Abstract
Creation of a hemodialysis arteriovenous fistula (AVF) causes aberrant vascular mechanics at and near the AVF anastomosis. When inadequately regulated, these aberrant mechanical factors may impede AVF lumen expansion to cause AVF maturation failure, a significant clinical problem with no effective treatments. The endothelial nitric oxide synthase (NOS3) system is crucial for vascular health and function, but its effect on AVF maturation has not been fully characterized. We hypothesize that NOS3 promotes AVF maturation by regulating local vascular mechanics following AVF creation. Here we report the first MRI-based fluid-structure interaction (FSI) study in a murine AVF model using three mouse strains: NOS3 overexpression (NOS3 OE) and knockout (NOS3−/−) on C57BL/6 background, with C57BL/6 as the wild-type control (NOS3+/+). When compared to NOS3+/+ and NOS3−/−, AVFs in the OE mice had larger lumen area. AVFs in the OE mice also had smoother blood flow streamlines, as well as lower blood shear stress at the wall, blood vorticity, inner wall circumferential stretch, and radial wall thinning at the anastomosis. Our results demonstrate that overexpression of NOS3 resulted in distinct hemodynamic and wall mechanical profiles associated with favorable AVF remodeling. Enhancing NOS3 expression may be a potential therapeutic approach for promoting AVF maturation.
Similar content being viewed by others
Introduction
The arteriovenous fistula (AVF), created by a direct anastomosis between a peripheral artery and vein, is the preferred choice of vascular access for hemodialysis patients. However, AVF maturation failure remains a critically important clinical problem and currently there are no effective treatments to promote AVF maturation1,2,3. AVF maturation failure results in dialysis therapy with other types of vascular access including a tunneled dialysis catheter or a synthetic arteriovenous graft (AVG). Mortality rates in patients dialyzing with catheters have been reported to be 1.4 and 1.1 times greater than that in patients dialyzing with AVFs and AVGs, respectively4. If successfully matured for dialysis, an AVF is favored over an AVG due to its higher long-term patency and lower long-term intervention rates5. Further, compared to patients dialyzing with a mature AVF, the relative mortality risk has been reported as 1.4 fold higher for patients using an AVG6.
Currently up to 60% of newly created AVFs do not successfully mature to become usable for hemodialysis7,8,9,10. The two main etiologies of AVF maturation failure are aggressive neointimal hyperplasia (NH) development and inadequate lumen expansion of the AVF vein11,12. NH, which usually occurs at and near the AVF anastomosis, is primarily a result of vascular smooth muscle cells (SMCs) and fibroblasts migrating and proliferating from the vessel media into the intima11,13. Lumen expansion involves the relaxation of vascular SMCs upon stimulation by vasodilators released from endothelial cells (ECs)14,15,16,17. The shunting of arterial flow into the vein decreases the resistance and thus causes the regional AVF flow to be 5- to 10-fold higher than normal arterial flow in patients18,19. Such a drastic increase in volumetric blood flow, coupled with the acute change in blood flow direction at the anastomosis, causes drastically aberrant vascular mechanics (i.e., hemodynamics and wall mechanics) in the anastomotic region. Based on the wealth of literature regarding the effects of hemodynamics and wall mechanics on arterial wall function and remodeling, it has long been postulated that aberrant vascular mechanics may lead to NH formation and/or inadequate lumen dilation, and ultimately AVF maturation failure. However, whether these relationships exist in the vein are not yet clear, as venous ECs and SMCs are known to have different phenotypes from their arterial counterparts20,21,22. Importantly, detailed hemodynamics and wall mechanics in the AVF are not yet fully available.
Nitric oxide (NO) has been well-established as beneficial to vascular health and function23,24. NO derived from endothelial nitric oxide synthase (eNOS, also known as NOS3) stimulates arterial17 and venous16,17 vasorelaxation via increasing the generation of cyclic guanosine monophosphate (cGMP) to cause active smooth muscle relaxation, and inhibits arterial SMC migration and proliferation25,26, all of which could lead to favorable AVF development. However, the effect of NOS3 on AVF remodeling has not been fully characterized. In addition, whether its effect is mediated by vascular mechanics of the AVF remains unknown. The present study aims to address these questions by investigating AVF remodeling and characterizing vascular mechanics in three mouse strains with different NOS3 expression levels. To do so, we have made significant contributions to the development of image-based biomechanical modeling tools for understanding the complex hemodynamics in AVFs. We first developed an MRI-based computational fluid dynamics (CFD) method that can be used on AVFs in hemodialysis patients27. Next, we refined the MRI-based CFD to characterize the hemodynamics of murine AVFs at very high temporal and spatial resolutions28. These two previous studies assumed the blood vessel wall to be rigid. Here we present the first MRI-based fluid-structure interaction (FSI) pipeline to characterize both hemodynamics and wall mechanics in murine AVFs with varying NOS3 expression levels in deformable blood vessel walls.
Results
A photograph of a representative mouse AVF is shown in Supplementary Fig. S1. Our experience is that NH in the wild-type control was significant at Week 3. Therefore, we investigated AVF lumen and NH (Fig. 1) at 21 days after AVF creation in mice with varying NOS3 expression levels, as well as their hemodynamics (Figs 2–5) and wall mechanics (Figs 6–8).
Mouse AVF lumen geometry by MRI and NH by histology
Two-dimensional (2D) time-of-flight (ToF) MRI was used to visualize the global lumen geometry of the AVF. This is a common non-contrast-agent bright-blood method for imaging the vasculature, where the flowing blood (hence lumen) appears white. Figure 1a–c shows maximum intensity projection (MIP) images from the 2D ToF MRI for all three mouse strains; the NOS3 OE mouse had larger overall AVF lumen than NOS3+/+ and NOS3−/− mice. A different type of MRI scan with higher spatial resolution was then performed to reveal the AVF lumen, particularly the anastomosis, more clearly to create lumen geometrical models for simulations. Figure 1d–f shows the black-blood (BB) MRI image of lumen at the AVF anastomosis. BB MRI registers a lack of signal (black) when blood is flowing through the slice of interest, thus black indicates the vessel lumen. White signals in BB MRI images indicate static tissue. As shown in Fig. 1d, the NOS3 OE mouse had a clearly defined and open anastomosis connecting the artery and the expanded proximal AVF vein. In both of the NOS+/+ and NOS3−/− mice (Fig. 1e,f), the anastomosis appeared to be narrow; the proximal AVF vein was not as large as in the NOS3 OE mouse, suggesting more pronounced NH formation and/or impaired lumen expansion in the NOS3+/+ and NOS3−/− mice. Indeed, NH in the NOS3 OE mouse was small, and the NOS3+/+ and NOS3−/− mice had extensive NH, as seen in the Russell-Movat pentachrome-stained histological images of the proximal AVF vein cross-sections (Fig. 1g–i).
