Summary
Mass concentrations of particulate matter (PM10, PM2.5, PM1), lung deposited surface area and particle number concentrations were measured for the first time in all Viennese subway lines inside cabins and in two subway stations, one aboveground and the other underground. The observed data were examined for significant differences between the exposure to fine particulate matter and ultrafine particles. Analysis of the trip averages in the five lines U1, U2, U3, U4 and U6 showed significant differences for PM10, PM2.5 and PM1 (all three mass concentrations: p < 0.001). Medians for PM10, PM2.5 and PM1 were highest in the U1 (73.6, 38.9, 27.1 µg/m3, respectively) and U3 (113.3, 47.1, 26.7 µg/m3, respectively) and significantly higher in the underground subway station than in the subway station on ground level. Regarding ultrafine particles no significant differences were found between the subway lines and no significant differences between the underground subway station and the subway station on ground level; however, new air-conditioned cabins had lower particle number concentrations and both particle number concentrations and lung deposited surface area were higher in cabins with open windows.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Air pollution is one of the main etiological factors in today’s worldwide mortality [1]. Long-term exposure [2, 3] and short-term exposure [4,5,6,7] to fine particulate matter (FPM) are associated with an increase in mortality. The FPM is usually measured as a mass concentration (MC) of all particles smaller than 10 µm (PM10) or 2.5 µm (PM2.5). In addition, the MC of all particles smaller than 1 µm (PM1) were also determined.
Although there is some evidence on negative health effects of ultrafine particles (UFP) [8], evidence for an increase in mortality from UFP is weaker than from FPM and to define the impact of UFP on health further studies are needed [6, 9]. There are also only few studies available on lung deposited surface area (LDSA), a newer unit to define the outer surface of particles influencing cells in the respiratory tract [10, 11]. In urban atmospheres and indoors the high variability of particle number and LDSA in space and time makes it difficult to quantify their impact on health. Not only the size of particles seems to play a role in the toxicity but also the sources, since FPM from mobile sources or coal combustion have a greater impact on mortality than FPM from crustal material [12].
In Vienna, exposure to FPM was found to be associated with an increase in acute and subacute mortality [13] and hospital admissions [14]. Strasser et al. already tested four different types of commuting in Vienna for FPM and UFP pollution. The results showed higher PM2.5 and PM1 in the subway when compared to buses. The PM10, PM2.5 and PM1 concentrations were higher in the subway when compared to cars. Also, particle number concentration (PNC) was higher in trams than in the subway and LDSA was higher on bicycles than when commuting by subway but this exploratory study covered only a small part of the Vienna subway system [15].
In Milan, a study found higher FPM concentrations in the subway in comparison to cars and open-air active modes whereas open-air active modes had the highest UFP levels compared to subway and car, indicating motor traffic influence on open-air active modes [16]. A study in Athens found 3–10 times significantly higher PM concentrations on the underground platforms of the subway system compared to outdoor measurements [17]. In Barcelona, similar results were detected [18], with PM2.5 samples collected in the subway system showing high Fe, Cu, Ba, Mn, Zn and Cr concentrations, possibly released by rail, wheels or brake pads, and the oxidative potential of the particles has been evaluated [19]. A study in Helsinki showed similar PNCs and size distributions at the underground subway station compared to the urban background monitoring site. The PM2.5 was higher at the underground stations compared to the ground level station and to subway wagons and the most enriched element in the samples was iron [20].
This was the first field study in the total Viennese subway system to examine for differences in personal exposure to PM10, PM2.5, PM1, PNC and LDSA.
Material and methods
To evaluate potential risks to health, the 24-hour mean guidelines for PM10 (50 µg/m3) and PM2.5 (25 µg/m3) provided by the World Health Organization (WHO) were used [21] but it has to be considered that commuting time is shorter than 24 h. Since the effect of exposure can vary between individuals and since no indications for thresholds have been found for health effects of PM and UFP, the WHO declares that it is unlikely that any guidelines will lead to complete protection for every individual [21].
Subway line U5 is still under construction, unfinished and could not be included. Also excluded was the U6 concerning LDSA and PNC for comparing air-conditioned with not air-conditioned trains because the U6 uses a different type of train than the other subway lines. Regarding LDSA and PNC for comparing cabins with open windows with cabins with windows closed, only data from not air-conditioned trains were used.
