Abstract
Objectives
To evaluate and compare the diagnostic potential of whole-body MRI and whole-body 18F-FDG PET/MRI for N and M staging in newly diagnosed, histopathologically proven breast cancer.
Material and methods
A total of 104 patients (age 53.4 ± 12.5) with newly diagnosed, histopathologically proven breast cancer were enrolled in this study prospectively. All patients underwent a whole-body 18F-FDG PET/MRI. MRI and 18F-FDG PET/MRI datasets were evaluated separately regarding lesion count, lesion localization, and lesion characterization (malignant/benign) as well as the diagnostic confidence (5-point ordinal scale, 1–5). The N and M stages were assessed according to the eighth edition of the American Joint Committee on Cancer staging manual in MRI datasets alone and in 18F-FDG PET/MRI datasets, respectively. In the majority of lesions histopathology served as the reference standard. The remaining lesions were followed-up by imaging and clinical examination. Separately for nodal-positive and nodal-negative women, a McNemar chi2 test was performed to compare sensitivity and specificity of the N and M stages between 18F-FDG PET/MRI and MRI. Differences in diagnostic confidence scores were assessed by Wilcoxon signed rank test.
Results
MRI determined the N stage correctly in 78 of 104 (75%) patients with a sensitivity of 62.3% (95% CI: 0.48–0.75), a specificity of 88.2% (95% CI: 0.76–0.96), a PPV (positive predictive value) of 84.6% % (95% CI: 69.5–0.94), and a NPV (negative predictive value) of 69.2% (95% CI: 0.57–0.8). Corresponding results for 18F-FDG PET/MRI were 87/104 (83.7%), 75.5% (95% CI: 0.62–0.86), 92.2% (0.81–0.98), 90% (0.78–0.97), and 78.3% (0.66–0.88), showing a significantly better sensitivity of 18F-FDG PET/MRI determining malignant lymph nodes (p = 0.008). The M stage was identified correctly in MRI and 18F-FDG PET/MRI in 100 of 104 patients (96.2%). Both modalities correctly staged all 7 patients with distant metastases, leading to false-positive findings in 4 patients in each modality (3.8%). In a lesion-based analysis, 18F-FDG PET/MRI showed a significantly better performance in correctly determining malignant lesions (85.8% vs. 67.1%, difference 18.7% (95% CI: 0.13–0.26), p < 0.0001) and offered a superior diagnostic confidence compared with MRI alone (4.1 ± 0.7 vs. 3.4 ± 0.7, p < 0.0001).
Conclusion
18F-FDG PET/MRI has a better diagnostic accuracy for N staging in primary breast cancer patients and provides a significantly higher diagnostic confidence in lesion characterization than MRI alone. But both modalities bear the risk to overestimate the M stage.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Breast cancer is the most common cancer in women worldwide with approximately 2.1 million new cases every year [1]. As in most malignancies, breast cancer mortality increases with the individual tumor burden, while management and prognosis depend heavily on the initial tumor stage [2]. Therefore, for optimal treatment and better survival, precise initial staging plays a pivotal role. Herein, the correct determination of the lymph node status and the detection of distant metastases are of utmost importance. Treatment of breast cancer patients without distant metastases usually includes surgery and chemotherapy, alongside irradiation or further drug therapy before and after surgery [3]. Depending on primary tumor size and locoregional metastases, the surgical procedure of choice can go from breast-preserving resection to complete mastectomy and dissection of the ipsilateral axillary and subclavian lymph nodes. In patients with proven distant metastases a palliative concept is intended, including extensive systemic therapy [4].
The current diagnostic algorithm comprises plain mammography, ultrasound, and in some cases magnetic resonance imaging (MRI) of the breast to evaluate the local tumor extent [3, 5]. Especially the demand for dedicated breast MRI has heavily increased over the last few years [6]. Due to a growing understanding of the importance of an accurate initial staging of breast cancer patients, whole-body imaging with computed tomography (CT) has recently been established in addition to bone scintigraphy for the detection of locoregional and distant metastases [3, 7]. However, whole-body MRI is rarely used for initial staging of breast cancer [8], despite the option of combining dedicated breast MRI with a whole-body examination and its well-known advantages when imaging parenchymal organs [9, 10]. When it comes to PET recent studies have reported a high diagnostic accuracy of 18F-fluorodeoxyglucose-positron emission tomography/CT (18F-FDG PET/CT) in distant breast cancer metastases [11,12,13]. Consequently, hybrid 18F-FDG PET/MRI might serve as a comprehensive “all-in-one” breast cancer staging tool, providing precise local and whole-body staging in one procedure. In smaller cohorts, 18F-FDG PET/MRI has already shown promising results as an alternative modality in primary breast cancer staging [14,15,16,17,18] and in recurrent disease [19,20,21,22].
