Abstract
Background
Focal pulsed field ablation (FPFA) is a novel and promising method of cardiac ablation. The aim of this study was to report the feasibility, short-term safety, and procedural findings for a broad spectrum of ablated atrial arrhythmias.
Methods
Patients (n = 51) scheduled for ablation of atrial arrhythmias were prospectively included and underwent FPFA using the Galvanize CENTAURI generator with energy delivery through commercially available ablation catheters with ultrahigh-density (UHDx) 3D electroanatomic voltage/local activation time map evaluations. Workflow, procedural data, and peri-procedural technical errors and complications are described.
Results
Planned ablation strategy was achieved with FPFA-only in 48/51 (94%) of the cases. Ablation strategy was first-time pulmonary vein isolation (PVI) in 17/51 (36%), repeat ablation in 18/51 (38%), PVI + in 13/51 (28%), and cavotricuspid isthmus block (CTI)-only in 3/51 (6%). The mean procedure time was 104 ± 31 min (first-time PVI), 114 ± 26 min (repeat procedure), 152 ± 36 min (PVI +), and 62 ± 17 min (CTI). Mean UHDx mapping time to assess lesion formation and block after ablation was 7 ± 4 min with 5485 ± 4809 points. First pass acute (linear) isolation with bidirectional block for anatomical lesion sets was 120/124 (97%) for all PVs, 17/17 (100%) for (any) isthmus, and 14/17 (82%) for left atrium posterior wall (LAPW). We observed several time-consuming integration errors with the used ablation system (mean 3.4 ± 3.7 errors/procedure), one transient inferior ST elevation when ablating CTI resolved by intravenous nitroglycerine and one transient AV block requiring temporary pacing for > 24 h.
Conclusions
FPFA was a highly versatile method to treat atrial arrhythmias with high first-pass efficiency. UHDx revealed acute homogenous low-voltage lesions in ablated areas. More data is needed to establish lesion durability and limitations of FPFA.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
1 Introduction
Recently, pulsed field ablation (PFA) has been introduced as a novel “single-shot” ablation method to achieve isolation of the pulmonary veins [1,2,3,4,5]. Potentially, this new method reduces the risk of collateral organ tissue damage when ablating in the heart, limiting feared complications such as damage to the oesophagus and phrenic nerves and pulmonary vein stenosis [6,7,8,9]. Prospective results and recurrence rates using three different multielectrode PFA catheters designed for “single-shot” pulmonary vein isolation (PVI) have now been reported [1, 4, 5, 10,11,12,13]. Although the 1-year recurrence rates seem comparable to thermal ablation methods, lesion durability, predictability, and safety profile of the systems make PFA very promising. However, so far, the possibility of creating designed ablation lesion sets targeting specific areas of interest, to treat critical isthmuses and have an integration with mapping systems, has been limited in the multielectrode systems. Now the first commercial system for focal PFA (FPFA) has been released consisting of a proprietary generator (CENTAURI, Galvanize EP) which can be coupled to specified ablation catheters and 3D mapping systems. CE-approval followed the data presented from the ECLIPSE AF trial (A. Anic et al. “Pulsed Electric Field Ablation for Pulmonary Vein Isolation (PVI): 90‐Day Remapping Results Using Three Compatible Focal Cardiac Ablation Catheters in the ECLIPSE AF Study”, presented at Heart Rhythm Society, 2022) following initial published pre-clinical data [14]. With this technology becoming readily available for ablation centres worldwide, there is a need to report independent, non-industry sponsored, experience with safety and procedural efficacy with FPFA. Furthermore, assessment of FPFA using detailed mapping systems is needed for optimal individually tailored treatment of all atrial arrhythmias and evaluation of lesion formation.
2 Methods
2.1 Patient selection for FPFA
The study was a prospective inclusion of an all-comer patient cohort for either first-time PVI, repeat procedure or treatment of other atrial arrhythmias. Inclusion was based in a single high-volume referral centre from October 27th, 2022, to March 22nd, 2023. Choice of FPFA PVI was based on the availability of general anaesthesia at our institution. Analysis of procedural and demographic anonymized data was approved by Herlev-Gentofte University Hospital Institutional Review Board (Case Number: 22035743).