Collection of data
Data were obtained on consecutive workdays in August 2016 for PM10, PM2.5, PM1, PNC and LDSA in all subways and two stations. Measurements were carried out from start to end of the line at three trips per subway line and in two subway stations, one underground (Taborstraße, three stores below street level) and one on street level (Michelbeuern-AKH, open air rail with roofed platforms). Of the three measurements in the subways one took place in an opposing direction to the two other measurements. While measurements in the subway started at approximately 09:00, 12:00 and 15:00 and lasted until the end of the train ride (mean duration of subway rides = 30.6 min; details in Table 1), measurements in the subway stations lasted exactly 30 min starting at 11:00, 12:00 and 13:00 on 26 and 29 August 2016. In the stations 300 PMx measurements and 1800 PNC and LDSA measurements were therefore performed per run. Measuring devices were placed in the most central subway cabin and near the middle of the stations on seating accommodation.
While the U1 and U3 are mainly underground lines, the tracks of the U4 and U6 consist of more aboveground track sections. The U2 consists of almost equivalent underground and aboveground sections and is the newest line. Due to construction works it was not possible to perform measurements in both directions in the track sections (including stations) Oberlaa to Troststraße and Hütteldorf to Hietzing and two stations were passed through without a stop in one driving direction.
Measuring devices
The PM10, PM2.5 and PM1 were measured using an optical particle counter, the GRIMM Aerosol Portable Laser Aerosolspectrometer and Dust Monitor®, Model 1.108 (GRIMM Aerosol Technik Ainring GmbH & Co. KG, Ainring, Germany). It detects particles with aerodynamic diameters over 300 nm. The performance had already been evaluated and compared to another model [22]. The mass concentrations were determined using 6 s intervals. The PNC and LDSA were determined using the miniDiSC® (Dr. Martin Fierz, Fachhochschule Nordwestschweiz, Windisch, Switzerland), measuring in 1 s intervals. The miniDiSC is a diffusion size classifier able to measure number concentrations of UFP between 10 nm and 300 nm as well as LDSA.
Statistics
Data were checked and one extremely high PM10 value was defined as an outlier and removed. For PM10, PM2.5 and PM1, medians for each subway line and station were determined. The data were tested for Gaussian distribution with Kolmogorow-Smirnow tests and tested for significant differences using Mood’s median test. Afterwards, post-hoc analyses were performed on the subway data using the Bonferroni correction to determine pairwise significant differences between the lines. For PNC and LDSA, Gaussian distribution was also tested using Kolmogorow-Smirnow tests and the one-way analysis of variance was used to test for significant differences between the lines and performed Scheffé post hoc analyses afterwards. For comparing the stations, closed with opened windows and for comparing not air-conditioned with air-conditioned trains t‑tests were used.
Results
Except for PM data on 6 subway rides, which were 3–48 s too short due to technical problems, data collection was complete. The comparison of FPM in the subways showed significant differences between all subways (for all three MC: p < 0.001). Post hoc analysis of subways in pairs showed significant differences between the medians of all subways for PM10 except the lines U6 and U4. Also, for PM2.5 significant differences were found for all pairs except U2 and U6. For PM1, more inhomogeneous results were obtained where the pairs U2 and U3, U2 and U1, U4 and U3, U4 and U1, U6 and U3 and U6 and U1 showed significant differences. The PM10 and PM2.5 in the U1 and U3 particularly exceeded the WHO guidelines; however, it must be mentioned that the WHO guidelines apply to a 24-h time period while each subway measurement lasted only half an hour. For PM1, the medians in the U1 and U3 even surpassed the PM2.5 guidelines. The FPM exposure is shown in Figs. 1, 2 and 3.
Furthermore, the analysis of the stations showed significant differences (all three MC: p < 0.001). All three MC medians were approximately three times higher in the underground station than in the ground level subway station (underground subway station vs. ground level subway station: PM10: 61.5 µg/m3 vs. 20.2 µg/m3, PM2.5: 24.6 µg/m3 vs. 7.9 µg/m3, PM1: 14.2 µg/m3 vs. 5.0 µg/m3).
Near the underground subway station considerably lower concentrations were measured simultaneously at ground level by the ambient air monitoring network of the municipality (underground subway station vs. ambient air monitoring network: PM10: 61.5 µg/m3 vs. 17.2 µg/m3, PM2.5: 24.6 µg/m3 vs. 6.5 µg/m3). Near the ground level subway station, the monitoring network of the municipality registered similar PM2.5 (ground level subway station vs. monitoring network: 7.9 µg/m3 vs. 8.7 µg/m3) as were measured inside the station but lower PM10 (ground level subway station vs. monitoring network: 20.2 µg/m3 vs. 11.7 µg/m3).
Regarding UFP, no significant differences were found between the lines in the post hoc tests and no significant differences between the underground and ground level subway station. The PNC and LDSA means and the standard deviations in subway stations are listed in Table 2. A confidence interval of 95% was used. The LDSA and PNC exposures are shown in Figs. 4 and 5.
