Abstract
Background and purpose
Patients with focal cartilage lesions experience functional impairment. Results for biological treatments in the middle-aged patient is poor. Previous studies with focal prosthetic inlay resurfacing have shown a higher risk of conversion to total knee replacement at mid-term follow-up. A novel customized implant (Episealer, Episurf, Stockholm, Sweden) has been proposed to improve implant positioning and survival. The primary objective was to assess subjective-, objective function and implant survival at a minimum of five years after surgery.
Materials and methods
The inclusion criteria were patients aged 30–65 years with symptomatic focal chondral defects in the medial femoral condyle, International Cartilage Research Society grade 3 or 4 and failed conservative or surgical treatment. Minimum follow-up of 5 years. Clinical and radiologic assessments were made. Patient-reported outcome measurements at the latest follow-up were compared with the baseline data for the Knee injury and Osteoarthritis Outcome Score (KOOS), the EuroQoL (EQ-5D), the Tegner Activity Scale and a Visual Analog Scale of pain (VAS 0–10).
Results
Ten patients with the mean follow-up period of 75 months (60–86 months, SD 10) were included. Signs of osteoarthritis were seen in one patient (Ahlbäck 1). No cases with revision to knee replacement. VAS for pain and KOOS showed improvements that reached significance for VAS (p ≤ 0.001) and the KOOS subscores Pain (p = 0.01), ADL (p = 0.003), Sport and Recreation (p = 0.024) and Quality of Life (p = 0.003).
Conclusion
A good subjective outcome, a low risk of progression to degenerative changes and the need for subsequent surgery were seen at the mid-term follow-up with this customized focal knee-resurfacing implant.
Level of evidence
Prospective case series, level 4.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Participation in sport as a competitive or recreational athlete is associated with a high incidence of cartilage injuries due to traumatic or chronic repetitive damage [1, 2]. Patients with focal cartilage lesions often experience significant functional impairment, impaired quality of life and pain to the same extent as patients with severe osteoarthritis [3]. The cartilage lacks innate abilities to mount a regenerative response to injury and even a small chondral lesion could induce unicompartmental osteoarthritis [4]. The natural history of the isolated chondral defect is not completely understood, but it is clear that patients with untreated focal cartilage injuries are more prone to experience a progression of cartilage damage, eventually leading to osteoarthritis [5]. Biological treatments, such as microfracture and autologous chondrocyte implantation, have the potential for cartilage healing and pain relief in the young patient. However, the treated defects might degenerate with time and results for middle-aged and older patients are poor [6, 7]. For the active middle-aged patient with a symptomatic cartilage defect, the treatment options are few. Knee arthroplasties in this patient category run a high risk of failure [8].
Focal prosthetic inlay resurfacing has been proposed as a bridge between biological treatment and conventional joint arthroplasty [9]. A promising short-term outcome is described, but a high rate of revision to knee arthroplasty has been reported at mid-term follow-ups [10]. It has been suggested that more accurate implant positioning would enhance implant survival [11]. The development of a customized prosthesis and guide system designed precisely to fit the cartilage defect in location and size has the potential to improve implant positioning and thereby avoid damage to the opposing cartilage [12]. Two-year clinical results with this implant (Episealer, Episurf AB, Stockholm, Sweden) and follow-up with Radio Stereometric Analysis (RSA) showed no implant migration and a good subjective outcome [13]. A multicenter study with 75 patients operated on with the implant that were evaluated at a minimum of 24 months after surgery demonstrated a low failure rate of 2.5% and clinically significant improvements in pain and function scores [14]. Mid-term follow-up of 30 patients showed good implant safety and lower risk of revision surgery [15]. There is no long-term follow-up presented for this implant with full clinical and radiological assessment.
The primary objective in this study was to assess the subjective and objective outcome at a minimum of 5 years with this customized focal knee-resurfacing implant. We hypothesize that a good subjective outcome is preserved and that the risk of osteoarthritis development and the need for revision to knee arthroplasty is low.
Materials and methods
The inclusion criteria were patients aged 30–65 years with symptomatic focal chondral defects of the central medial femoral condyle, International Cartilage Research Society (ICRS) grade 3 or 4 diagnosed with MRI and verified with arthroscopy. All the patients had previously experienced the failure of conservative or surgical treatment with persistent pain and disability, such as drilling or microfracture. Patients with a BMI of > 35 kg/m2, unaddressed instability or concomitant injuries, such as meniscus injuries, apart from minor flap tears with an intact rim, signs of more general cartilage degeneration or established osteoarthritis, were excluded.
