Abstract
Background
Aortoenteric fistula (AEF), occasionally reported as a fatal complication after aortic or other vascular procedures, is a communication between the aorta and the digestive tract. AEF as a fatal complication of overlap esophagojejunostomy after esophagogastrectomy has not been reported previously. Herein, we report a case of AEF after laparoscopic proximal gastrectomy and transhiatal lower esophagectomy for cancer of the esophagogastric junction, in which linear staplers were used for overlap esophagojejunostomy.
Case presentation
A 66-year-old woman with advanced cancer of the esophagogastric junction underwent laparoscopic proximal gastrectomy and transhiatal lower esophagectomy with abdominal and lower mediastinal lymphadenectomy. Double tract reconstruction by the overlap method was performed. The patient was discharged from the hospital 10 days after surgery with a good postoperative course. However, she developed sudden-onset massive hematemesis and melena the day after discharge, resulting in death. Autopsy revealed that the stapled edge of the entry hole of the overlap esophagojejunostomy was in direct contact with the descending aorta. AEF was found at the esophagojejunostomy site.
Conclusions
To our knowledge, this is the first report of AEF as a fatal complication of overlap esophagojejunostomy after esophagogastrectomy. Although we could not definitively identify the cause of the AEF, it could be attributed to direct contact between the stapled edge and the bare thoracic aorta over a period of 10 days. To avoid direct contact with the aorta in esophagojejunostomy with linear staplers, all stapled edges should be covered by suturing and attention should be paid to the position of these edges.
Similar content being viewed by others
Background
Esophagojejunostomy using linear staplers (overlap method) after laparoscopic total gastrectomy for gastric cancer was first reported by Inaba et al. [1]. To date, several reports have stated that overlap esophagojejunostomy is a safe and useful method after laparoscopic total gastrectomy [2,3,4]. One rare report has detailed good postoperative outcomes of seven patients after esophagogastrectomy with radical lymphadenectomy in the lower mediastinum followed by overlap esophagojejunostomy [5]. Aortoenteric fistula (AEF) at the site of overlap esophagojejunostomy after laparoscopic total gastrectomy has been reported in the literature [6]. Herein, we report a case of AEF at the esophagojejunostomy site after laparoscopic esophagogastrectomy for cancer of the esophagogastric junction (EGJ), which is a rare, fatal complication involving the development of a fistula between the aorta and digestive tract. The present case report demonstrates the possible association between the overlap esophagojejunostomy with linear staplers and AEF.
Case presentation
A 66-year-old Japanese woman was referred to our hospital with complaints of vomiting. Endoscopic upper gastrointestinal imaging revealed a type 3 tumor at the EGJ (circumference, 56 mm) with stenosis. The epicenter was 3 mm from the EGJ on the gastric side. Computed tomography (CT) showed lymph node metastases along the lesser curvature of the stomach and the proximal splenic artery. The patient was diagnosed with a cT4aN2M0, cStage IIIC lesion according to the Union for International Cancer Control’s TNM classification [7].
Operative findings
Laparoscopic proximal gastrectomy with abdominal lymphadenectomy was performed. After the diaphragm was separated from the hiatus using a linear stapler, radical lymph node dissection in the lower mediastinum was performed. The esophagus was latitudinally dissected with a linear stapler via a left 8th intercostal trocar. Double tract reconstruction by intrathoracic overlap method was performed using linear staplers (Fig. 1). A side-to-side anastomosis was created between the right side of the esophagus and jejunal limb, and the jejunal staples were extracorporeally covered by seromuscular sutures. Finally, the entry hole was closed intracorporeally using the interrupted hand-sewn technique [4, 8].
Histopathological findings
The tumor was histopathologically diagnosed as a moderately to poorly differentiated squamous cell carcinoma of the EGJ. Lymph node metastases were found in 22 of 50 removed nodes, and the pathological stage was pT3N3aM0, stage IIIB according to the Japanese Gastric Cancer Association Classification 14th. R0 resection was achieved.