Significant differences between air-conditioned and not air-conditioned trains (p = 0.023) were found regarding PNC but no significant differences regarding LDSA. Significant differences were also found regarding LDSA (p = 0.02) and PNC (p = 0.005) exposure between cabins with open windows and cabins with closed windows.
Discussion
The highest medians for PM10, PM2.5 and PM1 were found in the U1 and U3 subways. This may be because of the long consecutive tunnel sections on the routes of the U1 and U3. The lack of cleaning or the insufficient air conditioning in the tunnels may lead to a deposition of FPM. The wind of following trains may lead to resuspension of the particles that will then enter the train cabins and therefore the tidal air of passengers. This study found similar results as in Athens [17], Barcelona [18] and Helsinki [20] when comparing the underground station to the ground level station showing higher FPM levels in the underground station. Studies have also shown that air conditioning in trains can reduce FPM levels and could therefore be a potential air cleaning method in subways [17, 18]. This is supported by these results of lower FPM on lines with air-conditioned trains and of lower PNC and LDSA in cabins with closed windows.
The chemical composition of FPM inside the subway system of Vienna still needs to be examined. Some studies showed that the main metal element present in FPM found in subway systems was iron [20, 23, 24]. This could be due to the abrasion of rail tracks, wheels and braking pads inside the subway system [18].
The data collection took place in summer only, so further studies during all seasons should be performed. Equipping stations and trains with measurement devices could be an appropriate way to gather data to more precisely determine air quality in the subway system. Additionally, chemical analysis of the particles found in the subway system should be performed to determine and reduce potential health risks caused by FPM and UFP.
Finally, two benefits of commuting by subway have to be mentioned: Shorter travelling times compared to bus and car reduce the cumulative dose for passengers during commuting and the emission of air pollutants by a subway driven by electricity from water power is much lower than by individual traffic with cars, mainly driven by diesel or gasoline [15, 16]. Since the scientific evidence for UFP’s precise effects on health is incomplete and since there are as yet no ambient air standards for either PNC or LDSA, the data in this study need to be reanalyzed and the potential health effects re-evaluated when more exact scientific evidence is revealed.
References
Landrigan PJ. Air pollution and health. Lancet. 2017;2(1):e4–e5. https://doi.org/10.1016/S2468-2667(16)30023-8.
Pope C III, Burnett RT, Thun MJ, et al. Lung cancer, cardiopulmonary mortality, and long-term exposure to Fine particulate air pollution. JAMA. 2002;1132–41. https://doi.org/10.1001/jama.287.9.1132
Beelen R, Raaschou-Nielsen O, Stafoggia M, Andersen ZJ, Weinmayr G, Hoffmann B, et al. Effects of long-term exposure to air pollution on natural-cause mortality: an analysis of 22 European cohorts within the multicentre ESCAPE project. Lancet. 2014;383(9919):785–95. https://doi.org/10.1016/S0140-6736(13)62158-3.
Anderson H, Atkinson R, Peacock J, Marston L, Konstantinou K. Meta-analysis of time-series studies and panel studies of particulate matter (PM) and ozone (O3). Rep a WHO Task Gr. 2004. pp. 1–68.
Katsouyanni K, Touloumi G, Spix C, Schwartz J, Balducci F, Medina S, et al. Short term effects of ambient sulphur dioxide and particulate matter on mortality in 12 European cities: results from time series data from the APHEA project. BMJ. 1997;314(7095):1658.
Atkinson RW, Mills IC, Walton HA, Anderson HR. Fine particle components and health—a systematic review and meta-analysis of epidemiological time series studies of daily mortality and hospital admissions. J Expo Sci Environ Epidemiol. 2014;25(2):208–14.
Atkinson RW, Kang S, Anderson HR, Mills IC, Walton HA. Epidemiological time series studies of PM2.5 and daily mortality and hospital admissions: a systematic review and meta-analysis. Thorax. 2014;69(7):660–5.
Ostro B, Hu J, Goldberg D, et al. Associations of mortality with long-term exposures to fine and ultrafine particles, species and sources: results from the California Teachers Study Cohort. Environ Health Perspect. 2015;123(6):549–56.
Stafoggia M, Schneider A, Cyrys J, Samoli E, Andersen ZJ, Bedada GB, et al. Association between short-term exposure to Ultrafine particles and mortality in eight European Urban Areas. Epidemiology. 2017;28(2). https://journals.lww.com/epidem/Fulltext/2017/03000/Association_Between_Short_term_Exposure_to.4.aspx. Accessed: 1 June 2019
Kuuluvainen H, Rönkkö T, Järvinen A, Saari S, Karjalainen P, Lähde T, et al. Lung deposited surface area size distributions of particulate matter in different urban areas. Atmos Environ. 2016;136:105–13. http://www.sciencedirect.com/science/article/pii/S1352231016303016.