Therefore, the purpose of this prospective study was to evaluate the diagnostic accuracy of whole-body MRI compared with whole-body 18F-FDG PET/MRI for the initial N and M staging in a large cohort of therapy-naive breast cancer patients.
Material and methods
Patients
This prospective, multi-center study was approved by the institutional review board of the University Duisburg-Essen (study number 17-7396-BO) and Düsseldorf (study number 6040R), and all patients signed a written informed consent form prior to enrolment. Between August 2017 and June 2019, a total of 104 female patients (53.4 ± 12.5, range 29–84 years, Table 1) with newly diagnosed breast cancer were included if they met the following inclusion criteria: [1] Newly diagnosed, treatment-naive T2-tumor or higher T-stage or [2] newly diagnosed, treatment-naive triple-negative tumor of every size or [3] newly diagnosed, treatment-naive tumor with molecular high risk (T1c, Ki67 > 14%, HER2-new over-expression, G3). Exclusion criteria were former malignancies in the last 5 years, contraindications to MRI or MRI contrast agents and pregnancy or breast-feeding. All enrolled patients underwent 18F- FDG PET/MRI.
PET/MRI
The 18F-FDG PET/MRI examinations were performed on an integrated 3.0-Tesla Biograph mMR scanner (Siemens Healthcare GmbH, Erlangen, Germany). To ensure blood glucose levels below 150 mg/dl, blood samples were obtained prior to the injection of a body-weight adapted dose of 18F-FDG (4 MBq/kg bodyweight), resulting in a mean activity of 253.8 ± 42.6 MBq. All patients underwent whole-body 18F-FDG PET/MRI in supine position from head to the mid-thigh using a dedicated 16-channel head-and neck radiofrequency (RF) coil, a 24-channel spine-array RF coil and referring to the patients height three to five flexible 6-channel body array RF coils. PET images were performed simultaneously with the MRI data acquisition and with an acquisition time of 3 min per bed position in four or five positions, depending on the patients’ height (axial FOV 25.8 cm, matrix size 344 × 344). Mean duration time according to manufacturer’s specifications is set at 40 min for the whole-body examination. PET data sets were reconstructed utilizing an iterative ordered-subset expectation maximization (OSEM) algorithm with three iterations and 21 subsets.
For MR-based PET attenuation correction, a two-point (fat, water) coronal 3D-Dixon-VIBE sequence was acquired to generate a four-compartment model (background air, lungs, fat, muscle).
The dedicated 18F- FDG PET/MRI protocol consisted of the following sequences:
-
1.
A transverse T2–weighted (T2w) fat-suppressed half Fourier acquisition single shot turbo spin echo (HASTE) sequence in respiratory medium position and a slice thickness of 7 mm.
-
2.
A transverse diffusion-weighted echo-planar imaging (EPI DWI) sequence (b values 0, 500, 1000) in respiratory medium position with a slice thickness of 5 mm.
-
3.
A transversal T1–weighted (T1w) fat saturated post-contrast volume-interpolated breath-hold examination (VIBE) sequence after intravenous injection of a gadolinium-based contrast agent (0.2 mmol/kg body weight, Dotarem, Guerbet GmbH, Germany) with a slice thickness of 3 mm.
As part of the 18F- FDG PET/MRI examination, a dedicated breast PET/MRI in head-first prone position was performed in all patients prior to whole-body imaging. The presented analysis is based on data of a larger prospective study. Therefore, in consideration of the focus of the presented study, these dedicated breast MRI sequences were not included in evaluation.
Image analysis
MRI and 18F-FDG PET/MRI images were analyzed separately by two experienced radiologists in hybrid imaging and MR imaging with a reading gap of at least 4 weeks to avoid recognition bias. The datasets were evaluated on a dedicated OsiriX workstation (Osirix MD v.9.0.2, Pixmeo, SARL, Bernex, Switzerland). The readers were aware of the diagnosis but blinded to results of N and M stages and results from prior imaging (e.g., sonography). For every patient, the number of lesions, the lesion type (malignant / benign), location, and size as well as the diagnostic confidence of lesion type ratings (5-point ordinal scale, 1 = very low confidence, 2 = low confidence, 3 = indeterminate confidence, 4 = high confidence, 5 = very high confidence) were determined in MRI alone and 18F-FDG PET/MRI. Discrepant interpretations were resolved by consensus decision-making in a separate session between the two readers. Lymph nodes were classified as malignant based on morphological and metabolic criteria, comprising short-axis diameter > 10 mm, spherical configuration, shape (smooth vs. irregular), increased contrast enhancement, diffusion restriction, and focally increased FDG uptake [22, 23]. In accordance with previous publications, findings were considered to be malignant for the evaluation of distant metastases when showing an invasive growth pattern, central necrosis, and typically malignant MR signal characteristics like pathological contrast enhancement and diffusion restriction. On 18F-FDG PET/MRI a visually detectable focal uptake of FDG above background signal counted as a sign of malignancy. The standardized uptake value (SUVmax) was measured in every lesion with a focal FDG uptake by placing a manually drawn polygonal volume of interest (VOI) over each lesion on attenuation-corrected PET images. In all lesions, the maximum diameter was measured.
