Abstract
Magnetic resonance (MR) T1 and T2* mapping allows quantification of liver relaxation times for non-invasive characterization of diffuse liver disease. We hypothesized that liver relaxation times are not only influenced by liver fibrosis, inflammation and fat, but also by air in liver segments adjacent to the lung – especially in MR imaging at 3T. A total of 161 study participants were recruited, while 6 patients had to be excluded due to claustrophobia or technically uninterpretable MR elastography. Resulting study population consisted of 12 healthy volunteers and 143 patients who prospectively underwent multiparametric MR imaging at 3T. Of those 143 patients, 79 had normal liver stiffness in MR elastography (shear modulus <2.8 kPa, indicating absence of fibrosis) and normal proton density fat fraction (PDFF < 10%, indicating absence of steatosis), defined as reference population. T1 relaxation times in these patients were significantly shorter in liver segments adjacent to the lung than in those not adjacent to the lung (p < 0.001, mean of differences 33 ms). In liver segments not adjacent to the lung, T1 allowed to differentiate significantly between the reference population and patients with steatosis and/or fibrosis (p ≤ 0.011), while there was no significant difference of T1 between the reference population and healthy volunteers. In conclusion, we propose to measure T1 relaxation times in liver segments not adjacent to the lung. Otherwise, we recommend taking into account slightly shorter T1 values in liver segments adjacent to the lung.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Introduction
Magnetic resonance (MR) imaging of the liver is a powerful tool in diagnosis of focal liver disease and is frequently used in clinical routine1,2. Most conventional liver MR sequences measure relative signal intensities and therefore allow relative comparison between focal disease and adjacent normal hepatic parenchyma3. However, detection and quantification of diffuse liver disease remains challenging4 but is desirable to avoid invasive and expensive biopsies5.
Currently, existing non-invasive imaging biomarkers for diffuse liver disease include proton density fat fraction (PDFF) calculation6 and MR elastography7,8. Another emerging technique is the quantification of T1 relaxation time on parametric maps, which is routinely used in cardiac imaging9, for example in diffuse cardiac fibrosis10,11 or myocarditis12. Recently, the modified Look-Locker inversion recovery sequence (MOLLI) demonstrated great potential for application in diffuse liver disease13,14.
However, as known from cardiac applications, reference values should be established for different manufacturers, technical parameters and field strengths before using T1 mapping in clinical routine15,16. Further, it is known from cardiac imaging that T1 values might be influenced if measured in the ventricle close to the lung, why usually measurements in the septum are preferred17. Therefore, specific anatomical conditions of the liver with adjacent air-containing lungs and potential internal confounders, such as hepatic fat and iron composition, should be considered in hepatic T1 mapping2.
We hypothesized that T1 relaxation time is significantly shorter in liver segments adjacent to the lung than in liver segments not adjacent to the lung due to air-induced susceptibility effects at 3T.
Results
Patient characteristics
Patient characteristics are shown in Table 1. Patients without steatosis but with increased liver stiffness (shear modulus ≥ 2.8 kPa) showed a male predominance (78% males vs. 43% males in patients without fibrosis), a higher prevalence of diabetes (35% vs. 3%, p < 0.001), elevated GGT (110 ± 143 vs. 30 ± 33, p < 0.001), and prolonged extrinsic coagulation times (Quick 81 ± 20% vs. 99 ± 3%, p < 0.001). There was a tendency for more tobacco smokers in the group with increased liver stiffness, without statistical significance (p = 0.091). None of the patients was taking empagliflozin and only one patient was taking ezetimibe, both known to reduce liver fat as measured with PDFF18,19.
Image quality
Out of 143 patients and 12 volunteers, resulting in 155 participants, there was at least one segment of good diagnostic image quality in 152/155 participants (98%) for T1 and in 149/155 participants (96%) for T2* (Table 2). In the right liver, segments V-VIII were measurable in at least 90% of the patients for T1. For T2*, the left liver segments were just measurable in 21–40%, while on the right side, the cranial right segments (VII and VIII) were measurable in 61–63% of patients and the right caudal segments (V and VI) were measurable in 86–88% of patients.