The BB images were used for 3D reconstructions of the AVF lumen, which were then used to build lumen geometrical models for the FSI simulations. Figure 1j–l shows the 3D reconstructions of the AVF lumen from NOS3 OE, NOS3+/+ and NOS3−/− mice. We calculated the lumen cross-sectional area in the proximal AVF vein using these 3D reconstructions. The AVF lumen cross-sectional area, which was averaged over 7 mm starting from the anastomosis, was significantly larger in the NOS3 OE mouse (7.1 ± 1.5 × 106 µm2) as compared to the NOS3+/+ mouse (5.0 ± 1.2 × 106 µm2, p < 0.01) and the NOS3−/− mouse (2.2 ± 1.1 × 106 µm2, p < 0.01); however, the AVF lumen of all mice was bigger than the lumen of the baseline, wild-type presurgical jugular vein (0.6 ± 0.2 × 106 µm2, p < 0.01).
Taken together, our MRI images, histological images and 3D reconstructions show that the NOS3 OE mouse had the most favorable AVF remodeling, with the biggest lumen expansion and smallest NH. We next performed FSI simulations to characterize the hemodynamics and wall mechanics of the AVFs.
Mouse AVF hemodynamics by FSI
Figure 2a–c show the velocity, Reynolds number (a unitless measure of blood flow turbulence), and the wall hemodynamic parameter τw (which is the fluid shear stress at the wall, i.e., the frictional forces between the flowing blood and the vessel wall). Figure 2d–f show volumetric hemodynamic parameters (i.e., vorticity, relative helicity and Q-criterion) that can be used to identify a vortex. Vorticity is a measurement of the magnitude of blood rotation with no directional component. Relative helicity is a normalized measurement of the direction of blood rotation ranging from +1 (completely clockwise) to −1 (completely counterclockwise). Q-criterion is a measurement of the dominance of parallel blood flow (e.g., in the direction of bulk flow) or rotational blood flow; a positive Q-criterion value indicates dominant rotational blood flow and a possible vortex, whereas a negative Q-criterion value indicates dominant parallel flow with little rotation and no vortex. These six hemodynamic parameters were averaged over both a cardiac cycle and the first 7 mm of the AVF vein starting from the anastomosis (140 cross-sectional slices, with 50 μm between 2 slices) in NOS3 OE, NOS3+/+ and NOS3−/− mice at 21 days after AVF creation. The NOS3 OE mouse had lower blood flow velocity (Fig. 2a) than the NOS3+/+ (p < 0.001) and NOS3−/− (p < 0.001) mice. Although the Reynolds number (Fig. 2b) was well below the threshold for turbulent flow (which is 400–55029) in all strains, it was smaller in the NOS3 OE mice than in the NOS3+/+ (p < 0.001) and NOS3−/− (p < 0.001) mice. Indeed, the blood velocity streamlines in the NOS3 OE mice were smoother than those in the NOS3+/+ and NOS3−/− mice (Supplementary Fig. S2). Furthermore, the NOS3 OE mouse had significantly lower τw (Fig. 2c) and vorticity (Fig. 2d) than the NOS3+/+ (τw, p < 0.01; vorticity, p < 0.05) and NOS3−/− (τw, p < 0.001; vorticity, p < 0.001) mice, suggesting that lower τw and vorticity were associated with favorable AVF remodeling. Importantly, τw in the NOS3 OE mouse (2.1 ± 1.5 dyne/cm2) was the closest to τw in our baseline, wild-type presurgical mouse jugular vein, which was 1.0 ± 0.3 dyne/cm2, indicating normalization (i.e., return to baseline) of flow in the AVF with favorable remodeling. There was no statistically significant difference in relative helicity (Fig. 2e) and Q-criterion (Fig. 2f) among these mouse strains. Finally, we also calculated the oscillatory shear index at the wall (OSI), which describes the magnitude of change in the blood flow direction over a cardiac cycle and it value ranges between 0 and 0.5. Although large OSI has been associated with pathological arterial remodeling30,31,32, the OSI values in our murine AVFs were low (<0.001) in all three mice and there were no significant differences among them (data not shown).
Because aggressive NH development often occurs at and near the anastomosis, we next investigated the hemodynamic profile of this region (Figs 3 and 4) and compared it to the hemodynamics displayed by the proximal AVF vein (Fig. 5), which is less prone to NH.
Figure 3 shows color maps of velocity and hemodynamic parameters, including both luminal and wall fluid shear stress (FSS), vorticity, relative helicity, and Q-criterion, in a cross-section located at the AVF anastomosis. While all averaged values (i.e., averaged over both a cardiac cycle and cross-sectional area) are smaller in NOS3 OE mice when compared to NOS3+/+ and NOS3−/− mice, it is important to point out that mice with different NOS3 expression levels had distinctly and qualitatively different hemodynamic patterns. The NOS3 OE mouse had higher velocity at the arterial side of the anastomosis, which gradually transitioned to lower velocity at the venous side; this pattern was also observed for FSS and vorticity. In contrast, this smooth transition was not seen in the NOS3+/+ and NOS3−/− mice. Further, there were only two symmetrical areas of relative helicity in the NOS3 OE mouse (one positive, the other negative), suggesting a smooth change in the direction of blood flow from the arterial to the venous side. In contrast, there were several areas of both positive and negative relative helicity in the NOS3+/+ and NOS3−/− mice, suggesting chaotic, disturbed flow. Regions of positive Q-criterion (indicating dominant rotational flow) in the NOS3 OE mouse were small and localized at the arterial side of the anastomosis, while regions of positive Q-criterion in the NOS3+/+ and NOS3−/− mice were larger and present in both the arterial and venous sides of the anastomosis.
Figure 4 shows color maps of velocity and hemodynamic parameters in a cross-section located at the AVF anastomosis junction, where sutures were placed during the AVF creation surgery. Again, mice with different NOS3 expression levels had distinctly and qualitatively different hemodynamic patterns. In the NOS3 OE, velocity was the largest in the lumen center and became smaller gradually and symmetrically toward the wall and zero at the wall, suggesting a fully developed laminar flow pattern. In contrast, velocity in NOS3+/+ and NOS3−/− mice was high throughout most of the cross-section including the wall. Accordingly, the size of helical flow regions (as measured by positive or negative relative helicity) and dominant rotational flow regions (as measured by positive Q-criterion) were smaller in the NOS3 OE mouse than in the NOS3+/+ and NOS3−/− mice. Finally, while luminal and wall FSS in the NOS3 OE was ≤10 dyne/cm2 and FSS in NOS3+/+ and NOS3−/− mice was ≥10 dyne/cm2 throughout the cross-section, vorticity was similar in all three mice at ≥50 1/s.
Figure 5 shows color maps of velocity and hemodynamic parameters in a cross-section located at the proximal AVF vein, which is 5 mm downstream from the AVF anastomosis junction. All values are generally smaller when compared to those at the AVF anastomosis junction, which is likely due to the bigger lumen area at this location than at the AVF anastomosis junction. The averaged velocity, luminal and wall FSS, and Q-criterion in the NOS3 OE mouse were significantly smaller than those in the NOS3+/+ and NOS3−/− mice. Although vorticity was higher in the NOS3 OE and NOS3−/− mice (≤50 1/s) than in the NOS3+/+ mouse (≤20 1/s), the averaged values for all three mouse strains were smaller than that in the AVF anastomosis (Fig. 3g–i) and the AVF anastomosis junction (Fig. 4g–i). Relative helicity patterns were symmetrical with two small and symmetrical regions (one positive, the other negative) of relative helicity in the NOS3 OE mouse, but the relative helicity regions were bigger and more asymmetrical in the NOS3+/+ and NOS3−/− mice. Positive Q-criterion regions were present in the NOS3+/+ and NOS3−/− mice but not the NOS3 OE mouse.
Mouse AVF wall mechanics by FSI
The baseline, wild-type presurgical jugular vein had negligible inner wall circumferential stretch (0.02 ± 0.004%) and radial wall thinning (0.01 ± 0.003 μm). Figure 6 shows the maximum inner wall circumferential stretch and the maximum radial wall thinning, which are averaged over both a cardiac cycle and 7 mm in the AVF vein starting from the anastomosis (140 slices, with 50 μm between 2 slices) or over a cardiac cycle and 1 mm length (20 slices, with 50 μm between 2 slices) at three locations: the AVF anastomosis, AVF anastomosis junction (where sutures were placed), and the proximal AVF vein. Within the 7-mm AVF vein (Fig. 6a,b), the NOS3 OE mouse had lower maximum inner wall circumferential stretch and maximum radial wall thinning when compared to both NOS3+/+ (stretch and thinning, p < 0.05) and NOS3−/− (stretch and thinning, p < 0.05) mice, suggesting that lower stretch and thinning were associated with favorable AVF remodeling. We observe the same patterns when taking a closer look at different regions. At the AVF anastomosis (Fig. 6c,d), the NOS3 OE mouse had lower stretch and thinning when compared to both NOS3+/+ (stretch and thinning, p < 0.01) and NOS3−/− (stretch and thinning, p < 0.001) mice. At the AVF anastomosis junction (Fig. 6e,f), the maximum inner wall circumferential stretch and maximum radial wall thinning were smaller in NOS3 OE than NOS3−/− (p < 0.01 and p < 0.05, respectively). In the proximal AVF vein (Fig. 6g,h), maximum inner wall circumferential stretch and maximum radial wall thinning were smaller in NOS3 OE than both NOS3+/+ and NOS3−/− (p < 0.001 for all comparisons).
Pressure is a critical factor driving vessel wall deformation. We found that the luminal pressure (Fig. 7a) remained low and uniform at approximately 70–73 mmHg over the cardiac cycle at all three locations in the NOS3 OE mouse: the AVF anastomosis (slice 1), AVF anastomosis junction (slice 2) and the proximal AVF vein (slice 3). In contrast, both luminal pressure magnitude and pulsatility were higher in the NOS3+/+ (Fig. 7b) and NOS3−/− (Fig. 7c) mice at the AVF anastomosis (slice 1) and AVF anastomosis junction (slice 2). The results of pressure are consistent with the results of wall deformation.
Figure 8a–i shows color maps of luminal pressure and radial wall thinning in a cross-section at the three locations: the AVF anastomosis (slice 1), the AVF anastomosis junction (slice 2) and the proximal AVF vein (slice 3). Figure 8j–l shows line charts of the values of radial wall thinning along the vessel circumference. The NOS3 OE mouse had minimal radial wall thinning. In contrast, the radial wall thinning in NOS3+/+ and NOS3−/− mice was elevated and asymmetrical along the circumference; peaks of radial wall thinning coincided with local pressure peaks.
Mouse AVF biological responses: cGMP levels and intimal hyperplasia
Figure 9 shows the cGMP levels and intima/media area ratios in the AVFs of all three strains at Day 21. NOS3 OE mice had significantly increased cGMP levels when compared to both NOS3+/+ and NOS3−/− mice (Fig. 9a). Additionally, NOS3 OE mice had a significantly decreased intima/media area ratio compared to the other two strains (Fig. 9b). These results show that overexpression of NOS3 resulted in biological responses beneficial for AVF maturation, i.e., increasing cGMP to relax smooth muscle and decreasing NH formation to maintain a dilated lumen.
Discussion
Our studies found that overexpression of NOS3 led to favorable AVF remodeling (i.e., bigger AVF lumen and smaller NH), smoother blood flow streamlines, as well as lower fluid shear stress at the wall, luminal fluid vorticity, circumferential inner wall stretch, and radial wall thinning. These results establish that NOS3 is a critical molecule driving successful AVF remodeling, and that the effect of NOS3 on AVF remodeling may be mediated, at least in part, through its effect on vascular mechanics (i.e., hemodynamics and wall mechanics).
The mechanisms leading to AVF maturation failure remain poorly understood, but are believed to be related to aggressive NH development and/or insufficient lumen expansion. NO has been well-established as beneficial to vascular health and function in the arterial vasculature23,33. Because the NOS3-derived NO from ECs stimulates vascular SMC relaxation (and hence vessel dilation) by activating guanylate cyclase to upregulate cGMP15,34 and inhibits vascular SMC migration and proliferation24,25, the NOS3-NO system is expected to be beneficial for AVF remodeling. Several publications have supported this notion. In the NO front, Tong et al. isolated SMCs from human vein samples used for creating AVFs in CKD patients and found that NO responsiveness of human venous SMCs in vitro was associated with AVF maturation in vivo35. Additionally, Geenen et al. showed that rats with 5/6 nephrectomy to induce CKD had impaired AVF remodeling and NO-mediated vasodilation, and that administration of soluble guanylate cyclase activator (i.e., BAY 60–2770) to these rats improved their AVF remodeling34. In the NOS3 front, Croatt et al. reported that the administration of NG-nitro-L-arginine methyl ester (L-NAME), a global NOS activity inhibitor non-specific to NOS3, impaired AVF remodeling in rats with normal kidney function36. The present study uses genetically modified mice that overexpress NOS3 (gain-of-function) or do not express NOS3 (loss-of-function) to establish the causal relationship between NOS3 and AVF remodeling. To the best of our knowledge, the present study is the first to provide solid evidence that NOS3 is a critical molecule driving successful AVF remodeling. This is the first innovation of our study.
The second innovation is that our study presents the first FSI study that offers detailed characterization of both hemodynamics and wall mechanics in murine AVFs. It has long been postulated that aberrant vascular mechanics may lead to pathological AVF remodeling, using the analogy that pathological arterial mechanics causes pathological arterial remodeling. For example, atherosclerosis preferentially occurs in regions of arterial branches with disturbed flow, but not in relatively straight arteries where blood flow is usually laminar31,32,37. Furthermore, in tissues, increased blood pressure38,39 and wall stretch39,40 have been shown to induce arterial wall thickening; at the cellular level, wall stretch has been shown to stimulate the proliferation of arterial and venous SMCs41,42,43. In the field of AVF research, several experimental and clinical studies have been performed to investigate the association between hemodynamics and AVF maturation44,45,46,47,48,49,50,51. However, previous studies usually have limitations such as a temporal and spatial resolution of 10 ms and 300 μm for the fluid domain46, assume the wall to be rigid, and only consider FSS at the wall (i.e., τw)46,48. Furthermore, the limited published FSI studies have lower resolution than ours52,53,54 and are focused on comparing the τw values derived from rigid- vs. deformable-wall assumptions53,54. Our FSI study of the murine AVFs has brought several advancements to this field of research. Our temporal resolution is 0.1 ms, our spatial resolution is 0.4 μm for the fluid domain and 0.33 μm for the solid domain, and our solid domain is composed of three layers rather than the more commonly used monolayer50,52 in order to improve the accuracy of simulation results. We also more comprehensively consider the vascular mechanics, presenting velocity, Reynolds number, wall hemodynamic parameters (i.e., τw and OSI), luminal FSS, volumetric hemodynamic parameters (i.e., vorticity, relative helicity, Q-criterion) and wall deformation (i.e., inner wall circumferential stretch and radial wall thinning). We found that smoother blood flow streamlines and lower τw, blood vorticity, inner wall circumferential stretch, and radial wall thinning are associated with favorable AVFs (i.e., larger AVF lumen and smaller NH).