A double-coated Ti–HA monobloc Cr–Co femoral condyle implant together with specific guide instruments, manufactured from MRI data using the computer-aided design/computer-aided manufacturing (CAD/CAM) technique, was implanted (Episealer, Episurf AB, Stockholm, Sweden). The implant, surgical technique and post-op protocol have previously been described [13].
At a follow-up after a minimum of 5 years, clinical and radiologic assessments were made. Signs of effusion and reduced range of motion compared with the contralateral knee were evaluated. Standing weight-bearing radiographs were taken in the antero-posterior and lateral views and evaluated according to Ahlbäck’s classification of osteoarthritis [16]. Patient-reported outcome measurements (PROMS) at the latest follow-up were compared with the baseline and 2 year post-op data for the Knee injury and Osteoarthritis Outcome Score (KOOS), the EuroQoL (EQ-5D), the Tegner Activity Scale and a Visual Analog Scale of pain (VAS 0–10).
All the data were analyzed using IBM SPSS Statistics for Mac, version 25 (IBM Corp, Armonk, NY, USA). Data for patient demographics and patient-related outcome measurements are expressed as the mean and standard deviation or median and range depending on the category of data. Group differences were analyzed with the Mann–Whitney rank sum test, two-tailed. A p value of less than 0.05 was considered statistically significant.
The study was approved by the Ethics Committee 2012/109-3171 and 2019-03204.
Results
Ten patients, three females and seven males, fulfilled the inclusion criteria, were included after informed consent, and were all available at follow-up. The mean follow-up period was 6 years and 3 months (75 months, range 60–86 months, SD 10). All the procedures were performed on the medial femoral condyle (Table 1).
Clinical and radiologic assessment
Two patients, 3 and 5, experienced limitations in range of motion. Patient no 3 had a limitation in both extension and flexion, while patient no 5 had a slight flexion deficit (Table 1). Patient no 3 had slight hydrops at examination. No effusion was found in any of the other patients.
One patient, no 2, had a reoperation, a second-look arthroscopy, 10 months after primary surgery due to persistent anterior knee pain. The arthroscopy revealed slight patellofemoral degenerative changes, but the implant was well-fixed and no further surgery has been performed in this or any of the other patients during the follow-up period.
All the patients had normal load-bearing knee X-rays on the contralateral side. Nine patients had normal load-bearing knee X-rays on the operated side. In one patient, pat no 3 with a follow-up of 84 months, the knee X-ray was classified as Ahlbäck 1. This patient has had intermittent problems with effusion and also underwent an X-ray 48 months after index surgery that was also classified as Ahlbäck 1. No progression of osteoarthritis was thus seen between the 48- and 84-month follow-ups.
Patient-related outcome measurements
The median Tegner score was pre-op 3 (1–5), 24 months 4 (3–5) and at 75 months 4 (2–6). The improvement between pre-op and 24 months Tegner reached significance (p = 0.034). The EQ5D VAS improvement did not reach significance (Table 2). The VAS for pain decreased significantly between pre-op and the follow-up at 24 months (p < 0,001). No further reduction in pain experience was seen between 24 and 75 months and some pain still persisted at the latest follow-up (Fig. 1, Table 2).
The KOOS subscores for ADL, Sports and Quality of Life improved significantly from pre-op to 24 months [KOOS ADL pre-op mean (SD) 66 (18) vs 24 months 88 (13) p = 0.0048; Sports and Quality of life pre-op 23 (18) vs 24 months 48 (27) p = 0.034] and the improvement was maintained at the latest follow-up, without a significant increase or decrease between 24 months and the latest follow-up. The KOOS Pain score improvement did not reach significance at 24 months, but a further improvement was seen and was significant at the latest follow-up compared with pre-op [KOOS Pain, pre-op mean (SD) 60 (15) vs 75 months 85 (11) p = 0.01], No significant improvements were seen for the KOOS Symptoms score (Table 2).
Discussion
The most important finding in this study is that good improvements in subjective outcome measurements are maintained from 24 months to a follow-up after a minimum of 5 years and a mean of 75 months for this customized focal knee prosthesis. No conversion to knee arthroplasty has been necessary and in only one patient was radiographic osteoarthritis, Ahlbäck 1, noted at follow-up.
In previous studies of focal knee-resurfacing systems, a higher grade of osteoarthritis development and a higher risk of a subsequent need for total knee arthroplasty, 23%, were reported within seven years [10]. In this study, the follow-up time was slightly shorter, but progression to osteoarthritis was only noted in one patient in ten. In that case, weight-bearing X-rays were normal at the 12-month follow-up. The patient had an extra weight-bearing X-ray done at 48 months due to persistent pain and intermittent effusion that showed Ahlbäck 1 osteoarthritis, but no progression of radiologic degeneration was seen at 84 months. It is known that precise implant positioning is crucial in order not to induce stress on the opposing tibial cartilage and subsequent cartilage degeneration [17]. This customized prosthesis system with patient-specific implants and surgical guide equipment improves the potential for adequate implant positioning, which may explain why this study reports a good result and few patients with osteoarthritis at this mid-term follow-up. However, no perioperative complications were noted in the patient that progressed to osteoarthritis, no second-look arthroscopy was performed and it is not known whether this implant is correctly positioned or what the reason for the progression to osteoarthritis could be. The patient underwent previous surgery with a medial meniscus resection, described as minor, ACL reconstruction and microfracture of the cartilage injury. Careful patient selection is vital. We know that the meniscus is a crucial load-bearing structure, optimizing contact area and minimizing contact stress. The extent and part of the meniscus that is resected is of great importance. A minor flap tear that is resected is probably of limited importance, while root tears cause a loss of hoop tension and an increase in contact stresses similar to total meniscectomy [18]. The meniscus is also an important stabilizer and, in combination with cruciate ligament instability, the risk of developing knee osteoarthritis increases substantially [19, 20]. It is likely crucial to be careful about patient selection and to avoid other risk factors for osteoarthritis, apart from the cartilage injury, when advising the patient to undergo surgery with a focal knee prosthesis. The good results in this study could also be due to caution in patient selection.
The subjective outcome scores improved substantially from pre-operatively to the 2 year follow-up and this improvement was maintained at the latest follow-up at a mean of 75 months post-surgery. The longevity of the prosthesis can therefore be assumed to be good, but it should be noted that some residual pain was still present at the final follow-up. Despite good range of motion, no swelling and no radiologic signs of degenerative changes, some subjective impairment was experienced and this is important to bear in mind when counseling patients. On the other hand, these patients were selected for surgery due to pronounced pain and functional impairment and previous studies of focal cartilage injuries have shown impaired quality of life comparable to that of the severe osteoarthritis in patients on the waiting list for a total knee arthroplasty [3]. Previous biological treatment and rehabilitation were tried and there are few other options for this group of patients with highly symptomatic cartilage injuries. The ways of managing patients who present with failed attempts at the biological treatment of cartilage injuries are not well described in the literature [21]. The symptoms often worsen with time and the degeneration progresses [5].
The main limitations in this study are the small number of well-selected patients and it is not possible from this or other studies of focal knee resurfacing to foresee how the risk for long-term development of osteoarthritis will evolve. But however, even if it is only regarded as a bridge between biological treatment and conventional knee arthroplasty, we can conclude that surgery has the potential to give patients significant pain relief, functional improvement and an increased perception of quality of life for several years after surgery. In the event of failure, the method does not compromise future arthroplasty surgery, as seen in other studies of focal knee resurfacing [10].
Conclusion
A good subjective outcome, a low risk of progression to degenerative changes and the need for subsequent surgery were seen at the mid-term follow-up with this customized focal knee-resurfacing implant for medial femoral cartilage injuries.
References
Flanigan DC, Harris JD, Trinh TQ, Siston RA, Brophy RH (2010) Prevalence of chondral defects in athletes’ knees: a systematic review. Med Sci Sports Exerc 42(10):1795–1801
Widuchowski W, Widuchowski J, Trzaska T (2007) Articular cartilage defects: study of 25,124 knee arthroscopies. Knee 14(3):177–182
Heir S, Nerhus TK, Rotterud JH, Loken S, Ekeland A, Engebretsen L et al (2010) Focal cartilage defects in the knee impair quality of life as much as severe osteoarthritis: a comparison of knee injury and osteoarthritis outcome score in 4 patient categories scheduled for knee surgery. Am J Sports Med 38(2):231–237
