Abstract
Background
Impaired gait plays an important role for quality of life in patients with Huntington’s disease (HD). Measuring objective gait parameters in HD might provide an unbiased assessment of motor deficits in order to determine potential beneficial effects of future treatments.
Objective
To objectively identify characteristic features of gait in HD patients using sensor-based gait analysis. Particularly, gait parameters were correlated to the Unified Huntington’s Disease Rating Scale, total motor score (TMS), and total functional capacity (TFC).
Methods
Patients with manifest HD at two German sites (n = 43) were included and clinically assessed during their annual ENROLL-HD visit. In addition, patients with HD and a cohort of age- and gender-matched controls performed a defined gait test (4 × 10 m walk). Gait patterns were recorded by inertial sensors attached to both shoes. Machine learning algorithms were applied to calculate spatio-temporal gait parameters and gait variability expressed as coefficient of variance (CV).
Results
Stride length (− 15%) and gait velocity (− 19%) were reduced, while stride (+ 7%) and stance time (+ 2%) were increased in patients with HD. However, parameters reflecting gait variability were substantially altered in HD patients (+ 17% stride length CV up to + 41% stride time CV with largest effect size) and showed strong correlations to TMS and TFC (0.416 ≤ rSp ≤ 0.690). Objective gait variability parameters correlated with disease stage based upon TFC.
Conclusions
Sensor-based gait variability parameters were identified as clinically most relevant digital biomarker for gait impairment in HD. Altered gait variability represents characteristic irregularity of gait in HD and reflects disease severity.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Huntington’s disease (HD) is an autosomal-dominant, neurodegenerative disease characterized by the triad of motor deficits, cognitive decline, and neurobehavioral symptoms [1]. In particular, gait impairment plays an important role upon motor functioning as it affects the quality of life, limits the independence of patients with HD, and reduces activities of daily living [2]. From a biomechanical viewpoint, gait is a well-defined movement in humans including regular, cyclic-repetitive sequences [3] making it an ideal kinetic process to be analyzed by instrumented measures. In one of the initial detailed descriptions of HD, Osler noted a “curious irregular gait” [4] without specifying the HD gait irregularity in detail. Measuring gait parameters in patients with HD supports a quantitative and unbiased assessment of motor deficits and provides objective measures to quantify potential beneficial effects of future treatments. Objective gait parameters may provide metric, granular information complementing the Unified Huntington’s disease Rating Scale total motor score (TMS), and total functional capacity (TFC) as established instruments in daily clinical routine evaluating motor impairment and functionality in HD [5].
Irregularity of gait in HD may be evaluated by using objective measures from instrumented gait analysis systems that are able to calculate stride-by-stride variance, in contrast to, e.g. stopwatch measures focusing on mean values. It has been shown that patients with HD walk slower and with smaller steps compared to healthy controls [6,7,8]. Recent studies using instrumented carpets or 3d motion capture reported results indicating correlations between UHDRS TMS and stride length in a small cohort (n = 7) [9] and significant angular changes of the gait cycle (n = 30) [10]. Gait variability as a measure of regularity of gait and dynamic postural control seems to be increased in HD [8, 9, 11, 12]. However, these monocentric studies should be interpreted with caution due to small cohorts examined.
Wearable sensors (accelerometers and gyroscopes) combined with machine learning algorithms have shown to provide objective, granular measures that support the rather rater- and time-dependent clinical ratings in neurologic diseases such as Parkinson’s disease [13,14,15,16]. Moreover, inertial sensors have the potential to be used in long-term monitoring scenarios at the patients’ home under real-life conditions with the advantage to record gait patterns over several hours instead of very short-lasting periods during an outpatient visit [17,18,19]. In HD, it has been shown that accelerometer-based sensors differentiate between pre-manifest and manifest HD patients in a cohort of 14 subjects [6]. In particular, sensor-derived velocity, step and stride length were reduced in manifest HD patients. Moreover, machine learning algorithms provide a framework for gait classification to distinguish HD patients from healthy controls [20]. These mobile sensor technologies combined with intelligent algorithms may support the diagnostic workup. However, the clinical relevance of objective parameters provided by wearable systems in comparison to data gained in well-established clinical scores as UHDRS TMS and TFC of HD patients has not been evaluated so far. Furthermore, gait characteristics in HD, particularly irregularity of gait, need to be understood in more depth by clinical validation. The identification of objective sensor-based gait parameters most characteristic for HD gait and reflecting disease severity is still pending.