A third innovation of our study is that the communication between NOS3 and vascular mechanics appears to be two-way. The literature thus far has focused on the effect of hemodynamics on NOS3, and not the opposite direction. The effect of blood flow on the NOS3-NO system has been long well recognized in the arterial system. In 1996, Cooke’s group reported that laminar τw induced the release of NO from cultured human aortic ECs55. Since then, it has been well-established that laminar τw activates NOS3 and increases its expression, though this effect is not linear. Metaxa et al. exposed cultured bovine aortic ECs to laminar τw ranging from 15 to 100 dyne/cm2 and found the expression of NOS3 increased with τw and reached a plateau at around 40 dyne/cm2 56. Furthermore, when compared to laminar τw, disturbed τw is known to inhibit the expression and/or activation of NOS3 in arterial ECs57. Taken together, these previous studies firmly establish the effect of mechanical stresses on NOS3. The current study, however, suggests the effect of NOS3 on mechanical stresses. Specifically, using the combination of genetically modified mice and FSI simulations, we found that overexpression of NOS3 led to smoother blood flow streamlines and lower τw, blood vorticity, inner wall circumferential stretch, and radial wall thinning in the AVF, whereas genetic ablation of NOS3 led to more chaotic blood flow streamlines and higher τw, blood vorticity, inner wall circumferential stretch, and radial wall thinning in the AVF. These results suggest that the expression levels of NOS3 can regulate vascular mechanics, especially in the vein.
Our focus on the vein is yet another innovation of our study. Although the effect of blood flow on the NOS3-NO system is well established in the arterial system, it has not been extensively investigated in the venous system. Arterial structure and function are significantly different from venous structure and function58,59,60. For example, the arterial wall is thicker and has more vascular SMCs than the venous wall59. The phenotype of arterial and venous ECs and SMCs are also significantly different20,21,22. For example, the Eph family transmembrane ligand, ephrinB2, is expressed in arterial ECs and it receptor tyrosine kinase, Eph receptor B4 (EphB4), is expressed in venous ECs21. Importantly, it has been shown that endothelium-dependent relaxation is greater in the mammary artery than in the saphenous vein61. Thus, the influences of NOS3-NO signaling axis may differ between the artery and the vein. While the direct comparison between arteries and veins is beyond the scope of our study, we found that overexpression of NOS3 led for favorable AVF vein’s remodeling, possibly through increasing cGMP to relax smooth muscle and decreasing NH formation to preserve open lumen.
Finally, with regard to clinical applications, our study suggests that strategies to increase the availability of NO directly (e.g., by delivering NO) or indirectly (e.g., by upregulating NOS3 expression and/or activation) may be effective at promoting AVF maturation. Currently AVF maturation failure has no effective treatment in the clinical setting and remains a huge unmet clinical need. Novel therapies directed at targets that can prevent AVF maturation failure is of high clinical significance. Specifically, therapies that can positively modify hemodynamic adaptation and also tailored to improve “vein” adaptation following AVF creation would be novel and significant to improve AVF outcomes. Our study suggests that NO-based pathways may be a potential therapeutic target to modify hemodynamics and biology in the venous environment.
Our study has several strengths. It combines the use of genetically modified animals and an image-based biomechanical modeling method that allows for mechanistic studies of NOS3 biology and vascular mechanics. Previous biomechanical modeling of AVFs has largely used the rigid-wall assumption in CFD simulations27,28,62,63,64,65. Limited FSI studies have found that velocity and τw values derived from the rigid-wall assumption in CFD simulations and those from the deformable-wall assumption in FSI are comparable, though the τw values from rigid-wall simulation are about 10–20% bigger54,66, and we have found the same (Supplementary Figs S3 and S4). However, our method has higher temporal and spatial resolution, and we also consider hemodynamic and wall mechanical parameters more comprehensively. Thus, our study offers a more detailed profile of the vascular mechanics in AVFs. In addition, our techniques are positioned to be applied to AVF patients in the clinical setting. Our MRI procedure is contrast agent-free, and thus can be used on AVF patients who are known to be susceptible to the toxicity associated with MRI contrast agents67,68. Our MRI-FSI pipeline can also be used to identify regions of potential stenosis, enabling early detection and treatment of AVF stenosis. Current clinical methods typically require a drop in the volumetric flow rate by Doppler ultrasound to identify stenosis, and is the most reliable when stenosis is significant. Our methods offer several improvements, including that it has higher spatial resolution and lower inter-user variability than ultrasound.
The limitations in our study are primarily related to the higher demands of in vivo information needed for performing FSI simulations, which introduce additional assumptions for the wall structural parameters and mechanical properties, and additional boundary conditions of the AVF. Here, we assumed a homogenous and linearly elastic artery and vein wall; we also assumed that the boundaries of the AVF (distal and proximal artery, proximal AVF vein) were fixed and did not allow translational or rotational motion during the simulation. Future FSI simulations of AVFs could consider heterogeneous vascular wall thickness and mechanical properties, and relax assumptions at the AVF boundaries, when this information becomes available, so that the simulation domain would more closely resemble the AVF’s natural structural properties, mechanical properties, and behaviors.
In conclusion, when compared to wild-type and NOS3 knockout, overexpression of NOS3 leads to favorable AVF remodeling (i.e., larger AVF lumen and smaller NH), smoother blood flow streamlines, as well as lower fluid shear stress at the wall, blood vorticity, inner wall circumferential stretch, and radial wall thinning. Our results show that NOS3 drives successful AVF remodeling, which may be mediated by the AVF vascular mechanics. These results suggest that enhancing NOS3 expression may be an effective strategy to promote AVF maturation.
Methods
All animal studies and experiments were approved by the University of Alabama at Birmingham Institutional Animal Care and Use Committee (IACUC) and performed in accordance with National Institutes of Health guidelines.
Mouse strains and AVF creation surgery
C57BL/6 mice (NOS3+/+) and NOS3 knockout mice (NOS3−/−) on C57BL/6 background were purchased from Jackson Laboratories, Bar Harbor, ME. Transgenic mice overexpressing the human NOS3 gene (NOS3 OE) on C57BL/6 background were described in previous publications69,70. The varying NOS3 expression levels in these three mouse strains before AVF creation were confirmed by Western Blot (Supplementary Fig. S5). We have described the procedures required to create AVFs in mice28. Briefly, an end (vein) to side (artery) fistula was surgically created between the jugular vein and carotid artery (Supplementary Fig. S1), similar to human venous end-to-arterial side AVFs. We have applied the MRI-FSI pipeline described below on several mice from each strain. We present the results from a representative analysis (n = 1) for each strain in this paper.
MRI image acquisition
MRI image acquisition was performed using procedures we have described28. Briefly, a two-dimensional (2D) time-of-flight (ToF) sequence was used to visualize the global AVF lumen geometry and determine the appropriate and optimal orientations of the remaining scans. Next, a 2D T2-weighted fast spin echo sequence was used with a black-blood (BB) double inversion preparation to visualize the vessel lumens at a higher spatial resolution than 2D ToF imaging; these 2D BB images were used to create the 3D geometry of the AVF fluid domain as described immediately below. Next, a 2D gradient echo velocity mapping sequence was used to obtain the velocity over a cardiac cycle at three locations in the AVF: proximal artery, distal artery, and proximal AVF vein. These velocity profiles were extracted as described in “AVF blood flow extraction” and then used both as the velocity boundary conditions of the arteries as well as to calculate the pressure boundary condition of the proximal AVF vein in simulations.
Lumen segmentation, reconstruction, and meshing to build the AVF lumen geometric model
The vascular lumen was segmented manually from the 2D BB images using Amira 5.2.1 (Visage Imaging, Inc., San Diego, CA), reconstructed to a 3D surface in STL format, and then smoothed in Amira28. This smoothed reconstruction was used to create a high-resolution tetrahedral 3D mesh in ANSYS ICEM 15.0 (ANSYS, Inc., Canonsburg, PA). 1.5 × 106 tetrahedra in the lumen (i.e., the fluid domain) were chosen for all simulations based on the mesh independence we performed28.
AVF blood flow extraction
Blood flow velocity over a cardiac cycle was extracted from 2D gradient echo velocity mapping scans using Segment 1.9 (Medviso SB, Lund, Sweden).
CFD modeling of the fluid domain (i.e., the blood flow) in FSI simulations
The fluid domain of our AVF lumen geometric model was simulated using a procedure that was modified significantly from that described previously by us which assumed the vessel wall to be rigid28; several modifications were made in the present study which assumes the vessel wall to be deformable. First, while the proximal and distal artery still used velocity boundary conditions for CFD modeling as previously described28, the boundary condition for the proximal AVF vein is now prescribed as a pressure waveform calculated from the two-element R-C Windkessel model. This model uses the measured blood flow in the proximal artery, lumped downstream vascular resistance (R) and compliance (C) to estimate a pulsatile pressure waveform in blood flow71. Using pressure values from the literature for mice72,73, we estimated R and C values of the downstream proximal AVF vein for each individual mouse. Second, for coupling with the solid domain in FSI simulations, the Navier-Stokes equations were expressed in arbitrary Lagrangian-Eulerian (ALE) form53. The blood properties (assumed to be incompressible and Newtonian) and the temporal discretization strategies (time step = 0.1 ms; approximately 800–1200 time steps over the cardiac cycle) for the pulsatile blood flow were as described by us28.
Finite element modeling of the structural domain (i.e., the vessel wall) in FSI simulations
The structural domain of the vessel wall was modeled using discrete-Kirchhoff-theory-based shell finite elements53, which extruded outwards from the outermost fluid mesh layer into the solid domain consisting of three mesh layers. We used three layers instead of the more commonly used single mesh layer53,54 in order to improve the accuracy of simulation results. The AVF wall mesh contains a total of approximately 0.3 million elements. The wall thickness was 0.01 and 0.005 mm for the mouse artery and vein, respectively74,75. Young’s modulus and Poisson’s ratios were defined as 120 kPa and 0.4 respectively for the mouse artery, and 80 kPa and 0.4 for the mouse vein76,77. Two-way transient FSI was performed in ANSYS Workbench, implicitly coupling the blood flow simulation in ANSYS Fluent to the vessel wall deformation in ANSYS Mechanical. The FSI boundary conditions were (i) equal displacement of the fluid and solid domains and (ii) equilibrium of forces at the fluid-solid interface. Convergence criteria was set at 1 × 10−5 for all residuals.
Post-processing
To investigate the vascular mechanics of the AVF, we calculated the hemodynamic parameters and the wall mechanical parameters, using Tecplot 360 (Tecplot, Inc., Bellevue, WA). The hemodynamic parameters include both wall and volumetric components. Wall hemodynamic parameters include: (i) the magnitude of fluid shear stress (FSS, Equation 1; τ = shear stress; x, y, z = coordinates) at the wall (τw, Equation 2; w = wall), which is the frictional force at the blood-vessel wall interface, and (ii) the oscillatory shear index at the wall (OSI, Equation 3; t = time in the cardiac cycle), which is the magnitude of change in the blood flow direction over a cardiac cycle and it value ranges between 0 and 0.5, with 0 indicating no change and 0.5 indicating full directional reversal. Volumetric hemodynamic parameters include: (i) vorticity (Ω, Equation 4; u = the blood velocity vector), which is the magnitude of blood rotation with no directional component78; (ii) relative helicity (Equation 5), which is a normalized measurement of the direction of blood rotation ranging from +1 (completely clockwise) to −1 (completely counterclockwise)79; and (iii) Q-criterion (Equation 6; S = the shear strain rate), which is a measurement of the dominance of parallel blood flow (e.g., in the direction of bulk flow) or rotational blood flow; positive Q-criterion indicates dominant rotational blood flow and a possible vortex, negative Q-criterion indicates dominant parallel flow with little rotation and no vortex, and zero Q-criterion indicates equal magnitudes of rotational and parallel blood flow80. The wall mechanical parameters include inner wall circumferential stretch (Equation 7) and radial wall thinning (Equation 8). Finally, the Reynolds number is a unitless measure of flow turbulence and defined as |u|D/ν, where |u| = the blood velocity magnitude, D = diameter of the vessel at any cross-section, and ν = blood kinematic viscosity.
The lumen centerline vectors and the tangential vectors to the centerline for each vessel were calculated using Vascular Modeling Toolkit (VMTK); these were then used to determine circumferential slices tangential to the centerline. Mean ± standard deviation (SD) of the parameters (listed above) in these cross-sectional slices were calculated at the distal artery, AVF anastomosis, proximal artery, and proximal AVF vein, every 50 μm. τw and OSI were calculated at each mesh node of the lumen wall (i.e., the outermost layer of the fluid domain, which is also the innermost layer of the solid domain). Vorticity, relative helicity, and Q-criterion were calculated at each mesh node of the lumen volume. Inner wall circumferential stretch was calculated in cross-sectional slices of the lumen wall (i.e., the innermost layer of the solid domain) perpendicular to the lumen centerline; the baseline circumference was the minimum circumference over the cardiac cycle. Radial wall thinning was calculated at each mesh node of the lumen wall, in cross-sectional slices perpendicular to the lumen centerline; the baseline wall thickness was the maximum wall thickness over the cardiac cycle. Reynolds number was calculated in cross-sectional slices of the lumen volume. All parameters (except OSI) were averaged over a cardiac cycle unless otherwise mentioned.
cGMP analysis from AVF veins
Blood vessels were snap frozen at the time of tissue harvest and then analyzed for cGMP using a commercial enzyme immunoassay kit (GenScript®, Piscataway, NJ) according to the manufacturers’ instructions. The levels of cGMP were expressed as pmol/mg protein.
