Abstract
Introduction
Forced vital capacity (FVC) is often preserved in severe asthma unless there is evidence of either airway remodelling or air trapping. Area under the reactance curve (AX) can be used to assess small airways dysfunction related lung stiffness and is related to disease control in severe asthma.
Methods
We explore if there may be a potential synergistic interaction between FVC and AX in terms of impaired asthma control as ACQ and exacerbations requiring oral corticosteroids (OCS). We pragmatically defined < 100% and ≥ 1.0 kPa/L/s as impaired FVC or AX, respectively.
Results
Patients with combined impairment of FVC and AX had significantly worse asthma control as higher ACQ, more severe exacerbations requiring OCS and worse spirometry (FEV1 and FEF25–75) than those with impaired FVC but preserved AX.
Conclusion
This in turn supports using both spirometry and oscillometry to characterise airway physiology more comprehensively in patients with more severe asthma.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Forced vital capacity (FVC) is often preserved in severe asthma unless there is evidence of either airway remodelling or air trapping [1]. In this regard, as residual volume increases, FVC declines in commensurate fashion. In turn reduced FVC in severe asthma may also reflect reduced lung compliance [2]. Air trapping and airway remodelling are hallmarks of small airways dysfunction (SAD) in severe asthma [3]. The presence of SAD can also be assessed by oscillometry which is an effort independent test for frequency-dependent impedance. In particular, area under the reactance curve (as AX) at 5 Hz and the resonant frequency can be used to assess SAD related lung stiffness and is related to disease control in severe asthma [4].
Here we explore if there may be a potential synergistic interaction between FVC and AX in terms of impaired asthma control as ACQ and exacerbations requiring oral corticosteroids (OCS), whilst also looking at the relationship to type 2 (T2) biomarkers as peripheral blood eosinophils, FeNO and total IgE.
Methods
Data from 181 moderate-to-severe asthma patients with paired spirometry and oscillometry measurements were retrospectively collected from the National Health Service Tayside health informatics database. Spirometry (Micromedical, Chatham, UK) was performed according to ERS/ATS guidelines. Oscillometry was measured using either Masterscreen (Carefusion Hoechberg, Germany) or Tremoflo (Thorasys, Montreal, Canada). Measurements were performed in triplicate to assess oscillometry according to the ERS technical standards with oscillometry always performed prior to spirometry. We chose pragmatic arbritary cut points of < 100% and ≥ 1.0 kPa/L to denote impairment of FVC and AX, respectively. FeNO was measured using NIOX VERO (Circassia, Oxford, UK) according to the manufacturer’s instructions and ATS guidelines. Blood testing was performed for peripheral blood eosinophils and total IgE. Asthma control was determined using the 6-point asthma control questionnaire (ACQ), and the number of OCS-requiring asthma exacerbations in the preceding year was noted.
Statistical analysis was performed using SPSS version 27. Data were assessed for outliers and for normality with Shapiro–Wilks prior to analysis. An overall analysis of variance was performed to evaluate any significant differences in spirometry (mean 95% CI) between the four groups followed by pairwise comparisons with Bonferroni correction and a two tailed alpha error set at 0.05. Significant comparisons for oscillometry, T2 biomarkers, ACQ and OCS exacerbations (median, IQR) were performed using Mann–Whitney U tests. For National Health Service patients, Caldicott approval was obtained whilst for clinical trial patients informed consent and ethical approval was obtained via the East of Scotland research ethics service prior to data collection. In patients receiving biologic therapy, measurements were obtained prior to treatment initiation.
Results
Mean demographic data comprised: gender (F/M), 115/66; age, 51 years; ICS beclomethasone equivalent dose, 1641 µg/day; ex-smokers, 17%; BMI, 31 kg/m2; FEV1, 84%; FVC, 101%; LABA, 83%; LAMA, 46%; LTRA, 52%; THEO, 19%; OAH, 49%; anti-IL5(rα), 18% and anti-IL4rα, 3%.
Patients with combined impairment of FVC and AX had significantly worse asthma control as higher ACQ, more severe exacerbations requiring OCS and worse spirometry (FEV1 and FEF25–75) than those with impaired FVC but preserved AX (Table 1). No significant differences in T2 biomarkers were observed. A similar pattern was detected in patients with preserved FVC and impaired AX versus those with preservation of both FVC and AX except there were no differences in exacerbations (Table 1).
