Abstract
Purpose
The aim of this study was to determine the potential of magnetic resonance imaging to evaluate the biodistribution of exogenous iron within 24 h after one single injection of Venofer® (iron sucrose).
Methods
Venofer® was evaluated in vitro for its ability to generate contrast in MR images. Subsequently, iron disposition was assessed in rats with MRI, in vivo up to 3 h and post mortem at 24 h after injection of Venofer®, at doses of 10- and 40 mg/kg body weight (n = 2 × 4), or saline (n = 4).
Results
Within 10–20 min after injection of Venofer®, transverse relaxation rates (R2) clearly increased, representative of a local increase in iron concentration, in liver, spleen and kidney, including the kidney medulla and cortex. In liver and spleen R2 values remained elevated up to 3 h post injection, while the initial R2 increase in the kidney was followed by gradual decrease towards baseline levels. Bone marrow and muscle tissue did not show significant increases in R2 values. Whole-body post mortem MRI showed most prominent iron accumulation in the liver and spleen at 24 h post injection, which corroborated the in vivo results.
Conclusions
MR imaging is a powerful imaging modality for non-invasive assessment of iron distribution in organs. It is recommended to use this whole-body imaging approach complementary to other techniques that allow quantification of iron disposition at a (sub)cellular level.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Iron is an essential nutrient for the transport of oxygen in the body. It is mainly present in heme, which is an important component of the oxygen-transporting protein hemoglobin that is present in erythrocytes. Insufficient intake and/or uptake can result in iron deficiency or anemia. In particular patients suffering from disorders such as chronic kidney disease (CDK) are in need of treatments such as erythropoietin and/or intravenous iron to enhance the number of erythrocytes (1,2,3). Several FDA-approved iron products are presently used in clinical practice, of which particularly iron sucrose has been widely used because this complex has shown to induce less side effects compared to other first generation intravenous iron complexes such as high molecular weight iron dextran (4,5). Although these iron complexes have been shown to be therapeutically beneficial for patients suffering from iron deficiency, there are some concerns that these iron products can also cause short- and long-term complications (6,7). After administration, the iron complexes which are colloidal dispersions of polynuclear ferric-oxyhydroxide cores stabilized by a carbohydrate shell, are taken up by phagocytosis by macrophages of the mononuclear phagocyte system (previously termed reticuloendothelial system (RES)) (8). In this respect, the colloidal iron particles follow the same fate of other nanoparticles based on for example synthetic polymers or lipids (9,10,11,12). In the macrophages, the complexes are degraded and the iron can be stored in ferritin or it can be released to bind to the blood plasma glycoprotein transferrin. The amount of iron released, relies on the physiological iron need and is speculated to also depend in part on the properties of the iron product, specifically related to the type of carbohydrate used to stabilize the iron complex (4,8,13). In case of iron overload, accumulation of iron in macrophages represents a safety concern as this might result in oxidative stress, inflammation, kidney- and heart disorders (6,14). Because of these safety concerns, there is a great need for insight into the distribution of iron after intravenous administration of iron-based medicinal products. In the reflection paper published by the European Medicine Agency concerning data requirements for the development of iron colloidal products for parenteral administration, a minimum requirement for biodistribution studies is outlined. This paper states that studies of iron distribution, retention and accumulation in vivo, should at least comprise analyzing the blood plasma, reticuloendothelial system and organ tissue (15). Furthermore, it is also desirable to examine the early iron distribution, meaning within twenty-four hours after iron administration, preferably in a non-invasive manner. Beshara et al. studied the long-term kinetics and distribution of iron after an intravenous injection, with a particular focus on iron distribution and the production of erythrocytes within 3–4 weeks after administration (16).
There is, however, no comprehensive knowledge available regarding the possible distribution of iron in the different organs within 24 h after administration. Giving insight into the iron distribution shortly after administration of the iron complexes elucidates on the early iron pharmacokinetics, which is useful when for example comparing two iron formulations. Several methods have been described to assess the distribution of iron complexes and quantitative disposition in different organs. Such methods mainly consisted of using radio isotopes, as for example 52Fe or 59Fe in positron emission tomography (PET) studies or using whole body counters (17,18,19). Previous studies using this approach to investigate iron disposition in several organs within a twenty-four-hour span after administration of the iron complexes, demonstrated that these methods allow qualitative assessment of iron biodistribution (16,18,19). Nevertheless, the use of radioactive labeling has its pitfalls such as safety and ethical issues and the need of excessive numbers of animals in the case of pre-clinical in vivo studies (20). Therefore, it is interesting to assess other methods to study the biodistribution of iron complexes. In a recent in vivo study, we investigated the toxicity effects and in vivo disposition of iron after intravenous administration by measuring iron parameters such as hemoglobin, serum iron and liver enzymes in blood serum, but also by performing histochemical studies to determine the tissue iron content and tissue inflammatory markers in rats. However, these parameters measured in the Sprague Dawley rat model did not give sufficient insight into the iron accumulation and adverse iron related effects after intravenous administration of different doses of iron products (manuscript submitted for publication).
Rostoker et al. (21) reported that it is feasible to study iron content in transfusion dependent patients suffering from iron overload or in hemochromatosis patients by using magnetic resonance imaging (MRI). In the past, the MRI technique has been used to investigate the delivery of iron nanoparticles such as liposomal SPION (superparamagnetic iron oxide nanoparticles) formulations (22). Thus, it would be of interest to investigate whether intravenously injected complex – bound iron can also be monitored with in vivo MRI. A study by Vinitski et al. reported that ferric hydroxide sucrose was successfully used as a MR contrast agent to image pulmonary embolism, suggesting the potential use of MRI for imaging of iron sucrose distribution (23). Iron has paramagnetic properties and can therefore reduce the magnetic resonance signal as the iron concentration increases (24).
