Abstract
Background and purpose
Breast carcinoma is the most common cancer in female patients with a propensity for recurrence and metastases. The accuracy of ultrasound (US), computed tomography (CT), magnetic resonance imaging (MRI), scintimammography (SMM) and positron emission tomography (PET) in diagnosing the recurrent and/or breast cancer has never been systematically assessed, and present systematic review was aimed at this issue.
Methods
MEDLINE and EMBASE were searched for articles dealt with detection of recurrent and/or metastatic breast cancer by US, CT, MRI, SMM or PET whether interpreted with or without the use of CT. Histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were used as golden reference. We extracted data to calculate sensitivity, specificity, summary receiver operating characteristic curves and area under the curve and to test for heterogeneity.
Result
In 42 included studies, US and MRI had highest pooled specificity (0.962 and 0.929, respectively); MRI and PET had highest pooled sensitivity (0.9500 and 0.9530, respectively). The AUC of US, CT, MRI, SMM and PET was 0.9251, 0.8596, 0.9718, 0.9386 and 0.9604, respectively. Results of pairwise comparison between each modality demonstrated that AUC of MRI and PET was higher than that of US or CT, p < 0.05. No statistical significance was found between MRI and PET. There was heterogeneity among studies and evidence of publication bias.
Conclusion
In conclusion, MRI seemed to be a more useful supplement to current surveillance techniques to assess patients with suspected recurrent and/or metastatic breast cancer. If MRI shows an indeterminate or benign lesion or MRI was not applicable, FDG-PET could be performed in addition.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Breast carcinoma is the most common cancer in women in Western Europe and the United States with an incidence highest in the 40–55 age range, and its prevalence is still on the rise (Parker et al. 1997; von Fournier et al. 1993). It accounts for 40,000 and 14,000 deaths yearly in the US and UK, respectively, and that makes it the second cause of cancer death in women in those countries (Parker et al. 1997; American Cancer Society 2002; Cancer Research Campaign 1996). Despite major progress in surgical treatment, radiotherapy, and adjuvant chemotherapy protocols, tumor recurrence and metastasis have remained as a major problem in breast cancer management (Yilmaz et al. 2007). Approximately, the risk for patient of breast cancer to develop recurrence is 7–30% and to suffer distant metastases is 45–90% at some time within the course of their disease (Bongers et al. 2004). The survival of women suffering form recurrence and metastasis is strikingly different: Women with a local recurrence have a 21–36% 5-year relative survival rate (Bongers et al. 2004), while women with distant metastatic disease have a 25% 5-year relative survival rate (Isasi et al. 2005). Early detection and accurate restaging of recurrent breast cancer are important to define appropriate therapeutic strategies and increase the chances of a cure (Schmidt et al. 2008; Radan et al. 2006; Ternier et al. 2006). In addition, distant metastases are the most important prognostic factors in women with breast cancer which changes the intention of therapy from curative to palliative (Landheer et al. 2005). Thus, it is critical to detect recurrence and distant metastases in the follow-up of women with breast cancer.
According to the recommendations of the American Society of Clinical Oncology (ASCO) 2006 update of the breast cancer follow-up and management guidelines in the adjuvant setting, physical examination and mammography should be used routinely in the breast cancer surveillance. Additional imaging methods, such as chest X-ray, bone scans, liver ultrasound (US), computed tomography (CT) scans, positron emission tomography with 18F-fluoro-deoxy-glucose (FDG-PET) scans and breast magnetic resonance imaging (MRI), are not recommended (Khatcheressian et al. 2006). But physical examination and mammography have their limitations, especially for lesions situated deep in the muscle layer, some distance away from the scar or in the axilla (Rissanen et al. 1993). Furthermore, the surgery and radiotherapy could also induce deleterious changes in breast tissue (Stomper et al. 1987; Orel et al. 1992; Dershaw et al. 1992). In such cases, the reliability of the diagnosis might be complemented by the use of the recent conventional anatomic imaging modalities such as US, CT, MRI, scintimammography (SMM) or the whole-body imaging modality FDG-PET, which provides information about the metabolic activity of tumors.
Although extensive researches have been performed with regard to US, CT, MRI, SMM and FDG-PET for the detection of recurrent and metastatic breast cancer, no comprehensive comparison has yet been conducted among all the non-invasive diagnostic tools. Isasi et al. (2005) performed a meta-analysis to assess FDG-PET for the evaluation of breast cancer recurrences and metastases; however, it did not assess other important non-invasive methods—US, CT, MRI, SMM which are widely used both in surveillance and follow-up. Thus, our study aims to perform a comprehensive systematic review to obtain the overall diagnostic performance of US, CT, MRI, SMM and FDG-PET for the detection of recurrent and metastatic breast cancer on a per-patient and a per-lesion basis, which, to our knowledge, had not previously been studied.
Materials and methods
Literature search
A computer literature search as a comprehensive search (Devillé et al. 2000) of abstracts about studies in human subjects from January 1995 to August 2008 through MEDLINE and EMBASE databases was performed to identify articles about the diagnostic performance of US, CT, MRI, SMM and PET (interpreted with or without the use of CT) for the detection of recurrent and metastatic breast cancer. The following keywords were used: (“US” OR “ultrasound” OR “CT” OR “computed tomography” OR “MRI” OR “magnetic resonance imaging” OR “scintimammography” OR “SMM” OR “PET” OR “positron emission tomography” OR “FDG” OR “fluorodeoxyglucose”) AND (“breast carcinoma” OR “breast cancer” OR “carcinoma of breast” OR “breast neoplasm”) AND (“sensitivity” OR “specificity” OR “false negative” OR “false positive” OR “diagnosis” OR “detection” OR “accuracy”). The China bio-medicine databases were used for Chinese articles with the following keywords: (“US” OR “CT” OR “MRI” OR “scintimammography” OR “SMM” OR “PET” OR “FDG”) AND “breast carcinoma” (in Chinese). Other databases such as Cochrane Library, Cancerlit, and China National Knowledge Infrastructure database were also searched for relevant articles. Carefully extensive cross-checking of the reference lists of all retrieved articles was done to supplement the list of articles.
