Abstract
Introduction
The effect of valve type on outcomes in transfemoral transcatheter aortic valve replacement (TF-TAVR) has recently been subject of debate. We investigate outcomes of patients treated with balloon-expanding (BE) vs. self-expanding (SE) valves in in a cohort of all these procedures performed in Germany in 2018.
Methods
All patients receiving TF-TAVR with either BE (N = 9,882) or SE (N = 7,413) valves in Germany in 2018 were identified. In-hospital outcomes were analyzed for the endpoints in-hospital mortality, major bleeding, stroke, acute kidney injury, postoperative delirium, permanent pacemaker implantation, mechanical ventilation > 48 h, length of hospital stay, and reimbursement. Since patients were not randomized to the two treatment options, logistic or linear regression models were used with 22 baseline patient characteristics and center-specific variables as potential confounders. As a sensitivity analysis, the same confounding factors were taken into account using the propensity score methods (inverse probability of treatment weighting).
Results
Baseline characteristics differed substantially, with higher EuroSCORE (p < 0.001), age (p < 0.001) and rate of female sex (p < 0.001) in SE treated patients. After risk adjustment, no marked differences in outcomes were found for in-hospital mortality [risk adjusted odds ratio (aOR) for SE instead of BE 0.94 (96% CI 0.76;1.17), p = 0.617] major bleeding [aOR 0.91 (0.73;1.14), p = 0.400], stroke [aOR 1.13 (0.88;1.46), p = 0.347], acute kidney injury [OR 0.97 (0.85;1.10), p = 0.621], postoperative delirium [aOR 1.09 (0.96;1.24), p = 0.184], mechanical ventilation > 48 h [aOR 0.98 (0.77;1.25), p = 0.893], length of hospital stay (risk adjusted difference in days of hospitalization (SE instead of BE): − 0.05 [− 0.34;0.25], p = 0.762) and reimbursement [risk adjusted difference in reimbursement (SE instead of BE): − €72 (− €291;€147), p = 0.519)] There is, however, an increased risk of PPI for SE valves (aOR 1.27 [1.15;1.41], p < 0.001). Similar results were found after application of propensity score adjustment.
Conclusions
We find broadly equivalent outcomes in contemporary TF-TAVR procedures, regardless of the valve type used. Incidence of major complications is very low for both types of valve.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Transcatheter aortic valve replacement (TAVR) as a treatment for aortic stenosis (AS) has only been available for less than 20 years now [1]. The technique has evolved very rapidly over this period and has seen widespread adoption beyond its initial primary indication for use in patients whose risk profile makes surgical valve replacement (SAVR) too dangerous. Current ESC/EACTS Guidelines recommend TAVR via the transfemoral access route (TF-TAVR) even in intermediate-risk patients [2]. Today, TAVR is the most commonly used treatment for AS in Europe [3] and the United States [4].
Two principles of valve expansion were developed from the beginning of the TAVR era and are now well established: expansion via inflation of a balloon (balloon expandable, BE) or self-expansion (SE). The two most widely used valve types are the BE Edwards Sapien and the SE Medtronic Evolut/Corevalve. Both valve types showed convincing results compared to SAVR in randomized controlled trials for high, intermediate and low-risk patients suffering from severe aortic valve stenosis [5,6,7,8,9,10].
Based on the results of those studies, the two designs are meant to be interchangeable with each other in clinical practice. The parallel availability of two quite different valve expansion methods naturally raises the question of whether or not one of these methods produces superior results. In order to elucidate differences in clinical outcomes, several studies were recently published. The SOLVE-TAVI trial randomized 447 patients in Germany to either SE Evolut R or BE Sapien 3 valve and confirmed equivalent outcomes [11]. However, two retrospective analyses including cases performed in France between 2013 and 2018 found superior outcomes of BE valves in clinical practice [12, 13].
The present study aims to provide further evidence from clinical practice by analyzing results from BE and SE TAVR performed in Germany—a country with a high rate of TAVR procedures. By focusing on the year 2018, the analysis ensures that the use of the most recent valve technologies and the performance of a state-of-the-art procedure are evaluated.