2.2 Procedural outline and setup
Standard computed tomography (CT) angiography of the left atrium (LA) and transoesophageal echocardiography with focus on interatrial septum and the LA appendage for thrombus assessment were performed 1 to 3 days in advance to the procedure. On the day of the procedure, all patients were fasting, on uninterrupted direct oral anticoagulant or vitamin K antagonists. Patients were intubated under general anaesthesia without use of paralytics. Five experienced electrophysiologists trained in multielectrode PFA, radiofrequency (RFA), and cryoballoon ablations performed the procedures. Three right femoral vein punctures, with or without ultrasound guidance by discretion of the operator, were obtained and a deflectable decapolar diagnostic catheter was placed in the coronary sinus (CS). For all the left atrial arrhythmias, a transseptal access was achieved by fluoroscopy and pressure-guided transseptal-puncture by use of SL1-sheath and BRK-1 needle as per standard. After access to the LA, systemic heparinization was done with target activated clotting time (ACT) 300–400 s. A NAVISTAR SmartTouch irrigated catheter (Biosense Webster, Irvine, CA, USA) was hereafter introduced to the LA through a steerable sheath. Depending on the planned procedure, a 3D ultrahigh-density (UHDx) bipolar voltage amplitude map and anatomical map were created with penta- or octa-spline multielectrode catheters (Biosense Webster) prior to final decision of an ablation strategy classified for the purpose of this study as either PVI, PVI + (with supplementary lesion sets), repeat procedure, or cavotricuspid-isthmus block (CTI-B)-only. Mapping was done during CS pacing and if patient was in AF from start — a DC conversion was done before mapping initiation. The CENTAURI generator (Galvanize EP) was used and connected as described [14] to the CARTO 3D mapping system (Biosense Webster). Ablation applications were ECG R-synchronized trains of pulsed field with a setting of 25 amperes for anterior wall/roof, CTI, and mitral isthmuses and 22 amperes for posterior wall. For 25 and 22 amperes, 10 and 7 pulse trains were delivered. Irrigation rate was 4 mL/h. In general, applications/tags of 6 mm were placed using the CLOSE protocol [15] but with 20–30% overlap based on the ECLIPSE AF data. For PVI, wide area circumferential ablation (WACA) was targeted. For repeat procedures, a qualitative assessment of the initial UHDx voltage map for determination on isolation, voltage, and scars was made along with formal testing of entry and exit blocks to the veins; thereafter, attempted induction of trigger activity or atrial tachyarrythmias with isoprenaline infusion to a heart rate > 100 bpm and atrial burst pacing was initiated. Hereafter, ad hoc ablation based on the above findings was performed for the repeat procedures. In case of isthmus ablation, an administration of intravenous nitroglycerine 0.2 mg over 1 min was given prior to ablation with an additional dose of 0.2 mg if possible after (any) hypotension had been resolved by concomitant vasopressor and/or saline infusion. Atrial tachycardias were mapped accordingly using local activation time maps and coherence conduction vectors to establish critical isthmuses and circuits with supplementary entrainment mapping if needed as per clinical standard and described [10, 16,17,18]. Following ablations, one or more confirmatory detailed UHDx bipolar voltage amplitude 3D maps of the ablation line(s) in LA or right atrium were performed with the multielectrode catheter using proximal CS pacing. Supplementary paced local activation time evaluation over ablation lines could be applied in cases of isthmus block if deemed of relevance. The colour display range of the bipolar voltage map was set to 0.2 to 0.5 mV to visualize gaps, zones of healthy tissue, and low-voltage areas. After the map, a qualitative evaluation of the performed lesion set/ablations line(s) was done along with adenosine testing for dormant conduction. Follow-up of complications up to 14 days after the procedure was available through chart review.
2.3 Statistical analysis
For continuous variables, the mean ± SD or median ± ÍQR were used as appropriate. For categorical values, the number and percentages were used.
3 Results
A total of 51 patients with atrial fibrillation (AF) or atrial tachycardia (AT) (paroxysmal AF = 29, persistent AF = 19) with overlapping diagnoses of AT, atypical flutter, and typical flutter were included to receive ablation treatment with FPFA. It was first-time ablation procedure for 33/51 (65%) and a repeat procedure for 18/51 (35%). Baseline patient characteristics are presented in Table 1. In summary, patients were 65 ± 12 years old, 67% were male, average BMI was 27.7 ± 4.3 kg/m2, 49% had hypertension, and 16% had heart failure. The mean left ventricular ejection fraction was 55 ± 9% and 57% had moderately or severely dilated LA. Concomitant pharmacotherapy at time of procedure included beta-blockers (82%), flecainide (14%), and amiodarone (25%).
3.1 Procedural results
The 51 procedures were performed by five electrophysiologists experienced with multielectrode PFA, cryoballoon, and RFA, distributed case numbers 13, 12, 11, 10, and 5. All patients were under general anaesthesia. Overall mean procedure time was 118 ± 37 min (median 112 min) and mean fluoroscopy time was 6 ± 3 min (Table 2). The planned ablation strategy was achieved with FPFA-only in 48/51 (94%) of the cases. In two of the three cases where FPFA was supplemented by RFA was because of safety-concerns of potential risk of coronary spasm when ablating a CTI line in a patient with severe coronary artery disease and in one case of an anterior mitral isthmus line. The third use of hybrid FPFA and RFA was because of technical error and shut-down of the FPFA system. Ablation strategy was first-time PVI in 17/51 (36%), repeat ablation in 18/51 (38%), PVI with additional lesion set (PVI +) in 13/51 (28%), and CTI-B only in 3/51 (6%). A total of 100% of the cases were evaluated with UHDx maps. Average post-ablation mapping time was 7 ± 4 min and mean number of mapping points was 5485 ± 4809. The overall mean number of FPFA applications (tags) was 53 ± 27 and mean time from first application to last FPFA application was 47 ± 29 min as a surrogate marker of ablation time.
3.2 Pulmonary vein isolation
A total of 30 first-time PVIs were ablated, of which 17 (57%) were PVI-only and 13 (43%) were PVI with additional lesion set (PVI +). Complete PVI was achieved with FPFA-only in 29/30 (97%) patients for the reasons described above. First-pass isolation was achieved in 58/60 (97%) of the left-sided veins and in 64/64 (100%) of the right-sided veins (total 122 of 124). The mean number of PVI applications/tags was 65 ± 8 WACA lesions with an average “treatment” time of 46 ± 12 min from first application/tag to last application/tag for PVI-only. Mean skin to skin procedure time was 106 ± 31 min for PVI-only. Post-PVI UHDx mapping (mean 7 ± 4 min) showed WACA lines with sharp demarcation of lesion border zones with no apparent areas of complex electrogram-fractionation in most of the cases (26/30) (Fig. 1). We, however, also observed 4/30 (13%) cases with increased areas of low voltage on the left atrial posterior wall (LAPW) of unknown significance in the border zones of the application/tags (Fig. 2). No fractionation was observed in these 4 cases. Acute reconduction was found in 1/124 veins (1%) located anteriorly-superiorly in the right superior PV during post-PVI mapping. Supplementary adenosine testing for dormant conduction after mapping was negative in 64/64 (100%) of the tested veins (Table 3).
3.3 Left atrium posterior wall isolation
A total of 17 left atrium posterior wall isolations (LAPWi) were completed, of which 12/17 (71%) were as repeat procedures and 5/17 (29%) were part of a PVI ( +) strategy. Using roof zenith and inferior nadir linear ablation lines (Figs. 3 and 4) resulted in first-pass linear isolation in 14/17 (82%), while additional ablation of epicardially connected fibres was necessary in the LAPW centre zone in 3/17 (18%). Mean roof-line and inferior line number of applications/tags were 18 ± 11 and 12 ± 1, respectively, while 4, 4, and 8 additional applications were used in the centre zone for isolation in the three cases of no linear first-pass isolation. No acute reconnection or dormant conduction was observed in any of the 17 LAPWi and mapping (mean points 6993 ± 7487) showed sharp demarcation of lesion border zones with no apparent areas of complex electrogram-fractionation.