Selection of studies
The inclusion criteria were as follows: (1) full reports published in English or Chinese, (2) all articles in the published literature, (3) both retrospective and prospective articles, (4) articles dealt with the performance of US, CT, MRI, SMM and PET (alone or in combination, but not in sequence) in recurrent and metastatic breast carcinoma. (5) Only articles confirmed the diagnosis with the reference standard as histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months. (6) Only articles that present sufficient data to calculate the true-positive (TP) and false-negative (FN) values were included. (7) At least 10 patients were included in the article. (8) When data or subsets of data were presented in more than one article, the article with the most details or the most recent articles was chosen. CT studies without contrast agent were excluded. Studies using sequential test combinations (e.g., PET in patients selected on the basis of abnormal US or CT image) were excluded because the selection of patients on the basis of diagnostic test results could have unpredictably modified the estimate of the operative characteristics of the tests themselves (Sackett and Haynes 2002).
Four reviewers, who had at least 3 years work experience in the special fields of US, CT, MRI, SMM or PET, independently checked retrieved articles only in their own fields. To minimize bias in the selection of studies, one reviewer, who had more than 10 years work experience both in oncology and radiology, checked all articles. In case of discordances, a consensus re-review between all reviewers was performed.
Data extraction
Information extracted form each article included first author, study date, simple size, age of subjects, reference standard, unit of analysis (patients or lesions), technical characteristics of each imaging modality, and the number of true positives, false positives, true negatives, and false negatives. Data were extracted independently by the same four observers. Data abstraction was not blinded with regard to unnecessary information such as the authors, the authors’ affiliation, the journal name or year of publication (Berlin 1997). Disagreements were resolved in consensus.
Quality assessment
Quality Assessment of Diagnostic Accuracy Studies (QUADAS) criteria were used to assess the quality of every article (Whiting et al. 2003). The following data were extracted to perform accuracy analyses: (1) clinical characteristics of the study sample described (age, sex, number of patients enrolled, reason for performing particular imaging modality); (2) patient selection (consecutive or not); (3) study type (prospective, retrospective or unknown); (4) independence of test interpretation (blinded or not); (5) verification bias (no bias, limited or considerable: i.e., no bias means all patients or lesions were confirmed by histopathologic analysis; considerable verification bias means only a small number of patients or lesions were confirmed by histopathologic analysis; others were referred to as limited verifications bias).
The following features were also included: As to US, type of probe, probe frequency (MHz) and type of scanning were included. As to CT, the type of scanner (non-helical or helical), section thickness, or use of contrast agent or not were included. And as to MRI imaging, magnetic field strength, type of coil, use of contrast agent or not were included. As to SMM, scanner, contrast agent, contrast dose, collimator were included. As to FDG-PET, amount of tracer, camera model, resolution, attenuation correction and type of analysis (qualitative or quantitative or both) were included. The numbers of TP, FN, false-positive (FP) and true-negative (TN) results in the detection of recurrent and/or metastatic breast cancer were extracted on a per-patient or per-lesion.
Statistical analysis
A random effect model (Fleiss et al. 2003) was used for the primary meta-analysis to obtain a summary estimate for sensitivity and specificity with 95% confidence intervals (CI) of each non-invasive technique. We also calculated summary receiver operating characteristic (SROC) curves and the area under the curve (AUC). In a meta-analysis, each separate study contributes an estimate of true-positive rates (TPR) and false-positive rates (FPR). A graph is made from the TPR and FPR points. The SROC curve is placed over the points to form a smoothed curve which can be achieved using a regression model proposed by Moses et al. (1993). And then, we did Z test to find whether the sensitivity (SE), specificity (SP) and AUC of each modality was significantly different from others or not, if p < 0.05 was considered as statistically significant. All the statistics (sensitivity, specificity, PPV, negative predictive value (NPV), accuracy, SROC, AUC) refer to recurrence and surveillance.
We tested the following items: threshold effects between studies (Deeks 2001) using Spearman correlation coefficients ρ (the cutoff effect was considered present in the case of a ρ value > 0.4; Devillé et al. 2002); heterogeneity using the likelihood ratio χ 2 test (if p < 0.05 was considered having apparent heterogeneity; Fleiss et al. 2003) and I 2 index which is a measure of the percentage of total variation across studies due to heterogeneity beyond chance and takes values between 0 and 100%. Its values over 50% indicate heterogeneity (Huedo-Medina et al. 2006). Publication bias was assessed by funnel plots. Since data on US, CT, MRI or FDG-PET imaging were limited, we did not perform subgroup analyses.
All of the statistical analyses were undertaken using SAS statistical software version 8.2 (SAS Institute Inc., Cary, NC, USA) and Meta-DiSc (Version 1.4) (Zamora et al. 2006). (Meta-DiSc, produced by Javier.zamora, is freeware software to perform systematic review of studies of evaluation of diagnostic and screening tests.)