Location-based mapping results
As shown in Table 3 and demonstrated in Fig. 1, T1 values were significantly lower in the cranial slices than in the caudal slices (mean of the differences 33 ms, p < 0.001). This did not count for the comparison between cranial segment II and caudal segment III, where no significant difference between both segments was detected (6 ms, p = 0.365). Values between segments were very comparable on each level, except for segment II, which showed values more comparable with the caudal level segments (Table 3). The same tendencies, but less pronounced, were observed for T2*.
Normal T1 values in reference patients were as follows: T1 = 780 ± 83 ms (segments not adjacent to the lung) and 746 ± 81 ms (segments adjacent to the lung) (Table 4). There were no significant differences between the younger healthy volunteers and the reference population (p = 0.358 for T1 and p = 0.521 for T2*).
In positive patients with steatosis as well as in patients with increased liver stiffness, T1 relaxation time was significantly longer than in the reference population (p = 0.019 and p = 0.011 and p < 0.001 for steatosis only, increased stiffness ≥ 2.8 kPa only and increased stiffness ≥ 3.5 kPa only, respectively). These results are illustrated in Fig. 2.
Multivariate analysis
In multivariate analysis of patients and volunteers without focal or diffuse liver disease, T2* time was a significant confounder of T1 time (p < 10−15), while PDFF, age and sex (p = 0.249, 0.722, 0.687, respectively) were not (Fig. 3).
Inter-reader reliability
The ICC values were excellent for both T1 and T2*, as measured in segment VI. The ICC was 0.97 (95%-CI: 0.91–0.99) for T1 and 0.91 (95%-CI: 0.78–0.97) for T2*.
Discussion
This study shows that T1 relaxation time is significantly shorter in liver segments adjacent to the lung than in liver segments not adjacent to the lung. We calculated a mean T1 value of 780 ± 83 ms at 3T in liver segments not adjacent to the lung (segments II, III, IVb, V, VI), while T1 was around 30 ms shorter in liver segments adjacent to the lung (segments IVa, VII, VIII) in a patient population, without focal (based on CT) or diffuse (based on PDFF and MR elastography) liver disease.
This difference may be explained by different reasons. One possibility are susceptibility effects from adjacent air in the lungs. Susceptibility differences between liver and lungs cause off-resonance, which may lead to T1 underestimation. Similar effects are known from myocardial T1 mapping20,21. In addition, there is a T2-dependency of the MOLLI based T1 mapping sequence due to its bSSFP design, therefore influencing the measured T1 value. Another explanation might be partial volume effects at the liver dome since the slice thickness is 10 mm (Fig. 4), which is also known from neuroimaging22. However, the regions of interests (ROI) were drawn carefully to exclude liver vessels and outer 10 mm of the liver border, to prevent this possible bias as much as possible.
While differences between cranial and caudal segments in the right liver lobe and segment IVa vs. IVb were comparable, the T1 relaxation time difference between segment II and III was smaller. A potential explanation for this different behaviour might be that segment II is in close anatomical neighborhood to the heart and not to the lungs as the cranial segments VII, VIII and IVb are. We therefore propose to measure T1 relaxation time in liver segments V and VI with excellent inter-reader-reliability, when a representative T1 quantification of the liver is intended. These segments are normally targeted for liver biopsy and may be regarded as representative for the whole liver. However, for a more detailed segmental analysis of T1 relaxation times in the liver shorter normal T1 values in liver segments adjacent to the lung should be taken into account. T2* seems to be more prone to respiratory and pulsation artefacts from the beating heart, which might explain lower image quality in segments of the left liver lobe (adjacent to the heart) and in cranial segments, while image quality in caudal left segment V and VI showed the best image quality. Electrocardiography gating might improve image quality, which was not tested in this study.