Morphometric analysis to obtain intima/media area ratios
Formalin-fixed and paraffin-embedded AVF samples were cut into thin sections. 10–12 slides of 5 μm sections were obtained by selecting the first of every 10 sections beginning at the venous side of the AVF anastomosis. Morphometric analysis was performed by using Russell-Movat pentachrome-stained slides. Briefly, digital photographs of each tissue section were taken at final magnification of 10X. Intimal and medial regions were manually outlined and tissue areas were measured by using Cellsense Dimension Software (Olympus Life Science). The ratio of intimal area to medial area was calculated for each tissue section and mean value for the intimal to medial area ratio was reported for each animal.
Statistical methods
Group comparisons of simulation results were performed in GraphPad Prism 6 (GraphPad Software, Inc., La Jolla, CA) by paired t-test (if data followed a normal distribution) or Wilcoxon signed-rank test (if data did not follow a normal distribution), with significance set at p < 0.05. The levels of cGMP and the intima/media area ratios were compared using ANOVA, with significance set at p < 0.05.
Data Availability
The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.
Change history
24 October 2019
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
References
Gibson, K. D. et al. Vascular access survival and incidence of revisions: a comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study. J Vasc Surg 34, 694–700, https://doi.org/10.1067/mva.2001.117890 (2001).
Allon, M. et al. Relationships Between Clinical Processes and Arteriovenous Fistula Cannulation and Maturation: A Multicenter Prospective Cohort Study. American Journal of Kidney Diseases 71, 677–689, https://doi.org/10.1053/j.ajkd.2017.10.027 (2018).
Lee, T. et al. Decreased Cumulative Access Survival in Arteriovenous Fistulas Requiring Interventions to Promote Maturation. Clin J Am Soc Nephro 6, 575–581, https://doi.org/10.2215/Cjn.06630810 (2011).
Astor, B. C. et al. Type of vascular access and survival among incident hemodialysis patients: the Choices for Healthy Outcomes in Caring for ESRD (CHOICE) Study. J Am Soc Nephrol 16, 1449–1455, https://doi.org/10.1681/ASN.2004090748 (2005).
Lok, C. E. et al. Cumulative patency of contemporary fistulas versus grafts (2000–2010). Clin J Am Soc Nephrol 8, 810–818, https://doi.org/10.2215/CJN.00730112 (2013).
Dhingra, R. K., Young, E. W., Hulbert-Shearon, T. E., Leavey, S. F. & Port, F. K. Type of vascular access and mortality in U.S. hemodialysis patients. Kidney Int 60, 1443–1451, https://doi.org/10.1046/j.1523-1755.2001.00947.x (2001).
Dember, L. M. et al. Effect of clopidogrel on early failure of arteriovenous fistulas for hemodialysis: a randomized controlled trial. JAMA 299, 2164–2171, https://doi.org/10.1001/jama.299.18.2164 (2008).
Huijbregts, H. J. et al. Hemodialysis arteriovenous fistula patency revisited: results of a prospective, multicenter initiative. Clin J Am Soc Nephrol 3, 714–719, https://doi.org/10.2215/CJN.02950707 (2008).
Feldman, H. I. et al. Predictors of successful arteriovenous fistula maturation. Am J Kidney Dis 42, 1000–1012 (2003).
Allon, M. & Robbin, M. L. Increasing arteriovenous fistulas in hemodialysis patients: problems and solutions. Kidney Int 62, 1109–1124, https://doi.org/10.1111/j.1523-1755.2002.kid551.x (2002).
Roy-Chaudhury, P. et al. Neointimal hyperplasia in early arteriovenous fistula failure. Am J Kidney Dis 50, 782–790, https://doi.org/10.1053/j.ajkd.2007.07.019 (2007).
Corpataux, J. M., Haesler, E., Silacci, P., Ris, H. B. & Hayoz, D. Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access. Nephrol Dial Transplant 17, 1057–1062 (2002).
Roy-Chaudhury, P., Sukhatme, V. P. & Cheung, A. K. Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17, 1112–1127, https://doi.org/10.1681/ASN.2005050615 (2006).
Hofmann, F., Ammendola, A. & Schlossmann, J. Rising behind NO: cGMP-dependent protein kinases. J Cell Sci 113, 1671–1676 (2000).
Joannides, R. et al. Nitric-Oxide Is Responsible for Flow-Dependent Dilatation of Human Peripheral Conduit Arteries in-Vivo. Circulation 91, 1314–1319 (1995).
Higman, D. J. et al. Smoking impairs the activity of endothelial nitric oxide synthase in saphenous vein. Arterioscl Throm Vas 16, 546–552, https://doi.org/10.1161/01.Atv.16.4.546 (1996).
Vallance, P. & Hingorani, A. Endothelial nitric oxide in humans in health and disease. Int J Exp Pathol 80, 291–303, https://doi.org/10.1046/j.1365-2613.1999.00137.x (1999).
Malovrh, M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis 39, 1218–1225, https://doi.org/10.1053/ajkd.2002.33394 (2002).
Wong, V. et al. Factors associated with early failure of arteriovenous fistulae for haemodialysis access. Eur J Vasc Endovasc Surg 12, 207–213 (1996).
Chi, J. T. et al. Endothelial cell diversity revealed by global expression profiling. Proc Natl Acad Sci USA 100, 10623–10628, https://doi.org/10.1073/pnas.1434429100 (2003).
Shin, D. et al. Expression of ephrinB2 identifies a stable genetic difference between arterial and venous vascular smooth muscle as well as endothelial cells, and marks subsets of microvessels at sites of adult neovascularization. Dev Biol 230, 139–150, https://doi.org/10.1006/dbio.2000.9957 (2001).
Deng, D. X. et al. Molecular signatures determining coronary artery and saphenous vein smooth muscle cell phenotypes: distinct responses to stimuli. Arterioscler Thromb Vasc Biol 26, 1058–1065, https://doi.org/10.1161/01.ATV.0000208185.16371.97 (2006).
Huynh, N. N. & Chin-Dusting, J. Amino acids, arginase and nitric oxide in vascular health. Clin Exp Pharmacol Physiol 33, 1–8, https://doi.org/10.1111/j.1440-1681.2006.04316.x (2006).
Cai, H. & Harrison, D. G. Endothelial dysfunction in cardiovascular diseases - The role of oxidant stress. Circulation Research 87, 840–844 (2000).
Kang, H. Y., Fan, Y. B. & Deng, X. Y. Vascular smooth muscle cell glycocalyx modulates shear-induced proliferation. migration, and NO production responses. Am J Physiol-Heart C 300, H76–H83, https://doi.org/10.1152/ajpheart.00905.2010 (2011).
Rudic, R. D. et al. Direct evidence for the importance of endothelium-derived nitric oxide in vascular remodeling. Journal of Clinical Investigation 101, 731–736, https://doi.org/10.1172/Jci1699 (1998).
He, Y. et al. Serial analysis of lumen geometry and hemodynamics in human arteriovenous fistula for hemodialysis using magnetic resonance imaging and computational fluid dynamics. J Biomech 46, 165–169, https://doi.org/10.1016/j.jbiomech.2012.09.005 (2013).