Reference standard
The 104 patients enrolled in this study had a total of 298 lesions, excluding the primary tumor mass. In 98 patients, 204 out of 298 lesions were confirmed histopathologically. A surrogate reference standard was applied to the remaining 94 lesions containing follow-up imaging and clinical examinations. A decrease in size of suspicious lesions after therapy was regarded as a sign of malignancy. Forty-five lesions were followed-up by CT and 19 lesions by MRI (mean interval 8 ± 5 months). The remaining 30 lesions were followed-up with sonography and clinical examination.
Statistical analysis
Statistical analysis was performed using SPSS Statistics 22 (IBM Inc., Armonk, NY, USA) and Graphpad Prism 7 (GraphPad Software, La Jolla, CA, USA). All data are presented as mean ± standard deviation. The data were analyzed calculating sensitivity, specificity, positive and negative predictive values (PPV, NPV) on a per-patient basis, and a per-lesion basis. Separately for nodal-positive and nodal-negative patients, a McNemar chi2 test was performed to compare sensitivity and specificity between MRI alone and 18F-FDG PET/MRI. We used a Wilcoxon signed rank test to compare the diagnostic confidence of lesion nature assessments (benign/malignant). A p value of less than 0.05 was set as indicating a statistical significance.
Results
Patient-based analysis
When differentiating between nodal-positive and nodal-negative patients, MRI rated 78/104 (75%, 95% CI 65.5–83.0) of the patients correctly, leading to a sensitivity of 62.3% (95% CI: 47.9–75.2), a specificity of 88.2% (95% CI 76.1–95.6), a PPV of 84.6% (95% CI 69.5–94.1), and a NPV of 69.2% (95% CI 56.6–80.1) (see Table 2). The exact N stage (i.e., N0, N1, N2, N3) was determined correctly by MRI in 74 of 104 patients (71.2%, 95% CI 61.5–79.6). The specific distribution of lymph nodes is shown in Fig. 1.
With 18F-FDG PET/MRI differentiation between nodal-positive and nodal-negative patients was rated correctly in 87/104 (83.7%, 95% CI 75.1–90.2) with a sensitivity of 75.5% (95% CI 61.7–86.2), a specificity of 92.2% (95% CI 81.1–97.8), a PPV 90.9% (95% CI 78.3–97.5), and a NPV of 78.3% (95% CI 65.8–87.9). The exact N stage was determined correctly in 86/104 (82.7%, 95% CI 74.0–89.4) of the patients (Fig. 1). A total of 20/53 (37.7%, 95% CI 24.8–52.1) nodal-positive patients were missed by MRI, while only 13/53 (24.5%, 95% CI 13.8–38.3) nodal-positive patients were missed with 18F-FDG PET/MRI (Fig. 4). There were 6 (11.8%, 95% CI 4.4–23.9) false-positive lymph node findings in MRI and 4 (7.8%, 95% CI 2.2–18.9) in PET/MRI.
For nodal-positive women, the exact McNemar chi2 test indicated that nodes were more often found by 18F-FDG PET/MRI than by MRI alone (test statistic = 7.0, p = 0.002). The corresponding difference in sensitivities was 13.2% (95% CI − 4.2–30.7). For nodal-negative women, the test statistic of the exact McNemar chi2 test was 2.0 (p = 0.50). The corresponding difference in specificities was 3.9% (95% CI − 7.6–15.4%). Table 2 gives a detailed overview of N stage performance with MRI and 18F-FDG PET/MRI.
