Abstract
Posterior column fractures are common acetabular injuries. Although displaced fractures require open reduction and fixation, undisplaced patterns may benefit from percutaneous screw fixation. The combination of iliac oblique with inlet and outlet views offers an intuitive and panoramic rendering of the bony corridor into the posterior column; lateral cross table view completes the sequence of fluoroscopic projections. Herein we describe the use of outlet/inlet iliac views and a detailed procedure for percutaneous retrograde posterior column screw fixation.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Open anatomical reduction and internal fixation is the standard of care for displaced fracture of the acetabulum [1]. Percutaneous screw fixation is related to satisfactory results in minimally displaced, non-comminuted acetabular fractures, particularly in patients with severe soft tissue injury and increased risk for major surgery [2,3,4,5,6].
The first description of the percutaneous technique advocated the use of supine decubitus and iliac/obturator and inlet/outlet views [3]; however, surgical steps of the procedure are not clearly described. Several studies have investigated acetabular bone corridors morphology and their anatomical variability [7,8,9]. The relationship between the ischial entry point and the sciatic nerve have been assessed [10]. Navigated and computer-assisted procedures have been developed and compared to traditional fluoroscopic guided techniques [11, 12]. A fluoroscopic-guided technique, performed in prone position, has been described into details, using obturator oblique, iliac oblique and outlet-obturator views [5]. However, supine decubitus is preferred for anaesthesiologic reasons and for easier combination with anterior components fixation.
Percutaneous retrograde posterior column screw fixation remains a challenging procedure and a clear consensus on which fluoroscopic views are most accurate and intuitive is still lacking.
Aim of this study is to present a detailed technique to perform percutaneous retrograde posterior column screw fixation in supine position, using a sequence of inlet and outlet -iliac and cross-table lateral views to assess the bony corridor inside the posterior column.
Methods
The patient is placed in a supine position on a flat radiolucent table. The ipsilateral lower limb is prepped free in a sterile fashion, in addition to the entire pelvic region, with special attention to the perineal area: a U-shaped drape should be positioned medial to the ischial tuberosity and lateral to the perineum. The draping should be reinforced with adhesive polyethylene sterile band to assure asepsis and stability of draping during hip hyperflexion. The image intensifier is placed contralateral to the injured side. The hip is flexed 90° and slightly externally rotated, to decrease tension on the sciatic nerve. Slight hip hyperflection can be performed to reduce pelvic inclination and facilitate guide wire positioning.
The ischial tuberosity is palpated, and a 10-mm incision is performed with a blade.
An outlet-iliac oblique view is obtained to assess the correct entry point and the corridor along the midline axis of the ischium. A 3.2 mm guide wire is inserted into the ischium and advanced few millimeters (Fig. 1).
An inlet-iliac oblique view is obtained to assess the corridor medial to the acetabular cavity and lateral to the greater sciatic notch. (Fig. 2). A cross table lateral view is obtained to assess guide wire position on the sagittal plane, to avoid penetration of the subcotyloid notch or retroacetabular surface (Fig. 3).
Outlet-iliac, inlet-iliac and cross table lateral views are sequentially obtained during guide wire insertion to assess its correct placement. Once the inner cortex of the iliac wing is reached, screw length is obtained with a dedicated measure. A cannulated 6.5-mm drill is used to open the ischial cortex and 8-mm partially threaded cannulated screw (Asnis III Cannulated Screw System, Stryker Corp. Kalamazoo, MI, USA) is implanted, under fluoroscopic control. The skin is closed with 2–0 nylon suture.
Postoperative radiograms are obtained to assess the correct position of the implant and joint congruity.
Results
Five patients underwent percutaneous retrograde posterior column screw fixation at our Institution (Table 1). Two patients had minimally displaced (< 1 mm) acetabular fractures (1 transverse, 1 anterior column + posterior hemi-transverse) and were treated with a completely percutaneous procedure. One patient had a combined pelvic and acetabulum injury and was treated with open reduction and fixation of the sacral injury, percutaneous retrograde right pubic ramus screw and percutaneous retrograde posterior column screw. The fourth patient had an anterior column posterior hemi-transverse (ACPHT) fracture and was treated with open reduction and plate fixation of the anterior column through an anterior intrapelvic approach; the anterior surgical step resulted in indirect reduction of the posterior column and fixation was achieved with a percutaneous retrograde screw. The fifth patient had a pelvic ring injury with an interruption of the low posterior column.
All reassumed full weight-bearing within 10 weeks. One patient had a migration of the screw that unscrew and protruded, impairing sitting. The screw was repositioned.
Postoperative radiographs and computed tomography (CT) scans showed correct screw placement in the posterior acetabular column. Follow-up imaging at 12 months showed fracture healing. None of the patients had neurological impairment. One of the patients showed initial pre-arthritic changes consisting in new femoral neck cam deformity.
Discussion
Percutaneous acetabular screw fixation has been described as an effective procedure to treat minimally displaced acetabular fractures. Posterior column retrograde fixation can be performed in conjunction with other percutaneous screw positioning or associated to open approaches, to limit the surgical exposure to one open approach. This is particularly relevant in ACPHT fractures, when reduction of the posterior column is performed through an anterior approach.
The bony corridor geometry and variability have been assessed in anatomical and imaging studies. Relationship with neurovascular structures have been investigated.
However, percutaneous posterior column retrograde screw fixation remains a challenging procedure, and there is no clear consensus on which fluoroscopic views are more useful.
