Abstract
Objectives
To investigate the model-, code-, and data-sharing practices in the current radiomics research landscape and to introduce a radiomics research database.
Methods
A total of 1254 articles published between January 1, 2021, and December 31, 2022, in leading radiology journals (European Radiology, European Journal of Radiology, Radiology, Radiology: Artificial Intelligence, Radiology: Cardiothoracic Imaging, Radiology: Imaging Cancer) were retrospectively screened, and 257 original research articles were included in this study. The categorical variables were compared using Fisher’s exact tests or chi-square test and numerical variables using Student’s t test with relation to the year of publication.
Results
Half of the articles (128 of 257) shared the model by either including the final model formula or reporting the coefficients of selected radiomics features. A total of 73 (28%) models were validated on an external independent dataset. Only 16 (6%) articles shared the data or used publicly available open datasets. Similarly, only 20 (7%) of the articles shared the code. A total of 7 (3%) articles both shared code and data. All collected data in this study is presented in a radiomics research database (RadBase) and could be accessed at https://github.com/EuSoMII/RadBase.
Conclusion
According to the results of this study, the majority of published radiomics models were not technically reproducible since they shared neither model nor code and data. There is still room for improvement in carrying out reproducible and open research in the field of radiomics.
Clinical relevance statement
To date, the reproducibility of radiomics research and open science practices within the radiomics research community are still very low. Ensuring reproducible radiomics research with model-, code-, and data-sharing practices will facilitate faster clinical translation.
Key Points
• There is a discrepancy between the number of published radiomics papers and the clinical implementation of these published radiomics models.
• The main obstacle to clinical implementation is the lack of model-, code-, and data-sharing practices.
• In order to translate radiomics research into clinical practice, the radiomics research community should adopt open science practices.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Radiomics is an image analysis method that makes it possible to discover more than what can be seen with the naked eye, and it is a rapidly growing field of research [1]. Since its first appearance in the literature [2], thousands of articles have been published [3]. At the turn of a new decade of radiomics research, the clinical translation of radiomics models still lags far behind [3]. One of the main reasons for this chasm between research and clinical implementation is the lack of reproducibility. Shortage of clinical data- or radiomics model-sharing practices in the field further complicates the achievement of this goal [4]. This trend resembles the reproducibility crisis in the field of psychology, where independent researchers attempted to replicate results of previously published prominent articles, but succeeded only 30% of the time [5]. Open science practices [6, 7], i.e., data and code sharing, are important steps to overcome these challenges, as they enable more researchers to independently test proposed methods on an independent dataset.
With the development of checklists such as CheckList for EvaluAtion of Radiomics research (CLEAR) [8], the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) [9], or Must AI Criteria 10 Checklist (MAIC-10) [10], code and data sharing in radiomics and artificial intelligence (AI) research is increasingly encouraged. Despite the fact that these practices are being promoted, they may not be necessarily sufficient for reproducibility, i.e., authors may only share “pseudocode” that is only a representation of the main code, or there may be errors in the code even though it is fully shared [11]. This trend can also be observed in AI research in radiology: According to a recent article, data were released in only 13% of AI papers, code was shared in only 34%, and only 33% of shared code was reproducible [12].
In the absence of a universally accepted definition of reproducibility, in this paper, we accept the earlier description of “research reproducibility” [13, 14]. Namely, research is reproducible if the same results are obtained when the same data, code, and method are used, and research is replicable if the same results are obtained when the same method and code are applied on an independent dataset. Considering these definitions, reproducibility is the minimum criterion for generalizable radiomics research [14].
In this paper, we have explored the practices of sharing model, code, and data in the current radiomics research landscape. Along with presenting our findings in this paper, we also introduce a large radiomics research database to facilitate the retrieval of radiomics models, code, and data if shared. We believe the radiomics research database will help researchers disseminate scientific knowledge and pave the way for clinical implementation, and we hope that this will encourage more researchers to share their model, code, and data. We will continue to expand the radiomics research database and call on interested researchers to help us in this endeavour.
Material and methods
Article selection and screening
A retrospective search using the following string was in the PubMed and Embase databases: (“radiomics”[Title/Abstract] OR “radiomic”[Title/Abstract]) AND (“Radiology”[Journal] OR “Radiology Artificial Intelligence”[Journal] OR “European Radiology”[Journal] OR “European Journal of Radiology”[Journal]) AND 2021/01/01:2021/12/31[Date—Publication].