3.4 Isthmus lines
In context of PVI( +), as part of repeat procedure or as a stand-alone procedure, a total of 17 isthmus lines were created with FPFA due to macro-reentry tachycardias, 12 CTI-B, and four mitral-isthmus blocks (MIB) (three anterior lines and one lateral) (Fig. 5). In all cases of ongoing macro-reentry tachycardias, we experienced acute termination following FPFA of the intended line. The mean number of FPA applications/tags was 9 ± 3 and 13 ± 4 for CTIB and MIB, respectively. After anatomical linear line, a formal block was confirmed by pacing manoeuvers in 17/17 (100%) and CS paced UHDx maps (mean mapping points 6071 ± 4373, mean mapping time 8 ± 3 min) showed sharp demarcation of lesion border zones and propagation block on the line. In one repeat procedure, a focal atrial tachycardia was mapped according to earliest activation to the mid portion of the terminal crest in the right atrium. Ongoing tachycardia was terminated upon first application of FPFA to the area, and was hereafter non-inducible.
3.5 Complications
The acute complications are presented in Table 4. We observed two complications related to the procedures. One case of prolonged complete atrioventricular (AV) block in a patient with first-degree AV block present at the beginning of the procedure, necessitating a temporary pacemaker for 24 h, but hereafter resolution of the block. During the PVI and ablation of the right sided veins — first progression to a left bundle branch block became apparent. Shortly after procedure termination, a further progression of the conduction delay led to second-degree AV block and then complete AV block. One case of ST-elevations in the inferior leads was also observed despite an initial dose of 0.2 mg of nitroglycerine had been given prophylactic before initiation of a CTI-B. ST-elevations occurred approximately 5 min after the administration during FPFA applications. An additional 0.2-mg nitroglycerine administration resolved the ST-elevations and no further problems were seen.
FPFA to the right sided veins resulted in phrenic nerve capture, but no phrenic nerve palsies were observed. In one case of roof-line FPFA applications, singular premature ventricular complexes were seen after every application but resolved hereafter. We observed no ventricular arrhythmias, no strokes, tamponades or evidence of oesophageal injury, and no deaths related to the procedures. There were no vascular complications leading to hospitalization or interventions; however, 1 (2%) vascular hematoma was observed and handled conservatively.
3.6 Integration errors
Over the course of the 51 ablation procedures, several errors and issues were noted mainly due to integration errors with the mapping system (Table 5). Some errors were more prevalent and time-consuming than others. After every FPFA application, the system must restore connection resulting in disappearance of the catheter and catheter parameters in the 3D mapping system and a re-visualization of catheter parameters is initiated (error 2604). In a representative sample of 10 FPFA applications, we estimated the time from last FPFA application to the catheter was visible again with available parameters and ready to move to 14 ± 8 s. With an average number of tags/applications for standard PVI of 65, this is potentially more than 15 min of catheter recovery time — which is in line with our experiences. Another compatibility issue was a patch error unit (error 1003), resolved by physical disconnection and reconnection of the patch unit cable. This error was found to be more prevalent the more applications were applied (R2 = 0.48). The average number of patch unit error per case was 3.4 ± 3.7. In two cases, asynchronous FFPA applications were necessary due to ECG synchronization error. In additional five cases, various heterogeneously distributed errors were observed without any apparent (i.e. errors 1011, 1012) systematic cause resolved typically by shut-down and re-booting of the patient interface unit (PIU). In one case, as previously mentioned, an integration error of undetermined cause resulted in shut-down of the PFA system-mapping system compatibility and a change to RFA-only was necessary.
4 Discussion
This report outlines the initial experiences, feasibility, acute procedural success, safety, and UHDx mapping evaluations of a variety of ablation procedures all treated with FPFA. The main findings were a high rate of acute procedural success with very high first-pass efficiency for PVI, LAPWi, and anatomical lines with a low rate of adverse events. The integration with a mapping system allowed individually tailored FPFA treatment resulting in versatile, flexible, and high acute treatment success of all types of observed atrial arrhythmias. This is the first study of FPFA to evaluate acute procedural results for a broad spectrum of consecutive atrial arrhythmias.
4.1 Pulmonary vein isolation
Using UHDx mapping, we found that tissue voltage was reduced to minimum values in the ablated areas resulting in WACA for PVI and conduction blocks for linear ablation lines. Whether this results in durable lesions or is part of a stunning phenomenon remains to be explored. It is important to keep in mind that acute isolation is not a surrogate for durable isolation or freedom from AF for that matter. The preliminary data from the ECLIPSE-AF trial presented at HRS 2022 was however promising, and suggested a 90-day PVI durability of 92% (n = 63) (Anic A. et al. Pulsed Electric Field Ablation for Pulmonary Vein Isolation (PVI): 90‐Day Remapping Results Using Three Compatible Focal Cardiac Ablation Catheters in the ECLIPSE AF Study; abstract presented at HRS 2022). Importantly, in the present non-industry sponsored all-comer atrial arrhythmia population, we were able to demonstrate similar first-pass acute success and efficiency for PVI as presented in ECLIPSE-AF. In a recent publication from our group, we saw that high-density 3D mapping evaluation after PVI by multielectrode PFA resulted in acute PVI but insufficient WACA lesion sets and particularly right sided gaps resulting in additional applications of PFA in up to 20% [16], which calls for caution on the termed success of acute PFA isolation. Bohnen et al. found insufficient lesion formation after PFA PVI more often located in the anterior antral parts of the left sided veins [19], while Gunawardene et al. found early PV-reconnection in 5/80 (6.3%) all located in the anterior–superior PV ostia on both left and right sides [20]. Thus, so far, there is inconclusive evidence of the acute and chronic lesion formation as well as the antral WACA coverage after multielectrode PFA in all-comer AF populations. Furthermore, in the only published series of recurrent AT in repeat procedures after PVI with multielectrode PFA performed under fluoroscopy, without mapping guidance, there seems to be a predominance of roof-dependent ATs fuelled by narrow isthmus formations of the posterior wall [21]. The PV reconnection rate was 9% in that study (n = 25). In this series of PVI — we only observed acute reconduction in one of 124 PVs despite using both the observation time of additional lesion set ablations (for PVI ( +)), detailed mapping and supplementary adenosine testing for dormant conduction.
4.2 Macro-reentry tachcardias
Integration of FPFA with UHDx mapping systems allows for detailed identification of scar tissue and identification of AT mechanisms and HD mapping has been shown to improve detection of areas critical to maintain AT circuits [22]. We saw acute FPFA termination of focal atrial and macro-reentry tachycardias in all cases and achieved acute formally confirmed block in all isthmus lines. In addition, we saw no reconnections during the mapping time for the treated anatomical isthmuses. Again, whether this is due to a temporary stunning effect or a result of potential durable lines remains to be explored. Previous reports showed only 58% complete block of an anterior mitral-isthmus line when treated with RFA [23], while more recent data from the temperature-controlled lattice-tip focal RFA catheter, however, showed very high mitral-isthmus line durability of 91% (n = 11) and 100% for CTI lines (n = 25). Similarly, present FPFA results are also encouraging of achieving successful anatomical linear blocks. In the PersAFone study [24], acute CTI bidirectional block was achieved in 13 of 13 (100%) patients using the same large focal lattice-type catheter as above but utilizing PFA and was in that study delivered at a median of 6 sites (IQR: 5 to 7 sites) per CTI with an average of 9 min (IQR: 6 to 12 min) between the first and last PFA deliveries. Follow-up durability mapping of CTI from PersAFone at a median of 87 days (IQR: 76 to 90 days) after index procedure showed 25% durability for the first four patients who were exposed to a lower initial PFA dose (called Focal-1 of 1.6 kV) compared to 100% durability in eight out of eight patients with Focal-2 of 1.8 kV of PFA dosing. To our knowledge, there has not been published any repeat mapping procedures after PFA of the mitral isthmus. As mentioned, we also successfully ablated one focal atrial tachycardia from the terminal crest in the right atrium as part of PVI ( +). Recently, a case report highlighted the possibilities of successful FPFA of an AT in close proximity to the phrenic nerve [25].
4.3 Left atrium posterior wall
Although multielectrode PFA has been shown to be useful and feasible for successful ablation of the LAPW with or without supplementary mapping [10, 16, 24], feedback on contact and force values may be important for optimal and durable lesion formation of PFA [26]. These parameters are not yet available in clinical practice. In 21/21 (100%) invasive remapping procedures performed after 82 (IQR 76–90) days, the LAPW was found durably isolated in the PersAFone study [24]. Compared to our recent published experiences with RFA-based LAPWi, where as many as 33% required ablations in the centre PW for isolation and a rather low 46% LAPWi durability rate at 6 months at the cost of asymptomatic, yet worrisome, oesophageal lesions [27, 28], we find LAPWi with FPFA highly effective. Oesophageal safety for FPFA has not been fully established but so far preclinical and clinical data from multielectrode PFA seem convincing and reassuring [3, 7, 24]. Since no trial has yet established LAPWi as a superior ablation strategy on top of standard PVI for persistent AF [29], speculations on causal issues such as the low durability of the LAPWi arise, which may now be potentially partly solved by PFA. This remains to be proven in a randomized trial. Furthermore, the utility of LAPWi as step two for repeat procedures with durable PVI remains to be proven in a randomized trial, most preferably with a method that has a proven durable lesion set. Although we cannot correlate that combination of detailed mapping and FPFA leads to improved outcomes, we found that supplementary LAPWi was feasible with high acute isolation rate for persistent and long-standing persistent AF patients but also as a strategy for supplementary ablation treatment in repeat procedures with LAPW scar fractionation and/or durably isolated veins from initial PVI.
4.4 Feasibility/safety
We found a low rate of acute complications. Being well aware of the issues of reported coronary spasms when performing PFA close to the coronary arteries [11], administration of nitroglycerine was done upfront. In one case, there were still ST-elevations which resolved by further treatment with nitroglycerine and this issue remains to be further evaluated in larger series. The apparent stunning of the conduction system and temporary AV block we experienced when ablating closer to the septum is also of concern and needs further exploration. The observed complication occurred in a patient with 1st-degree AV block present prior to the procedure. Whether there is increased risk of AV block in patients predisposed to intraatrial, septal, and AV node conduction delay remains to be evaluated in larger series. The right atrium was not mapped in the patient but no apparent septal fibrotic tissue was present in the LA map and the WACA spatial line around the right septal veins was “standard”. Mapping and integration errors reflect a 1st-generation system as can be expected. Currently, the procedure time and technical skills required for point-by-point ablation still pose a limitation of FPFA for standard PVI in comparison to single-shot PFA techniques. In contrast, the combination of UHDx and detailed AT circuit mapping with FPFA treatment tailored to area-specific targets with a high first-pass and acute termination effect seems promising for both repeat procedures and for first-time AT ablation. Furthermore, this approach can be performed with low fluoroscopy doses but point-by-point ablations may require a prolonged learning curve and longer procedure times than single-shot. Recently, the SmartfiRE trial was initiated aiming to include 135 participants in a prospective evaluation of another FPFA system (clinicaltrials.gov NCT 05752487) while the publication and recurrence rates of the ECLIPSE-AF trial are eagerly awaited.
5 Limitations
This is a real-life application of a newly introduced and commercially available ablation technique. The small sample size limits the conclusions on safety and it is too early to report credible recurrence rates. Being a single-centre study, this limits the applicability to other centres. However, the present study reports the safety, feasibility, and acute efficacy of the present PFA system and cannot be extrapolated to other PFA systems.
6 Conclusions
FPFA was a highly versatile method to treat all encountered atrial arrhythmias with high first-pass efficiency for PVI as well as successful creation of LAPWi and atrial isthmus blocks and acute termination of ATs. UHDx was used effectively to map ATs and revealed acute homogenous low-voltage lesions in ablated target areas. More data is needed to establish lesion durability and limitations of FPFA.
References
Reddy VY, Dukkipati SR, Neuzil P, Anic A, Petru J, Funasako M, et al. Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II. JACC Clin Electrophysiol. 2021;7(5):614–27.
Reddy VY, Neuzil P, Koruth JS, Petru J, Funosako M, Cochet H, et al. Pulsed field ablation for pulmonary vein isolation in atrial fibrillation. J Am Coll Cardiol. 2019;74(3):315–26.
Ekanem E, Reddy VY, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF). Europace. 2022;24(8):1256–66.
Verma A, Haines DE, Boersma LV, Sood N, Natale A, Marchlinski FE, et al. Pulsed field ablation for the treatment of atrial fibrillation: PULSED AF pivotal trial. Circulation. 2023;147(19):1422–32.
Duytschaever M, De Potter T, Grimaldi M, Anic A, Vijgen J, Neuzil P, et al. Paroxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study. Circ Arrhythm Electrophysiol. 2023;16(3):e011780.
Neven K, Futing A, Byrd I, Heil RW Jr, Fish JM, Feeney DA, et al. Absence of (sub-)acute cerebral events or lesions after electroporation ablation in the left-sided canine heart. Heart Rhythm. 2021;18(6):1004–11.
Neven K, van Es R, van Driel V, van Wessel H, Fidder H, Vink A, et al. Acute and long-term effects of full-power electroporation ablation directly on the porcine esophagus. Circ Arrhythm Electrophysiol. 2017;10(5). https://doi.org/10.1161/CIRCEP.116.004672.
Koruth JS, Kuroki K, Kawamura I, Brose R, Viswanathan R, Buck ED, et al. Pulsed field ablation versus radiofrequency ablation: esophageal injury in a novel porcine model. Circ Arrhythm Electrophysiol. 2020;13(3):e008303.
Koruth JS, Kuroki K, Kawamura I, Stoffregen WC, Dukkipati SR, Neuzil P, et al. Focal pulsed field ablation for pulmonary vein isolation and linear atrial lesions: a preclinical assessment of safety and durability. Circ Arrhythm Electrophysiol. 2020;13(6):e008716.
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Pulsed field ablation in real-world atrial fibrillation patients: clinical recurrence, operator learning curve and re-do procedural findings. J Interv Card Electrophysiol. 2023. https://doi.org/10.1007/s10840-023-01495-y.
Reddy VY, Petru J, Funasako M, Kopriva K, Hala P, Chovanec M, et al. Coronary arterial spasm during pulsed field ablation to treat atrial fibrillation. Circulation. 2022;146(24):1808–19.
Schmidt B, Bordignon S, Tohoku S, Chen S, Bologna F, Urbanek L, et al. 5S study: safe and simple single shot pulmonary vein isolation with pulsed field ablation using sedation. Circ Arrhythm Electrophysiol. 2022;15(6):e010817.
Lemoine MD, Fink T, Mencke C, Schleberger R, My I, Obergassel J, et al. Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario. Clin Res Cardiol. 2022. https://doi.org/10.1007/s00392-022-02091-2.
Verma A, Neal R, Evans J, Castellvi Q, Vachani A, Deneke T, et al. Characteristics of pulsed electric field cardiac ablation porcine treatment zones with a focal catheter. J Cardiovasc Electrophysiol. 2023;34(1):99–107.
Duytschaever M, De Pooter J, Demolder A, El Haddad M, Phlips T, Strisciuglio T, et al. Long-term impact of catheter ablation on arrhythmia burden in low-risk patients with paroxysmal atrial fibrillation: the CLOSE to CURE study. Heart Rhythm. 2020;17(4):535–43.
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Utility of high-density 3D-bipolar voltage map after pulmonary vein isolation by pulsed-field ablation. JACC Clin Electrophysiol. 2023. https://doi.org/10.1016/j.jacep.2022.11.030.
Vicera JJB, Lin YJ, Lee PT, Chang SL, Lo LW, Hu YF, et al. Identification of critical isthmus using coherent mapping in patients with scar-related atrial tachycardia. J Cardiovasc Electrophysiol. 2020;31(6):1436–47.
Ruwald MH, Johannessen A, Hansen ML, Worck R, Hansen J. Pulsed field ablation of the cavotricuspid isthmus using a multispline-electrode pulsed field ablation catheter. HeartRhythm Case Rep. 2022;8(3):147–50.
