Abstract
We conducted this study to evaluate the use of rail fixation system in infected gap non-union of femur and tibia as an alternative to the established Ilizarov circular fixator technique. Prospective study. The study was done in the Department of Orthopaedic surgery in a medical school and level I trauma center to which the authors are/were affiliated. Between June 2010 and June 2015, 40 patients with infected gap non-union of femur and tibia were treated with the rail fixation system. Patients who were willing to undergo surgery and participate in the post-operative rehabilitation were included in the study. After radical debridement, the system was applied and corticotomy done. For closure of bone gap, acute docking and distraction was done in 18 cases and segmental bone transport in 22 cases. Early mobilization of patient was done along with aggressive physiotherapy. Bone and functional results were calculated according to ASAMI scoring system, and complications were classified according to Paley classification. The mean follow-up period was 22.56 months (range 8–44). Bone union with eradication of infection was achieved in all but 1 case (97.5%). Bone results were excellent in 57.5%, good 40%, fair 0% and poor in 2.5% cases, while functional result was excellent in 32.5%, good 65%, fair 0% and poor in 2.5% cases. The rail fixation system is an excellent alternative method to treat infected gap non-union of femur and tibia. It is simple, easy to use and patient-friendly.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Segmental defects created after debridement for infected non-union of long bones can be managed by external fixation and bone grafting, bone transport or microvascular free-tissue transfer [1–4]. The Ilizarov principles are the basis for modern successful treatment [5, 6]. However, when the principles are applied using the conventional Ilizarov fixator with its transosseous tensioned wires, there are disadvantages: local anatomy is distorted; soft tissues are transfixed; there is a risk of neurovascular impingement; and the circumferential fixator is poorly tolerated [7, 12]. The circular fixator is cumbersome and interferes with conduct of personal hygiene, especially when rings are used in upper thigh [8–10]. To overcome these disadvantages, some modifications were introduced, e.g. use of half pins and femoral arches [10, 11]. In contrast, a monolateral external fixator has advantages with being located to one side of the limb, is usually easier to apply and remove and has greater patient acceptance [13, 14]. This study evaluates the use of a monolateral fixator for treating segmental defects after treatment of infected non-unions of the femur and tibia.
Patients and methods
A total of 40 patients with infected non-unions of the femur and tibia were treated with a monolateral fixator between June 2010 and June 2015. A retrospective review was conducted. The inclusion criteria were all cases of infected non-union of femur and tibia that had a segmental defect; limbs had to be normal in the neurological and vascular status and the contralateral limb functionally good enough so as not to influence the rehabilitation process. Patients who were medically unfit for surgery and those unwilling to participate in the prolonged post-operative rehabilitation were excluded.
Of the 40 patients, the femur was involved in 22 and the tibia in 18. There were 35 males with an average age of 29.3 years and 5 females with average age of 38.3 years. The right extremity was involved in 25 cases and the left in 15. Clinical and radiological examination established the diagnosis. The causes of infected non-union were: sequel to open fractures (19 cases—47.5%); closed fracture treated with internal fixation with subsequent infection (10 cases—25%); and chronic osteomyelitis as a sequel to acute osteomyelitis (11 cases—27.5%). The non-union was classified according to the classification by Rosen as active (3 cases), draining (11 cases) and quiescent (26 cases) [15]. The mean number of previous surgeries was 1.44 (range 0–3) including repeated debridement, intramedullary nailing, plating and/or external fixation.
Treatment consisted of removal of existing implants, radical debridement and the application of the monolateral fixator. Bone debridement continued until residual bone showed evidence of punctate cortical bleeding (the paprika sign). The monolateral fixator was placed laterally in the femur and anteromedially in the tibia. In those cases where a segmental defect of less than 5 cm in the femur (11 patients) or 3 cm in the tibia (7 patients) was encountered, acute docking and subsequent lengthening was carried out. In the remaining cases, segmental bone transport was done. Iliac crest bone graft was added to the docking site in 5 cases of acute docking.