All articles published between January 1, 2021, and December 31, 2022, were reviewed to identify the original research studies using “radiomics” or “radiomic” keywords in the title or abstract. We randomly selected leading first quarter (Q1) journals from Europe and the USA, namely European Radiology, European Journal of Radiology, Radiology, Radiology: Artificial Intelligence, Radiology: Cardiothoracic Imaging, and Radiology: Imaging Cancer. First, articles that were not original, i.e., systematic reviews, meta-analyses, literature reviews, editorials, letters, and corrections, were excluded by article type, title, and abstract screening. Second, technical studies testing robustness of features and external validation studies validating previously published models were also excluded by full-text screening (Fig. 1).
All studies were screened by four radiologists (T.A.D., 6 years of experience in research and radiology; D.P.d.S., 13 years of experience in research and radiology; R.C., 11 years of experience in research and radiology; B.B., 12 years of experience in research and radiology).
Article characteristics
Four raters then extracted the following data from selected articles: article title, digital object identifier (DOI), journal title, first author, correspondence address, country, study design, main topic, subtopic, modality, model method, model shared or not, link to model, data shared or not, link to data, code shared or not, and link to code. The raters were also responsible for reviewing the code or data if shared. We explicitly only considered internal validation available if done on a hold-out set because that would be more useful in terms of clinical relevance. When a study used only cross-validation for internal validation, it was considered as a study that did not meet the criterion for internal validation, as no independent test data was available. If cross-validation is to be used alone, the entire pipeline must be nested, or a test set should be left out of the pipeline to obtain unbiased results; otherwise, the model will be overfitted and cannot be generalized [15, 16]. The studies that used a public dataset were considered to have shared the data. Disagreements between raters were resolved by consensus, if any.
Statistical analysis
Descriptive statistics were used to summarize article characteristics as well as code- and data-sharing practices. A comparison of categorical variables was performed using the Fisher exact test or chi-square test and numerical variables using Student’s t test. Results were also compared between publication years 2021 and 2022. All analyses were performed with STATA program (IC version 15.1). The alpha value was set to 0.05.
Results
Article screening and characteristics
A total of 257 original research articles that describe the development and evaluation of a new radiomics model were included in this study (Fig. 1). Most of the included articles were published in European Radiology (76%; 195 of 257), followed by European Journal of Radiology (17%; 44 of 257). The total number of published articles increased from 106 in 2021 to 151 in 2022 (Table 1).
Most of the articles were from China (68%; 175 of 257), followed by the Republic of Korea (7%; 19 of 257) and the USA (6%; 16 of 257) (Fig. 2). Most of the included articles focused on chest (20%; 52 of 257) and abdominal radiology (20%; 52 of 257). The main modalities used in the included studies were CT (42%; 109 of 257) and MRI (42%; 110 of 257). The study design was mainly retrospective (96%; 249 of 257). Only 4% (8 of 257) of the included studies were prospective, and of the 8 studies, only 1 was a randomized controlled trial. Interestingly, we found that one retrospective study was incorrectly reported as a prospective study because the model was trained on a retrospective dataset but validated on a prospective dataset, i.e., temporal validation. In most cases, the model was developed for classification tasks (56%; 144 of 257) and the second most commonly for prognostication tasks (30%; 79 of 257) (Table 1).
Open science practices
To evaluate the reproducibility of radiomics research in this study, we adapted a previously proposed reproducibility classification framework [17]: statistical reproducibility, i.e., the validated model and details of modeling methods are shared; conceptual reproducibility, i.e., external validation is performed; and technical reproducibility, i.e., code and/or data are available. All results are shown in Tables 2 and 3.
Statistical reproducibility
Half of the articles (128 of 257) included either the final model formula or selected radiomics features along with their coefficients. We accepted that either approach was sufficient to meet the model-sharing requirements, and we observed no difference between the years 2021 and 2022 (p = 0.19). Of the 257 articles, two indicated that the model was shared in the supplement; however, upon assessment of all available supplementary material, no model was found; thus, for the purpose of our analysis, these were included as articles that did not share the model.