Therefore, the aim of this study was to determine the potential of magnetic resonance imaging (MRI) to non-invasively and accurately monitor iron disposition within twenty four hours after one single injection of iron sucrose (Venofer®).
Materials and Methods
Materials
Venofer® (lot number: 118101) was obtained from Vifor (International) Ltd., St. Gallen, Switzerland. Saline (sodium chloride 0.9% w/v) was purchased from Fresenius Kabi Nederland B.V. (Zeist, The Netherlands). Heparin, 5000 U.I. (dissolved in water), was a product of Leo Pharma B.V, Amsterdam. Isoflurane was obtained from Teva Pharmachemie B.V., Haarlem, The Netherlands, and sodium pentobarbital 60 mg/ml in water, charge number 12042302, was provided by the pharmacy of Veterinary Medicine at Utrecht University, The Netherlands. Formalin solution neutral buffered 10% (HT501128-4 L), antibiotic antimycotic solution and sodium azide were purchased from Sigma-Aldrich Chemie B.V., Zwijndrecht, The Netherlands. Phosphate buffered saline (PBS) was from J.T. Baker (Avantor Performance materials B.V., Deventer, The Netherlands). Sarstedt S-monovettes tubes containing clotting activator silica beads for serum collection or EDTA for whole blood collection were purchased from Sarstedt B.V, Etten Leur, The Netherlands.
Animals
All experiments were performed according to Institutional Ethical Committee Regulations of Utrecht University, The Netherlands.
MRI
Twelve male HSd: Sprague Dawley rats of 8 weeks old (Harlan laboratories, The Netherlands) were housed in standard perspex cages and were fed standard rat chow (Special Diets Services, United Kingdom) and (acidified) water ad libitum unless stated otherwise. The animals were housed for 4 weeks prior to the experiment and were subjected to a 12 h light/dark cycle. Each treatment group consisted of four animals per group (n = 4), weighing 325–400 g. The rats were randomly assigned to the different treatment groups, which were saline solution (control group) or Venofer® (20 mg (Fe)/ml) given in two different doses, namely: 10 mg (Fe)/kg and 40 mg (Fe)/kg. Each animal received one single intravenous bolus, instead of a drip infusion or slow injection as done in the clinic. The injection consisted of the volume Venofer® needed to reach 10 or 40 mg/kg, replenished with saline (sodium chloride 0.9% w/v) up to 1.5 ml.
Urine Iron Content Measurement
For the iron measurement in urine a total of eight Male HSd: Sprague Dawley rats weighing 325–400 g were used. The animals were divided in two treatment groups (n = 4 per group), specifically: the control group (saline solution) and 40 mg/kg of Venofer®. The experimental set-up for the measurement of iron content in urine is described in more detail further on in materials and methods in the section for iron measurement in urine.
Blood Half-Life
For the blood half-life experiment, eighteen male HSd: Sprague Dawley rats weighing 325–400 g were used. The animals were randomly assigned to different treatment and time-point groups for blood collection as described in more detail in the section; blood half-life of Venofer® in Sprague Dawley rats. Each animal received one single intravenous injection of (40 mg/kg) Venofer® or saline solution. The animals were housed and fed under the same conditions as described above.
Blood Collection
In order to assess that the animals were healthy and non-anemic, 14 days prior to the MRI measurement blood was collected via the tail vein to measure the preteatment blood iron parameters. Rats were deprived from food for 19 h in order to avoid interference of iron present in food and had access to (acidified) water ad libitum before blood collection. The iron related blood parameters measured were: hemoglobin (HB), hematocrite (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), serum Fe (iron) and total iron binding capacity (TIBC) using an ADVIA 120 Siemens hematology analyzer and a Ferrentest (Diagnostic Chemicals Ltd., Charlottetown Canada).
Iron Measurement in Urine after a Single Intravenous Injection
Animals received a single intravenous injection with a volume ranging from 650 to 750 μl conform to the weight of the rat, of Venofer® (40 mg/kg) or ~1.5 ml saline (control). Next, rats were placed in metabolic cages for 24 h, in which they had free access to (acidified) water ad libitum and 5 h to food. The aliment was then removed, resulting in a fasting period of 19 h. The urine of the different animals was collected for 24 h in a measuring cylinder containing 1 ml of antibiotic antimycotic solution diluted 1:5 with deionized water and the volume for each animal was recorded. Next, the urine was kept at −20°C until further assessment of the iron content which was determined using a Ferrentest (Diagnostic Chemicals Ltd., Charlottetown Canada).
In Vitro Assessment of Venofer® as Contrast Agent for MRI
Venofer® was diluted in saline to obtain samples with different iron concentrations, ranging from 0.00125–0.04 M. MRI of the samples was conducted on a 4.7 T horizontal bore MR system (Varian, Palo Alto, CA, USA), using a home-built solenoid coil with a diameter of 3 cm. All measurements were performed at room temperature, using freshly prepared samples. T1 was measured using a Look Locker inversion recovery sequence (Total Repetition Time = 10 s, Repetition time per image = 25 ms, Echo Time (TE) = 4.2 ms, flip angle 5°, 100 images per inversion pulse, 2 averages, slice thickness 1 mm, field of view 30 mm × 30 mm, matrix 256 × 256). T2 values were assessed using a multi-slice multi-spin-echo (MEMS) sequence with the following parameters: Repetition Time (TR) = 3 s, TE = 8.52 ms, 100 echoes, 4 averages, slice thickness 1 mm, field of view 30 mm × 30 mm, matrix 256 × 256. T2* values were obtained using a multi-slice multi-gradient-echo sequence (MGEMS) with the following settings TR = 500 ms, TE = 5 ms, 25 echoes, flip angle 70°, 16 averages, slice thickness 1 mm, field of view 30 mm × 30 mm, matrix 256 × 256. Average T1, T2 and T2* values for each individual sample were established using non-linear fitting routines in Matlab. Next, relaxation rates R1 (1/T1), R2 (1/T2) and R2* (1/T2*) were calculated, and used to determine relaxivities r1, r2 and r2* based on the linear correlation between concentration and relaxation rate.