Methods
Data
Since 2005, data on all hospitalizations in Germany have been available for scientific use via the Diagnosis Related Groups statistics collected by the Research Data Center of the Federal Bureau of Statistics (DESTATIS). These hospitalization data, including diagnoses and procedures, are a valuable source of representative nationwide data on the in-hospital treatment of patients. This database represents a virtually complete collection of all hospitalizations in German hospitals that are reimbursed according to the Diagnosis Related Groups system. From this database, we extracted data on 17,295 cases of isolated TF-TAVR procedures conducted in 2018. As described previously, patients with a baseline diagnosis of pure aortic regurgitation (main or secondary diagnosis other than I35.0, I35.2, I06.0, I06.2) and those with concomitant cardiac surgery or percutaneous coronary intervention were not included in this analysis [14]. A complete list of procedure codes may be found in Table S1.
Our study did not involve direct access by the investigators to data on individual patients but only access to summary results provided by the Research Data Center. Therefore, approval by an ethics committee and informed consent were determined not to be required, in accordance with German law. All summary results were anonymized by DESTATIS. In practice, this means that any information allowing the drawing of conclusions about a single patient or a specific hospital was censored by DESTATIS to guarantee data protection. Moreover, in order to prevent the possibility to draw conclusions to a single hospital the data are verified and situationally censored by DESTATIS in those cases.
Endpoints
The analysis focused on eight different end points: in-hospital mortality, bleeding events, stroke, acute kidney injury, postoperative delirium, permanent pacemaker implantation (PPI), mechanical ventilation exceeding 48 h, length of hospital stay and reimbursement. Stroke and acute kidney injury were defined using ICD, Tenth Revision (ICD-10) codes (secondary diagnosis I63* or I64 and N17*, respectively).
Bleeding was defined as requiring a transfusion of > 5 units of red blood cells and identified using OPS-codes (8–800.c1 to 8–800.cr). In-hospital mortality, length of mechanical ventilation, and length of hospital stay were part of DESTATIS’ main set of variables. For all other comorbidities, the existing anamnestic or acute distinctive codes were used (we have discussed OPS and ICD codes in detail previously [14]).
For calculation of the estimated logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), we were able to populate all fields except for critical preoperative state and left ventricular function. In these, we assumed an inconspicuous state (i.e., no critical preoperative state and no left ventricular dysfunction) and thus calculated a best-case scenario.
Statistical analysis
In a previous study, Reinöhl et al. [14] identified 20 baseline patient characteristics to describe risk profiles between procedural groups. Since patients were not randomized to the two treatment options (TF-TAVR using either BE or SE valve), logistic or linear regression models were used with these 20 baseline patient characteristics included as potential confounders (all covariates listed in Table 1). Nonelective emergency performance of the procedure and case volume per center per year were also added as confounders. To account for the correlation of error terms of patients treated in the same hospital, a random intercept was included at the center level. See Table S2 for results of the different regression analyses.
As a sensitivity analysis, potential confounding factors were taken into account using the propensity score methods. In detail, the propensity score was used for adjustment. The propensity score was estimated using a multivariable logistic regression model, with the two treatment options (TF-TAVR using either BE or SE valve) as the dependent variable and all of the baseline characteristics listed in Table 1 as independent variables. Then, propensity score adjustment was applied using the propensity score as continuous covariate. Again, logistic regression models with a random intercept at the center level were conducted.
No imputation for missing values could be conducted due to the absence of codes indicating that data were missing. If the patient’s electronic health record did not include information on a clinical characteristic, it was assumed that that characteristic was not present. Furthermore, no adjustment for multiple testing was carried out. Thus, p values may not be interpreted as confirmatory but are descriptive in nature and inferences drawn from the 95% confidence intervals may not be reproducible.
All analyses were performed with Stata 16 (StataCorp, College Station, Texas, USA).