Starr et al. and Moushine et al. [2, 4] performed the procedure in supine decubitus with iliac/obturator and inlet/outlet view. A detailed description of fluoroscopic landmarks and a sequence of views is lacking in their studies. Wright Jr. et al. [5] suggested to use obturator oblique, iliac oblique and outlet-obturator views in prone position. The sequential use of different views and their function is elucidated into details. Although the authors outlined the advantages of prone positioning, supine positioning is generally preferable, as it allows easier anesthesiologic management and a combination of percutaneous fixation with anterior open approaches. Recently, a technique using anteroposterior and lateral view to implant antegrade column screw was described, outlining the importance of preoperative planning and lateral assessment of the bony corridor [13].
Navigated and computer-assisted techniques seem to be promising, albeit they need dedicated instrumentation and equipment. Moreover, they are expensive, time consuming and not widely available.
The use of iliac outlet and iliac inlet views offers several advantages. Iliac outlet is a ‘true’ anteroposterior view of the low posterior column and a frontal projection of the ischium triangular section. Therefore, it allows a clear identification of the entry point at the centre of the corridor and detection of its medial and lateral borders. Iliac inlet offers a panoramic view of the posterior column and its relationship with the acetabular cavity. Superimposition of pubis and pubic rami is cleared by the inlet combination. Lateral cross-table view can detect guide pin migration into the sub cotyloid groove or a posterior end point.
Combination of inlet and outlet views to iliac oblique results in clear and intuitive fluoroscopic views.
Two patients had complications. In one case the screw migrated and was substituted. We explained the unscrewing with insufficient purchase in the iliac cortex. One patient showed a new cam deformity of the femoral neck at final follow up. We considered it a consequence of fair reduction of the posterior column fracture line. In none of the cases the complications can be related to the chosen fluoroscopic views. Our study has several limitations: the combination of fluoroscopic views was used on a limited number of patients, with a heterogeneous spectrum of pelvic and acetabular lesions. The procedure appears to be safe and effective. Nonetheless, further studies are needed to determine diagnostic accuracy of iliac-inlet/outlet views.
Data availability
All data regarding the reported cases, including preoperative, intraoperative and follow up imaging are available upon request.
References
Letournel E, Judet R, Elson RA (1993) General Principles of Management of Acetabular Fractures. In: Fract. Acetabulum, 2nd Editio. Springer-Verlag, Berlin, pp 347–361
Starr AJ, Jones AL, Reinert CM, Borer DS (2001) Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury 32 Suppl 1:SA45–50. https://doi.org/10.1016/s0020-1383(01)00060-2
Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12:51–58. https://doi.org/10.1097/00005131-199801000-00009
Mouhsine E, Garofalo R, Borens O et al (2005) Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 36:1330–1336. https://doi.org/10.1016/j.injury.2004.09.016
Wright RDJ, Hamilton DAJ, Moghadamian ES et al (2013) Use of the obturator-outlet oblique view to guide percutaneous retrograde posterior column screw placement. J Orthop Trauma 27:e141–e143. https://doi.org/10.1097/BOT.0b013e318269b88c
Giannoudis PV, Tzioupis CC, Pape H-C, Roberts CS (2007) Percutaneous fixation of the pelvic ring: an update. J Bone Joint Surg Br 89:145–154. https://doi.org/10.1302/0301-620X.89B2.18551
Dienstknecht T, Müller M, Sellei R et al (2013) Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study. Int Orthop 37:673–679. https://doi.org/10.1007/s00264-012-1740-1
Shahulhameed A, Roberts CS, Pomeroy CL et al (2010) Mapping the columns of the acetabulum–implications for percutaneous fixation. Injury 41:339–342. https://doi.org/10.1016/j.injury.2009.08.004
Dienstknecht T, Müller M, Sellei R et al (2014) Percutaneous screw placement in acetabular posterior column surgery: gender differences in implant positioning. Injury 45:715–720. https://doi.org/10.1016/j.injury.2013.10.007
Ochs BG, Stuby FM, Stoeckle U, Gonser CE (2015) Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference. BMC Musculoskelet Disord 16:240. https://doi.org/10.1186/s12891-015-0697-9
Azzam K, Siebler J, Bergmann K et al (2014) Percutaneous retrograde posterior column acetabular fixation: is the sciatic nerve safe? A cadaveric study. J Orthop Trauma 28:37–40. https://doi.org/10.1097/BOT.0b013e318299c8fb
Zhang P, Tang J, Dong Y, et al (2018) A new navigational apparatus for fixation of acetabular posterior column fractures with percutaneous retrograde lagscrew: Design and application. Medicine (Baltimore) 97:e12134. https://doi.org/10.1097/MD.0000000000012134
Krappinger D, Schwendinger P, Lindtner PA (2019) Fluoroscopically guided acetabular posterior column screw fixation via an anterior approach. Oper Orthop Traumatol 31:503–512. https://doi.org/10.1007/s00064-019-00631-0
Funding
Open access funding provided by Università degli Studi di Brescia within the CRUI-CARE Agreement. The authors did not receive support from any organisation for the submitted work. The authors have no relevant financial or non-financial interests to disclose.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors don’t have any conflict of interest.
Ethical approval
This study has been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments. Approval from the ethics committee was not required due to the characteristics of the study and the number of patients. All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by Stefano Cattaneo, Claudio Galante, Elena Biancardi and Marco Domenicucci. The first draft of the manuscript was written by Stefano Cattaneo and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Informed consent
Written consents were obtained from all the patients before the surgical procedure were performed.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Cattaneo, S., Galante, C., Biancardi, E. et al. Use of the iliac-outlet and iliac-inlet combined views in percutaneous posterior column retrograde screw fixation. Arch Orthop Trauma Surg 143, 5713–5717 (2023). https://doi.org/10.1007/s00402-023-04939-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-023-04939-2