The most commonly used modelling method was least absolute shrinkage and selection operator or logistic regression (LASSO/LR; 54%; 139 of 257). Moreover, 72% (100 of 139) of the LASSO/LR models were shared. The second most common modelling method was using a combination of several machine learning (ML) classifiers, e.g., K-nearest neighbour (KNN), Naïve-Bayes, ElasticNet, Gradient Boosting Decision Tree (XGBoost), and AdaBoost; 64 of 257 (25%) and 15 of 64 (23%) ML models were shared. Most commonly sole used machine learning classifiers were random forest (RL; 7%; 20 of 257) and support vector machine (SVM; 7%; 20 of 257) and 4 of 20 (20%) RF and 7 of 20 (35%) of SVM models were shared. Only 4% of the modelling methods was deep learning (DL; 11 of 257) and only 2 of 11 (18%) DL models were shared. Interestingly, in 3 of the 257 articles, the researchers indicated no modelling method at all (1%).
Most of the papers validated the model on a hold-out set internally (71%; 182 of 257), and this practice did not change between the years 2021 and 2022 (p = 0.41). We noted some researchers performed only cross-validation (6%; 16 of 257) rather than validating their model on a hold-out set, and hence, as detailed above for the purpose of this manuscript, this approach was assessed as not having internal validation. The number of papers using only cross-validation increased from 1 to 15 from 2021 to 2022 (p = 0.018).
Conceptual reproducibility
Only 28% (73 of 257) of the models were externally validated on an independent dataset, and the number of externally validated models has increased from 23 to 50 within one year (p = 0.046).
Technical reproducibility
Only 6% (16 of 257) of the included articles shared the data or used publicly available open datasets. Similarly, only 7% (20 of 257) of the articles included a link to the code used for data analysis. Of the 20 articles with a link to the code, one included only pseudocode. Only 3% (7 of 257) of articles both shared code and data at the same time.
Table 3 shows a breakdown of the number of articles sharing code and data by the journal.
Radiomics research database (RadBase)
As a first step, the collected data in this article has been made available as a comma-separated value (CSV) file, but we hope to be able to add and refine more data in the near future continuously. We have chosen to make the database available on GitHub as this allows interaction, e.g., if a researcher wants to update fields pertaining to their study or if others want to contribute new entries, this can be done via issues or pull requests. In the future, authors and journals could also proactively register their studies in the database with a link to the code before or after the publication.
For this first version of the database, we have provided instructions for accessing the CSV file directly so that researchers can create scripts to notify them of updates.
Our initial database, RadBase, containing all information from the articles we included in this study can be accessed at https://github.com/EuSoMII/RadBase.
Discussion
In this study, we found that most radiomics studies did not share code or data; in other words, most radiomics models were not reproducible. To our surprise, the authors tend to share their validated model with an extensive model-building methodology; however, only around 30% of the models were conceptually reproducible as they were validated on an external dataset. In this study, we also introduced a searchable radiomics research database (RadBase). To our knowledge, there has been only one such initiative within the AI research community: the Papers with Code website shares papers that contain links to code to promote code sharing [18]. With the proposed radiomics database, we aim to promote all facets of reproducible radiomics research and achieve broader acceptance within the radiomics community.
Despite the growing number of guidelines encouraging open science practices in radiomics research, our results show that the radiomics research community still lags far behind. In addition, some researchers find a way to circumvent checklists and guidelines by intentionally or unintentionally sharing broken links, empty GitHub repositories, incomplete code, or data that never allow published methods to be truly reproduced [12]. In this study, we also observed practices such as misleading statements, e.g., reporting that the model is in the supplement but it was not [19, 20], and sharing only pseudocode [21] that does not allow to reproduce proposed model. To avoid these issues, not only code or data sharing but also reproducible code sharing is encouraged by major artificial intelligence congresses such as Neural Information Processing Systems (NeuroIPS) with the Machine Learning Reproducibility checklists [22].
At the turn of a decade, we should embark on reproducible radiomics research if we do not want to spend another decade waiting for clinical implementation. We should also ensure that decades later our methodology can withstand the challenges that come with the ever-changing technologies. The results of a recent initiative to determine whether the code that researchers wrote 10 years ago still works [23] can serve as a cautionary tale. While some of the researchers were able to get 10-year-old code to work, even when the data had to be transferred from a floppy disk to the cloud, the majority of them (80%) did not work [24]. Unfortunately, our results over the last 2 years point in the same direction—most of the radiomics models were technically not reproducible. In an ever-growing field of radiomics research, as we adopt open science practices, we should also make sure that our methods persist over time.