Active and passive mobilization of the adjacent joints was started on second post-operative day. Ambulation and partial weight-bearing was started on the 2nd or 3rd post-operative day depending on pain, bone quality and patient compliance. Distraction at the corticotomy site was started between the 7th and 14th day at rate of 1 mm/day (0.25 mm every 6 h). Pin track dressings were of sterile gauze and normal saline. At the time of discharge, patients were educated to deliver pin track care, perform distraction and physiotherapy for joint mobilization and muscle strengthening. Regular follow-up every 4 weeks was done. Checks on pin loosening, pin track infections were carried out and radiographs obtained. The fixator was dynamised once clinical (the absence of deformity or abnormal mobility, the ability to walk and stand on the operated leg without pain) and radiological (3 or more cortices on two orthogonal views) union was declared [16]. After dynamisation, if the patient could weight bear without pain, the fixator was removed as an outpatient procedure under sedation. The operated extremity was protected with functional cast brace for 4 weeks after removal of the fixator.
Institutional ethics committee approval was obtained for the study. All the patients or their guardians provided informed written consent.
Results
All 40 patients were available for follow-up. The bone and functional results were graded as excellent, good, fair and poor [17]. (Table 1) The external fixation index (EFI) was calculated as a ratio of the number of days the frame was used to the length of regenerated bone (cm). The mean follow-up period was 22.92 months (range 12–44). The fixator was used for an average of 13.6 months (range 6–30). The mean length of regenerated bone was 7.17 cm (range 1–15). The mean EFI was 56.9 days/cm. The mean residual limb length discrepancy was 1.04 cm (range 0–4).
Of the 40 cases included in the study, 23 had excellent, 16 good, none had fair and 1 case had a poor bone result. Functional results were found excellent in 13 cases, good in 26, fair in none and poor in one. The patient with a poor result was a 65-year-old diabetic who had an infected non-union of the mid-shaft of the tibia after an open fracture 13 years previously. This was treated with monolateral frame and bone transport. This resulted in a docking site non-union; he refused secondary bone grafting. The frame was removed and patient opted to walk with crutches indefinitely (Fig. 1).
In our study, 22 cases underwent segmental transport (14 femur and 8 tibia) and 18 cases were treated with acute docking and bone transport (11 femur and 7 tibia; Fig. 2). Primary bone grafting at docking site was done in 5 cases. Except for the case with the poor result (see above) who refused a secondary grafting procedure to the docking site, none of the other cases required secondary procedures to achieve bony union. Docking site union was noted to be faster when primary bone grafting was done (Figs. 2, 3, 4, 5, 6).
Complications that occurred during the treatment period were graded according to Paley’s working classification as problem, obstacle or true complication [18]. True complications were divided as minor or major. In this study, all patients had one or more pin track infections which resolved with regular pin track dressing and antibiotics (problem). Post-operative joint stiffness resolved completely in 10 patients with physiotherapy. Fifteen patients had pin track infections which required the removal of the pin and or insertion of a new pin (obstacle). True complications presented in the form of joint stiffness. Twenty-two patients had joint stiffness prior to commencement of treatment and showed no improved in range of movement at the end of treatment despite intensive physiotherapy. Two patients who were non-compliant with the post-operative physiotherapy programme developed joint stiffness at the end of treatment period. Eight patients had an axial deformity of greater than 7 degrees. Infection was eradicated in all but 1 patient who refused further treatment. Limb length inequality of greater than 2.5 cm was seen in 10 patients at the end of treatment period. These patients, despite counselling, were non-compliant for the distraction schedule given; they were satisfied with the length achieved and wanted no further distraction. There was one refracture at the docking site after mobilization, and this was managed non-operatively. No patient had premature consolidation, complex regional pain syndrome, persistent oedema or neurovascular complications on completion of treatment.
Discussion
Treatment for infected non-union improved with the use of the Ilizarov technique and the principle of distraction histogenesis. The principle of tension-stress describes the response of tissue when put under gradual stretch, in certain conditions, leads to generation of new tissue (bone, muscle, tendon, nerve, fascia, vessels, skin and its appendages) [19].