According to the reference standard distant metastases were present in 7/104 patients (6.7%, Table 3, Figs. 2 and 3). The M stage was defined correctly with MRI and 18F-FDG PET/MRI in 100 of 104 patients. As both modalities correctly detected all patients with proven distant metastases, there were false-positive findings in 4 patients (3.8%, 95% CI 1.1–9.6) in each modality, resulting in a sensitivity of 100% (95% CI 59.0–100.0), a specificity of 95.9% (95% CI 90.4–98.9), a NPV of 100% (95% CI 96.3–100.0), and a PPV of 63.7% (95% CI 30.8–89.1). Three of the false-positive ratings were identical in both modalities, comprising one patient with a focal pericarditis showing a normal follow-up MRI after 12 months, one patient with two suspicious lung lesions that were followed-up by CT after 2 months without any sign of malignancy and one patient with multiple enlarged abdominal lymph nodes, which turned out benign in a histopathological examination and on follow-up MRI after 1 year. Additionally, 18F-FDG PET/MRI identified one patient with a suspicious liver lesion and MRI determined a pararenal and a subcutaneous mass in another patient. Both these lesions were non-malignant according to follow-up imaging (Fig. 4).
Lesion-based analysis
In accordance with the reference standard, a total of 298 lesions, containing 155 malignant (52%) and 143 benign lesions (48%), were included in the final analysis (see Table 4, Fig. 3). 18F-FDG PET/MRI showed a higher diagnostic accuracy in the lesion-based analysis than MRI alone with 258 vs. 224 correct lesion nature ratings (86.6% vs. 75.2%, difference: 11.4% (95% CI 5.1–17.7)). Furthermore, the McNemar chi2 test indicated a significant difference for correct malignant lesion rating between MRI alone and 18F-FDG PET/MRI (104 vs. 133 correct lesion nature ratings, 67.1% vs. 85.8%, difference 18.7% (95% CI 9.5–27.9), p < 0.0001) and an equivalent result in detecting benign lesions (120 vs. 125 correct lesion nature ratings, 83.9% vs. 87.4%, difference 3.5% (95% CI − 4.6–11.6), p = 0.063) (see Table 5). In detail, 18F-FDG PET/MRI had 22/155 (14.2%, 95% CI 9.1–20.7) false-negative ratings of axillary and subclavian lymph nodes, due to small lesion size and weak FDG uptake, while MRI alone misinterpreted a total of 38/155 (24.5%, 95% CI 18.0–32.1) of the malignant lesions as not malignant. 18F-FDG PET/MRI correctly identified all of the 31 distant metastases and did not miss any of the malignant lesions while MRI failed to detect 5 bone metastases in one patient and one malignant hilar lymph node as well as seven non-enlarged lymph node metastases in clavicular and mammarian position. Moreover, there were 19 and 18 histopathologically proven false-positive findings in MRI and 18F-FDG PET/MRI, respectively, due to elevated size, suspicious shape, or increased FDG uptake.
Diagnostic confidence
18F-FDG PET/MRI showed a significantly higher overall diagnostic confidence than MRI alone (4.1 ± 0.7 vs. 3.4 ± 0.7, p < 0.0001). Comparing the diagnostic confidence regarding malignant lesions only, containing locoregional and distant metastatic lesions, 18F-FDG PET/MRI was also significantly superior to MRI alone (4.3 ± 0.7 vs. 3.4 ± 0.7, p < 0.0001). Comparing the diagnostic confidence regarding benign lesions only, significant differences in favor of 18F-FDG PET/MRI were observed (3.8 ± 0.7 vs. 3.3 ± 0.7, p < 0.001).
Discussion
This study shows that both the whole-body 18F-FDG PET/MRI and whole-body MRI are valuable diagnostic tools for staging breast cancer patients. 18F-FDG PET/MRI outperforms the accuracy of MRI alone when assessing the N stage, and the diagnostic confidence is significantly higher with 18F-FDG PET/MRI.
Due to a growing understanding of the importance of an accurate initial staging, new staging modalities, primarily the CT, have been established and integrated into breast cancer guidelines [4, 7]. The demand for dedicated breast MRI has heavily increased over the last few years, and based on the growing usage of breast MRI, a subsequent implementation of a whole-body MRI is also conceivable.
In regard to the application of hybrid imaging modalities, the 2015 European Society For Medical Oncology (ESMO) and the 2016 National Comprehensive Cancer Network (NCCN) guidelines consider systemic staging with 18F-FDG PET/CT only for patients with inconclusive results in conventional imaging, in high-risk patients [7] or in patients with newly diagnosed stage III breast cancer, except for operable IIIA breast cancer [24]. However, recent studies showed that 18F-FDG PET/CT detects unsuspected distant metastases in up to 15% of patients compared to the traditional staging algorithm in patients with initial stage IIB breast cancer [13, 25, 26]. Since its introduction in 2011, there has been a large quantity of studies indicating a high diagnostic value of PET/MRI for whole-body cancer staging [27]. Several trials have already noted a superiority of PET/MRI compared with MRI alone in primary and recurrent cancer staging, for example in women with pelvic cancer [23, 28]. Furthermore, some initial studies showed similar results for the superiority of hybrid imaging modalities in detecting malignant lymph nodes and distant metastases in breast cancer [19, 29, 30].
Furthermore, it has been shown that 18F-FDG PET/MRI is superior to 18F-FDG PET/CT in the detection of breast cancer metastases [19]. This applies to axillary lymph node metastases, to liver and bone metastases, and to the total tumor stage [21, 31, 32]. It was emphasized in former studies that in combination with a dedicated breast PET/MRI protocol, 18F-FDG PET/MRI has the appealing potential of a one-stop-shop solution for patients with primary breast cancer [33, 34].The results of our study reveal a significantly better accuracy for determining the correct N stage with 18F-FDG PET/MRI than with MRI alone. Both modalities showed similarly strong results in specificity on a patient-based analysis for the N and M rating. The lesion-based analysis confirmed these results discovering a significant higher diagnostic accuracy of 18F-FDG PET/MRI especially in detecting malignant lesions with lower false-negative ratings, especially in malignant lymph nodes.
Regarding the detection of locoregional lymph node metastases, Grueneisen et al. described a higher sensitivity of PET-based imaging, comparing 18F-FDG PET/CT, 18F-FDG PET/MRI, and MRI alone in a study cohort of 49 primary breast cancer patients with sensitivities of 78%, 78%, and 67% and specificities of 94%, 90%, and 87%, supporting the results of our trial [32]. Ergul et al. also showed a higher performance of PET-based imaging for axillary metastases with a sensitivity of 67% and a specificity of 89% with 18F-FDG PET/CT, compared with 47% and 78% for MRI [35]. The sentinel lymph node biopsy is still the clinical standard for determining nodal-positive patients. In clinical routine, nodal-positive patients undergo axillary lymph node dissection (ALND) in a second surgical intervention. The traditional staging algorithm with clinical examination, sonography, conventional mammography, and breast MRI is a useful but still inadequate predictor of axillary lymph node involvement and is far away from serving as a potential alternative to invasive procedures [36, 37]. Thus, according to previous results and the results of our study, PET/MRI and PET/CT are imaging techniques with a more reliable selection of patients in nodal-positive and nodal-negative and could help to reduce surgical intervention, for example, identifying patients who should be treated with ALND immediately, avoiding a prior lymph node biopsy.
In our study, there was no difference between 18F-FDG PET/MRI and MRI alone when assessing the M stage. Both modalities were able to detect all of the seven patients with distant metastases but bear the risk of overestimating the M stage, rating four patients as false positive. In the study of Sawicki et al. [19], whole-body 18F-FDG PET/MRI reported superiority regarding detection of distant malignant lesions compared to whole-body MRI in recurrent breast cancer patients. Catalano et al. [38] compared whole-body 18F-FDG PET/MRI with whole-body DWI MRI in a smaller cohort study, yielding an insignificantly better performance of PET/MRI in predicting the initial whole-body tumor stage of breast cancer.
Other studies explored the expected high diagnostic potential of 18F-FDG PET/MRI and revealed a higher sensitivity of 18F-FDG PET/MRI over 18F-FDG PET/CT in the diagnosis of locoregional and distant metastases in breast cancer, especially regarding liver and bone metastases, the most common locations of distant breast cancer spread [19, 21, 39]. For instance, Catalano et al. [40] described a significantly higher identification of bone metastases in breast cancer by 18F-FDG PET/MRI compared with 18F-FDG PET/CT (141 vs. 90, p < 0.001) in 25 patients. In the study of Pace et al. [41], 18F-FDG PET/MRI showed equivalent performance to 18F-FDG PET/CT in terms of qualitative lesion detection. Only the overall detection and characterization of lung lesions remains inferior with 18F-FDG PET/CT, caused by the limited ability of MRI to detect small lung lesions [9, 10]. In view of our own results and results of the aforementioned previous studies, it can be summarized that regarding distant metastases detection 18F-FDG PET/MRI appears to have a high sensitivity but bears the risk of false-positive findings. From a clinical perspective, a final histopathological confirmation of suspicious lesions is still required.
Besides, the mere detection of potential lesions, in daily routine diagnostic or interpretation confidence, is also a matter of high interest, and the level of confidence might vary between imaging modalities. In our study, we assessed the practical confidence of the reading radiologists in 18F-FDG PET/MRI and MRI. We found that hybrid PET/MRI imaging has great advantages with regard to the confidence of the final diagnosis that was assigned to a suspicious lesion. We believe that this is before all other reasons based on its ability to visualize pathologically increased glucose metabolism of malignant lesions, thereby, minimizing the uncertainty in the dichotomization between benign and malignant lesion nature compared with conventional imaging techniques [23].
This study has some limitations. First of all, a general limitation of PET/MRI still remains the long acquisition time, reducing the patients comfort during examination [42]. Secondly, since biopsy, especially in patients with advanced tumor stages, was not necessarily required in all lesions according to guideline-based management and ethical standards, a modified reference standard had to be applied including follow-up imaging and clinical examinations. This procedure was in accordance with former studies [15, 19, 28]. Another relative limitation of our study is the fact, that we used the MRI images of the 18F-FDG PET/MRI protocol, as some authors prefer a dedicated MRI. However, a comprehensive MRI protocol was established as part of the 18F-FDG PET/MRI scan, and, based on this protocol, MRI image quality was not limited compared with a stand-alone MRI.
In conclusion, this prospective study demonstrates a high value of 18F-FDG PET/MRI for the N and M staging in patients with primary breast cancer. 18F-FDG PET/MRI has a superior diagnostic performance on a per-patient and a per-lesion basis compared with MRI alone when determining the N-stage. Although MRI alone and 18F-FDG PET/MRI detected all patients with histopathological proven distant metastases, both modalities bear a certain risk to overestimate the M stage. Nevertheless, 18F-FDG PET/MRI should be considered as a useful alternative for systematic staging of breast cancer patients at time of diagnosis.
References
The Global Cancer Observatory G. Breast Cancer. Source: Globocan 2018. World Heal Organ. 2018;876:2018–9.
Michaelson JS, Chen LL, Silverstein MJ, Mihm MCJ, Sober AJ, Tanabe KK, et al. How cancer at the primary site and in the lymph nodes contributes to the risk of cancer death. Cancer. 2009;115(21):5095–107.
Cardoso F, Senkus E, Costa A, Papadopoulos E, Aapro M, André F, et al. 4th ESO-ESMO international consensus guidelines for advanced breast cancer (ABC 4). Ann Oncol. 2018;29(8):1634–57.
Wockel A, Festl J, Stuber T, Brust K, Krockenberger M, Heuschmann PU, et al. Interdisciplinary screening, diagnosis, therapy and follow-up of breast cancer. Guideline of the DGGG and the DKG (S3-level, AWMF registry number 032/045OL, December 2017) - part 2 with recommendations for the therapy of primary, recurrent and advanced Br. Geburtshilfe Frauenheilkd. 2018 Nov;78(11):1056–88.
NCCN. NCCN clinical practice guidelines in oncology breast cancer, Version 2.2016. NCCN.org. 2016
Menezes GL, Knuttel FM, Stehouwer BL, Pijnappel RM, van den Bosch MA. Magnetic resonance imaging in breast cancer: a literature review and future perspectives. World J Clin Oncol. 2014;5(2):61–70.
Senkus E, Kyriakides S, Ohno S, Penault-Llorca F, Poortmans P, Rutgers E, et al. Primary breast cancer: ESMO clinical practice guidelines for diagnosis, treatment and follow-up. Ann Oncol Off J Eur Soc Med Oncol. 2015;26(Suppl 5):v8-30.
Hausmann D, Kern C, Schröder M. Ganzkörper-MRT in der präoperativen Diagnostik des Mammakarzinoms – ein Vergleich mit den Staging- methoden in der S 3-Leitlinie whole-body MRI in preoperative diagnostics of breast cancer – a comparison of. Fortschritte Röntgenstrahlen. 2011;183:1130–7.
Sawicki LM, Grueneisen J, Buchbender C, Schaarschmidt BM, Gomez B, Ruhlmann V, et al. Comparative performance of 18F-FDG PET/MRI and 18F-FDG PET/CT in detection and characterization of pulmonary lesions in 121 oncologic patients. J Nucl Med. 2016;57(4):582–6.
Sawicki LM, Grueneisen J, Buchbender C, Schaarschmidt BM, Gomez B, Ruhlmann V, et al. Evaluation of the outcome of lung nodules missed on 18F-FDG PET/MRI compared with 18F-FDG PET/CT in patients with known malignancies. J Nucl Med. 2016 Jan;57(1):15–20.
Tatsumi M, Cohade C, Mourtzikos KA, Fishman EK, Wahl RL. Initial experience with FDG-PET/CT in the evaluation of breast cancer. Eur J Nucl Med Mol Imaging. 2006;33(3):254–62.
Ulaner GA. PET/CT for patients with breast cancer: where is the clinical impact? Am J Roentgenol. 2019;213(2):254–65.
Ulaner GA, Castillo R, Goldman DA, Wills J, Riedl CC, Pinker-Domenig K, et al. 18F-FDG-PET/CT for systemic staging of newly diagnosed triple-negative breast cancer. Eur J Nucl Med Mol Imaging. 2016;43(11):1937–44.
Beiderwellen K, Grueneisen J, Ruhlmann V, Buderath P, Aktas B, Heusch P, et al. [(18)F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results. Eur J Nucl Med Mol Imaging. 2015 Jan;42(1):56–65.
Beiderwellen K, Gomez B, Buchbender C, Hartung V, Poeppel TD, Nensa F, et al. Depiction and characterization of liver lesions in whole body [(1)(8)F]-FDG PET/MRI. Eur J Radiol. 2013;82(11):e669–75.
Heusch P, Buchbender C, Kohler J, Nensa F, Gauler T, Gomez B, et al. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT. J Nucl Med. 2014;55(3):373–8.
Kirchner J, Sawicki LM, Nensa F, Schaarschmidt BM, Reis H, Ingenwerth M, et al. Prospective comparison of 18 F-FDG PET/MRI and 18 F-FDG PET/CT for thoracic staging of non-small cell lung cancer. Eur J Nucl Med Mol Imaging. 2019;46(2):437–45.
Botsikas D, Bagetakos I, Picarra M, Da Cunha Afonso Barisits AC, Boudabbous S, Montet X, et al. What is the diagnostic performance of 18-FDG-PET/MR compared to PET/CT for the N- and M- staging of breast cancer? Eur Radiol. 2019;29(4):1787–98.
Sawicki LM, Grueneisen J, Schaarschmidt BM, Buchbender C, Nagarajah J, Umutlu L, et al. Evaluation of 18F-FDG PET/MRI, 18F-FDG PET/CT, MRI, and CT in whole-body staging of recurrent breast cancer. Eur J Radiol. 2016;85(2):459–65.
Grueneisen J, Sawicki LM, Wetter A, Kirchner J, Kinner S, Aktas B, et al. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: a comparison of different MR sequences for whole-body restaging of breast cancer patients. Eur J Radiol. 2017 Apr;89:14–9.
Melsaether AN, Raad RA, Pujara AC, Ponzo FD, Pysarenko KM, Jhaveri K, et al. Comparison of whole-body 18F FDG PET/MR imaging and whole-body 18F FDG PET/CT in terms of lesion detection and radiation dose in patients with breast cancer. Radiology. 2016;281(1):193–202.
Grueneisen J, Nagarajah J, Buchbender C, Hoffmann O, Schaarschmidt BM, Poeppel T, et al. Positron emission tomography / magnetic resonance imaging for local tumor staging in patients with primary breast cancer. Investig Radiol. 2015;50(8):1–9.
Sawicki LM, Kirchner J, Umutlu L, Forsting M, Schaarschmidt BM, Ruhlmann V, et al. Comparison of 18F–FDG PET/MRI and MRI alone for whole-body staging and potential impact on therapeutic management of women with suspected recurrent pelvic cancer: a follow-up study. Eur J Nucl Med Mol Imaging. 2017;45(4):622–9.
Gradishar WJ, Anderson BO, Balassanian R, Blair SL, Burstein HJ, Cyr A, et al. Invasive breast cancer version 1.2016, NCCN Clinical Practice Guidelines in Oncology. J Natl Compr Cancer Netw. 2016;14(3):324–54.
Ulaner GA, Castillo R, Wills J, Gönen M, Goldman DA. 18F–FDG-PET/CT for systemic staging of patients with newly diagnosed ER-positive and HER2-positive breast cancer. Eur J Nucl Med Mol Imaging. 2017;44(9):1420–27.
Riedl CC, Slobod E, Jochelson M, Morrow M, Goldman DA, Gonen M, et al. Retrospective analysis of 18F-FDG PET/CT for staging asymptomatic breast cancer patients younger than 40 years. J Nucl Med. 2014;55(10):1578–83.
Spick C, Herrmann K, Czernin J. 18F-FDG PET/CT and PET/MRI perform equally well in cancer: evidence from studies on more than 2,300 patients. J Nucl Med. 2016.
Grueneisen J, Beiderwellen K, Heusch P, Gratz M, Schulze-Hagen A, Heubner M, et al. Simultaneous positron emission tomography/magnetic resonance imaging for whole-body staging in patients with recurrent gynecological malignancies of the pelvis: a comparison to whole-body magnetic resonance imaging alone. Investig Radiol. 2014.
Kanda T, Kitajima K, Suenaga Y, Konishi J, Sasaki R, Morimoto K, et al. Value of retrospective image fusion of 18F-FDG PET and MRI for preoperative staging of head and neck cancer: comparison with PET/CT and contrast-enhanced neck MRI. Eur J Radiol. 2013;82(11):2005–10.