To address these questions, the aim of the present two-center approach was to objectively assess characteristic features of gait in 43 HD patients compared to age- and gender-matched controls using mobile sensor-based gait analysis. In particular, these gait parameters were correlated to the clinical scores TMS and TFC in order to understand whether objective measures reflect disease severity assessed by clinical rating scales.
Subjects and methods
Fifty patients with manifest HD were enrolled at two German sites, the Department of Molecular Neurology at the University Hospital Erlangen and the George-Huntington Institute (GHI) GmbH, Münster. HD patients received standardized clinical assessments during their annual Enroll-HD visit including UHDRS-TMS and TFC. Enroll-HD is a worldwide observational study monitoring symptoms and disease progression over time in manifested HD patients or patients at-risk (www.enroll-hd.org). In addition, patients with HD and a cohort of age- and gender matched healthy controls performed a standardized 4 × 10 m walk test [21]. In order to investigate HD patients with manifest motor symptoms solely (TMS > 5), HD patients with TMS ≤ 5 (absence of motor symptoms) were excluded (n = 5), two datasets failed due to technical reasons. Thus, 43 datasets were analyzed and compared to 43 controls (Table 1). In 40 HD patients, genetic testing revealed increased Cytosin, Adenin and Guanin (CAG)-trinucleotide expansion. In the remaining patients (n = 3), clinically manifest HD symptoms and positive family history were present; however, genetic testing was not performed.
Gait characteristics were evaluated in a standardized gait test using an instrumented, sensor-based gait analysis system. This system consists of wearable SHIMMER sensors (Shimmer Research Ltd., Dublin, Ireland) laterally attached to the posterior portion of both shoes (Supplementary Figure S1) [22]. Gait signals were recorded within a (tri-axial) accelerometer range of ± 6 g (sensitivity 300 mV/g), a gyroscope range of ± 500°/sec (sensitivity 2 mV/degree/sec), and a sampling rate of 102.4 Hz. Sensor signals were transmitted to a tablet computer via Bluetooth® and stored for subsequent data analysis [13, 23]. Machine learning algorithms were applied to calculate spatio-temporal gait parameters as mean per stride values derived from 4 × 10 m gait tests (e.g. stride length, gait velocity) [21, 24]. Gait variability as a measure of stride-by-stride variance is presented as the coefficient of variance (CV) of each parameter using an average of 40 strides per patient. Participants performed a standardized 4 × 10 m overground gait test on a 10 m-long corridor at both study sites in self-selected walking speed and without stops at turning points. Only straight strides were automatically detected by the stride detection algorithm [21] and used for gait parameter calculations as described [24].
The study was approved by the local ethics committees (IRB-No. 4208, 21.04.2010, amendment approved 06.02.2017, Medical Faculty, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Germany, and IRB-No. 2017-079-f-S, 05.07.2017, Medical Council Westfalen-Lippe and Westfälische Wilhelms-Universität Münster, Germany). All participants signed the written informed consent according to the Declaration of Helsinki.
Statistical analysis
Normality of data was tested by Shapiro–Wilk test and variance homogeneity by Levene test. Mann–Whitney U test was used to verify group differences regarding anthropometric variables (age, weight, and height). Gender differences between groups were evaluated using Chi-squared test. Since gait parameters were not distributed normally, Mann–Whitney U test and Kruskal–Wallis test (for group comparisons with TFC) were used to identify group differences in gait characteristics. Kruskal–Wallis test was followed by Dunn-Bonferroni post-hoc tests in order to analyze separate differences between the groups. Besides p values (significance level α = 0.05), Cohens d is presented as measure of effect size. Correlation analysis between gait parameters and clinical scores (UHDRS TMS and TFC) was performed using Spearman’s rank correlation (rSp). Moreover, gait characteristics were compared in TFC groups based on a previously described classification [25]. TFC scores 11–13 were grouped in stage I (early), 7–10 stage II (moderate), and 0–6 stage III (advanced). Due to small sample sizes in severely affected HD patients (TFC scores 1–2 and 0), patients with TFC scores from 0 to 6 were combined in one category (III).