Pike, D. et al. High resolution hemodynamic profiling of murine arteriovenous fistula using magnetic resonance imaging and computational fluid dynamics. Theor Biol Med Model 14, 5, https://doi.org/10.1186/s12976-017-0053-x (2017).
Winter, D. C. & Nerem, R. M. Turbulence in Pulsatile Flows. Ann Biomed Eng 12, 357–369, https://doi.org/10.1007/Bf02407780 (1984).
Ding, Z. R., Wang, K. Q., Li, J. & Cong, X. S. Flow field and oscillatory shear stress in a tuning-fork-shaped model of the average human carotid bifurcation. Journal of Biomechanics 34, 1555–1562, https://doi.org/10.1016/S0021-9290(01)00148-8 (2001).
Ku, D. N., Giddens, D. P. & Zarins, C. K. & Glagov, S. Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation - Positive Correlation between Plaque Location and Low and Oscillating Shear-Stress. Arteriosclerosis 5, 293–302, https://doi.org/10.1161/01.Atv.5.3.293 (1985).
Lee, S. W., Antiga, L., Spence, J. D. & Steinman, D. A. Geometry of the carotid bifurcation predicts its exposure to disturbed flow. Stroke 39, 2341–2347, https://doi.org/10.1161/Strokeaha.107.510644 (2008).
Pacher, P., Beckman, J. S. & Liaudet, L. Nitric oxide and peroxynitrite in health and disease. Physiol Rev 87, 315–424, https://doi.org/10.1152/physrev.00029.2006 (2007).
Geenen, I. L. et al. Nitric Oxide Resistance Reduces Arteriovenous Fistula Maturation in Chronic Kidney Disease in Rats. PLoS One 11, e0146212, https://doi.org/10.1371/journal.pone.0146212 (2016).
Tong, X. et al. Smooth Muscle Nitric Oxide Responsiveness and Clinical Maturation of Hemodialysis Arteriovenous Fistulae. Am J Pathol 187, 2095–2101, https://doi.org/10.1016/j.ajpath.2017.05.006 (2017).
Croatt, A. J. et al. Characterization of a model of an arteriovenous fistula in the rat: the effect of L-NAME. Am J Pathol 176, 2530–2541, https://doi.org/10.2353/ajpath.2010.090649 (2010).
Cunningham, K. S. & Gotlieb, A. I. The role of shear stress in the pathogenesis of atherosclerosis. Lab Invest 85, 9–23, https://doi.org/10.1038/labinvest.3700215 (2005).
Boutouyrie, P. et al. Association between local pulse pressure, mean blood pressure, and large-artery remodeling. Circulation 100, 1387–1393 (1999).
Humphrey, J. D. Mechanisms of arterial remodeling in hypertension: coupled roles of wall shear and intramural stress. Hypertension 52, 195–200, https://doi.org/10.1161/Hypertensionaha.107.103440 (2008).
Carallo, C. et al. Evaluation of common carotid hemodynamic forces - Relations with wall thickening. Hypertension 34, 217–221, https://doi.org/10.1161/01.Hyp.34.2.217 (1999).
Wilson, E., Sudhir, K. & Ives, H. E. Mechanical strain of rat vascular smooth muscle cells is sensed by specific extracellular matrix/integrin interactions. J Clin Invest 96, 2364–2372, https://doi.org/10.1172/JCI118293 (1995).
Predel, H. G. et al. Implications of Pulsatile Stretch on Growth of Saphenous-Vein and Mammary Artery Smooth-Muscle. Lancet 340, 878–879 (1992).
Li, Q., Muragaki, Y., Ueno, H. & Ooshima, A. Stretch-induced proliferation of cultured vascular smooth muscle cells and a possible involvement of local renin-angiotensin system and platelet-derived growth factor (PDGF). Hypertens Res 20, 217–223 (1997).
Back, M. R., Maynard, M., Winkler, A. & Bandyk, D. F. Expected Flow Parameters Within Hemodialysis Access and Selection for Remedial Intervention of Nonmaturing Conduits. Vasc Endovasc Surg 42, 150–158, https://doi.org/10.1177/1538574407312648 (2008).
Besarab, A., Lubkowski, T., Vu, A., Aslam, A. & Frinak, S. Effects of systemic hemodynamics on flow within vascular accesses used for hemodialysis. Asaio J 47, 501–506, https://doi.org/10.1097/00002480-200109000-00021 (2001).
Dammers, R. et al. The effect of flow changes on the arterial system proximal to an arteriovenous fistula for hemodialysis. Ultrasound Med Biol 31, 1327–1333, https://doi.org/10.1016/j.ultrasmedbio.2005.03.017 (2005).
Pietura, R. et al. Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access. Eur J Radiol 55, 113–119, https://doi.org/10.1016/j.ejrad.2004.09.010 (2005).
Remuzzi, A. et al. Radial artery wall shear stress evaluation in patients with arteriovenous fistula for hemodialysis access. Biorheology 40, 423–430 (2003).
Lockhart, M. E., Robbin, M. L. & Allon, M. Preoperative sonographic radial artery evaluation and correlation with subsequent radiocephalic fistula outcome. J Ultras Med 23, 161–168, https://doi.org/10.7863/jum.2004.23.2.161 (2004).
Parmar, J., Aslam, M. & Standfield, N. Pre-operative radial arterial diameter predicts early failure of arteriovenous fistula (AVF) for haemodialysis. Eur J Vasc Endovasc 33, 113–115, https://doi.org/10.1016/j.ejvs.2006.09.001 (2007).
Masengu, A., McDaid, J., Maxwell, A. P. & Hanko, J. B. Preoperative radial artery volume flow is predictive of arteriovenous fistula outcomes (vol 63, pg 429, 2016). Journal of Vascular Surgery 63, 1133–1133 (2016).
de Villiers, A. M., McBride, A. T., Reddy, B. D., Franz, T. & Spottiswoode, B. S. A validated patient-specific FSI model for vascular access in haemodialysis. Biomech Model Mechan 17, 479–497, https://doi.org/10.1007/s10237-017-0973-8 (2018).
Decorato, I. et al. Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula. Int J Numer Method. Biomed Eng 30, 143–159, https://doi.org/10.1002/cnm.2595 (2014).
McGah, P. M., Leotta, D. F., Beach, K. W. & Aliseda, A. Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechan 13, 679–695, https://doi.org/10.1007/s10237-013-0527-7 (2014).
Tsao, P. S., Buitrago, R., Chan, J. R. & Cooke, J. P. Fluid flow inhibits endothelial adhesiveness - Nitric oxide and transcriptional regulation of VCAM-1. Circulation 94, 1682–1689 (1996).
Metaxa, E. et al. Nitric oxide-dependent stimulation of endothelial cell proliferation by sustained high flow. Am J Physiol-Heart C 295, H736–H742, https://doi.org/10.1152/ajpheart.01156.2007 (2008).
Won, D. et al. Relative reduction of endothelial nitric-oxide synthase expression and transcription in atherosclerosis-prone regions of the mouse aorta and in an in Vitro model of disturbed flow. American Journal of Pathology 171, 1691–1704, https://doi.org/10.2353/ajpath.2007.060860 (2007).
Aird, W. C. Phenotypic heterogeneity of the endothelium I. Structure, function, and mechanisms. Circ Res 100, 158–173, https://doi.org/10.1161/01.RES.0000255691.76142.4a (2007).
Canham, P. B., Finlay, H. M. & Boughner, D. R. Contrasting structure of the saphenous vein and internal mammary artery used as coronary bypass vessels. Cardiovasc Res 34, 557–567, https://doi.org/10.1016/S0008-6363(97)00056-4 (1997).
Shiu, Y. T. et al. Preoperative Vascular Medial Fibrosis and Arteriovenous Fistula Development. Clin J Am Soc Nephro 11, 1615–1623, https://doi.org/10.2215/Cjn.00500116 (2016).
Luscher, T. F. et al. Difference between Endothelium-Dependent Relaxation in Arterial and in Venous Coronary-Bypass Grafts. New Engl J Med 319, 462–467, https://doi.org/10.1056/Nejm198808253190802 (1988).
Bozzetto, M., Ene-Iordache, B. & Remuzzi, A. Transitional Flow in the Venous Side of Patient-Specific Arteriovenous Fistulae for Hemodialysis. Annals of biomedical engineering 44, 2388–2401, https://doi.org/10.1007/s10439-015-1525-y (2016).
Browne, L. D. et al. In Vivo Validation of the In Silico Predicted Pressure Drop Across an Arteriovenous Fistula. Annals of biomedical engineering 43, 1275–1286, https://doi.org/10.1007/s10439-015-1295-6 (2015).
Krishnamoorthy, M. K. et al. Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula. Kidney International 74, 1410–1419, https://doi.org/10.1038/ki.2008.379 (2008).
Kharboutly, Z., Deplano, V., Bertrand, E. & Legallais, C. Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Medical engineering & physics 32, 111–118, https://doi.org/10.1016/j.medengphy.2009.10.013 (2010).
Alimohammadi, M. et al. Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models. Biomedical engineering online 14, https://doi.org/10.1186/s12938-015-0032-6 (2015).
Kuo, P. H., Kanal, E., Abu-Alfa, A. K., Cowper, S. E. & Gadolinium-based, M. R. contrast agents and nephrogenic systemic fibrosis. Radiology 242, 647–649, https://doi.org/10.1148/radiol.2423061640 (2007).
Perazella, M. A. Current Status of Gadolinium Toxicity in Patients with Kidney Disease. Clin J Am Soc Nephro 4, 461–469, https://doi.org/10.2215/Cjn.06011108 (2009).
Jones, S. P. et al. Endothelial nitric oxide synthase overexpression attenuates congestive heart failure in mice. Proc Natl Acad Sci USA 100, 4891–4896, https://doi.org/10.1073/pnas.0837428100 (2003).
Jones, S. P. et al. Endothelial nitric oxide synthase overexpression attenuates myocardial reperfusion injury. Am J Physiol Heart Circ Physiol 286, H276–282, https://doi.org/10.1152/ajpheart.00129.2003 (2004).
Shi, Y., Lawford, P. & Hose, R. Review of zero-D and 1-D models of blood flow in the cardiovascular system. Biomed Eng Online 10, 33, https://doi.org/10.1186/1475-925x-10-33 (2011).
Hai, J., Ding, M., Guo, Z. & Wang, B. A new rat model of chronic cerebral hypoperfusion associated with arteriovenous malformations. Journal of neurosurgery 97, 1198–1202, https://doi.org/10.3171/jns.2002.97.5.1198 (2002).
Kojima, T. et al. The relationship between venous hypertension and expression of vascular endothelial growth factor: hemodynamic and immunohistochemical examinations in a rat venous hypertension model. Surgical neurology 68, 277–284; discussion 284, https://doi.org/10.1016/j.surneu.2006.10.075 (2007).
Kang, L. et al. A new model of an arteriovenous fistula in chronic kidney disease in the mouse: beneficial effects of upregulated heme oxygenase-1. American journal of physiology. Renal physiology 310, F466–476, https://doi.org/10.1152/ajprenal.00288.2015 (2016).
Langer, S. et al. Functional and structural response of arterialized femoral veins in a rodent AV fistula model. Nephrol Dial Transplant 24, 2201–2206, https://doi.org/10.1093/ndt/gfp033 (2009).
Bund, S. J. Spontaneously hypertensive rat resistance artery structure related to myogenic and mechanical properties. Clinical science 101, 385–393 (2001).
Guo, X. & Kassab, G. S. Variation of mechanical properties along the length of the aorta in C57bl/6 mice. Am J Physiol Heart Circ Physiol 285, H2614–2622, https://doi.org/10.1152/ajpheart.00567.2003 (2003).
Pereira, V. M. et al. Evaluation of the influence of inlet boundary conditions on computational fluid dynamics for intracranial aneurysms: a virtual experiment. J Biomech 46, 1531–1539, https://doi.org/10.1016/j.jbiomech.2013.03.024 (2013).
Lorenz, R. et al. 4D Flow Magnetic Resonance Imaging in Bicuspid Aortic Valve Disease Demonstrates Altered Distribution of Aortic Blood Flow Helicity. Magn Reson Med 71, 1542–1553, https://doi.org/10.1002/mrm.24802 (2014).
Keshavarz-Motamed, Z. & Kadem, L. 3D pulsatile flow in a curved tube with coexisting model of aortic stenosis and coarctation of the aorta. Med Eng Phys 33, 315–324, https://doi.org/10.1016/j.medengphy.2010.10.017 (2011).
Acknowledgements
The authors would like to thank the UAB-UCSD O’Brien Core Center for Acute Kidney Injury Research (P30 DK079337) for performing all mouse AVF surgeries and UAB preclinical imaging core facility for mouse MRI imaging. TL is supported by grants R44DK109789 from National Institutes of Diabetes, Digestive and Kidney Diseases (NIDDK), R01HL139692 from the National Heart, Lung, and Blood Institute (NHLBI), and I01BX003387 from a Department of Veterans Affairs Merit Award. YTS is supported by a grant (R01DK100505) from NIDDK and I01BX004133 from a Department of Veterans Affairs Merit Award. CGK is supported by HL113303 and GM121307 from the National Institutes of Health.
Author information
Authors and Affiliations
Contributions
D.P. performed all post-MRI image analysis, FSI simulations, initial development, and revision of the manuscript. Y.T.S. contributed to data interpretation, initial development, and revision of the manuscript. Y.F.C., H.L., J.D.S., and C.G.K. contributed to data interpretation and revision of the manuscript. C.G.K. contributed the NOS OE mice. M.S. and T.I. contributed with animal surgery, necropsies, and histology. M.S. performed morphometric analysis. T.I. performed cGMP analysis. L.G. contributed animal surgery. J.T. performed all MRI scans and contributed to interpretation of these scans. T.L. was the principal investigator for this study and contributed to the AVF surgery, MRI scans, initial development, and revision of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Pike, D., Shiu, YT., Cho, YF. et al. The effect of endothelial nitric oxide synthase on the hemodynamics and wall mechanics in murine arteriovenous fistulas. Sci Rep 9, 4299 (2019). https://doi.org/10.1038/s41598-019-40683-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-40683-7
- Springer Nature Limited
This article is cited by
-
Effects of endothelial nitric oxide synthase on mouse arteriovenous fistula hemodynamics
Scientific Reports (2023)