The Ilizarov technique produces an increase in the blood supply of the affected bone through biological stimulation at the corticotomy site, but a meticulous debridement is needed to reduce the infection load. In osteomyelitis, debridement and sequestrectomy produces a bone gap. The use of external fixation in managing infected non-union is established [20, 21]. However, the external fixators, without additional methods, do not solve the bone defect problem. The Ilizarov technique removes the bone defect through distraction at the corticotomy site and consequent new bone formation by intramembranous ossification, thus bridging the bone gap. The Ilizarov fixator is stable mechanically and permits axial compression during physiological loading [22]. This technique is a proven method of managing infected and gap non-unions in the femur and tibia [23–25].
The Ilizarov fixator uses wires and circular rings; this, especially in the proximal femur, leads to significant patient discomfort. When used for long periods in the treatment of infected non-unions, there is poor patient compliance and tolerance. In addition, the circular fixator technique is technically complex and is associated with some complications [18]. The rail fixation system (S. H. Pitkar Orthotools, Pune, India) is a uniplanar, dynamised external fixator system based on the principle of distraction histogenesis. The mechanical stability is provided by the tapered pins and variable placement of sliding clamps. In being uniplanar, it cannot be used easily to correct three-dimensional deformities as with a circular fixator but, conversely, allows easy access for secondary plastic surgical procedures. It is more patient-friendly; compression and distraction across a fracture or osteotomy site is simpler than with a circular external fixator [26].
Knee stiffness is not a complication of fixator application always. This disability may arise from the fracture, soft tissue damage, pre-existing stiffness and the presence of infection [2]. Use of the rail fixation system, especially with bone transport and or limb length equalisation, can produce knee stiffness. It is important that intensive physiotherapy follows application of this fixator in the femur.
The limitations of this study include the absence of a control group which gives comparative results. The heterogeneous group of patients in the study (age 7–70 years and gender with 35 males and 5 females) makes firm conclusions difficult as responses to trauma, infection and subsequent healing differ [27, 28]. The monolateral rail was found to be effective in managing infected gap non-unions of the femur and tibia; simplicity, ease of use with better patient compliance make it a preferred choice over the circular fixator except for complex three-dimensional deformity corrections.
References
Struijs PA, Poolman RW, Bhandari M (2007) Infected nonunion of the long bones. J Orthop Trauma 21:507–511
Ueng SW, Wei FC, Shih CH (1999) Management of femoral diaphyseal infected nonunion with antibiotic beads local therapy, external skeletal fixation, and staged bone grafting. J Trauma 46:97–103
Cabenela ME (1984) Open cancellous bone grafting of infected bone defects. Orthop Clin N Am 15:427
Gordon L, Chin EJ (1988) Treatment of infected nonunion and segmental defect of tibia with staged microvascular muscle transplantation and bone grafting. J Bone Joint Surg Br 70A:377–386
Marsh JL, Prokuski L, Biermann JS (1994) Chronic infected tibial nonunions with bone loss: conventional techniques versus bone transport. Clin Orthop Relat Res 301:139–146
Saridis A, Panagiotopoulos E, Tyllianakis M et al (2006) The use of the Ilizarov method as a salvage procedure in infected nonunion of the distal femur with bone loss. J Bone Joint Surg Br 88B:232–237
Grivas TB, Magnissalis EA (2011) The use of twin-ring Ilizarov external fixator constructs: application and biomechanical proof of principle with possible clinical indications. J Orthop Surg Res 6:41
Moss DP, Tejwani NC (2007) Biomechanics of external fixation: a review of the literature. Bull NYU Hosp Joint Dis 65:294–299