Results
Between-group differences in gait parameters
Specific gait parameters such as stride length (mean ± SD; HD: 1.30 ± 0.25 m, controls: 1.52 ± 0.12 m, delta Δ = − 15%, p < 0.000) and gait velocity (HD: 1.20 ± 0.29 m/s, controls: 1.48 ± 0.16 m/s, Δ = − 19%, p < 0.000) were severely reduced, as expected. Stride time (HD: 1.11 ± 0.15 s, controls: 1.03 ± 0.08 s, Δ = + 7%, p = 0.008) and stance time (HD: 64.5 ± 2.55%, controls: 63.4 ± 1.16%, Δ = + 2%, p = 0.045) were significantly increased in patients with HD compared to controls (Fig. 1).
Group differences for parameters representing irregularity of gait were more pronounced in HD in comparison to controls: stride time CV (HD: 4.46 ± 1.55%, controls: 2.80 ± 0.81%, Δ = + 37%, p < 0.000), swing time CV (HD: 5.59 ± 2.51%, controls: 3.28 ± 1.43%, Δ = + 41%, p < 0.000), stance time CV (HD: 3.06 ± 1.26%, controls: 1.91 ± 0.91%, Δ = + 38%, p < 0.000), stride length CV (HD: 7.96 ± 2.13%, controls: 6.59 ± 3.08%, Δ = + 17%, p = 0.001), and gait velocity CV (HD: 8.79 ± 2.43%, controls: 7.39 ± 2.84%, Δ = + 16%, p = 0.001) (Fig. 2). Cohen’s d effect sizes showed the largest differences between groups for the gait variability parameter stride time CV (Cohen’s d = 1.345), followed by swing time CV (d = 1.129), and stance time CV (d = 1.040). The effect size for stride length (d = 1.149) and gait velocity (d = 1.212) was strong but did not reach those of stride time CV (Supplementary Table T1).
Correlation analysis between gait parameters and clinical scores
Parameters representing gait variability showed moderate to strong correlations to UHDRS TMS: stride time CV (rSp = 0.676, p ≤ 0.000), stance time CV (rSp = 0.690, p ≤ 0.000), swing time CV (rSp = 0.595, p ≤ 0.000), stride length CV (rSp = 0.416, p = 0.006), and gait velocity CV (rSp = 0.579, p ≤ 0.000). Stride length and gait velocity showed moderate inverse correlations to UHDRS TMS: stride length (rSp = − 0.549, p ≤ 0.000), and gait velocity (rSp = − 0.478, p = 0.001).
Furthermore, the objective gait variability measures reflected the patients’ functional abilities according to TFC by moderate inverse correlations: stride time CV (rSp = − 0.555, p ≤ 0.000), stance time CV (rSp = − 0.521, p ≤ 0.000), swing time CV (rSp = − 0.561, p ≤ 0.000), stride length CV (rSp = − 0.468, p = 0.002), and gait velocity CV (rSp = − 0.628, p ≤ 0.000). Graphs to this correlation analysis are presented in Figs. 2 and 3. Group comparisons between TFC subgroups (early, moderate, advanced) revealed highly significant differences in stride time CV (p < 0.001, d = 1.601), stance time CV (p = 0.002, d = 1.214), swing time CV (p = 0.001, d = 1.347), stride length CV (p = 0.010, d = 0.935), and gait velocity CV (p < 0.000, d = 1.613). Dunn-Bonferroni post-hoc tests showed differences between the TFC subgroups for stride time CV (early vs. advanced: p < 0.000, moderate vs. advanced: p = 0.045), stance time CV (early vs. advanced: p = 0.001), swing time CV (early vs. advanced: p < 0.000), stride length CV (early vs. advanced: p = 0.008), and gait velocity CV (early vs. advanced: p < 0.000) (Fig. 3b). Importantly, stride time CV was the sole parameter detecting differences between moderate and advanced HD patients.
Discussion
The aim of this study was to objectively assess characteristic features of gait in HD patients compared to age- and gender-matched controls using mobile sensor-based gait analysis. In particular, gait parameters were correlated to clinical scores (TMS and TFC) in order to clinically validate these objective parameters. The main finding demonstrated that gait variability parameters representing the disease-characteristic irregularity of gait were the most relevant parameters correlating with TMS and TFC. Increased stride time CV in HD patients showed the largest effect size in comparison to gait of controls. Moreover, we observed severely reduced stride length and gait velocity as well as significantly increased stride time, and stance time in HD patients compared to healthy controls, albeit, with smaller effect sizes.
Gait impairment in HD
Objective gait measures of the present study showed that HD patients walk slower (− 19%) and with shorter steps (− 15%) compared to matched healthy controls. Importantly, we observed that gait variability representing the HD-characteristic irregular gait signature is substantially increased in HD patients (17–41%). Herewith, we confirm previous findings, however with mobile, sensor-based technology in comparison to stationary systems [12]. Gait variability is serving as a quantitative marker for quality of gait and falls [8, 11, 26]. With regard to stride length and gait velocity, we confirm results from previous small-cohort studies reporting motor impairment reflected by gait parameters, however with more statistical power due to larger sample sizes in our dual-center study with age- and gender-matched cohorts. Intriguingly, we confirm by applying mobile sensor-based technology that especially gait variability parameters characterize at best HD-typical gait. The largest effect size for differences between gait in HD patients and matched healthy controls was noticed for stride time CV (d = 1.345) followed by gait velocity (d = 1.212), stride length (d = 1.149), swing time CV (d = 1.129), and stance time CV (d = 1.040). These results suggest that gait parameters derived from sensor-based gait analysis serve as an objective, digital biomarker for gait patterns in HD. In particular, increased gait variability appeared to be characteristic for HD patients. This finding is in line with previous studies showing increased movement variability of the upper extremity by investigating finger tapping, and grasp force in HD [27,28,29,30]. Grip force variability is discussed as an objective measure to evaluate motor deficits and reflect disease progression in HD [31]. Our results identify gait variability as a disease-characteristic signature and an important digital biomarker in terms of gait dysfunction in HD patients, similar to grip force variability as an objective and quantitative outcome for motor deficits in the upper extremity. In a small longitudinal study with ten pre-manifest gene carriers, gait variability has increased within the first year from baseline and may be a likely marker for disease progression [32]. Future studies should further investigate sensor-based gait variability parameters longitudinally in order to determine whether this measure may be an appropriate progression marker for HD. In addition, gait variability should be investigated in premanifest HD patients in order to evaluate this measure as potential early-detection marker for clinical symptoms. Previous work supports that it is worth investigating quantitative gait in premanifest HD patients [8].
Sensor-based gait variability parameters reflect disease severity
Gait variability parameters derived from sensor-based gait analysis strongly correlated to the established clinical motor ratings TMS and TFC. This finding indicates that CV measures are an objective mirror of the ordinal clinical motor examinations. Instrumented quantitative measures are discussed as digital biomarkers and complementary outcomes since clinical rating scales are limited due to inter- and intra-rater variability as well as rater-induced placebo effects in clinical trials [33,34,35]. A meta-analysis based on 800 patients with Parkinson’s disease and 854 healthy subjects provided evidence that a stride time variability larger than 2.4% discriminates healthy from pathological gait [36]. Sensor-based gait variability parameters were identified as very important objective measure in differentiating patients with atypical parkinsonian disorders (larger gait variability) from patients with sporadic Parkinson’s disease [22]. In HD, it has been shown that the instrumented measure of variability in grasp forces strongly correlated with motor performance assessed by TFC (r = − 0.712) and TMS (r = 0.841) suggesting that movement variability is a key feature of motor impairment in HD [29]. In a similar way, quantitative assessments of chorea in HD patients has shown to be feasible, easy applicable and may improve sensitivity and reliability of motor end points in clinical studies [34]. Therefore, instrumented quantitative data provide important measurements complementing established clinical ratings and may be useful for the evaluation of motor deficits in HD.
Wearable sensor system as easy-to-apply tool for objective gait assessment
We observed that wearable sensors provide metric, granular information in regard to gait impairment in HD patients. Easy-to-apply wearable systems are able to provide stride-by-stride variance parameters which have in this study been demonstrated to play an important role in HD gait. Sensor-based gait data correlated to established clinical scores and, therefore, indicates that inertial sensors are able to reflect the rating of clinical experts. This is in line with previous studies in other basal ganglia diseases like Parkinson’s disease [13,14,15] and atypical Parkinsonian disorders [16] reporting that wearable sensor systems support the clinical workup by objective, quantitative data. In HD, previous studies observed that inertial sensors are able to differentiate between HD patients and healthy controls [20]. They have been validated for the analysis of gait characteristics in HD patients by comparing spatio-temporal gait parameters derived from sensors with those from instrumented gait mats [6, 37]. In contrast to mats, future mobile sensor technology may be used in home-monitoring scenarios [17, 18] over several hours in order to provide a comprehensive and long-lasting monitoring tool complementing established short-lasting clinical examinations in the outpatient units. In a pilot study, the feasibility was shown to use wearable sensors in the hospital and in the home-environment of HD patients [38]. Future studies need to further investigate the application of inertial sensors as objective measure to detect motor impairment more precisely and outside the lab. In particular, it is interesting to record irregular movements in the upper and lower extremity of HD patients in everyday life.
Conclusion
In conclusion, our data demonstrate that sensor-based gait variability parameters were identified as the clinically most relevant digital biomarker for gait impairment in HD. They showed the largest effect size in group comparison and strongly correlated to established clinical scores (TFC, TMS). Thus, sensor-based gait variability represents the irregularity of gait characteristic for HD and reflects disease severity. Moreover, we observed reduced stride length and gait velocity as well as increased stride time and stance time in HD patients compared to age- and gender-matched controls. Our cohort-based clinical validation study confirmed the clinical relevance of a detailed and objective gait analysis in HD. As the altered sensor-based gait variability parameters of this study may mirror disease progression according to TFC, there is a strong need for longitudinal studies validating these initial findings. The transfer from cross-sectional studies to disease monitoring including long-term recordings at patients’ home and individual care should be the focus of future studies using sensor-based gait analysis.
Change history
27 March 2020
The original version of this article unfortunately contained a mistake. The name of one author is not presented correctly in the author group.
References
Walker FO (2007) Huntington’s disease. Lancet 369(9557):218–228
Kirkwood SC et al (2001) Progression of symptoms in the early and middle stages of Huntington disease. Arch Neurol 58(2):273–278
Rau G, Disselhorst-Klug C, Schmidt R (2000) Movement biomechanics goes upwards: from the leg to the arm. J Biomech 33(10):1207–1216
Osler W (1894) Case of hereditary chorea. Johns Hopkins Hosp Bull 5:119–129
Huntington Study Group (1996) Unified Huntington’s disease rating scale: reliability and consistency. Mov Disord 11(2):136–142
Dalton A et al (2013) Analysis of gait and balance through a single triaxial accelerometer in presymptomatic and symptomatic Huntington’s disease. Gait Posture 37(1):49–54
Delval A et al (2006) Role of hypokinesia and bradykinesia in gait disturbances in Huntington’s disease. J Neurol 253(1):73–80
Rao AK et al (2008) Spectrum of gait impairments in presymptomatic and symptomatic Huntington’s disease. Mov Disord 23(8):1100–1107
Pyo SJ et al (2017) Quantitative gait analysis in patients with Huntington’s disease. J Mov Disord 10(3):140–144
Mirek E et al (2017) Three-dimensional trunk and lower limbs characteristics during gait in patients with Huntington’s disease. Front Neurosci 11:566
Hausdorff JM et al (1998) Gait variability and basal ganglia disorders: Stride-to-stride variations of gait cycle timing in Parkinson’s disease and Huntington’s disease. Mov Disord 13(3):428–437
Moon Y et al (2016) Gait variability in people with neurological disorders: a systematic review and meta-analysis. Hum Mov Sci 47:197–208