Moshammer H, Neuberger M. The active surface of suspended particles as a predictor of lung function and pulmonary symptoms in Austrian school children. Atmos Environ. 2003;37:1737–44. http://www.sciencedirect.com/science/article/pii/S1352231003000736.
Laden F, Neas LM, Dockery DW, Schwartz J. Association of fine particulate matter from different sources with daily mortality in six U.S. cities. Environ Health Perspect. 2000;108(10):941–7.
Neuberger M, Rabczenko D, Moshammer H. Extended effects of air pollution on cardiopulmonary mortality in Vienna. Atmos Environ. 2007;41:8549–56. http://www.sciencedirect.com/science/article/pii/S1352231007006279.
Neuberger M, Schimek MG, Horak F, Moshammer H, Kundi M, Frischer T, et al. Acute effects of particulate matter on respiratory diseases, symptoms and functions: Epidemiological results of the Austrian Project on Health Effects of Particulate Matter (AUPHEP). Atmos Environ. 2004;38(24):3971–81. http://www.sciencedirect.com/science/article/pii/S1352231004003036.
Strasser G, Hiebaum S, Neuberger M. Commuter exposure to fine and ultrafine particulate matter in Vienna. Wien Klin Wochenschr. 2018;130(1):62–9. https://doi.org/10.1007/s00508-017-1274-z.
Ozgen S, Ripamonti G, Malandrini A, Ragettli SM, Lonati G. Particle number and mass exposure concentrations by commuter transport modes in Milan, Italy. AIMS Environ Sci. 2016;3(2):168–84. https://doi.org/10.3934/environsci.2016.2.168.
Barmparesos N, Assimakopoulos DV, Assimakopoulos NM, Tsairidi E. Particulate matter levels and comfort conditions in the trains and platforms of the Athens underground metro. AIMS Environ Sci. 2016;3(2):199–219. https://doi.org/10.3934/environsci.2016.2.199.
Martins V, Moreno T, Minguillón MC, Amato F, de Miguel E, Capdevila M, et al. Exposure to airborne particulate matter in the subway system. Sci Total Environ. 2015;511:711–22.
Moreno T, Kelly FJ, Dunster C, Oliete A, Amato F, Capdevila M, et al. Oxidative potential of subway PM2.5. Atmos Environ. 2017;148:230–8.
Aarnio P, Yli-Tuomi T, Kousa A, Mäkelä T, Hirsikko A, Hämeri K, et al. The concentrations and composition of and exposure to fine particles (PM2.5) in the Helsinki subway system. Atmos Environ. 2005;39(28):5059–66. https://www.sciencedirect.com/science/article/pii/S1352231005004486.
World Health Organization. WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide: global update 2005: summary of risk assessment. Geneva: World Heal Organ; 2006. pp. 1–22. http://whqlibdoc.who.int/hq/2006/WHO_SDE_PHE_OEH_06.02_eng.pdf?ua=1.
Burkart J, Steiner G, Reischl G, Moshammer H, Neuberger M, Hitzenberger R. Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditions. J Aerosol Sci. 2010;41(10):953–62.
Qiao T, Xiu G, Zheng Y, Yang J, Wang L, Yang J. Preliminary investigation of PM1 , PM2.5 , PM10 and its metal elemental composition in tunnels at a subway station in Shanghai, China. Transp Res Part D. 2015;41:136–46. https://doi.org/10.1016/j.trd.2015.09.013.
Lee Y, Lee Y, Kim T, Choi JS, Park D. Sources and characteristics of particulate matter in subway tunnels in Seoul, Korea. Int J Environ Res Public Health. 2018;15(11):pii:E2534. https://doi.org/10.3390/ijerph15112534
Acknowledgements
This paper is the result of two diploma theses performed at the Medical University of Vienna. The measurement devices that were used for data collection were provided by the Commission on Climate & Air Quality of the Austrian Academy of Science. Prof. Dr. Moshammer provided help concerning data control and ordered the calibration of the measurement instruments.
Funding
Open access funding provided by Medical University of Vienna.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
K.-P. Posselt, M. Neuberger and D. Köhler declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Posselt, KP., Neuberger, M. & Köhler, D. Fine and ultrafine particle exposure during commuting by subway in Vienna. Wien Klin Wochenschr 131, 374–380 (2019). https://doi.org/10.1007/s00508-019-1516-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00508-019-1516-3