Anderson WF, Reiner AS, Matsuno RK, Pfeiffer RM. Shifting breast cancer trends in the United States. J Clin Oncol. 2007;25(25):3923–9.
van Nijnatten TJA, Goorts B, Vöö S, de Boer M, Kooreman LFS, Heuts EM, et al. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients: a feasibility study. Eur J Nucl Med Mol Imaging. 2018;45(2):179–186.
Grueneisen J, Nagarajah J, Buchbender C, Hoffmann O, Schaarschmidt BM, Poeppel T, et al. Positron emission tomography/magnetic resonance imaging for local tumor staging in patients with primary breast cancer: a comparison with positron emission tomography/computed tomography and magnetic resonance imaging. Investig Radiol. 2015;50(8):505–13.
Tabouret-Viaud C, Botsikas D, Delattre BMA, Mainta I, Amzalag G, Rager O, et al. PET/MR in breast cancer. Semin Nucl Med. 2015;45(4):304–21.
Kirchner J, Grueneisen J, Martin O, Oehmigen M, Quick HH, Bittner AK, et al. Local and whole-body staging in patients with primary breast cancer: a comparison of one-step to two-step staging utilizing 18F-FDG-PET/MRI. Eur J Nucl Med Mol Imaging. 2018;45(13):2328–37.
Ergul N, Kadioglu H, Yildiz S, Yucel SB, Gucin Z, Erdogan EB, et al. Assessment of multifocality and axillary nodal involvement in early-stage breast cancer patients using 18F-FDG PET/CT compared to contrast-enhanced and diffusion-weighted magnetic resonance imaging and sentinel node biopsy. Acta Radiol. 2015;56(8):917–23.
Lee B, Lim AK, Krell J, Satchithananda K, Coombes RC, Lewis JS, et al. The efficacy of axillary ultrasound in the detection of nodal metastasis in breast cancer. Am J Roentgenol. 2013;200(3):w314–20.
Valente SA, Levine GM, Silverstein MJ, Rayhanabad JA, Weng-Grumley JG, Ji L, et al. Accuracy of predicting axillary lymph node positivity by physical examination, mammography, ultrasonography, and magnetic resonance imaging. Ann Surg Oncol. 2012;19(6):1825–30.
Catalano OA, Daye D, Signore A, Iannace C, Vangel M, Luongo A, et al. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast. Int J Oncol. 2017;51(1):281–8.
Plecha DM. Faulhaber P. European Journal of Radiology: PET/MRI of the breast; 2017.
Catalano OA, Nicolai E, Rosen BR, Luongo A, Catalano M, Iannace C, et al. Comparison of CE-FDG-PET/CT with CE-FDG-PET/MR in the evaluation of osseous metastases in breast cancer patients. Br J Cancer. 2015;112(9):1452–60.
Pace L, Nicolai E, Luongo A, Aiello M, Catalano OA, Soricelli A, et al. Comparison of whole-body PET/CT and PET/MRI in breast cancer patients: lesion detection and quantitation of 18F-deoxyglucose uptake in lesions and in normal organ tissues. Eur J Radiol. 2014;83(2):289–96.
Gückel B, Gatidis S, Enck P, Schäfer J, Bisdas S, Pfannenberg C, et al. Patient comfort during positron emission tomography/magnetic resonance and positron emission tomography/computed tomography examinations: subjective assessments with visual analog scales. Investig Radiol. 2015;50(10):726–32.
Data availability statement
The corresponding author had full access to all data in the study and had all responsibility for the decision to submit for publication.
Funding
Open Access funding provided by Projekt DEAL. The study is funded by the Deutsche Forschungsgemeinschaft (DFG), the German Research Foundation (BU3075/2-1).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
All procedures performed were in accordance with the ethical standards of the institutional research committee of the University Duisburg-Essen (study number 17-7396-BO) and Düsseldorf (study number 6040R) and with the principles of the 1964 Declaration of Helsinki and its later amendments.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Gratitude to Deutsche Forschungsgemeinschaft (DFG) for financially promoting this research project.
Disclaimer
The funding foundation was not involved in trial design, patient recruitment, data collection, analysis, interpretation or presentation, writing or editing of the reports, or the decision to submit for publication.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This article is part of the Topical Collection on Oncology - Chest
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Bruckmann, N.M., Sawicki, L.M., Kirchner, J. et al. Prospective evaluation of whole-body MRI and 18F-FDG PET/MRI in N and M staging of primary breast cancer patients. Eur J Nucl Med Mol Imaging 47, 2816–2825 (2020). https://doi.org/10.1007/s00259-020-04801-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-020-04801-2