Discussion
We have shown that asthma patients with coupled impairment of FVC and AX have worse clinical outcomes than those with impaired FVC but preserved AX. It is worth noting that the median difference in ACQ score was 0.6-units exceeding the minimally clinically important difference of 0.5. Moreover, it has traditionally been accepted that ACQ is a good predictor of future risk of severe exacerbations thereby placing these findings into relevant clinical context [5].
Patients with preserved FVC and impaired AX had worse spirometry as FEV1 and FEF25–75 than those with preserved FVC and AX. For FEV1, the mean difference amounted to 690 ml which would be considered as being a clinically relevant difference. Hence clinicians might conceivably be lulled into a false sense of security in an individual with preserved FVC by using spirometry alone. From a practical point of view oscillometry is much easier to perform during normal tidal breathing and is more physiological than the artificial expiratory manoeuvre with spirometry. We acknowledge that the ratio of residual volume to total lung capacity is a better method to assess air trapping, albeit unlikely to be performed on a routine basis in a busy real-life clinic.
Our data show the greatest difference in ACQ and exacerbations occurred in those with combined impairment of AX and FVC. This in turn points to using both spirometry and oscillometry to characterise airway physiology more comprehensively in patients with moderate to severe asthma.
Abbreviations
- ACQ:
-
Asthma control questionnaire
- ATS:
-
American Thoracic Society
- AX:
-
Area under reactance curve
- ERS:
-
European Respiratory Society
- FEF:
-
Forced expiratory flow rate between 25 and 75% of forced vital capacity
- FeNO:
-
Fractional exhaled nitric oxide
- FEV1 :
-
Forced expiratory volume in 1 s
- FVC:
-
Forced vital capacity
- ICS:
-
Inhaled corticosteroids
- MCID:
-
Minimal clinically important difference
- OCS:
-
Oral corticosteroids
- R5-R20:
-
Difference in resistance between 5 and 20 Hz
- SAD:
-
Small airways dysfunction
- T2:
-
Type 2
References
Sorkness RL, Bleecker ER, Busse WW et al (2008) Lung function in adults with stable but severe asthma: air trapping and incomplete reversal of obstruction with bronchodilation. J Appl Physiol 104(2):394–403
Hoftman N, Eikermann E, Shin J et al (2017) Utilizing forced vital capacity to predict low lung compliance and select intraoperative tidal volume during thoracic surgery. Anesth Analg 125(6):1922–1930
Scichilone N, Battaglia S, Olivieri D, Bellia V (2009) The role of small airways in monitoring the response to asthma treatment: what is beyond FEV1? Allergy 64(11):1563–1569
Jabbal S, Manoharan A, Lipworth J, Lipworth B (2016) Utility of impulse oscillometry in patients with moderate to severe persistent asthma. J Allergy Clin Immunol 138(2):601–603
Bateman ED, Reddel HK, Eriksson G et al (2010) Overall asthma control: the relationship between current control and future risk. J Allergy Clin Immunol 125(3):600–608
Funding
The authors have not disclosed any funding.
Author information
Authors and Affiliations
Contributions
RC and BJL: both responsible for idea conception, data collection, statistical analysis and drafting all versions of the manuscript.
Corresponding author
Ethics declarations
Conflict of interest
Dr. Lipworth reports non-financial support (equipment) from GSK; equipment, consulting and talks from Thorasys; consulting, advisory board and talks for Circassia; grants, personal fees (consulting, talks and advisory board), other support (attending ATS and ERS) from AstraZeneca, grants, personal fees (consulting, talks, advisory board), other support (attending ERS) from Teva, grants, personal fees (consulting talks and advisory board) and other support from Chiesi, grants, personal fees (consulting, advisory board and talks) from Sanofi, personal fees (consulting, talks and advisory board) from Circassia; in relation to the submitted work; personal fees (consulting) from Lupin, personal fees (consulting and talks) from Glenmark, personal fees (consulting) from Vectura, personal fees (consulting) from Dr Reddy, personal fees (consulting) from Sandoz; grants, personal fees (consulting, talks, advisory board), other support (attending BTS) from Boehringer Ingelheim, grants and personal fees (advisory board and talks) from Mylan outside of the submitted work; and the son of BJL is presently an employee of AstraZeneca. Dr. Chan has no relevant conflicts of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Chan, R., Lipworth, B. Forced Vital Capacity and Low Frequency Reactance Area Measurements Are Associated with Asthma Control and Exacerbations. Lung 200, 301–303 (2022). https://doi.org/10.1007/s00408-022-00542-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00408-022-00542-1