Results
Baseline characteristics
The baseline characteristics of the two patient cohorts are shown in Table 1. SE valves were used somewhat more often, with 7,413 BE procedures and 9,882 SE procedures performed. The cohorts differ significantly in the characteristics EuroSCORE (BE lower), age (BE lower), female sex (more likely in SE), CAD (more likely in BE), hypertension (more likely in SE), previous MI after 1 year (more likely in BE), previous cardiac surgery (more likely in SE), carotid disease (more likely in BE) and pulmonary hypertension (more likely in BE). The difference between groups is particularly marked regarding patient sex, with only 42.57% of patients receiving a BE valve being female, but 57.14% of patients receiving a SE valve. Interestingly, the share of non-elective emergency performance of the procedures and case volumes per center per were highly comparable between the two treatment options.
Unadjusted in-hospital outcomes
Unadjusted in-hospital outcomes are shown in Table 2. No marked difference was found for the outcomes in-hospital mortality (2.32% BE, 2.21%SE, p = 0.617), bleeding (2.35% BE, 2.27% SE, p = 0.727) and mechanical ventilation > 48 h (2.00% BE, 2.00% SE, p = 0.973). BE valves were associated with a lower risk for stroke (1.70% BE, 2.19% SE, p = 0.023), PPI (11.52% BE, 14.33% SE, p < 0.001) and postoperative delirium (7.70% BE, 8.93% SE, p = 0.004), while SE valves were associated with less acute kidney injury (8.92% BE, 8.03% SE, p = 0.039), a shorter length of hospital stay (12.54 days BE, 12.20 days SE, p = 0.004) and less reimbursement (€28,846 BE, €28,630 SE, p = 0.009).
Risk adjusted in-hospital outcomes
Adjusted results are shown in Fig. 1. No marked difference in outcomes was found for in-hospital mortality (risk adjusted odds ratio (aOR) for SE instead of BE 0.94 [96%CI 0.76;1.17], p = 0.617), major bleeding (aOR 0.91 [0.73; 1.14, p = 0.400), stroke (aOR 1.13 [0.88; 1.46], p = 0.347), acute kidney injury (aOR 0.97 [0.85; 1.10], p = 0.621), postoperative delirium (aOR 1.09 [0.96; 1.24], p = 0.184), mechanical ventilation > 48 h (aOR 0.98 [0.77;1.25], p = 0.893), length of hospital stay (risk adjusted difference in days of hospitalization: − 0.05 [− 0.34;0.25], p = 0.762) and reimbursement (− €72 [-€291;€147], p = 0.519). There is, however, an increased risk of PPI for SE valves (aOR 1.27 [1.15;1.41], p < 0.001).
See Table S2 for results of the different regression analyses.
Similar results were found after the propensity score approach. Detailed results of the propensity score approach can be found in Table S2.
Discussion
In our analysis of in-hospital outcomes in a large national cohort of more than 17,000 patients with aortic stenosis treated with TAVI, no systematic difference was observable between balloon and self-expandable TAVI valves.
The risk for in-hospital mortality, major bleeding, acute kidney injury, postoperative delirium, prolonged mechanical ventilation, or prolonged hospital stay was similar between BE and SE TAVI valves in Germany in 2018. Our results offer a logical comparison with two registries reported from a recent French national registry by Van Belle et al. [12] and a study based on French administrative data by Deharo et al. [13], although Deharo et al. do not report in-hospital outcomes.
The German and Van Belle cohorts are comparable with regard to age and risk profile such as measured by the EuroSCORE, with the French cohort being slightly older and having a slightly higher EuroSCORE. The Deharo cohort is slightly older, with no EuroSCORE given. In total more TAVR procedures are performed in Germany, with over 17,000 cases in 2018 compared to about 6,000 cases per year (31, 113 between 2014 and 2018) in France, as reported by Deharo et al. When regarding mortality as primary endpoint, the difference is relvant. In the Van Belle cohort, with patients recruited from 2013–2015, there is an in-hospital mortality of 4.2% for BE and 5.6% for SE valves, whereas the German patients treated in 2018 show mortalities of 2.32% for BE and 2.21% for SE. A previous paper of ours3 finds an in-hospital mortality for TF-TAVR in Germany for 2014 and 2015 of only 3.23%, indicating that the difference is not entirely due to the technological progress in the meantime. A higher experience in Germany may be one reason for the observed differences. This is line with a recent randomized trial with 447 patients11 treated in Germany with a 30-day mortality between 2.3 and 3.2%. This study randomized patients to BE and SE valves and found equivalent results for the primary valve-related composite efficacy endpoint. However, in-hospital mortality – a component of the composite endpoint—was significantly lower in the BE treated group.