Similar to a previous study [12], we observed that authors who were required to make a data- and code-sharing statement were more likely to share their data and code openly. Promoting reproducibility thorough journal standards, checklists, and badges could enable the widespread adoption of open science practices [25]. Moreover, this could be as simple as requesting a statement to do so [6]. Journals could adopt the proposed model of standards for reproducibility to reward these practices accordingly on a sliding scale [6, 25]. Evidently, the model and code have to be submitted with the manuscript to ensure reproducibility. However, an exception may be made if the authors can demonstrate that they wish to protect their intellectual property for a while, but if they fail to do so within a reasonable time frame, the manuscript should be withdrawn or modified. Clearly, patient privacy issues could hinder data sharing in healthcare, but this could be easily overcome by sharing data through databases with strict data use agreements.
Our study had some limitations. First, we only included a selection of articles from leading journals that were recently published. Therefore, our results might not be generalizable to the rest of the radiomics literature. Even if we were able to show that publications in some of the highest-ranked journals from Europe and the USA only rarely followed open-science practices, this result could be different in other journals from different parts of the word (e.g., the journals from the Asia–Pacific region). Secondly, we did not technically control if the shared model is reproducible or not, but we encourage researchers to join our efforts and use our database for the planning and execution of validation studies. Finally, although we did not extract data on methodological details of the entire study pipeline in this study, e.g., postprocessing methods, feature extraction techniques, feature normalization, or harmonization methods, these details could also affect the reproducibility of the study and should be properly reported. Therefore, we encourage researchers to share data not only concerning statistical, conceptual, or technical reproducibility, such as we collected in this study, but also the data on the whole pipeline in our database.
In conclusion, there is room for improvement regarding reproducibility in radiomics research. We urge researchers to adopt open science practices to ensure reproducible radiomics research now and in the future.
Abbreviations
- AI:
-
Artificial intelligence
- CLAIM:
-
Checklist for Artificial Intelligence in Medical Imaging
- CLEAR:
-
CheckList for EvaluAtion of Radiomics research
- CSV:
-
Comma-separated value
- DOI:
-
Digital object identifier
- KNN:
-
K-nearest neighbor
- LASSO/LR:
-
Least absolute shrinkage and selection operator or logistic regression
- MAIC-10:
-
Must AI Criteria 10 Checklist
- ML:
-
Machine learning
- NeuroIPS:
-
Neural Information Processing Systems
- Q1:
-
First quarter
- RF:
-
Random forest
- SVM:
-
Support vector machine
- XGBoost:
-
Gradient Boosting Decision Tree
References
Gillies RJ, Kinahan PE, Hricak H (2016) Radiomics: images are more than pictures, they are data. Radiology. https://doi.org/10.1148/radiol.2015151169
Lambin P, Rios-Velazquez E, Leijenaar R et al (2012) Radiomics: extracting more information from medical images using advanced feature analysis. Eur J Cancer. https://doi.org/10.1016/j.ejca.2011.11.036
Pinto dos Santos D, Dietzel M, Baessler B (2020) A decade of radiomics research: are images really data or just patterns in the noise? Eur Radiol. https://doi.org/10.1007/s00330-020-07108-w
Sardanelli F, Alì M, Hunink MG et al (2018) To share or not to share? Expected pros and cons of data sharing in radiological research. Eur Radiol. https://doi.org/10.1007/s00330-017-5165-5
Open Science Collaboration (2015) Estimating the reproducibility of psychological science. Science. https://doi.org/10.1126/science.aac4716
Nosek BA, Alter G, Banks GC et al (2015) Promoting an open research culture. Science. https://doi.org/10.1126/science.aab2374
Hicks DJ (2021) Open science, the replication crisis, and environmental public health. Account Res. https://doi.org/10.1080/08989621.2021.1962713
Kocak B, Baessler B, Bakas S et al (2023) CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII. Insights Imaging. https://doi.org/10.1186/s13244-023-01415-8
Mongan J, Moy L, Kahn CE (2020) Checklist for Artificial Intelligence in Medical Imaging (CLAIM): a guide for authors and reviewers. Radiol Artif Intell. https://doi.org/10.1148/ryai.2020200029
Alberich LC, Solana J, Mallol P et al (2023) MAIC – 10 brief quality checklist for publications using artificial intelligence and medical images. Insights Imaging. https://doi.org/10.1186/s13244-022-01355-9