Results
Literature search and study design characteristics
The computerized search yielded 1,017 primary studies, of which 969 were excluded. The reasons for exclusion were as follows: (a) the aim of the articles was not to reveal the diagnostic value of US, CT, MRI, SMM, FDG-PET (with or without CT) for identification and characterization of recurrent or metastatic breast cancer (n = 817); (b) the reference standard was not used as histopathologic analysis or close clinical and imaging follow-up for at least 6 months (n = 79); (c) data from the article that could be used to construct or calculate TP, FP, TN and FN (n = 39); (d) data from the article come from a combination of different imaging modalities that could not be differentiated for assessment of single tests (n = 32); (e) article was printed more than once, article with smaller population was excluded (n = 2); (f) article that cannot be accessible (n = 3); (g) data included less than 10 patients (n = 3). A total of 43 studies (Yilmaz et al. 2007; Bongers et al. 2004; Schmidt et al. 2008; Radan et al. 2006; Ternier et al. 2006; Rissanen et al. 1993; Bruneton et al. 1986; Lee et al. 1993; Gilles et al. 1993; Dehdashti et al. 1995; Melani et al. 1995; Hagay et al. 1996; Winehouse et al. 1999; Rieber et al. 1997; Drew et al. 1998; Muüller et al. 1998; Moon et al. 1998; Cwikla et al. 1998; Hathaway et al. 1999; Qayyum et al. 2000; Stuhrmann et al. 2000; Bäz et al. 2000; Eubank et al. 2001, 2004; Kim et al. 2001; Belli et al. 2002; Liu et al. 2002; Goerres et al. 2003; Suárez et al. 2002; Kamel et al. 2003; Gallowitsch et al. 2003; Siggelkow et al. 2003; De Cicco et al. 2004; Shin et al. 2005; Weir et al. 2005; Lamuraglia et al. 2005; Preda et al. 2006; Wolfort et al. 2006; Piperkova et al. 2007; Rajkovaca et al. 2007; Usmani et al. 2007; Haug et al. 2007; Riebe et al. 2007) fulfilled all of the inclusion criteria and were considered for the analysis (Table 1). 15 studies were prospective, 16 studies were retrospective, and the remaining was not defined. Patient selection was consecutive in 18 studies and not defined in 25. 11 studies took only histopathologic analysis as reference standard, indicating a complete verification and lack of bias, while 10 studies showed limited verification bias and 22 studies still showed considerable verification bias. TP, FN, FP, TN results and some features of each modality were shown in Tables 2, 3, 4, 5 and 6.
Publication bias, heterogeneity and cutoff effect
To assess a possible publication bias, scatter plots were designed using the log diagnostic odd ratios (DORs) of individual studies against their sample size. The funnel plot of US, CT, MRI, SMM and PET was given in Fig. 1. In detail, the US, CT, MRI, SMM and PET showed marked asymmetry (with small studies missing from the bottom left quadrant, thus suggesting a publication bias). There was heterogeneity for most non-invasive modalities except SMM and PET, which confirmed either by likelihood ratio χ 2 test or I 2 index (Table 7). There was no conclusive evidence of a cutoff effect for US and PET to Spearman correlation coefficients (ρ < 0.4). But a cutoff effect was present for CT, MRI and SMM (ρ > 0.4; Table 8).
Pooled sensitivity, pooled specificity and DORs
On the basis of a random effect model, pooled sensitivity, pooled specificity and DOR of those non-invasive modalities were shown in Table 9. Pooled sensitivity of MRI and PET (with or without CT) was 0.9500 and 0.9530, respectively, no statistical significant difference was found between MRI and PET (p > 0.05). However, they had highest pooled sensitivity, p < 0.05, when compared with US, CT and SMM. Pooled specificity of US and MRI was 0.962 and 0.929, respectively, no statistical significant difference was found between US and MRI (p > 0.05). However, they had highest pooled specificity, p < 0.05, when compared with CT, SMM and PET. The DOR estimates for MRI and PET were 131.78 (95% CI 70.9310–244.8100) and 106.88 (95% CI 68.1040–167.73), respectively, and were significantly higher than for US, CT and SMM (p < 0.05). The results were also shown in Table 9.
Summary ROC curves, AUC and the Q* index
Summary receiver operating characteristic analysis was used to compare those non-invasive modalities. The AUC of US, CT, MRI, SMM and PET (with or without CT) was presented in Table 8. AUC of MRI and PET (with or without CT) is 0.9718 and 0.9604, respectively; however, no significant difference was found between those two modalities, p > 0.05. Results of pairwise comparison between each modality demonstrated that AUC of both MRI and PET (with or without CT) was higher than that of US or CT, p < 0.05. AUC of SMM was 0.9386, no statistical significance was found when compared with that of MRI and PET (with or without CT), p > 0.05. In terms of its AUC, there was still no statistical significance between CT and US, p > 0.05. The Q* index estimates for US, CT, MRI, SMM and PET (with or without CT) were 0.8593, 0.7904, 0.9228, 0.8757 and 0.9051, respectively. Like AUC, the Q* index estimates for MRI and PET were significantly higher than for US, CT and SMM, p < 0.05. And, they were similar for MRI and PET (Table 9; Fig 2).
Discussion
Soerjomataram et al. (2008) conducted a review to summarize available knowledge on the determinants of survival 10 years or more after breast cancer diagnosis and found that patients with recurrent metastasized or second cancer generally exhibited lower long-term survival than those without. Locoregional recurrences predominately affect the breast, skin, the axillary and supraclavicular nodes and the chest wall. Internal mammary (IM), mediastinal nodes, pleura and lung parenchyma are the most common sites of intrathoracic recurrence after primary surgical resection (Fisher et al. 2001; Hatteville et al. 2002). Extrathoracic recurrence often occurs in bone, liver and brain. The correct identification of local recurrences and distant metastases at the time of suggestive symptoms in the follow-up for breast cancer prompts clinical consideration for administering different therapies (Nomura et al. 1999; Wapnir et al. 2006). Thus, it is crucial for patients with breast cancer to early detect recurrences or metastases (Eubank et al. 2002; Kamby et al. 1988; Yang et al. 2007; Siggelkow et al. 2004). This meta-analysis focused on evaluating the diagnostic ability of US, CT, MRI, SMM and PET (interpreted with or without the use of CT), which are the widely used non-invasive modalities for the detection of recurrent and/or metastatic breast cancer.
Previous studies have discussed the diagnosis ability of US in detecting recurrent and/or metastatic breast cancer. Lamuraglia et al. (2005) determined the efficacy of Doppler US with contrast agent (DUPC) in local recurrent breast cancer, revealed a SE of 67% and a SP of 100%. Eubank et al. (2001) evaluated the benefit of echo-contrast-enhanced Doppler sonography the differentiation of benign versus malignant breast lesions in 38 patients who had surgical removal of a malignant breast mass. The baseline ultrasound examination showed an SE of 50% and an SP of 86%, after contrast enhancement the ultrasound findings demonstrated an SE of 100% and an SP of 96%. In conclusion of their findings, it suggests that contrast-enhanced sonography aids in the differentiation of local recurrence from benign scar lesions. Therefore, US may be most useful when abnormal, but normal values cannot exclude the presence of active disease.
CT imaging, by virtue of its cross-sectional display, is widely used in recent years. However, reports in the literature differ with regard to diagnostic accuracy of CT imaging in detecting recurrent and/or metastatic breast cancer, ranging from 40 to 92% and from 41 to 100% for SE and SP, respectively (Radan et al. 2006; Ternier et al. 2006; Winehouse et al. 1999; Bäz et al. 2000; Gallowitsch et al. 2003; Piperkova et al. 2007; Riebe et al. 2007; Armington et al. 1987). Recently, CT has been the main modality used to evaluate mediastinal nodes in oncology, but as this technique uses size as the main criterion to assess nodal status, it is limited by poor SE. Landheer et al. (2005) also found that metastatic lymph nodes are often not identified by CT, and those smaller than 1 cm are often described as non-pathological. Due to their small size and anatomical position, it is difficult to confirm a pathological diagnosis. Moskovic et al. (1992) found that the detection rate of CT of breast cancer recurrence in patients without a palpable axillary mass is extremely low and they suggested that this technique unjustified screening for clinically occult axillary disease in patients with arm symptoms following axillary surgery or radiation therapy for breast cancer. Similarly, Armington et al. (1987) demonstrated that 11 of 30 patients with axillary and supraclavicular lesions were missed because of inadequate visualization of the axillary apex with CT imaging. To date, early detection of metastases by repeated conventional imaging tests (CT, ultrasound, and bone scintigraphy) has not been shown to be of benefit over routine follow-up in terms of patient survival (McLoud et al. 1992; Webb et al. 1991).
Previous studies have demonstrated that the contrast-enhanced MRI imaging of the breast has been a sensitive modality for the detection of breast tumor recurrence, with a SE of nearly 100%, and this has become one of the most common indications for the examination (Kneeland et al. 1987; de Verdier et al. 1993; Bilbey et al. 1994; The GIVIO Investigators 1994). Preda et al. (2006) investigated 93 consecutive patients with breast cancer; the SE, SP, and NPV of MRI for the diagnoses of recurrent breast cancer were 93.8, 90, and 98.8%, respectively. The NPV of MRI, which indicates a very low likelihood of new malignancy if MRI defines the lesion as benign, is impressingly high. And, Preda suggests that lesions graded by MRI as Fisher I–II (BI-RADS I–II) can be safely monitored with the usual yearly follow-up. A repeat MRI examination after 6 months is recommended for lesions graded as Fischer III (BI-RADS III), if there is no clinical suspicion of recurrence before 6 months. For lesions graded higher than Fischer IV (BI-RADS IV), further cytological or histological evaluation is mandatory. This result is in line with previous result provided by Heywang-Köbrunner (et al. 1993), with a NPV of 100%. Schmidt et al. (2008) compared the performance in recurrent breast cancer patients using FDG-PET/CT and whole-body MRI and found that whole-body MRI showed a higher diagnostic accuracy of 94 versus 90% for FDG-PET/CT. In our study, we synthesized the currently available information of MRI in detecting recurrent and/or metastatic breast cancer, and found that the pooled sensitivity, pooled specificity and AUC are 0.9500, 0.929 and 0.9718, respectively. On the basis of current evidences, the overall diagnostic ability of MRI and PET was similar; however, MRI had the advantage that it had excellent contrast in soft tissue and parenchymal structures and the larger anatomical coverage compared to PET/CT (skull base to proximal femurs).
SMM is the method by which breast pathology is identified using a radiopharmaceutical. The agent used can be tumor specific such as 99m Tc-sestamibi (99mTc-MIBI) or a non-specific tracer such as 99mTc-methylene diphosphonate (99mTc-MDP) and Thallium-201. Several clinical studies have reported that 99mTc-MIBI SMM is accurate in differentiating palpable breast lesions, and the utility of the technique has been emphasized in decreasing the number of breast biopsies (Landheer et al. 2005; Kao et al. 1994). Although multi-center trials had been done, SMM has not been widely adopted to resolve cases that are equivocal by mammography (Khalkhali et al. 1995; Tolmos et al. 1998). The major problem is the lower SE of SMM for non-palpable tumor. Tiling et al. (1998) made a meta-analysis and showed that SMM may be useful in recurrent breast cancer because post-surgical or post-radiotherapy changes made anatomical methods of imaging of limited use. But due to the number of patients studied was rather small, SMM cannot be recommended for detection of recurrent and/or metastatic breast cancer.
PET with radiolabeled glucose analog FDG is a method that is based on the increased glucose metabolism of malignant tumors. It can reveal the functional information that even the most exquisitely detailed anatomic image cannot provide. FDG-PET seems to have reasonable sensitivity and specificity in the detection of recurrent and metastatic breast cancer, particularly in the subset of patients presenting with elevated tumor markers (Aide et al. 2007). Suárez et al. (2002) reported that patients with CA153 blood levels above 60 U/ml were always associated with positive PET, while CA153 blood levels below 50 U/ml were always associated with negative one. Liu et al. (2002) got the similar results, the diagnostic SE and accuracy of FDG-PET in patients with suspected recurrent breast cancer and asymptomatically elevated tumor markers were 96 and 90%. When compared to CT and MRI, PET was shown to be superior in the detection of mediastinal and IM node metastases (Eubank et al. 2001; Goerres et al. 2003). As for bone scintigraphy, PET had also been shown to be superior in detecting bone metastases (Kao et al. 2000).
PET–CT is a full-ring-detector clinical PET scanner combined with a multi-detector row helical CT scanner, which allows contemporaneous and co-registered acquisition of both PET and CT images (Fueger et al. 2005). In a retrospective review of 75 patients with suspected breast cancer, Tatsumi et al. (2006) compared performance of PET and PET/CT. PET/CT resulted in improved diagnostic confidence compared with PET in 60% of patients and in 55% of regions. Another two publications (Radan et al. 2006; Pecking et al. 2001) drew similar results; the use of PET/CT technology indicated only a marginal improvement in diagnostic accuracy, reporting SE, SP and accuracy rates of 90, 71, 83%, and 94, 84, 99%, respectively. Most importantly, several studies demonstrated that FDG-PET/CT had an impact on the management of 51–69% of patients (Radan et al. 2006; Eubank et al. 2004).
To our knowledge, this meta-analysis was the first report that assessed and compared summary estimates of overall diagnostic ability for those non-invasive methods that were currently used for detecting recurrent and/or metastatic breast cancer. In this clinical context, if those methods were compared with each other, the results of our meta-analysis demonstrated that US had the highest SP and PET had the highest SE. The AUC of MRI and PET, whether interpreted with or without the use of CT, was higher than that of US or CT, but there was no statistically significant difference when PET or MRI was compared with SMM. Because of the highest SE, an abnormal US image was always a strong indication of recurrent tumor; however, US had disadvantages in cases of fat necrosis and structural distortion after surgery and furthermore its results do not usually alter the management plan in terms of biopsy or follow-up determined on the basis of physical and/or mammographic findings (Bruneton et al. 1986). Therefore, additional imaging information of the recurrent and/or metastatic foci was necessary to a highly suspected patient with an indeterminate US. In our meta-analysis, both MRI and PET had highest SE, which resulted in higher cancer detection rate. Regarding that PETs’ high expense and modest whole-body radiation exposure, PET was not suited for screening purposes in breast cancer. Therefore, MRI should be the next diagnostic step in patients with an indeterminate or low probability of malignancy. Since that whole-body mets with MRI is impractical in most circumstances, PET had its own advantages in whole-body surveillance for mets. When MRI shows an indeterminate or benign lesion or MRI was not applicable (e.g., pacemaker), FDG-PET could be performed in addition. Furthermore, a lesion that was indeterminate or benign on MRI and negative on PET indicated a very low probability of malignancy. In conclusion, MRI seemed to be a more useful supplement to current surveillance techniques to assess patients with suspected recurrent and/or metastatic breast cancer.
To be sure, our study had some drawbacks. Firstly, the effect of characteristics of the patients could not be examined due to lack of data. Secondly, the reference standard used in this systematic review ranged from histopathologic analysis to follow-up. Thirdly, most results showed heterogeneity, suggesting the needs for high-quality prospective studies and multi-center trials. Fourthly, the possibility of publications bias occurred in our meta-analysis. It was possible that our pooled estimates were too optimistic, as studies with favorable results were more likely to be submitted and published. Finally, further cost-effectiveness analysis should be conducted regards to the surveillance techniques in the breast cancer.
Conclusion
In conclusion, MRI seemed to be a more useful supplement to current surveillance techniques to assess patients with suspected recurrent and/or metastatic breast cancer. If MRI shows an indeterminate or benign lesion or MRI was not applicable (e.g., pacemaker), FDG-PET could be performed in addition.
References
Aide N, Huchet V, Switsers O, Heutte N (2007) Influence of CA 15-3 blood level and doubling time on diagnostic performances of 18F-FDG PET in breast cancer patients with occult recurrence. Nucl Med Commun 28(4):267–272
American Cancer Society (2002) Breast cancer facts and figures. American Cancer Society, Atlanta, GA, pp 9–10