Two studies analyzing early generation BE or SE valves found comparable outcomes. The randomized CHOICE trial including 241 patients [15] recently published 5-year outcomes, observing no significant difference in outcomes between the valve types, albeit with limited statistical power. Another study from 2016, describing the outcomes of 793 propensity-score matched patients from four European heart centers treated with either Medtronic CoreValve or Edwards SAPIEN/SAPIEN XT, likewise found no differences in outcomes at 30 days and 1 year [16].
The CENTER trial [17] pooled and analyzed data from 10 registries or clinical trials and did find differences in outcomes between the valve types. Incidences of stroke and pacemaker implantation were higher in SE valves, however, incidence of major bleeding was higher in BE valves. Patients receiving SE valves were more likely to suffer from stroke and postoperative delirium, although the risk was not significantly higher after risk adjustment. However, the increase in neurological complications matches the, albeit nonsignificant, findings of Van Belle et al. for stroke and those of the CENTER trial in patients receiving SE valves. Given these findings, further studies addressing potential underlying factors be warranted.
Recent data suggest that valve selection should be adjusted to certain patients’ anatomies, or when particular characteristics are present [18, 19]1. In our study and some more recent publications [18, 20], which left the choice of device to the discretion of the heart team, women were significantly more likely to be treated with SE valves, indicating a significant degree of differentiation in target populations for the respective valve types already existing in clinical practice. The reason for the higher use of SE valves might be suprannular engineering, which allows larger TAVR valve areas in smaller annuli.
However, our study suggests that all comers can be treated with any type of valve—whenever anatomically possible—and can expect an excellent procedural outcome.
Limitations
One limitation of this study is the lack of long-term follow-up, which is due to the fact that the data source used does not include identifying information on individuals, meaning that later hospitalizations or their absence cannot be connected to the patients from our cohort. Our study thus solely provides data on in-hospital outcomes, albeit for a very large, complete national yearly cohort of procedures. Moreover, the administrative data set lacks relevant clinical information (such as echocardiographic findings or anatomical characteristics), preventing operative risk assessment and a better understanding of the underlying valvular pathomechanism. Therefore, only an approximation of the logistic EuroSCORE, in fact a conservative or ‘best-case scenario’ estimate, is applied.
Another limitation is the lack of information in the dataset on the exact model of device used beyond the type—for SE valves, for example, the ACURATE neo [21] or the CoreValve [19] are in use in Germany.
Conclusion
We find comparable outcomes in contemporary TAVR procedures in Germany regardless of the valve type used. Incidence of major complications is very low for both types of valves, and has further improved from the already low level described during the last years. Our finding of a higher incidence of neurological complications when using self-expanding valves matches that of a comparable previous national cohort from France. Investigation into the causative factors might be warranted if this trend continues to be observed.
Change history
03 March 2022
In this article the following funding information was added: Open Access funding enabled and organized by Projekt DEAL.