There are very few published data on normal T1 values of the liver at 3T using the MOLLI technique. Katsube et al. presented a mean value of 836 ± 69 ms in 16 patients with normal liver function. The slightly lower values in our study (780 ± 83 ms in reference patients, 799 ± 59 ms in healthy volunteers) may be explained by a smaller population in the study of Katsube et al., as well as the by the fact that Katsube et al. defined the normal population based on normal liver function in laboratory tests, which does not exclude patients with steatosis or early liver fibrosis23. Other published normal T1 values were generated with other mapping techniques, but are nevertheless in a similar range, such as 824 ± 61 ms in 26 healthy volunteers using a spiral GRAPPA-based method24, 825 ± 49 ms in 6 healthy volunteers using an inversion recovery method with refocusing pulses25, and 745 ± 65 ms in 8 healthy volunteers using MR fingerprinting26. Slight differences might be explained by different techniques of assessment and small sample sizes used in the cited studies. This underlines the recommendation, that normative values should be established for the particular site and set-up for different manufacturers, technical parameters and field strengths before using T1 mapping in clinical routine15,16. In accordance with other published studies, increased T1 time correlated with increased liver stiffness in MR elastography as a non-invasive surrogate for liver fibrosis2,13,14,23. Yoon et al. published T1 values in patients with chronic liver disease (863 ± 81 ms) and Child A liver cirrhosis (879 ± 86 ms)27 in the same range as we present here (849 ± 107 ms for early liver fibrosis and 910 ± 98 ms for significant fibrosis). T1 values calculated with commercially available software solutions using the MOLLI mapping technique have been shown to correlate with the severity of NAFLD/NASH and fibrosis28 and may predict clinical outcome in these patients29. We demonstrated an increased T1 time in patients with steatosis, which is in accordance with other published studies30. This is a paradox, since fat has a much shorter T1 time than water. According to recent publications, off-resonance effects in imaging voxels containing a mixture of fat and water signals may explain this finding31,32.
In addition to fat and fibrosis content as well as susceptibility-effects in liver segments adjacent to the lung, there are several other potential confounders of T1 and T2*. One known confounder inducing T1 shortening is liver iron content2,33, however patients with iron overload have been excluded in this study. Liver blood distribution and oxygenation levels are might influence T1 and T2* times as well. These effects and possible influences on T1 and T2* need further investigation. In multivariate analysis of reference patients without focal or diffuse liver disease and healthy volunteers, we could not demonstrate a significant age- or sex- dependency of the measured T1 values. However, there was a collinearity between T1 and T2* values. Further research should be performed to show whether T1 is T2* dependent (e.g. due to fat, iron composition, blood distribution and eventually blood oxygenation influencing T2*) or whether it is the other way round and T2* is influenced by T1 due to a too short TR in the used T2*-mapping sequence. Also using a multiparametric approach combining T1, T2*, MRE and PDFF might deliver further insights.
Our study highlights the importance of standardized technical parameters and well-defined normal values when performing T1 mapping of the liver. For an accurate non-invasive characterization of diffuse liver disease, a combined analysis of different MR parameters such as T1 mapping, T2* mapping, elastography and PDFF should be performed. Further research will show how a multiparametric combination of those MR imaging biomarkers may help differentiating and quantifying diffuse liver disease.
Limitations
Our study has several limitations. First, we focused on a population without known chronic liver disease. Due to the study design and associated ethical considerations, liver biopsy was not possible. Instead, we used MR elastography and PDFF, which have been shown to correlate very well with biopsy-confirmed fibrosis34 and steatosis grades35, as the non-invasive gold standard, and we included negative and positive controls based on these imaging techniques. Another limitation is that we did not obtain full 3D coverage of the liver, as we used commercially available Siemens MOLLI sequences with 2D acquisitions on three transverse slices. Nevertheless, we present a segmental comparison of T1 mapping in a reference population, as well as in negative and positive controls. Newer 3D mapping sequences or MR fingerprinting may offer even more applications for future use.
Conclusion
When analysing T1 maps in the liver at 3T, we propose to measure T1 relaxation times in liver segments not adjacent to the lung. Otherwise, we recommend taking into account slightly shorter T1 normal values in liver segments adjacent to the lung.
Methods
Study population
This prospective cross-sectional study was approved by the institutional review board (Kantonale Ethikkomission Bern, IRB number 282–15) and was conducted in accordance with relevant guidelines and regulations after obtaining written patient informed consent. All participants underwent multiparametric MR imaging at 3T in our institution between 03/2016–06/2017, including T1 and T2* mapping, proton density fat fraction (PDFF) quantification and MR elastography.
A total of 161 study participants were recruited, while 6 patients had to be excluded due an incomplete MR exam due to claustrophobia or technically uninterpretable MR elastography. Resulting study population consisted of twelve healthy volunteers without a history of liver disease (negative controls) and 143 patients (Fig. 5). The included 143 patients were selected based on acquired abdominal computed tomography (CT) scans without focal liver disease (cysts > 2 cm, solid lesion >1, prior liver surgery). Out of the 143 patients, we then defined a reference population (n = 79) without focal (based on CT) or diffuse liver disease (based on MR elastography shear modulus < 2.8 kPa and PDFF < 10%). CT scans in the reference population were performed with following indications: trauma (n = 14), abdominal pain (n = 19), infection (n = 23) and tumor search (n = 23). The remaining patients (n = 64) were assigned to positive control groups with diffuse liver disease (MR elastography shear modulus ≥2.8 kPa and/or PDFF ≥10%).
Clinical information and laboratory test results were recorded for the included patients. Clinical parameters included age, gender, body mass index (BMI), history of diabetes or hypertension, daily drug intake, tobacco use and alcohol consumption. Biological parameters included dyslipidemia, platelet count, quick value, total bilirubin levels, gamma-glutamyltranspeptidase (GGT), aspartateaminotransferase (AST), alanine aminotransferase (ALT), alkaline phosphatase, albumin, creatinine and hematocrit.
Sample size estimation
To detect a mean difference in T1 of 5% (=40 ms) between the upper and lower liver segments with a significance level of 0.05 and a power of 0.8, a sample size of 72 was needed. A mean T1 time of 800 ms with standard deviation of 85 ms was based on a pilot readout for sample size calculations.
MR imaging technique
Patients were examined with a 3T-MR system (Verio, Siemens Healthineers) in a fasting state (>6 h). For T1 mapping, we used an axial-acquired, MOLLI single breath-hold sequence (echo time (TE) of 1.01 ms, data acquisition window of 740 ms, inversion time (TI) 225 ms (3 inversion pulses, starting at 65 ms with an increment of 80 ms), flip angle (FA) 35°, 8-mm slice thickness, field-of-view (FOV) 384, matrix 154 × 192 pixels, and scan time of 11 s) with a 3-3-5 design (acquisition during 3 heartbeats, pause during 3 heartbeats for relaxation purposes and acquisition during another 5 heartbeats). T2* mapping was performed with a multiecho gradient echo (GRE) single breath-hold sequence (12 echoes with a TE between 0.93–14.2 ms, TR of 200 ms, FA 18°, FOV 400, 10-mm slice thickness, and scan time of 19 s). T1 and T2* maps were generated on three single slices in the upper, mid and lower liver. PDFF was calculated using the Dixon method with axial T1-weighted axial vibe images (TE of 2.45 ms and 3.68 ms, TR of 5.47 ms, FA 9°, 3-mm slice thickness, and scan time of 22 s) to differentiate patients with and without liver steatosis. For MR elastography, a pneumatic driver (Resoundant) was placed on the right upper quadrant transmitting shear waves by continuous acoustic vibrations with a frequency of 60 Hz. The liver shear stiffness in kPa in the right upper liver lobe was determined with a gradient echo-based elastography sequence (WIP package 622 provided by Siemens Healthineers, 3 single-slice acquisitions with 5-mm slice thicknesses) using the 95% confidence map of stiffness. A shear modulus ≥2.8 kPa was considered to represent early liver fibrosis (corresponding to histology fibrosis grade ≥F1, according to the Metavir staging system), while a shear modulus ≥3.5 kPa was defined as significant liver fibrosis (corresponding to histology fibrosis grade ≥F3)8,36,37.