Bohnen M, Weber R, Minners J, Jadidi A, Eichenlaub M, Neumann FJ, et al. Characterization of circumferential antral pulmonary vein isolation areas resulting from pulsed-field catheter ablation. Europace. 2022;25(1):65–73. https://doi.org/10.1093/europace/euac111.
Gunawardene MA, Schaeffer BN, Jularic M, Eickholt C, Maurer T, Akbulak RO, et al. Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: practical and electrophysiological considerations. J Cardiovasc Electrophysiol. 2022;33(3):345–56.
Tohoku S, Chun KRJ, Bordignon S, Chen S, Schaack D, Urbanek L, et al. Findings from repeat ablation using high-density mapping after pulmonary vein isolation with pulsed field ablation. Europace. 2022;25(2):433–40. https://doi.org/10.1093/europace/euac211.
Vlachos K, Efremidis M, Derval N, Martin CA, Takigawa M, Bazoukis G, et al. Use of high-density activation and voltage mapping in combination with entrainment to delineate gap-related atrial tachycardias post atrial fibrillation ablation. Europace. 2021;23(7):1052–62.
Sanders P, Jais P, Hocini M, Hsu LF, Scavee C, Sacher F, et al. Electrophysiologic and clinical consequences of linear catheter ablation to transect the anterior left atrium in patients with atrial fibrillation. Heart Rhythm. 2004;1(2):176–84.
Reddy VY, Anic A, Koruth J, Petru J, Funasako M, Minami K, et al. Pulsed field ablation in patients with persistent atrial fibrillation. J Am Coll Cardiol. 2020;76(9):1068–80.
Phlips T, Verhaeghe L, Antole N, Koopman P, Vijgen J. Pulsed field ablation using a focal contact force catheter allowed successful ablation of a focal right atrial tachycardia in the proximity of the phrenic nerve. HeartRhythm Case Rep. 2023. https://doi.org/10.1016/j.hrcr.2023.03.016.
Nakagawa H, Castellvi Q, Neal R, Girouard S, Ikeda A, Kuroda S, et al. Effects of contact force on lesion size during pulsed field ablation. Heart Rhythm. 2021;18(PO03-131):S242–3.
Worck R, Sorensen SK, Johannessen A, Ruwald M, Haugdal M, Hansen J. Posterior wall isolation in persistent atrial fibrillation feasibility, safety, durability, and efficacy. J Cardiovasc Electrophysiol. 2022;33(8):1667–74.
Worck R, Sorensen SK, Johannessen A, Ruwald MH, Hansen ML, Haugdal M, et al. Posterior wall isolation in persistent atrial fibrillation. Long-term outcomes of a repeat procedure strategy. J Interv Card Electrophysiol. 2023;66(4):971–9. https://doi.org/10.1007/s10840-022-01402-x.
Kistler PM, Chieng D, Sugumar H, Ling LH, Segan L, Azzopardi S, et al. Effect of catheter ablation using pulmonary vein isolation with vs without posterior left atrial wall isolation on atrial arrhythmia recurrence in patients with persistent atrial fibrillation: the CAPLA randomized clinical trial. JAMA. 2023;329(2):127–35.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethical approval
This research study was conducted retrospectively from data obtained for clinical purposes utilizing anonymized data approved by Herlev-Gentofte University Hospital Institutional Review Board (Case Number: 22035743).
Informed consent
Not applicable.
Conflict of interest
MHR, AJ, MLH, and MH have nothing to disclose. RW has received research grants and speaker honoraria from Biosense Webster not related to the present work and JH has received grants, speaker honoraria, and consultant fees from Biosense Webster and speaker honoraria and consultant fees from Boston Scientific not related to the present work.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Ruwald, M.H., Johannessen, A., Hansen, M.L. et al. Focal pulsed field ablation and ultrahigh-density mapping — versatile tools for all atrial arrhythmias? Initial procedural experiences. J Interv Card Electrophysiol 67, 99–109 (2024). https://doi.org/10.1007/s10840-023-01570-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10840-023-01570-4