Fragomen AT, Rozbruch SR (2007) The mechanics of external fixation. HSS J 3:13–29
Belhan O, Ekinci A, Karakurt L et al (2008) The treatment of femoral shaft fractures in adults with hybrid Ilizarov external fixator. Joint Dis Relat Surg 19:50–54
Green SA, Harris NL, Wall DM et al (1992) The Rancho mounting technique for the Ilizarov method—a preliminary report. Clin Orthop Relat Res 280:104–116
Mahran MA, Elgebeily MA, Ghaly NA et al (2011) Pelvic support osteotomy by Ilizarov’s concept: is it a valuable option in managing neglected hip problems in adolescents and young adults? Strateg Trauma Limb Reconstr 6:13–20
Charalambous CP, Akimau P, Wilkes RA (2009) Hybrid monolateral-ring fixator for bone transport in post-traumatic femoral segmental defect: a technical note. Arch Orthop Trauma Surg 129:225–226
Inan M, Bomar JD, Kucukkaya M et al (2004) A comparison between the use of a monolateral external fixator and the Ilizarov technique for pelvic support osteotomies. Acta Orthop Traumatol Turc 38:252–260
Rosen H (1998) Nonunion and malunion. In: Browner BD, Levine AM, Jupitar JB (eds) Skeletal trauma: fractures, dislocations, ligamentous injuries. WB Saunders, Philadelphia, pp 501–541
Heckman JD, Ryaby JP, McCabe J et al (1994) Acceleration of tibial fracture healing by non-invasive, low intensity pulsed ultrasound. J Bone Joint Surg Am 76:26–34
Paley D, Catagni MA, Argnani F et al (1989) Ilizarov treatment of tibial nonunions with bone loss. Clin Orthop Relat Res 241:146–165
Paley D (1990) Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res 250:81–104
Ilizarov GA (1992) The tension-stress effect on the genesis and growth of tissues. In: Green SA (ed) Transosseous osteosynthesis: theoretical and clinical aspects of the regeneration and growth of tissue. Springer, Berlin, pp 137–256
Slatis P, Paavolainen P (1985) External fixation of infected non-union of the femur. Injury 16:599–604
Barquet A, Silva R, Massaferro J et al (1988) The AO tubular external fixator in the treatment of open fractures and infected non-unions of the shaft of the femur. Injury 19:415–420
Association for the Study and Application of the Method of Ilizarov Group (1991) Non-union of the femur. In: Bianchi-Maiocchi A, Aronson J (eds) Operative principles of Ilizarov. Fracture treatment, non-union, osteomyelitis, lengthening, deformity correction. Lippincott Williams and Wilkins, Baltimore
Cattaneo R, Catagni M, Johnson EE (1992) The treatment of infected nonunions and segmented defects of the tibia by the methods of Ilizarov. Clin Orthop Relat Res 280:143–152
Dendrinos GK, Kontos S, Lyritsis E (1995) Use of the Ilizarov technique for treatment of non-union of the tibia associated with infection. J Bone Joint Surg Am 77:835–846
Barbarossa V, Matkovic BR, Vucic N et al (2001) Treatment of osteomyelitis and infected non-union of the femur by a modified Ilizarov technique: follow-up study. Croat Med J 42:634–641
Eralp L, Kocaoglu M, Bilen FE et al (2010) A review of problems, obstacles and sequelae encountered during femoral lengthening: uniplanar versus circular external fixator. Acta Orthop Belg 76:628–635
Plowden J, Renshaw-Hoelscher M, Engleman C et al (2004) Innate immunity in aging: impact on macrophage function. Aging Cell 3:161–167
Gee AC, Sawai RS, Differding J et al (2008) The influence of sex hormone on coagulation and inflammation in the trauma patients. Shock 29:334–341
Funding
The authors declare that no financial support was received for this study, and this work was not supported by any means.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest.
Ethical approval
The study was approved by the institutional ethics committee.
Informed consent
Informed written consent was obtained from all the patients or their guardians.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Mudiganty, S., Daolagupu, A.K., Sipani, A.K. et al. Treatment of infected non-unions with segmental defects with a rail fixation system. Strat Traum Limb Recon 12, 45–51 (2017). https://doi.org/10.1007/s11751-017-0278-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11751-017-0278-6