MR imaging analysis
Prior to any measurements image quality on relaxometry maps was assessed by an experienced radiologist (V.O., 5 years of experience in hepatic imaging). For T1 and T2* mapping, 8 polygonal regions of interest (ROI) were drawn in liver segments II-VIII by the radiologist (V.O.) who was blinded to the patient’s clinical history. In liver segments without excellent image quality (e.g. due to motion artefacts) or in segments that were not captured on any of the three acquired slices, no ROI was drawn at this location, and thus no value was assigned to the respective segment. The mean ROI size was 685 ± 203 mm2. Large blood vessels, bile ducts and regions with partial volume, including air or perihepatic fat at the liver border, were excluded (Fig. 6). Another radiologist (A.H.), who was blinded to the patient’s clinical history and had 7 years of experience in hepatic imaging, measured the shear modulus (in kPa) on MR elastography images and the PDFF (in %) based on in- and out-of-phase DIXON images in the right liver on three slices, using polygonal ROIs to exclude vessels and partial volume at the liver borders. The median value of the three ROIs was then calculated.
Statistical analysis
Analysis was performed with the statistical software package R (version 3.4.1, R Foundation for Statistical Computing)38 and GraphPad Prism (version 7.1, GraphPad Software Inc.). Clinical characteristics were compared between groups using the Wilcoxon test for continuous variables or Fisher’s exact test for categorical variables. The p-value for significance was <0.05. T1 and T2* mapping parameters with good quality were then compared between segments using a paired Wilcoxon test. To address intersegmental variability and to identify the best area for reference, the median values of the liver segments adjacent to the lung (VII, VIII, IVa) and those not adjacent to the lung (VI, V, IVb, II, III) were calculated for the reference population and compared with the negative and positive controls using the Wilcoxon test.
To assess possible confounders in the reference population and among healthy volunteers (n = 79 + 12), a multivariate regression model was used with T1 (segments not adjacent to the lung) as the outcome and sex (dummy-coded), age, PDFF and T2* (segments not adjacent to the lung) as variables. Age and sex were chosen as basic demographic characteristics that might bias the measured T1 in the liver while PDFF and T2* were added as known representatives of liver fat and iron content that might influence T1. Pearson correlation was used to compare MR elastography shear modulus with T1 values. For interrater reliability, T1 and T2* relaxation time was measured in segment VI in 20 randomly selected consecutive patients by a second radiologist (A.H.), who was blinded to the patient’s clinical history and had 7 years of experience in hepatic imaging. The two-way consistency intraclass correlation (ICC) was then calculated and classified as follows: ICC 0.4-0.59 defined as fair; 0.6–0.74 defined as good; and 0.75–1.00 defined as excellent39.
Human subject research
This prospective cross-sectional study was approved by the institutional review board (IRB number 282-15) and was conducted after obtaining written patient informed consent.
Data Availability
Data generated for analysis during this study are included in this published article. Original patient data files are precluded from dissemination following Swiss Federal Law regulations (https://www.admin.ch/opc/de/officialcompilation/2013/3381.pdf). Data requests may be sent to: Kantonale Ethikkommission für die Forschung Murtenstrasse 31, 3010 Bern (Tel. +41 31 633 70 70, Fax +41 31 633 70 71, info.kek.kapa@gef.be.ch).
References
Bartolozzi, C. MR of the liver: from breakthrough to clinical application. Abdom Imaging 37, 154, https://doi.org/10.1007/s00261-011-9773-2 (2012).
Hoad, C. L. et al. A study of T(1) relaxation time as a measure of liver fibrosis and the influence of confounding histological factors. NMR in biomedicine 28, 706–714, https://doi.org/10.1002/nbm.3299 (2015).
Matos, A. P. et al. Focal liver lesions: Practical magnetic resonance imaging approach. World journal of hepatology 7, 1987–2008, https://doi.org/10.4254/wjh.v7.i16.1987 (2015).
Unal, E., Idilman, I. S. & Karcaaltincaba, M. Multiparametric or practical quantitative liver MRI: towards millisecond, fat fraction, kilopascal and function era. Expert review of gastroenterology & hepatology 11, 167–182, https://doi.org/10.1080/17474124.2017.1271710 (2017).
Dillman, J. R. et al. Quantitative Liver MRI-Biopsy Correlation in Pediatric and Young Adult Patients With Nonalcoholic Fatty Liver Disease: Can One Be Used to Predict the Other? AJR. American journal of roentgenology 210, 166–174, https://doi.org/10.2214/ajr.17.18446 (2018).