References
Cribier A, Eltchaninoff H, Bash A et al (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106(24):3006–3008. https://doi.org/10.1161/01.CIR.0000047200.36165.B8
Baumgartner H, Falk V, Bax JJ et al (2017) 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 38(36):2739–2791. https://doi.org/10.1093/eurheartj/ehx391
Stachon P, Kaier K, Zirlik A et al (2019) Risk-adjusted comparison of in-hospital outcomes of transcatheter and surgical aortic valve replacement. J Am Heart Assoc. https://doi.org/10.1161/JAHA.118.011504
D’Agostino RS, Jacobs JP, Badhwar V et al (2019) The society of thoracic surgeons adult cardiac surgery database: 2019 update on outcomes and quality. Ann Thorac Surg 107(1):24–32. https://doi.org/10.1016/j.athoracsur.2018.10.004
Smith CR, Leon MB, Mack MJ et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364(23):2187–2198. https://doi.org/10.1056/NEJMoa1103510
Leon MB, Smith CR, Mack MJ et al (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374(17):1609–1620. https://doi.org/10.1056/NEJMoa1514616
Mack MJ, Leon MB, Thourani VH et al (2019) Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med 380(18):1695–1705. https://doi.org/10.1056/NEJMoa1814052
Adams DH, Popma JJ, Reardon MJ et al (2014) Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med 370(19):1790–1798. https://doi.org/10.1056/NEJMoa1400590
Reardon MJ, Van Mieghem NM, Popma JJ et al (2017) Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med 376(14):1321–1331
Popma JJ, Deeb GM, Yakubov SJ et al (2019) Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med 380(18):1706–1715. https://doi.org/10.1056/NEJMoa1816885
Thiele H, Kurz T, Feistritzer H-J et al (2020) Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. Eur Heart J 41(20):1890–1899. https://doi.org/10.1093/eurheartj/ehaa036
Van Belle E, Vincent F, Labreuche J et al (2020) Balloon-expandable versus self-expanding transcatheter aortic valve replacement: a propensity-matched comparison from the FRANCE-TAVI registry. Circulation 141(4):243–259. https://doi.org/10.1161/CIRCULATIONAHA.119.043785
Deharo P, Bisson A, Herbert J et al (2020) Impact of sapien 3 balloon-expandable versus evolut R self-expandable transcatheter aortic valve implantation in patients with aortic stenosis: data from a nationwide analysis. Circulation 141(4):260–268. https://doi.org/10.1161/CIRCULATIONAHA.119.043971
Reinöhl J, Kaier K, Reinecke H et al (2015) Effect of availability of transcatheter aortic valve replacement on clinical practice. N Engl J Med 373:2438–2447. https://doi.org/10.1056/NEJMoa1500893
Abdel-Wahab M, Landt M, Neumann F-J et al (2020) 5-year outcomes after tavr with balloon-expandable versus self-expanding valves. JACC Cardiovasc Interv 13(9):1071–1082. https://doi.org/10.1016/j.jcin.2019.12.026
Chieffo A, Buchanan GL, Van Mieghem NM et al (2013) Transcatheter aortic valve implantation with the edwards SAPIEN versus the medtronic corevalve revalving system devices. J Am Coll Cardiol 61(8):830–836. https://doi.org/10.1016/j.jacc.2012.11.050
Vlastra W, Chandrasekhar J, Muñoz-Garcia AJ et al (2019) Comparison of balloon-expandable vs self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration. Eur Heart J 40(5):456–465. https://doi.org/10.1093/eurheartj/ehy805
Kim W-K, Blumenstein J, Liebetrau C et al (2017) Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification. Clin Res Cardiol 106(12):995–1004. https://doi.org/10.1007/s00392-017-1149-3
Abdelghani M, Mankerious N, Allali A et al (2018) Bioprosthetic valve performance after transcatheter aortic valve replacement with self-expanding versus balloon-expandable valves in large versus small aortic valve annuli. JACC Cardiovasc Interv 11(24):2507–2518. https://doi.org/10.1016/j.jcin.2018.07.050
Rogers T, Steinvil A, Buchanan K et al (2017) Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding devices. J Intervent Cardiol 30(4):356–361. https://doi.org/10.1111/joic.12389
Husser O, Kim W-K, Pellegrini C et al (2017) Multicenter comparison of novel self-expanding versus balloon-expandable transcatheter heart valves. JACC Cardiovasc Interv 10(20):2078–2087. https://doi.org/10.1016/j.jcin.2017.06.026
Funding
Open Access funding enabled and organized by Projekt DEAL. There has been no external funding for the study.
Author information
Authors and Affiliations
Corresponding author
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Stachon, P., Hehn, P., Wolf, D. et al. In-hospital outcomes of self-expanding and balloon-expandable transcatheter heart valves in Germany. Clin Res Cardiol 110, 1977–1982 (2021). https://doi.org/10.1007/s00392-021-01928-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00392-021-01928-6