Armington WG, Harnsberger HR, Osborn AG, Seay AR (1987) Radiographic evaluation of brachial plexopathy. Am J Neuroradiol 8(2):361–367
Bäz E, Madjar H, Reuss C, Vetter M (2000) The role of enhanced Doppler ultrasound in differentiation of benign vs. malignant scar lesion after breast surgery for malignancy. Ultrasound Obstet Gynecol 15(5):377–382
Belli P, Pastore G, Romani M, Terribile D, Canadè A (2002) Role of magnetic resonance imaging in the diagnosis of recurrence after breast conserving therapy. Rays 27(4):241–257
Berlin JA (1997) Does blinding of readers affect the results of meta-analyses? University of Pennsylvania Meta-analysis Blinding Study Group. Lancet 350(9072):185–186
Bilbey JH, Lamond RG, Mattrey RF (1994) MR imaging of disorders of the brachial plexus. J Magn Reson Imag 4(1):13–18
Bongers V, Perre C, de Hooge P (2004) The use of scintimammography for detecting the recurrence of loco-regional breast cancer: histopathologically proven results. Nucl Med Commun 25(2):145–149
Bruneton JN, Caramella E, Héry M, Aubanel D (1986) Axillary lymph node metastases in breast cancer: preoperative detection with US. Radiology 158(2):325–326
Cancer Research Campaign (1996) Breast cancer. Cancer Research Campaign, UK, fact sheet
Cwikla JB, Buscombe JR, Parbhoo SP, Kelleher SM (1998) Use of 99Tcm-MIBI in the assessment of patients with suspected recurrent breast cancer. Nucl Med Commun 19(7):649–655
De Cicco C, Trifirò G, Baio S, Sierra ML, Pizzamiglio M (2004) Clinical utility of 99mTc-Sestamibi scintimammography in the management of equivocal breast lesions. Cancer Biother Radiopharm 19(5):621–626
de Verdier HJ, Colletti PM, Terk MR (1993) MRI of the brachial plexus: a review of 51 cases. Comput Med Imaging Graph 17(1):45–50
Deeks JJ (2001) Systematic reviews in health care: systematic reviews of evaluations of diagnostic and screening tests. BMJ 323(7305):157–162
Dehdashti F, Mortimer JE, Siegel BA, Griffeth LK (1995) Positron tomographic assessment of estrogen receptors in breast cancer: comparison with FDG-PET and in vitro receptor assays. J Nucl Med 36(10):1766–1774
Dershaw DD, McCormick B, Osborne MP (1992) Detection of local recurrence after conservative therapy for breast carcinoma. Cancer 70(2):493–496
Devillé WL, Bezemer PD, Bouter LM (2000) Publications on diagnostic test evaluation in family medicine journals: an optimal search strategy. J Clin Epidemiol 53(1):65–69
Devillé WL, Buntinx F, Bouter LM, Montori VM (2002) Conducting systematic reviews of diagnostic studies: didactic guidelines. BMC Med Res Methodol 2:9
Drew PJ, Kerin MJ, Turnbull LW, Imrie M (1998) Routine screening for local recurrence following breast-conserving therapy for cancer with dynamic contrast-enhanced magnetic resonance imaging of the breast. Ann Surg Oncol 5(3):265–270
Eubank WB, Mankoff DA, Takasugi J, Vesselle H (2001) 18Fluorodeoxyglucose positron emission tomography to detect mediastinal or internal mammary metastases in breast cancer. J Clin Oncol 19(15):3516–3523
Eubank WB, Mankoff DA, Vesselle HJ, Eary JF (2002) Detection of locoregional and distant recurrences in breast cancer patients by using FDG PET. Radiographics 22(1):5–17
Eubank WB, Mankoff D, Bhattacharya M, Gralow J (2004) Impact of FDG PET on defining the extent of disease and on the treatment of patients with recurrent or metastatic breast cancer. Am J Roentgenol 183(2):479–486
Fisher ER, Anderson S, Tan-Chiu E, Fisher B (2001) Fifteen-year prognostic discriminants for invasive breast carcinoma: National Surgical Adjuvant Breast and Bowel Project Protocol-06. Cancer 91(8 Suppl):1679–1687
Fleiss JL, Levin B, Paik MC (2003) The comparison of proportions from several independent samples: estimation of the marginal mean proportion. In: Fleiss JL, Levin B, Paik MC (eds) Statistical methods for rates and proportions, 3rd edn. Wiley, New Jersey, pp 212–217
Fueger BJ, Weber WA, Quon A, Crawford TL (2005) Performance of 2-deoxy-2-[F-18]fluoro-d-glucose positron emission tomography and integrated PET/CT in restaged breast cancer patients. Mol Imag Biol 7(5):369–376
Gallowitsch HJ, Kresnik E, Gasser J, Kumnig G, Igerc I (2003) F-18 fluorodeoxyglucose positron-emission tomography in the diagnosis of tumor recurrence and metastases in the follow-up of patients with breast carcinoma: a comparison to conventional imaging. Invest Radiol 38(5):250–256
Gilles R, Guinebretière JM, Shapeero LG, Lesnik A (1993) Assessment of breast cancer recurrence with contrast-enhanced subtraction MR imaging: preliminary results in 26 patients. Radiology 188(2):473–478
Goerres GW, Michel SC, Fehr MK, Kaim AH (2003) Follow-up of women with breast cancer: comparison between MRI and FDG PET. Eur Radiol 13(7):1635–1644
Hagay C, Cherel PJ, de Maulmont CE, Plantet MM (1996) Contrast-enhanced CT: value for diagnosing local breast cancer recurrence after conservative treatment. Radiology 200(3):631–638
Hathaway PB, Mankoff DA, Maravilla KR, Austin-Seymour MM (1999) Value of combined FDG PET and MR imaging in the evaluation of suspected recurrent local-regional breast cancer: preliminary experience. Radiology 210(3):807–814
Hatteville L, Mahe C, Hill C (2002) Prediction of the long-term survival in breast cancer patients according to the present oncological status. Stat Med 21(16):2345–2354
Haug AR, Schmidt GP, Klingenstein A, Heinemann V (2007) F-18-fluoro-2-deoxyglucose positron emission tomography/computed tomography in the follow-up of breast cancer with elevated levels of tumor markers. J Comput Assist Tomogr 31(4):629–634