Kitamura FC, Pan I, Kline TL (2020) Reproducible Artificial Intelligence Research Requires Open Communication of Complete Source Code. Radiol Artif Intell 2:4 https://doi.org/10.1148/ryai.2020200060
Venkatesh K, Santomartino SM, Sulam J, Yi PH (2022) Code and data sharing practices in the radiology artificial intelligence literature: a meta-research study. Radiol Artif Intell. https://doi.org/10.1148/ryai.220081
Goodman SN, Fanelli D, Ioannidis JPA (2018) What does research reproducibility mean? Sci Transl Med 8:341ps12. https://doi.org/10.1126/scitranslmed.aaf5027
Beam AL, Manrai AK, Ghassemi M (2020) Challenges to the reproducibility of machine learning models in health care. JAMA. https://doi.org/10.1001/jama.2019.20866
Varma S, Simon R (2006) Bias in error estimation when using cross-validation for model selection. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-7-91
Rao RB, Fung G, Rosales R (2008) On the dangers of cross-validation. An experimental evaluation. Soc Ind Appl Math - 8th SIAM Int Conf Data Min 2008, Proc Appl Math. 588-596. https://doi.org/10.1137/1.9781611972788.54
McDermott MBA, Wang S, Marinsek N et al (2019) Reproducibility in machine learning for health. RML@ICLR 2019 Work - Reprod Mach Learn. https://doi.org/10.48550/arXiv.1907.01463
Papers with code website. Available via https://paperswithcode.com. Accessed 23 Jan 2023
Lin Z, Tang B, Cai J et al (2021) Preoperative prediction of clinically relevant postoperative pancreatic fistula after pancreaticoduodenectomy. Eur J Radiol. https://doi.org/10.1016/j.ejrad.2021.109693
Lv X, Chen M, Kong C et al (2021) Construction of a novel radiomics nomogram for the prediction of aggressive intrasegmental recurrence of HCC after radiofrequency ablation. Eur J Radiol. https://doi.org/10.1016/j.ejrad.2021.109955
Lin FY, Chang YC, Huang HY et al (2022) A radiomics approach for lung nodule detection in thoracic CT images based on the dynamic patterns of morphological variation. Eur Radiol. https://doi.org/10.1007/s00330-021-08456-x
Pineau J, Vincent-Lamarre P, Sinha K et al (2021) Improving reproducibility in machine learning research (a report from the neurips 2019 reproducibility program). J Mach Learn Res. https://doi.org/10.48550/arXiv.2003.12206
Perkel JM (2020) Challenge to scientists: does your ten-year-old code still run? Nature. https://doi.org/10.1038/d41586-020-02462-7
Rougier NP, Hinsen K, Alexandre F et al (2017) Sustainable computational science: the ReScience Initiative. PeerJ Comput Sci. https://doi.org/10.7717/peerj-cs.142
Heil BJ, Hoffman MM, Markowetz F et al (2021) Reproducibility standards for machine learning in the life sciences. Nat Methods. https://doi.org/10.1038/s41592-021-01256-7
Acknowledgements
This study is a part of the EuSoMII Radiomics Auditing Initiative project.
Funding
Open access funding provided by University of Basel The authors state that this work has not received any funding.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Guarantor
The scientific guarantor of this publication is Daniel Pinto dos Santos.
Conflict of interest
Renato Cuocolo serves as a scientific editorial board member of European Radiology and has not taken part in the review and decision process of this paper.
Bettina Baessler received funding from the SPP2177 program of the German Research Foundation (Deutsche Forschungsgemeinschaft, ‘DFG’); speaker bureau of Bayer Vital GmbH; founder and CEO of Lernrad GmbH (the latter two not related to the project). She also serves as a social media deputy editor on the scientific editorial board member of European Radiology and has not taken part in the review and decision process of this paper.
Daniel Pinto dos Santos serves as deputy editor of European Radiology and has not taken part in the review and decision process of this paper. He received speaker fees from Bayer, Advisory Board member for cook medical.
The remaining author of this manuscript declares no relationships with any companies, whose products or services may be related to the subject matter of the article.
Statistics and biometry
No complex statistical methods were necessary for this paper.
Informed consent
Written informed consent was not necessary for this study because no human subjects were involved.
Ethical approval
Institutional review board approval was not required because no human subjects were involved.
Study subjects or cohorts overlap
Not applicable.
Methodology
• retrospective
• observational
• multicenter study
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Akinci D’Antonoli, T., Cuocolo, R., Baessler, B. et al. Towards reproducible radiomics research: introduction of a database for radiomics studies. Eur Radiol 34, 436–443 (2024). https://doi.org/10.1007/s00330-023-10095-3
Received:
Revised:
Accepted:
Published: