couples is termed “GS”. In this paper, two couples of stiffeners will reach the centroid of the webs; it means that the distance “GS” will decrease, as given in Table 4.
In terms of elastic buckling analyses, elastic buckling stresses are also determined by using the commercial software program THIN-WALL-2 for the negative bending direction, as listed in Table 4. These buckling stresses are utilised for the determination of flexural capacities of SupaCee sections as presented in Table 4.
Table 4 shows the increase in the negative moments if the distances “GS” decrease. It means that the flexural capacities of SupaCee sections become more beneficial if two couples of stiffeners are towards the centroid of the webs. The moment improvements are more significant for sections with small thicknesses. This improvement is about 6% for SC25015, but this is only about 3.6% for SC25024.
5 Conclusions
The paper investigates the behaviour of SupaCee sections under flexure about the weak-axis and the impacts of the distances between web stiffeners of these SupaCee sections on their flexural capacities. Based on the investigated results, several remarks are given as follows:
-
The behaviour of SupaCee sections under bending about the weak-axis depends on the moment directions due to the asymmetry of these sections.
-
The failures of SupaCee sections are governed by the local buckling for the negative moment direction, and they are governed by distortional buckling for the positive moment direction. In general, the flexural capacities of SupaCee sections about the weak-axis are taken as the negative direction moments.
-
As the couples of stiffeners reach toward the centroid of the webs, the negative moments become more beneficial. These stiffener couples should be kept close to the centroid of the webs.
References
Yu WW, Laboube RA, Chen H (2020) Cold-formed steel design. Wiley
Schafer BW, Peköz T (1998) Direct strength prediction of cold-formed members using numerical elastic buckling solutions. In: Fourteenth international specialty conference on cold-formed steel structures
Schafer BW (2002) Local, distortional, and euler buckling of thin-walled columns. J Struct Eng 128(3):289–299
Schafer BW (2008) Review: the direct strength method of cold-formed steel member design. J Constr Steel Res 64:766–778
AS/NZS 4600-2018 (2018) Australian/New Zealand standard TM cold-formed steel structures. The Council of Standards Australia
Li Z, Schafer BW (2010) Buckling analysis of cold-formed steel members with general boundary conditions using CUFSM: conventional and constrained finite strip methods. Saint Louis, Missouri, USA
Nguyen VV, Hancock GJ, Pham CH (2015) Development of the thin-wall-2 for buckling analysis of thin-walled sections under generalised loading. In: Proceeding of 8th international conference on advances in steel structures
Nguyen VV, Hancock GJ, Pham CH (2017) New developments in the direct strength method (DSM) for the design of cold-formed steel sections under localised loading. Steel Constr 10(3):227–233
Pham NH, Vu QA (2021) Effects of stiffeners on the capacities of cold-formed steel channel members. Steel Constr 14(4):270–278
Rasmussen KJR, Hancock GJ (1993) Design of cold-formed stainless steel tubular members. II: Beams. J Struct Eng 119(8):2368–2386
Niu S (2014) Interaction buckling of cold-formed stainless steel beams. PhD Thesis, University of Sydney, Sydney, Australia
Niu S, Rasmussen KJR (2013) Experimental investigation of the local-global interaction buckling of stainless steel i-section beams. Research Report—University of Sydney, Department of Civil Engineering, no 944, pp 1–81
Niu S, Rasmussen KJR, Fan F (2015) Local—global interaction buckling of stainless steel i-beams. II: numerical study and design. J Struct Eng 141(8)
Wang L, Young B (2014) Design of cold-formed steel channels with stiffened webs subjected to bending. Thin-Walled Struct 85:81–92
Yu C, Schafer BW (2003) Local buckling tests on cold-formed steel beams. J Struct Eng 129(12):1596–1606
Oey O, Papangelis J (2020) Nonlinear analysis of cold-formed channels bent about the minor axis. In: Proceedings of the cold-formed steel research consortium colloquium
Oey O, Papangelis J (2021) Behaviour of cold-formed steel channels bent about the minor axis. Thin-Walled Struct 164:107781
Pham NH (2022) Impacts of web stiffener locations on capacities of cold-formed steel SupaCee Sections. In: 3rd international conference on building science, technology and sustainability (ICBSTS2022)
BlueScope Lysaght: Supapurlins Supazeds & Supacees. Blue Scope Lysaghts (2014)
AS1397:2011 (2011) Continuous hot-dip metalic coated steel sheet and strip-coating of zinc and zinc alloyed with aluminium and magnesium. Standards Australia
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Open Access This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.
The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
Copyright information
© 2023 The Author(s)
About this paper
Cite this paper
Pham, N.H. (2023). Effects of Web Stiffeners Locations on Flexural Capacities of SupaCee Sections About the Weak Axis. In: Wang, S., Li, J., Hu, K., Bao, X. (eds) Proceedings of the 2nd International Conference on Innovative Solutions in Hydropower Engineering and Civil Engineering. HECE 2022. Lecture Notes in Civil Engineering, vol 235. Springer, Singapore. https://doi.org/10.1007/978-981-99-1748-8_1
Download citation
DOI: https://doi.org/10.1007/978-981-99-1748-8_1
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-99-1747-1
Online ISBN: 978-981-99-1748-8
eBook Packages: EngineeringEngineering (R0)