Blood Half-Life of Venofer® in Sprague Dawley Rats
The blood half-life (t1/2) of Venofer® was obtained by MRI analysis of blood samples taken from the animals at several time points after a single intravenous injection of Venofer® as described above. In short, for each time point 2–3 Sprague Dawley rats received one single injection of Venofer® (40 mg/kg) or saline via the tail vein. Each rat was used to draw blood samples at two subsequent time points. For example, blood was collected from one rat at 30 min and 2 h post injection and the rat was then euthanized by an overdose pentobarbital administered intraperitoneally. Blood was collected in heparin coated Eppendorf tubes at time points 0 (pre-injection), and at 30 min, 1, 2, 3 and 24 h after injection of the formulation. The heparin coated Eppendorf tubes were prepared by pipetting 10 μl of heparin (5000 U.I) into 1.5 ml Eppendorf tubes and then allowing the heparin to concentrate overnight at 37°C. Next, blood was diluted 1:4 with saline and the samples were transferred into 250 μl PCR tubes for magnetic resonance imaging (MRI). Blood samples were stored at 4°C, and MRI was performed within 1–3 days after blood collection. MRI analysis of the blood samples was performed on a 9.4 T horizontal bore MR system (Varian, Palo Alto, CA, USA), using a Millipede™ coil (Varian Inc.). Shortly before the MRI measurements were carried out, the blood samples were vortexed for 30 s. T2-weighted images of blood samples were acquired, using a multi-slice multi-spin-echo sequence (MEMS) with the following parameters: TR = 5 s, TE = 9 ms, 200 echoes, 4 averages, field of view 30 mm × 30 mm, matrix size 256 × 256 and slice thickness 1 mm. Regions of interest were drawn within each tube, and average signal intensities at the different echo times were used to fit the average T2 value in each blood sample, using a non-linear fitting routine in Matlab. Subsequently, average T2 values were used to calculate the average relaxation rate R2 (1/T2) of each blood sample, as R2 scales linearly with contrast agent concentration. Next, blood half-life (t1/2) of Venofer® was obtained from the R2 values using a mono-exponential fitting routine in Matlab, according to the following function:
where R2 (t) is the relaxation rate at each time point, R2 (0) is the relaxation rate at time zero, t is time and t1/2 is the blood half-life (25). R2 values used for fitting were corrected for the average R2 value in blood samples from animals that did not receive any injections, resulting in a baseline R2 value of 0.
Iron Disposition in Sprague Dawley Rats
In Vivo MRI of Iron Distribution after one Single Intravenous Venofer® Injection
Venofer® was intravenously administered via the tail vein to non-anemic Sprague Dawley rats. A total volume of 1.5 ml was administered consisting of a mixture of Venofer®, to obtain a dose of 10 or 40 mg/kg, supplemented with saline. As a control, 1.5 ml saline solution was injected into the rats. Shortly before MRI analysis, the animals were anesthetized with 3% isoflurane in air/O2 (1:2) and endotracheally intubated for mechanical ventilation. During MRI, the animals were mechanically ventilated and anesthetized with 2% isoflurane in air/O2 (4:1). Temperature, respiration, end-tidal CO2 levels, O2 saturation and heart rate were continuously monitored and kept within physiological range. In vivo MRI measurements were conducted on a 4.7 T horizontal bore MR system (Varian, Palo Alto, CA, USA), using a home-built Helmholtz volume coil with a diameter of 8 cm. Serial respiratory-triggered T2-weighted images of the rat abdomen were acquired over a period of 3.25 h using a multi-slice multi-spin-echo sequence (MEMS) with the following parameters: TR = 500 ms, TE = 4.1 ms, 9 echoes, 2 averages, field of view 64 mm × 64 mm, matrix size 128 × 128, 10 slices, 1 mm slice gap and slice thickness 1.5 mm. Total scan time per MEMS acquisition varied between 4.7 and 5.5 min for the different animals depending on the respiration rate. A total of 4 MEMS scans were acquired before intravenous injection of Venofer®, followed by approximately 3 h of repetitive MEMS acquisitions after injection. Following MRI, the animals were allowed to recover from anesthesia, transferred into normal cages and provided with ad libitum standard rat chow and (acidified) water until sacrificed 24 h after injection.
Postmortem MRI of Iron Distribution in Rats Euthanized at 24 h after One Single Intravenous Injection of Venofer®
For analysis of whole-body iron distribution at 24 h after a single intravenous injection of Venofer®, the rats described above in the in vivo MRI section, were prepared for postmortem MRI. Twenty four hours post injection, the rats were sacrificed using an overdose of pentobarbital that was administered intraperitoneally. Next, the animals were perfused with PBS followed by a 4% formaldehyde in water solution until they were completely blood depleted, and subsequently placed for further fixation in 4% formaldehyde for 7 days at 4°C. Subsequently, the formaldehyde solution was replaced by a PBS/0.1% azide solution, and the animals were stored at 4°C for postmortem MRI. Postmortem MRI measurements were conducted on a 4.7 T horizontal bore MR system (Varian, Palo Alto, CA, USA), using a home-built Helmholtz coil with a diameter of 8 cm. In order to cover the whole rat from head-to-toe, the animal was manually shifted by approximately 7 cm in between acquisitions, resulting in three acquisitions per rat. T2*-weighted images were acquired using a multi-gradient-echo 3D sequence (MGE3D) with the following parameters: TR = 100 ms, TE = 5 ms, flip angle = 25°, 8 echoes, 2 averages, field of view 100 mm × 90 mm × 60 mm and matrix size 250 × 226 × 150.
MR Image Analysis In Vivo and Postmortem
For analysis of in vivo MRI data, regions of interest (ROIs) were manually outlined on the first MEMS acquisition of the time series in FSLView (FMRIB Software Library, (26,27). Next, ROI positioning was verified for the entire time series, and ROIs were manually adjusted to correct for motion. ROIs involved the liver, kidney, spleen, spine and muscle. Next, a non-linear fitting routine in Matlab was used to assess the average T2 value in each specific ROI at each individual time point. Venofer® -induced changes in R2 (1/T2) values, representative of Venofer® concentration, were used to evaluate Venofer® distribution. Afterwards, the area under the curve (AUC) for the different treatments in each organ was calculated, starting at baseline R2 at t = 0 until the end of the measurement of every individual rat, using GraphPad Prism version 4.02 for Windows. Subsequently, the average AUC of 4 rats within the different treatment groups was then calculated and statistical analysis was done to evaluate any differences in vivo between the treatments.
For analysis of postmortem MRI data, a predefined subset of organs, including the abdominal organs; liver, spleen, kidney, stomach and intestines and additional organs such as the heart, lungs, spine (bone marrow tissue), muscle, testis and brain, were manually outlined in the MGE3D images using FSLview. Next, a non-linear fitting routine in Matlab was used to assess the average T2* value in each specific organ. T2* values were used to calculate relaxation rates R2*, as described in the in vitro assessment of Venofer® section. In addition, the average signal intensity in the first T2*-weighted image (TE = 5 ms) of the MGE3D acquisition was calculated in the liver and spleen, and normalized to the average signal intensity in muscle tissue in the corresponding T2*-weighted image.
Statistical Methods
The in vivo and postmortem data are expressed as mean ± standard deviation (st.dev). A two-way ANOVA with Bonferroni post-hoc testing was used to test the effects of the different Venofer® treatments on the Area Under the Curve from in vivo R2 values, postmortem R2* values and postmortem normalized signal intensity. Statistics was performed in GraphPad Prism version 4.02 for Windows, GraphPad Software, San Diego California USA. P < 0.05 was considered statistically significant.
Results and Discussion
Pretreatment Blood Collection
To assure that the rats were healthy and not anemic prior the MRI experiment, blood was collected via the tail vein 2 weeks prior to the start date of the experiment and several blood iron related parameters were measured (Table I).
The parameter values shown in Table I were within normal physiological range of non- iron deficient rats as described in the manual for animal experiments, and as indicated by the animal supplier (28). The serum iron and total iron binding capacity values were in accordance with previously obtained results within our department (manuscript submitted for publication).
Iron Measurement in Urine 24 h after a Single Intravenous Injection
Urine samples were collected in measuring cylinders for 24 h after one single Venofer® intravenous injection, as described in the section materials and methods for iron measurement in urine. A brownish color was observed in the urine collected at 3 h after administration in all rats receiving Venofer®, which was not observed in animals that received saline solution or in urine collected at 24 h post Venofer® injection (Fig. 1). This suggests that the exogenous iron is partly excreted via the urine within 24 h after administration.
In order to verify whether the brown color was indeed caused by iron, its concentration was measured in urine collected for twenty-four hours from animals receiving 40 mg/kg Venofer® or saline.
Figure 2 shows the total iron recovered in urine for the individual rats. The animals excreted an average of 20 ml urine in 24 h (range was 10–40 ml). For the rats that received saline solution, no iron was detected in the urine. This in contrast to the animals receiving 40 mg/kg Venofer®, which showed an average iron concentration of 380 ± 215 μmol/L. Urine-collected iron accounted for 1.1 ± 0.2% of the administered iron dose. This indicates that to some extent there is renal elimination of iron originating from the Venofer® injection. Danielson et al. also reported renal excretion in humans after receiving one intravenous Venofer® injection containing 100 mg Fe, 5% iron and 68% sucrose of the injected dose were excreted respectively after 4 h (29). A brown coloration of urine indicative of iron renal elimination, has also been reported for animals that received low molecular iron preparations (< MW 18 kD) (30). Venofer® has a molecular weight in the range of 34–60 kD and further research demonstrated that the average particle core size is smaller than 10 nm (31,32,33). Renal filtration is thought to be limited to 30–50 kD (around 5 nm) for proteins (34,35,36) making it plausible, that to some extent smaller iron complexes are filtered by the kidneys.
In Vitro MRI Assessment of Venofer®
Venofer® was evaluated as a contrast agent for MRI prior to the in vivo experiment. Both the longitudinal (T1) and transverse (T2 or T2*) relaxation times for several Venofer® (iron) concentrations were measured to determine the relaxation rates (R1 = 1/T1 (s−1); R2 = 1/T2 (s−1) and R2* = 1/T2* (s−1)) as described in the materials and methods section for in vitro assessment of Venofer®. The slope obtained from linear regression analysis with iron concentration as the independent variable (x) and relaxation rate (R) as the dependent variable (y), provided the corresponding relaxivities r1, r2 and r2*, which give an indication of the efficiency of Venofer® to generate contrast on T1-weighted, T2-weighted or T2*-weighted magnetic resonance images, respectively.
The r1, r2 and r2* relaxivities of Venofer® in saline solution at room temperature and 4.7 T magnetic field strength were respectively 0.45 mM−1s−1, 3.24 mM−1s−1 and 3.63 mM−1s−1 (Table II). These values indicate that Venofer® generates more efficient contrast on T2(*)-weighted magnetic resonance (MR) images than T1-weighted images. When compared to the relaxivities of a commonly clinically used T1 contrast agent at 4.7 T, such as Gadovist (Gd-DO3A-butrol), it can be concluded that Venofer® is less efficient as a contrast agent (relaxivities Gd-DO3A-butrol, r1 = 3.43 mM−1 s−1; r2 = 4.69 mM−1 s−1 (unpublished results). However, the iron complex does generate sufficient MRI contrast as it clearly generates a decrease in signal intensity on T2-weighted images, i.e. darker images, with increasing concentrations and increasing echo time (TE) as shown in Fig. 3a. This decrease in signal intensity is caused by the fact that iron shortens the intrinsic T2 relaxation time according to its paramagnetic properties (24,37). Quantitative T2- and T2*-maps are shown in Fig. 3b to visualize the effect of increasing iron concentrations on T2 and T2* relaxation times. Furthermore, R2- and R2*-maps (1/T2 and 1/T2*) are shown in Fig. 3c to visualize the effect of increasing iron concentrations on R2 and R2* relaxation rates. These maps clearly demonstrate that the highest concentration of Venofer® (0.04 M) most strongly reduced T2 and T2* values, whereas the lowest concentration (0.00125 M) had a smaller effect on T2 and T2* values. Moreover, these maps show that Venofer® affects T2 and T2* relaxation times in a similar fashion, which was expected as relaxivities r2 and r2* are comparable (Table II). Consequently, both T2- and T2*-weighted MR imaging sequences qualified for non-invasive monitoring of Venofer® biodistribution. In vivo experiments were performed using T2-weighted imaging (MEMS), whereas T2*-weighted imaging (MGE3D) was used for postmortem MRI.
Blood Half-Life of Venofer® and In Vivo MRI of Iron Distribution
Blood Half-Life of Venofer®
The blood half-life (t1/2) of Venofer® was determined as described in the section materials and methods for blood half-life of Venofer® in Sprague Dawley rats. Here, T2 relaxation times of blood samples collected at 0, 30 min, 1, 2, 3 or 24 h after one single injection of 40 mg/kg Venofer® were measured at 9.4 T. The calculated blood half-life (t1/2) of Venofer®, based on a mono-exponential fit of the R2 (i.e. 1/ T1/2) values as a function of time, was 2.3 ± 0.6 h. In humans, a terminal blood half-life of t1/2 of 5.3 h was reported, based on the decay in iron concentration in the terminal phase (3–12 h post injection) (29). Longer elimination half-life, in humans compared to rodents, has also been reported for other types of nano-based medicines such as pegylated liposomal doxorubicin formulations (38).
In Vivo MRI of Iron Distribution
Axial multi-slice T2-weighted multi-spin-echo images were acquired to monitor iron distribution over different abdominal organs following Venofer® injection. Examples of resulting axial R2 (1/T2) maps of the abdominal region of animals pre- and post- one single injection of saline solution (control), 10 mg/kg or 40 mg/kg Venofer® are shown in Fig. 4. Changes observed in R2 values compared to pre-injection R2 values are proportional to the concentration of iron present in the organs, meaning that an increase of the relaxation rate R2 reflects more iron (see Fig. 3).
For further quantitative assessment of the in vivo distribution of Venofer®, average R2 values were calculated in several regions of interest (ROIs), i.e. liver, spleen, kidney, spine (bone marrow) and muscle (Fig. 5).
In the liver (Fig. 5a), an injection of the frequently used dose for preclinical toxicity studies of 40 mg/kg, induced a rapid increase in R2 values that slowly continued to elevate reaching a plateau with an average R2 of 95 s−1 around 50 min post injection (57 s−1 higher compared to saline-treated control). Administration of 10 mg/kg of Venofer®, which is close to the maximum clinical dose of 7 mg/kg (39), also resulted in a fast increase of R2 values followed by a slow increase in R2 to reach maximum values of ~ 63 s−1 around 100 min after administration.
Similar to the liver, the spleen (Fig. 5b) demonstrated a steady increase in R2 values reaching maximum values at 30 min post injection that remained stable (low dose Venofer®) or showed a modest decrease (high dose Venofer®) towards the end of the in vivo measurements. Animals that received 40 mg/kg Venofer® showed an increase reaching maximum R2 values of 82 s−1 (54 s−1 higher than saline-treated control), while animals treated with 10 mg/kg Venofer® reached maximum R2 values of 43 s−1 (14 s−1 higher than saline-treated control).
The kidney also showed a rapid increment in R2 after administration of 40 mg/kg Venofer®. However, unlike the liver and spleen, the initial increase in R2 was followed by a more obvious gradual decrease over time (Fig. 5c). Three hours post-injection, R2 values of the whole kidney, as well as for the separate compartments (Fig. 5d, e; cortex and medulla), decreased to values not different from the pretreatment or saline values both at high and low dose Venofer®. In addition, there was no distinction between the two sections of the kidney (cortex and medulla) during the in vivo measurements at either dose. Compared to all other regions of interest, spine, which served as a measure for bone marrow, and muscle tissues showed only modest changes in R2 after injection with the iron complex (Fig. 5f, g). Figure 5h depicts the area under the curve (AUC) for the R2 values over time in each organ. The AUC in the liver, spleen and kidney (including both the compartments cortex and medulla) of animals that received 40 mg/kg Venofer®, was significantly increased compared to animals in the 10 mg/kg and saline (control) treated groups (p < 0.001). Furthermore, also the 10 mg/kg Venofer® dose, which is comparable to the maximum clinical dose, significantly increased the AUC compared to saline-treated control animals in liver, spleen (p < 0.001) and kidney (p < 0.05).
This clearly demonstrates the potential of MRI to measure the in vivo distribution of the iron sucrose complex at relatively high dose.
Absolute concentrations of deposited iron in the organs of interest cannot be quantified because the r2 relaxivity of Venofer®, as assessed in vitro, may change in vivo. For instance due to release of iron from the sucrose complex or due to internalization of the iron complex by cells of the RES (8). Moreover, changes in R2 values do not only originate from deposited iron, but may partly originate from Venofer® that is circulating in the blood, particularly in highly vascularized tissues such as spleen and liver. The blood half-life of Venofer® in rats is 2.3 ± 0.6 h, meaning that the contribution of vascular Venofer® to the measured R2 values should gradually decrease over the time course of the longitudinal in vivo MRI experiment, and only around 40% of the injected dose will be present in the blood at the final acquisition 3 h post-injection. Nevertheless, R2 values remained constantly elevated over the time course of 3 h in the liver and spleen, indicating that these organs are the main organs of exogenous iron disposition after a single injection of the iron complex.
Post Mortem MRI of Iron Distribution in Rats Euthanized 24 h after One Single Injection of Venofer®
Postmortem T2*-based MRI (multi-gradient-echo 3D (MGE3D)) was performed to evaluate whole-body iron disposition, 24 h post Venofer® injection. Three postmortem imaging sessions were performed for each rat to allow whole-body coverage with an 8 cm diameter Helmholtz volume coil (Fig. 6), and ROIs were manually drawn in different organs of interest to calculate mean R2* values from the MGE3D images (Fig. 7).
ROI-based analysis in rats that received Venofer® showed increased R2* values compared to saline-treated control animals, indicative of iron uptake in the liver (Fig. 7). R2* values from organs such as the lungs and the heart, which are also considered target organs for iron accumulation, are not depicted in Fig. 7 as these values may be affected by the presence of air and should therefore be treated with care.
The observed R2* values in the liver and spleen suggest that there is no significant difference in iron accumulation between animals treated with 10 or 40 mg/kg (Fig. 7). However, this outcome is not in accordance with Fig. 6, where a clear decrease in signal intensity was observed in these organs with increasing dose from 10 to 40 mg/kg. This discrepancy may be explained by substantial iron accumulation in these organs, resulting in T2* values that were too low for accurate T2* quantification. Therefore iron accumulation in the liver and spleen was also studied by quantification of the average signal intensity in these organs in the T2*-weighted images (TE = 5 ms), after normalization to the average signal intensity of muscle tissue in the corresponding images (Fig. 8). Both in liver and spleen, the normalized signal intensity was significantly lower in the animals that received the 40 mg/kg dose as compared to the saline-treated controls (Fig. 8). Moreover, both organs demonstrated a significant decrease in signal intensity with increasing Venofer® dose.
The outcomes of this MRI experiment demonstrate that within 24 h of one single administration of two different doses of Venofer®, the liver and spleen are the main organs for exogenous iron disposition. This coincides with previous reports describing the most adopted mechanism, in which intravenously injected iron complexes are taken up by the mono nuclear phagocyte system and engulfed by macrophages to next dissociate the iron from the complex. Subsequently, the iron is then presumably mainly absorbed by the liver, spleen and bone marrow. (8,13).
Besides chemical and physical characterization of the iron nano-colloidal complexes, a biodistribution study is necessary in order to perform a proper comparison between different iron products. PET imaging with radioisotope-labeled iron and inductively coupled plasma mass spectrometry (ICP-MS) techniques have been demonstrated to allow assessment of iron content in different organs (3,16). Nevertheless, an MRI-based method that allows longitudinal non-invasive monitoring of iron distribution is considered more advantageous, as this imaging modality does not require modifications of the iron complex with radioactive labels, as needed for PET. Moreover, there is no need to sacrifice animals at several time points such as in the case of ICP-MS measurements, and it is hence expected to be easily translated to the clinic.
The present study shows that T2-based MRI allows continuous and non-invasive monitoring of iron distribution over various organs of interest. Despite the obvious advantages, there are some limitations to the present method. First, iron complexes such as Venofer® induce relatively low MRI contrast, which limits its detection to relatively high iron concentrations. It should also be taken into account that due to differences between the various iron complexes, each iron product should be separately evaluated for their ability to generate sufficient MR contrast. Second, the spatial resolution of MRI only allows monitoring iron disposition at macroscopic level but cannot be used when interested in cellular iron disposition which can be studied with microscopy techniques (40). Third, R2* changes in organs cannot be directly converted into iron concentrations, as intracellular iron accumulation may alter its relaxivities (24,41).
Therefore, in order to scrutinize differences in biodistribution and fate of the various iron preparations as proposed by the European Medicines Agency (EMA) (15), a multimodal study should be carried out. Several evaluation techniques have to be combined to encompass the full scope of iron accumulation in plasma, mononuclear phagocyte system and organ tissues, after administration of iron-based medicines.