Heywang-Köbrunner SH, Schlegel A, Beck R, Wendt T (1993) Contrast-enhanced MRI of the breast after limited surgery and radiation therapy. J Comput Assist Tomogr 17(6):891–900
Huedo-Medina TB, Sánchez-Meca J, Marín-Martínez F, Botella J (2006) Assessing heterogeneity in meta-analysis: Q statistic or I 2 index? Psychol Methods 11(2):193–206
Isasi CR, Moadel RM, Blaufox MD (2005) A meta-analysis of FDG-PET for the evaluation of breast cancer recurrence and metastases. Breast Cancer Res Treat 90:105–112
Kamby C, Vejborg I, Kristensen B, Olsen LO (1988) Metastatic pattern in recurrent breast cancer. Special reference to intrathoracic recurrences. Cancer 62(10):2226–2233
Kamel EM, Wyss MT, Fehr MK, von Schulthess GK (2003) [18F]-Fluorodeoxyglucose positron emission tomography in patients with suspected recurrence of breast cancer. J Cancer Res Clin Oncol 129(3):147–153
Kao CH, Wang SJ, Liu TJ (1994) The use of technetium-99m methoxyisobutylisonitrile breast scintigraphy to evaluate palpable breast masses. Eur J Nucl Med 21(5):432–436
Kao CH, Hsieh JF, Tsai SC, Ho YJ (2000) Comparison and discrepancy of 18F-2-deoxyglucose positron emission tomography and Tc-99m MDP bone scan to detect bone metastases. Anticancer Res 20(3B):2189–2192
Khalkhali I, Cutrone J, Mena I, Diggles L (1995) Technetium-99m-sestamibi scintimammography of breast lesions: clinical and pathological follow-up. J Nucl Med 36(10):1784–1789
Khatcheressian JL, Wolff AC, Smith TJ, Grunfeld E (2006) American Society of Clinical Oncology 2006 update of the breast cancer follow-up and management guidelines in the adjuvant setting. J Clin Oncol 24(31):5091–5097
Kim TS, Moon WK, Lee DS, Chung JK (2001) Fluorodeoxyglucose positron emission tomography for detection of recurrent or metastatic breast cancer. World J Surg 25(7):829–834
Kneeland JB, Kellman GM, Middleton WD, Cates JD (1987) Diagnosis of diseases of the supraclavicular region by use of MR imaging. Am J Roentgenol 148(6):1149–1151
Lamuraglia M, Lassau N, Garbay JR, Mathieu MC (2005) Doppler US with perfusion software and contrast medium injection in the early evaluation of radiofrequency in breast cancer recurrences: a prospective phase II study. Eur J Radiol 56(3):376–381 [Epub 2005 Jul 7]
Landheer ML, Steffens MG, Klinkenbijl JH, Westenberg AH (2005) Value of fluorodeoxyglucose positron emission tomography in women with breast cancer. Br J Surg 92(11):1363–1367
Lee VW, Sax EJ, McAneny DB, Pollack S (1993) A complementary role for thallium-201 scintigraphy with mammography in the diagnosis of breast cancer. J Nucl Med 34(12):2095–2100
Liu CS, Shen YY, Lin CC, Yen RF, Kao CH (2002) Clinical impact of [(18)F]FDG-PET in patients with suspected recurrent breast cancer based on asymptomatically elevated tumor marker serum levels: a preliminary report. Jpn J Clin Oncol 32(7):244–247
McLoud TC, Bourgouin PM, Greenberg RW, Kosiuk JP (1992) Bronchogenic carcinoma: analysis of staging in the mediastinum with CT by correlative lymph node mapping and sampling. Radiology 182(2):319–323
Melani E, Sardanelli F, Ottonello C, Parodi RC (1995) Magnetic resonance mammography in suspected tumor recurrences. Radiol Med (Torino) 89(3):219–224 (article in Italian)
Moon DH, Maddahi J, Silverman DH, Glaspy JA (1998) Accuracy of whole-body fluorine-18-FDG PET for the detection of recurrent or metastatic breast carcinoma. J Nucl Med 39(3):431–435
Moses LE, Shapiro D, Littenberg B (1993) Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med 12(14):1293–1316
Moskovic E, Curtis S, A’Hern RP, Harmer CL (1992) The role of diagnostic CT scanning of the brachial plexus and axilla in the follow-up of patients with breast cancer. Clin Oncol (R Coll Radiol) 4(2):74–77
Muüller RD, Barkhausen J, Sauerwein W, Langer R (1998) Assessment of local recurrence after breast-conserving therapy with MRI. J Comput Assist Tomogr 22(3):408–412
Nomura Y, Tsutsui S, Murakami S, Takenaka Y (1999) Prognostic impact of second cancer on the survival of early breast cancer patients. Int J Oncol 14(6):1103–1109
Orel SG, Troupin RH, Patterson EA, Fowble BL (1992) Breast cancer recurrence after lumpectomy and irradiation: role of mammography in detection. Radiology 183(1):201–206
Parker S, Tong T, Bolden S, Wingo PA (1997) Cancer statistics, 1997. CA Cancer J Clin 47:5–27
Pecking AP, Mechelany-Corone C, Bertrand-Kermorgant F, Alberini JL (2001) Detection of occult disease in breast cancer using fluorodeoxyglucose camera-based positron emission tomography. Clin Breast Cancer 2(3):229–234
Piperkova E, Raphael B, Altinyay ME, Castellon I (2007) Impact of PET/CT in comparison with same day contrast enhanced CT in breast cancer management. Clin Nucl Med 32(6):429–434
Preda L, Villa G, Rizzo S, Bazzi L (2006) Magnetic resonance mammography in the evaluation of recurrence at the prior lumpectomy site after conservative surgery and radiotherapy. Breast Cancer Res 8(5):R53
Qayyum A, MacVicar AD, Padhani AR, Revell P (2000) Symptomatic brachial plexopathy following treatment for breast cancer: utility of MR imaging with surface-coil techniques. Radiology 214(3):837–842
Radan L, Ben-Haim S, Bar-Shalom R, Guralnik L (2006) The role of FDG-PET/CT in suspected recurrence of breast cancer. Cancer 107(11):2545–2551
Rajkovaca Z, Vuleta G, Matavulj A, Kovacević P (2007) 99m Tc-sestamibi scintimammography in detection of recurrent breast cancer. Bosn J Basic Med Sci 7(3):256–260
Riebe E, Günther K, Schulz K, Köhler G (2007) Recurrent disease after breast preserving therapy (BPT) and radiation therapy for breast cancer—diagnostic yield of palpation, mammography and ultrasonography. Ultraschall Med 28(4):394–400
Rieber A, Merkle E, Zeitler H, Görich J, Kreienberg R (1997) Value of MR mammography in the detection and exclusion of recurrent breast carcinoma. J Comput Assist Tomogr 21(5):780–784
Rissanen TJ, Mäkäräinen HP, Mattila SI, Lindholm EL (1993) Breast cancer recurrence after mastectomy: diagnosis with mammography and US. Radiology 188(2):463–467
Sackett DL, Haynes RB (2002) The architecture of diagnostic research. BMJ 324(7336):539–541
Schmidt GP, Baur-Melnyk A, Haug A, Heinemann V (2008) Comprehensive imaging of tumor recurrence in breast cancer patients using whole-body MRI at 1.5 and 3 T compared to FDG-PET–CT. Eur J Radiol 65(1):47–58
Shin JH, Han BK, Choe YH, Nam SJ, Park W (2005) Ultrasonographic detection of occult cancer in patients after surgical therapy for breast cancer. J Ultrasound Med 24(5):643–649
Siggelkow W, Zimny M, Faridi A, Petzold K (2003) The value of positron emission tomography in the follow-up for breast cancer. Anticancer Res 23(2C):1859–1867
Siggelkow W, Rath W, Buell U, Zimny M (2004) FDG PET and tumour markers in the diagnosis of recurrent and metastatic breast cancer. Eur J Nucl Med Mol Imag 31(Suppl 1):S118–S124
Soerjomataram I, Louwman MW, Ribot JG, Roukema JA (2008) An overview of prognostic factors for long-term survivors of breast cancer. Breast Cancer Res Treat 107(3):309–330
Stomper PC, Recht A, Berenberg AL, Jochelson MS (1987) Mammographic detection of recurrent cancer in the irradiated breast. Am J Roentgenol 148(1):39–43
Stuhrmann M, Aronius R, Schietzel M (2000) Tumor vascularity of breast lesions: potentials and limits of contrast-enhanced Doppler sonography. Am J Roentgenol 175(6):1585–1589
Suárez M, Pérez-Castejón MJ, Jiménez A, Domper M (2002) Early diagnosis of recurrent breast cancer with FDG-PET in patients with progressive elevation of serum tumor markers. Q J Nucl Med 46(2):113–121
Tatsumi M, Cohade C, Mourtzikos KA, Fishman EK, Wahl RL (2006) Initial experience with FDG-PET/CT in the evaluation of breast cancer. Eur J Nucl Med Mol Imag 33(3):254–262 [Epub 2005 Oct 29]
Ternier F, Houvenaeghel G, Lecrivain F, Brigand BL (2006) Computed tomography in suspected local breast cancer recurrence. Breast Cancer Res Treat 100(3):247–254
The GIVIO Investigators (1994) Impact of follow-up testing on survival and health-related quality of life in breast cancer patients. A multicenter randomized controlled trial. The GIVIO Investigators. JAMA 271(20):1587–1592
Tiling R, Khalkhali I, Sommer H, Linke R (1998) Limited value of scintimammography and contrast-enhanced MRI in the evaluation of microcalcification detected by mammography. Nucl Med Commun 19(1):55–62
Tolmos J, Cutrone JA, Wang B, Vargas HI (1998) Scintimammographic analysis of nonpalpable breast lesions previously identified by conventional mammography. J Natl Cancer Inst 90(11):846–849
Usmani S, Niaz K, Maseeh-Uz-Zaman, Niyaz K (2007) Chest wall recurrence of breast cancer demonstrated on 99mTc-MIBI scintimammography. Nucl Med Commun 28(11):842–846
von Fournier D, Anton H, Junkermann H, Bastert G, van Kaick G (1993) Breast cancer screening. State of the art and introduction to preventive measures. Radiologe 33:227
Wapnir IL, Anderson SJ, Mamounas EP, Geyer CE Jr (2006) Prognosis after ipsilateral breast tumor recurrence and locoregional recurrences in five National Surgical Adjuvant Breast and Bowel Project node-positive adjuvant breast cancer trials. J Clin Oncol 24(13):2028–2037
Webb WR, Gatsonis C, Zerhouni EA, Heelan RT (1991) CT and MR imaging in staging non-small cell bronchogenic carcinoma: report of the Radiologic Diagnostic Oncology Group. Radiology 178(3):705–713
Weir L, Worsley D, Bernstein V (2005) The value of FDG positron emission tomography in the management of patients with breast cancer. Breast J 11(3):204–209
Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25
Winehouse J, Douek M, Holz K, Madjar H (1999) Contrast-enhanced colour Doppler ultrasonography in suspected breast cancer recurrence. Br J Surg 86(9):1198–1201
Wolfort RM, Li BD, Johnson LW, Turnage RH (2006) The role of whole-body fluorine-18-FDG positron emission tomography in the detection of recurrence in symptomatic patients with stages II and III breast cancer. World J Surg 30(8):1422–1427
Yang SK, Cho N, Moon WK (2007) The role of PET/CT for evaluating breast cancer. Korean J Radiol 8(5):429–437
Yilmaz MH, Esen G, Ayarcan Y (2007) The role of US and MR imaging in detecting local chest wall tumor recurrence after mastectomy. Diagn Interv Radiol 13:13–18
Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A (2006) Meta-DiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol 6:31
Open Access
This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://creativecommons.org/licenses/by-nc/2.0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
About this article
Cite this article
Pan, L., Han, Y., Sun, X. et al. FDG-PET and other imaging modalities for the evaluation of breast cancer recurrence and metastases: a meta-analysis. J Cancer Res Clin Oncol 136, 1007–1022 (2010). https://doi.org/10.1007/s00432-009-0746-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00432-009-0746-6