Schinhan M, Gruber M, Vavken P, Dorotka R, Samouh L, Chiari C et al (2012) Critical-size defect induces unicompartmental osteoarthritis in a stable ovine knee. J Orthop Res 30(2):214–220
Houck DA, Kraeutler MJ, Belk JW, Frank RM, McCarty EC, Bravman JT (2018) Do focal chondral defects of the knee increase the risk for progression to osteoarthritis? A review of the literature. Orthop J Sports Med 6(10):2325967118801931
Knutsen G, Drogset JO, Engebretsen L, Grontvedt T, Ludvigsen TC, Loken S et al (2016) A randomized multicenter trial comparing autologous chondrocyte implantation with microfracture: long-term follow-up at 14 to 15 years. J Bone Joint Surg Am 98(16):1332–1339
Kreuz PC, Erggelet C, Steinwachs MR, Krause SJ, Lahm A, Niemeyer P et al (2006) Is microfracture of chondral defects in the knee associated with different results in patients aged 40 years or younger? Arthroscopy 22(11):1180–1186
Meehan JP, Danielsen B, Kim SH, Jamali AA, White RH (2014) Younger age is associated with a higher risk of early periprosthetic joint infection and aseptic mechanical failure after total knee arthroplasty. J Bone Joint Surg Am 96(7):529–535
Bollars P, Bosquet M, Vandekerckhove B, Hardeman F, Bellemans J (2012) Prosthetic inlay resurfacing for the treatment of focal, full thickness cartilage defects of the femoral condyle: a bridge between biologics and conventional arthroplasty. Knee Surg Sports Traumatol Arthrosc 20(9):1753–1759
Laursen JO, Lind M (2017) Treatment of full-thickness femoral cartilage lesions using condyle resurfacing prosthesis. Knee Surg Sports Traumatol Arthrosc 25(3):746–751
Martinez-Carranza N, Berg HE, Hultenby K, Nurmi-Sandh H, Ryd L, Lagerstedt AS (2013) Focal knee resurfacing and effects of surgical precision on opposing cartilage. A pilot study on 12 sheep. Osteoarthritis Cartilage 21(5):739–745
Martinez-Carranza N, Ryd L, Hultenby K, Hedlund H, Nurmi-Sandh H, Lagerstedt AS et al (2016) Treatment of full thickness focal cartilage lesions with a metallic resurfacing implant in a sheep animal model, 1 year evaluation. Osteoarthritis Cartilage 24(3):484–493
Stalman A, Skoldenberg O, Martinez-Carranza N, Roberts D, Hogstrom M, Ryd L (2018) No implant migration and good subjective outcome of a novel customized femoral resurfacing metal implant for focal chondral lesions. Knee Surg Sports Traumatol Arthrosc 26(7):2196–2204
Holz J, Spalding T, Boutefnouchet T, Emans P, Eriksson K, Brittberg M et al (2020) Patient-specific metal implants for focal chondral and osteochondral lesions in the knee; excellent clinical results at 2 years. Knee Surg Sports Traumatol Arthrosc. https://doi.org/10.1007/s00167-020-06289-7
Martinez-Carranza N, Rockborn P, Roberts D, Hogstrom M, Stalman A (2020) Successful treatment of femoral chondral lesions with a novel customized metal implant at midterm follow-up. Cartilage. https://doi.org/10.1177/1947603520967064
Ahlback S (1968) Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Stockh) Suppl277:7–72
Becher C, Huber R, Thermann H, Paessler HH, Skrbensky G (2008) Effects of a contoured articular prosthetic device on tibiofemoral peak contact pressure: a biomechanical study. Knee Surg Sports Traumatol Arthrosc 16(1):56–63
Lee SJ, Aadalen KJ, Malaviya P, Lorenz EP, Hayden JK, Farr J et al (2006) Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee. Am J Sports Med 34(8):1334–1344
Chen L, Linde-Rosen M, Hwang SC, Zhou J, Xie Q, Smolinski P et al (2015) The effect of medial meniscal horn injury on knee stability. Knee Surg Sports Traumatol Arthrosc 23(1):126–131
Wang LJ, Zeng N, Yan ZP, Li JT, Ni GX (2020) Post-traumatic osteoarthritis following ACL injury. Arthritis Res Ther 22(1):57
Chahal J, Thiel GV, Hussey K, Cole BJ (2013) Managing the patient with failed cartilage restoration. Sports Med Arthrosc Rev 21(2):62–68
Funding
Open access funding provided by Karolinska Institute. AS has received research funding from Episurf AB.
Author information
Authors and Affiliations
Contributions
NMC, DR, MH and AS performed the inclusion of patients and surgery. MAB made the clinical examination at the last follow-up. All the authors have read and participated in the data analysis and writing of this article.
Corresponding author
Ethics declarations
Conflict of interest
MAB, NMC, DR and MH report no conflicts of interest.
Ethical approval
2012/109-3171 and 2019-03204.
Informed consent
The study was conducted according to the declaration of Helsinki. Informed consent was obtained.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Al-Bayati, M., Martinez-Carranza, N., Roberts, D. et al. Good subjective outcome and low risk of revision surgery with a novel customized metal implant for focal femoral chondral lesions at a follow-up after a minimum of 5 years. Arch Orthop Trauma Surg 142, 2887–2892 (2022). https://doi.org/10.1007/s00402-021-04160-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-021-04160-z