Postoperative course
On postoperative day (POD) 2, upper gastrointestinal series revealed no leakage of the esophagojejunostomy (Fig. 2). The patient resumed normal diet on POD 3 and was discharged on POD 10. However, on the next day, she developed melena followed by massive hematemesis and was transferred to our hospital in cardiopulmonary arrest. Post-mortem CT revealed that the dorsal stapled edge of the entry hole was in direct contact with the bare descending aorta (Fig. 3). An AEF at the esophagojejunostomy site was revealed on autopsy (Fig. 4). Neither hemorrhage nor major abscess was observed in the thoracic and abdominal cavities. Microscopic findings demonstrated a fine tract from the adventitia to the intima of the descending aorta. There were only a few neutrophils in the intima of the aortic wall (Fig. 5). These findings indicated that the fistula was created by direct contact of the stapled edge and not by any adjacent abscess due to leakage of the anastomosis. The cause of death was considered to be hemorrhagic shock due to AEF.
Discussion
AEFs are abnormal communications between the aorta and bowel and are commonly caused by thoracic aortic aneurysms, esophageal foreign bodies, esophageal cancers, and post-vascular surgical complications [9, 10]. Open total gastrectomy is commonly associated with anastomotic leakage, pancreatic fistula, abdominal abscess, intestinal obstruction, and pneumonia, with AEF being a rare complication [11,12,13]. Overlap esophagojejunostomy has been reported to be a safe and useful technique in laparoscopic total gastrectomy [1,2,3, 8]. Gunji et al. reported a case of AEF after laparoscopic total gastrectomy with overlap esophagojejunostomy for advanced gastric cancer with esophageal invasion [6]. In the reported case, bacterial peritonitis was diagnosed 5 days after the operation, manifesting as partial necrosis and perforation of the small intestine. The patient was treated successfully with laparoscopic partial resection of the small intestine, but unfortunately died of massive hematemesis due to AEF 30 days after her initial procedure. The authors hypothesized that AEF could have resulted from persistent contact and subsequent abrasion by the staple line on the aortic wall.
In our case, autopsy revealed the dorsal stapled edge of the entry hole located on the surface of the descending aorta (Fig. 4). The microscopic findings demonstrated a fine tract from the adventitia to the intima of the aorta, where the EGJ staple was stuck. The stapled edge was speculated to be exposed outside the anastomosis owing to the interrupted hand-sewn technique without inverting the stapled edges inside. The causes of the AEF were considered to be the sustained contact between the exposed staple and aorta and the power of each heartbeat. The position of the jejunal limb was on the right side of the esophagus, and the dorsal staple was in contact with the aorta owing to inadequate mobilization of the thoracic esophagus (Fig. 1d).
Noshiro stated that some extraverted esophageal and intestinal stumps in the thorax should be covered by suturing to prevent the formation of pulmonary fistulas, although AEF was not mentioned [5]. Gunji et al. reported an AEF located above a triangular anastomosis between the esophagus, jejunal limb, and the descending aorta [6]. They speculated that the persistent contact of the staple line eroded the aortic wall, leading to AEF. We suggest that all staples should be covered with suturing to prevent contact with the aorta. A side-to-side anastomosis could be created between the dorsal side of the esophagus and the jejunal limb, forming a cushion between the staples and the aorta.
Conclusions
In this report, we describe a rare case of AEF, a lethal complication post-esophagojejunostomy with linear stapler after laparoscopic esophagogastrectomy. Although we could not definitively identify the cause of the AEF, it could be attributed to the direct contact between the stapled edge and the bare thoracic aorta over a period of 10 days. To avoid direct contact with the bare aorta during anastomosis with linear staplers, all stapled edges should be covered by suturing, and attention should be paid to the position of the jejunal limb.
Abbreviations
- AEF:
-
Aortoenteric fistula
- EGJ:
-
Esophagogastric junction
- POD:
-
Postoperative day
References
Inaba K, Satoh S, Ishida Y, Taniguchi K, Isogaki J, Kanaya S, et al. Overlap method: novel intracorporeal esophagojejunostomy after laparoscopic total gastrectomy. J Am Coll Surg. 2010;211:e25–9.
Kitagami H, Morimoto M, Nakamura K, Watanabe T, Kurashima Y, Nonoyama K, et al. Technique of Roux-en-Y reconstruction using overlap method after laparoscopic total gastrectomy for gastric cancer: 100 consecutively successful cases. Surg Endosc. 2016;30:4086–91.