Conclusion
MRI was successfully used for non-invasive monitoring of iron distribution up to twenty-four hours after one single intravenous injection of Venofer® in rats. The present method is considered complementary to existing iron quantification techniques, and could therefore be a valuable whole-body imaging approach for biodistribution measurements to compare iron-based medicines in preclinical studies.
Abbreviations
- EMA:
-
European medicine agency
- HB:
-
Hemoglobin
- Hct:
-
Hematocrite
- ICP-MS:
-
Plasma mass spectrometry
- MCH:
-
Mean corpuscular hemoglobin
- MCHC:
-
Mean corpuscular hemoglobin concentration
- MCV:
-
Mean corpuscular volume
- MEMS:
-
Multi-slice multi-spin-echo sequence
- MGE3D:
-
Multi-gradient-echo 3D
- MGEMS:
-
Multi-slice multi-gradient-echo sequence
- MRI:
-
Magnetic resonance imaging
- PET:
-
Positron emisssion tomography
- r1, r2, r2*:
-
Relaxivities
- R2 :
-
Transverse relaxation rate
- ROIs:
-
Region of interest
- Serum Fe:
-
Serum iron
- SPIONs:
-
Superparamagnetic iron oxide nanoparticles
- T1 :
-
Longitudinal relaxation time
- t1/2 :
-
Blood half-life
- T2 :
-
Transverse relaxation time
- TE:
-
Echo time
- TIBC:
-
Total iron binding capacity
- TR:
-
Repetition time
References
Macdougall IC, Geisser P. Use of intravenous iron supplementation in chronic kidney disease: an update. Iran J Kidney Dis. 2013;7(1):9–22.
Schiesser D, Binet I, Tsinalis D, Dickenmann M, Keusch G, Schmidli M, et al. Weekly low-dose treatment with intravenous iron sucrose maintains iron status and decreases epoetin requirement in iron-replete haemodialysis patients. Nephrol Dial Transplant. 2006;21(10):2841–5.
Elford P, Bouchard J, Jaillet L, Pearson N, Rogue A, Sabadie C, et al. Biodistribution and predictive hepatic gene expression of intravenous iron sucrose. J Pharmacol Toxicol Methods. 2013;68(3):374–83.
Chertow GM, Mason PD, Vaage-Nilsen O, Ahlmén J. Update on adverse drug events associated with parenteral iron. Nephrol Dial Transplant. 2006;21(2):378–82.
Fishbane S. Safety in iron management. Am J Kidney Dis. 2003;41:18–26.
Agarwal R, Vasavada N, Sachs NG, Chase S. Oxidative stress and renal injury with intravenous iron in patients with chronic kidney disease. Kidney Int. 2004;65(6):2279–89.
Faich G, Strobos J. Sodium ferric gluconate complex in sucrose: safer intravenous iron therapy than iron dextrans. Am J Kidney Dis. 1999;33(3):464–70.
Danielson BG. Structure, chemistry, and pharmacokinetics of intravenous iron agents. J Am Soc Nephrol. 2004;15(suppl 2):S93–S8.
Storm G, Belliot SO, Daemen T, Lasic DD. Surface modification of nanoparticles to oppose uptake by the mononuclear phagocyte system. Adv Drug Deliv Rev. 1995;17:31–48.
Romberg B, Oussoren C, Snel CJ, Hennink WE, Storm G. Effect of liposome characteristics and dose on the pharmacokinetics of liposomes coated with ppoly(amino acid). Pharm Res. 2007;24:2394–401.
Duan X, Duan Y. Physicochemical characteristics of nanoparticles affect circulation, biodistribution, cellular internalization and trafficking. Small. 2013;9:1521–32.
Gustafson HH, Holt-Casper D, Grainger DW, Ghandehari H. Nanoparticle uptake: the phagocyte problem. Nano Today. 2015;10(4):487–510.
Koskenkorva-Frank TS, Weiss G, Koppenol WH, Burckhardt S. The complex interplay of iron metabolism, reactive oxygen species, and reactive nitrogen species: insights into the potential of various iron therapies to induce oxidative and nitrosative stress. Free Radic Biol Med. 2013;65:1174–94.
Bishu K, Agarwal R. Acute injury with intravenous iron and crltsconcerns regarding long-term safety. Clin J Am Soc Nephrol. 2006 September 1. 2006;1(Suppl 1):S19–23.
EMA. Reflection paper on the data requirements for intravenous iron-based nano-colloidal products developed with reference to an innovator medicinal product. 2015; EMA/CHMP/SWP/620008/2012. http://www.ema.europa.eu/docs/en_GB/document_library/Scientific_guideline/2015/03/WC500184922.pdf.
Beshara S, Lundqvist H, Sundin J, Lubberink M, Tolmachev V, Valind S, et al. Kinetic analysis of 52Fe-labelled iron(III) hydroxide–sucrose complex following bolus administration using positron emission tomography. Br J Haematol. 1999;104(2):288–95.
Schümann K, Szegner B, Kohler B, Pfaffl MW, Ettle T. A method to assess 59Fe in residual tissue blood content in mice and its use to correct 59Fe-distribution kinetics accordingly. Toxicology. 2007;241(1–2):19–32.
Beshara S, Lundqvist H, Sundin J, Lubberink M, Tolmachev V, Valind S, et al. Pharmacokinetics and red cell utilization of iron(III) hydroxide–sucrose complex in anaemic patients: a study using positron emission tomography. Br J Haematol. 1999;104(2):296–302.