Klucken J et al (2013) Unbiased and mobile gait analysis detects motor impairment in Parkinson’s disease. PLoS ONE 8(2):e56956
Schlachetzki JCM et al (2017) Wearable sensors objectively measure gait parameters in Parkinson’s disease. PLoS ONE 12(10):e0183989
Marxreiter F et al (2018) Sensor-based gait analysis of individualized improvement during apomorphine titration in Parkinson’s disease. J Neurol 265(11):2656–2665
Raccagni C et al (2018) Sensor-based gait analysis in atypical parkinsonian disorders. Brain Behav 8(6):e00977
Pasluosta CF et al (2015) An emerging era in the management of Parkinson’s disease: wearable technologies and the internet of things. IEEE J Biomed Health Inform 19(6):1873–1881
Maetzler W, Klucken J, Horne M (2016) A clinical view on the development of technology-based tools in managing Parkinson’s disease. Mov Disord 31(9):1263–1271
Espay AJ et al (2016) Technology in Parkinson’s disease: challenges and opportunities. Mov Disord 31(9):1272–1282
Mannini A et al (2016) A machine learning framework for gait classification using inertial sensors: application to elderly, post-stroke and Huntington’s disease patients. Sensors 16(1):134. https://doi.org/10.3390/s16010134
Barth J et al (2015) Stride segmentation during free walk movements using multi-dimensional subsequence dynamic time warping on inertial sensor data. Sensors (Basel) 15(3):6419–6440
Gassner H et al (2019) The diagnostic scope of sensor-based gait analysis in atypical Parkinsonism: further observations. Front Neurol 10:5
Gassner H et al (2017) Gait and cognition in Parkinson’s disease: cognitive impairment is inadequately reflected by gait performance during dual task. Front Neurol 8:550
Rampp A et al (2015) Inertial sensor-based stride parameter calculation from gait sequences in geriatric patients. IEEE Trans Biomed Eng 62(4):1089–1097
Paulsen JS et al (2010) Challenges assessing clinical endpoints in early Huntington disease. Mov Disord 25(15):2595–2603
Hausdorff JM (2007) Gait dynamics, fractals and falls: finding meaning in the stride-to-stride fluctuations of human walking. Hum Mov Sci 26(4):555–589
Bechtel N et al (2010) Tapping linked to function and structure in premanifest and symptomatic Huntington disease. Neurology 75(24):2150–2160 (e-Pub ahead of print)
Reilmann R et al (2010) Grasping premanifest Huntington’s disease—shaping new endpoints for new trials. Mov Disord 25(16):2858–2862
Gordon AM et al (2000) Coordination of prehensile forces during precision grip in Huntington’s disease. Exp Neurol 163(1):136–148
Reilmann R et al (2010) Tongue force analysis assesses motor phenotype in premanifest and symptomatic Huntington’s disease. Mov Disord 25(13):2195–2202
Reilmann R et al (2001) Objective assessment of progression in Huntington’s disease: a 3-year follow-up study. Neurology 57(5):920–924
Rao AK et al (2011) Longitudinal change in gait and motor function in pre-manifest Huntington’s disease. PLoS Curr 3:RRN1268
Reilmann R et al (2012) Huntington’s disease: objective assessment of posture—a link between motor and functional deficits. Mov Disord 27(4):555–559
Reilmann R et al (2011) Assessment of involuntary choreatic movements in Huntington’s disease—toward objective and quantitative measures. Mov Disord 26(12):2267–2273
Reilmann R, Schubert R (2017) Motor outcome measures in Huntington disease clinical trials. Handb Clin Neurol 144:209–225
König N et al (2016) Can gait signatures provide quantitative measures for aiding clinical decision-making? A systematic meta-analysis of gait variability behavior in patients with Parkinson’s disease. Front Hum Neurosci 10:319
Trojaniello D et al (2015) Comparative assessment of different methods for the estimation of gait temporal parameters using a single inertial sensor: application to elderly, post-stroke, Parkinson’s disease and Huntington’s disease subjects. Gait Posture 42(3):310–316
Andrzejewski KL et al (2016) Wearable sensors in Huntington disease: a pilot study. J Huntington’s Dis 5(2):199–206
Acknowledgements
Open Access funding provided by Projekt DEAL. The authors would like to thank all patients that participated in this study. The present work is part of the doctoral thesis of Dennis Jensen in the frame of obtaining the degree “Dr. med.” at the University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU). This study was supported by the Huntington-Stiftung of the Deutsche Huntington Hilfe e.V. We further acknowledge the Enroll-HD staff for their support and collaboration. Bjoern Eskofier gratefully acknowledges the support of the German Research Foundation (DFG) within the framework of the Heisenberg professorship programme (Grant Number ES 434/8–1).