Morimoto M, Kitagami H, Hayakawa T, Tanaka M, Matsuo Y, Takeyama H. The overlap method is a safe and feasible for esophagojejunostomy after laparoscopic-assisted total gastrectomy. World J Surg Oncol. 2014;12:392.
Yamamoto M, Zaima M, Yamamoto H, Harada H, Kawamura J, Yamaguchi T. A modified overlap method using a linear stapler for intracorporeal esophagojejunostomy after laparoscopic total gastrectomy. Hepato-Gastroenterology. 2014;61:543–8.
Noshiro H, Miyasaka Y, Akashi M, Iwasaki H, Ikeda O, Uchiyama A. Minimally invasive esophagogastrectomy for esophagogastric junctional cancer. Ann Thorac Surg. 2012;93:214–20.
Gunji S, Okabe H, Obama K, Sakai Y. Aortoenteric fistula at the site of esophagojejunostomy after laparoscopic total gastrectomy: report of a case. Surg Today. 2014;44:2162–6.
Rice TW, Blackstone EH, Rusch VW. 7th edition of the AJCC Cancer Staging Manual: esophagus and esophagogastric junction. Ann Surg Oncol. 2010;17(7):1721–4.
Tsujimoto H, Uyama I, Yaguchi Y, Kumano I, Takahata R, Matsumoto Y, et al. Outcome of overlap anastomosis using a linear stapler after laparoscopic total and proximal gastrectomy. Langenbeck’s Arch Surg. 2012;397:833–40.
Goshtasby P, Henriksen D, Lynd C, Fielding LP. Recurrent aortoenteric fistula: case report and review. Curr Surg. 2005;62:638–43.
Parikh MP, Sherid M, Panginikkod S, Rawal HA, Gopalakrishnan V. Radiation therapy-induced aortoesophageal fistula: a case report and review of literature. Gastroenterol Rep (Oxf). 2016;4:165–7.
Sasako M, Sano T, Yamamoto S, Sairenji M, Arai K, Kinoshita T, et al. Left thoracoabdominal approach versus abdominal-transhiatal approach for gastric cancer of the cardia or subcardia: a randomised controlled trial. Lancet Oncol. 2006;7:644–51.
Sano T, Sasako M, Yamamoto S, Nashimoto A, Kurita A, Hiratsuka M, et al. Gastric cancer surgery: morbidity and mortality results from a prospective randomized controlled trial comparing D2 and extended para-aortic lymphadenectomy--Japan Clinical Oncology Group study 9501. J Clin Oncol. 2004;22:2767–73.
Bonenkamp JJ, Songun I, Hermans J, Sasako M, Welvaart K, Plukker JT, et al. Randomised comparison of morbidity after D1 and D2 dissection for gastric cancer in 996 Dutch patients. Lancet. 1995;345:745–8.
Acknowledgements
We would like to thank Editage (www.editage.jp) for English language editing.
Funding
No specific funding was disclosed.
Author information
Authors and Affiliations
Contributions
MH and TS drafted this manuscript. MH, SK, YY, and DK participated in the treatment of the patient. FO was responsible for the pathological examinations. KY revised the article. All authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Authors’ information
Six authors are Board Certified Surgeons in Gastroenterology and are affiliated to the Department of Surgery, Sainokuni Higashiomiya Medical Center, Saitama, Saitama, Japan. MH, TS, and KY are qualified surgeons involved in endoscopic surgical skill qualification system, and DK is the Chief Director. FO is the Director of Department of Pathology, Sainokuni Higashiomiya Medical Center, Saitama, Saitama, Japan.
Ethics approval and consent to participate
Not applicable.
Consent for publication
Written informed consent was obtained from the patient’s husband for the publication of this case report and any accompanying images.
Competing interests
All authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Honda, M., Sakamoto, T., Kojima, S. et al. Aortoenteric fistula following overlap esophagojejunal anastomosis using linear staplers for cancer of the esophagogastric junction: a case report. surg case rep 5, 9 (2019). https://doi.org/10.1186/s40792-019-0566-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s40792-019-0566-0