Beshara S, Sörensen J, Lubberink M, Tolmachev V, Långström B, Antoni G, et al. Pharmacokinetics and red cell utilization of 52Fe/59Fe-labelled iron polymaltose in anaemic patients using positron emission tomography. Br J Haematol. 2003;120(5):853–9.
Walczyk T, Davidsson L, Zavaleta N, Hurrell RF. Stable isotope labels as a tool to determine the iron absorption by Peruvian school children from a breakfast meal. Fresen J Anal Chem. 1997;359(4):445–9.
Rostoker G, Cohen Y. Magnetic resonance imaging repercussions of intravenous iron products used for iron-deficiency anemia and dialysis-associated anemia. J Comput Assist Tomogr. 2014;38(6):843–4.
Kato Y, Zhu W, Backer MV, Neoh CC, Hapuarachchige S, Sarkar SK, et al. Noninvasive imaging of liposomal delivery of superparamagnetic iron oxide nanoparticles to orthotopic human breast tumor in mice. Pharm Res. 2015;32:3746–55.
Vinitski S, Thakur ML, Consigny PM, Mitchell DG, Mohamed FB, Ortega HV. Use of ferrum in MRI of lung parenchyma and pulmonary embolism. Magn Reson Imaging. 1993;11(4):499–508.
Gandon Y, Olivie D, Guyader D, Aube C, Oberti F, Sebille V, et al. Non-invasive assessment of hepatic iron stores by MRI. Lancet (London, England). 2004;363(9406):357–62.
Liu L, Hitchens TK, Ye Q, Wu Y, Barbe B, Prior DE, et al. Decreased reticuloendothelial system clearance and increased blood half-life and immune cell labeling for nano- and micron-sized superparamagnetic iron-oxide particles upon pre-treatment with Intralipid. Biochim Biophys Acta. 2013;1830(6):3447–53.
Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens TE, Johansen-Berg H, et al. Advances in functional and structural MR image analysis and implementation as FSL. NeuroImage. 2004;23(Suppl 1):S208–19.
Jenkinson M, Beckmann CF, Behrens TE, Woolrich MW, Smith SM. FSL. NeuroImage. 2012;62(2):782–90.
van Zutphen LFM, Baumans V, Ohl F. Handboek proefdierkunde: proefdieren, dierproeven, alternatieven en ethiek (5e dr., 2e opl. ed.). Amsterdam: Reed Business; 2012.
Danielson BG, Salmonson T, Derendorf H, Geisser P. Pharmacokinetics of iron(III)-hydroxide sucrose complex after a single intravenous dose in healthy volunteers. Arzneimittelforschung. 1996;46(6):615–21.
Geisser P, Baer M, Schaub E. Structure/histotoxicity relationship of parenteral iron preparations. Arzneimittelforschung. 1992;42(12):1439–52.
Venofer® (iron sucrose injection, USP) NDA 21–135/S-017 https://www.accessdata.fda.gov/drugsatfda_docs/label/2007/021135s017lbl.pdf.
Fütterer S, Andrusenko I, Kolb U, Hofmeister W, Langguth P. Structural characterization of iron oxide/hydroxide nanoparticles in nine different parenteral drugs for the treatment of iron deficiency anaemia by electron diffraction (ED) and X-ray powder diffraction (XRPD). J Pharm Biomed Anal 201386:151–160.
Kudasheva DS, Lai J, Ulman A, Cowman MK. Structure of carbohydrate-bound polynuclear iron oxyhydroxide nanoparticles in parenteral formulations. J Inorg Biochem. 2004;98(11):1757–69.
Liu J, Yu M, Zhou C, Zheng J. Renal clearable inorganic nanoparticles: a new frontier of bionanotechnology. Mater Today. 2013;16(12):477–86.
Ruggiero A, Villa CH, Bander E, Rey DA, Bergkvist M, Batt CA, et al. Paradoxical glomerular filtration of carbon nanotubes. Proc Natl Acad Sci U S A. 2010;107(27):12369–74.
Choi HS, Liu W, Misra P, Tanaka E, Zimmer JP, Ipe BI, et al. Renal clearance of nanoparticles. Nat Biotechnol. 2007;25(10):1165–70.
Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD, et al. MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood. 2005;106(4):1460–5.
Gabizon A, Shmeeda H, Barenholz Y. Pharmacokinetics of Pegylated liposomal doxorubicin. Clin Pharmacokinet. 2003;42(5):419–36.
Schröder O, Mickisch O, Seidler U, De Weerth A, Dignass AU, Herfarth H, et al. Intravenous iron sucrose versus oral iron supplementation for the treatment of iron deficiency anemia in patients with inflammatory bowel disease a randomized, controlled, open-label, multicenter study. Am J Gastroenterol. 2005;100(11):2503–9.
Richter GW. The cellular transformation of injected colloidal iron complexes into ferritin and hemosiderin in experimental animals: a study with the aid of electron microscopy. J Exp Med. 1959;109(2):197–216.
Tanimoto A, Oshio K, Suematsu M, Pouliquen D, Stark DD. Relaxation effects of clustered particles. J Magn Reson Imaging. 2001;14(1):72–7.
Acknowledgments and Disclosures
This research was financially supported by Vifor (International) Ltd., St. Gallen, Switzerland.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Span, K., Pieters, E.H.E., Hennink, W.E. et al. The Use of Magnetic Resonance Imaging for Non-Invasive Assessment of Venofer® Biodistribution in Rats. Pharm Res 35, 88 (2018). https://doi.org/10.1007/s11095-018-2348-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s11095-018-2348-y