Funding
HG, BE, JK and JW received institutional research grants from the Emerging Field Initiative of the Friedrich Alexander-University Erlangen-Nürnberg (EFI Moves, 2 Med 03), from the Bavarian State Ministry for Education, Science and the Arts, Munich, Germany (MotionLab@Home, E|Home Center), and from the Bavarian Ministry of Economic Affairs and Media, Energy and Technology, Germany (Medical Valley Award 2016, Fall Risk PD). HG, FM, RR, and ZK received an institutional research grant by the Huntington-Stiftung of the Deutsche Huntington Hilfe e.V. FM is supported by the Interdisciplinary Center for Clinical Research of the FAU, Clinician Scientist programme. HG, BE, and JK are supported by Mobilise-D from the Innovative Medicines Initiative 2 Joint Undertaking under grant agreement no. 820820. HG received support by the Medical Research Foundation at the University Hospital Erlangen outside of the submitted work. BE holds ownerships of Portabiles HealthCare Technologies GmbH and Portabiles GmbH, received compensation and honoraria from serving on scientific advisory boards for Abbvie GmbH, Adidas GmbH, Bosch Sensortec GmbH, and ST Sportservice GmbH. Further, he gratefully acknowledges the support of the German Research Foundation (DFG) within the framework of the Heisenberg professorship programme (grant number ES 434/8-1). JK holds ownerships of Portabiles HealthCare Technologies GmbH and Portabiles GmbH, received compensation and honoraria from serving on scientific advisory boards for LicherMT GmbH, Abbvie GmbH, UCB Pharma GmbH, GlaxoSmithKline GmbH & Co. KG, Athenion GmbH, and Thomashilfen GmbH; as well as lecturing from UCB Pharma GmbH, TEVA Pharma GmbH, Licher MT GmbH, Desitin GmbH, Abbvie GmbH, Solvay Pharmaceuticals, and Ever Neuro Pharma GmbH. JW reports personal fees outside of the submitted work from Desitin Arzneimittel GmbH and Biogen GmbH. ZK reports personal fees outside of the submitted work from Desitin Arzneimittel GmbH and UCB Pharma.
Author information
Authors and Affiliations
Contributions
Conception and design of the study: HG, DJ, SB, JK, RR, ZK. Execution: HG, DJ, FM, AK, SB, RS, LMM, RR, ZK. Statistical analysis: HG, DJ. Writing the first draft of the manuscript: HG, DJ. Manuscript review and critique: LMM, BE, JK, JW, RR, ZK.
Corresponding author
Ethics declarations
Conflicts of interest
DJ, AK, SB, LM, and RR declare no conflict of interest.
Ethical standards
This study has been approved by the local ethics committees in Erlangen, Germany and Münster, Germany and has, therefore, been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.
Disclosure
The study was supported and performed at the Department of Molecular Neurology (University Hospital Erlangen, Erlangen, Germany), and the George-Huntington Institute (GHI) GmbH, Münster, Germany.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gaßner, H., Jensen, D., Marxreiter, F. et al. Gait variability as digital biomarker of disease severity in Huntington’s disease. J Neurol 267, 1594–1601 (2020). https://doi.org/10.1007/s00415-020-09725-3
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00415-020-09725-3