Hong, C. W. et al. MRI proton density fat fraction is robust across the biologically plausible range of triglyceride spectra in adults with nonalcoholic steatohepatitis. Journal of magnetic resonance imaging: JMRI, https://doi.org/10.1002/jmri.25845 (2017).
Morisaka, H. et al. Magnetic resonance elastography is as accurate as liver biopsy for liver fibrosis staging. Journal of magnetic resonance imaging: JMRI. https://doi.org/10.1002/jmri.25868 (2017).
Srinivasa Babu, A. et al. Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions. Radiographics: a review publication of the Radiological Society of North America, Inc 36, 1987–2006, https://doi.org/10.1148/rg.2016160042 (2016).
Spiewak, M. T1 and T2 Mapping: The Next Giant Leap in Cardiac Imaging. Cardiology 138, 264–266, https://doi.org/10.1159/000479583 (2017).
Nakamori, S. et al. Native T1 Mapping and Extracellular Volume Mapping for the Assessment of Diffuse Myocardial Fibrosis in Dilated Cardiomyopathy. JACC. Cardiovascular imaging 11, 48–59, https://doi.org/10.1016/j.jcmg.2017.04.006 (2018).
Moon, J. C., Treibel, T. A. & Schelbert, E. B. T1 mapping for diffuse myocardial fibrosis: a key biomarker in cardiac disease? Journal of the American College of Cardiology 62, 1288–1289, https://doi.org/10.1016/j.jacc.2013.05.077 (2013).
von Knobelsdorff-Brenkenhoff, F. et al. Detection and Monitoring of Acute Myocarditis Applying Quantitative Cardiovascular Magnetic Resonance. Circulation. Cardiovascular imaging 10, https://doi.org/10.1161/circimaging.116.005242 (2017).
Banerjee, R. et al. Multiparametric magnetic resonance for the non-invasive diagnosis of liver disease. Journal of hepatology 60, 69–77, https://doi.org/10.1016/j.jhep.2013.09.002 (2014).
Heye, T. et al. MR relaxometry of the liver: significant elevation of T1 relaxation time in patients with liver cirrhosis. European radiology 22, 1224–1232, https://doi.org/10.1007/s00330-012-2378-5 (2012).
Moon, J. C. et al. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement. Journal of cardiovascular magnetic resonance: official journal of the Society for Cardiovascular Magnetic Resonance 15, 92, https://doi.org/10.1186/1532-429X-15-92 (2013).
Bulluck, H. et al. Myocardial T1 mapping. Circulation journal: official journal of the Japanese Circulation Society 79, 487–494, https://doi.org/10.1253/circj.CJ-15-0054 (2015).
Kawel, N. et al. T1 mapping of the myocardium: intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial region. Journal of cardiovascular magnetic resonance: official journal of the Society for Cardiovascular Magnetic Resonance 14, 27, https://doi.org/10.1186/1532-429x-14-27 (2012).
Kuchay, M. S. et al. Effect of Empagliflozin on Liver Fat in Patients With Type 2 Diabetes and Nonalcoholic Fatty Liver Disease: A Randomized Controlled Trial (E-LIFT Trial). Diabetes care 41, 1801–1808, https://doi.org/10.2337/dc18-0165 (2018).
Loomba, R. Role of imaging-based biomarkers in NAFLD: Recent advances in clinical application and future research directions. Journal of hepatology 68, 296–304, https://doi.org/10.1016/j.jhep.2017.11.028 (2018).
Puntmann, V. O., Peker, E., Chandrashekhar, Y. & Nagel, E. T1 Mapping in Characterizing Myocardial Disease: A Comprehensive Review. Circulation research 119, 277–299, https://doi.org/10.1161/circresaha.116.307974 (2016).
Weingartner, S. et al. Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI. Journal of cardiovascular magnetic resonance: official journal of the Society for Cardiovascular Magnetic Resonance 18, 84, https://doi.org/10.1186/s12968-016-0302-x (2016).
Tohka, J. Partial volume effect modeling for segmentation and tissue classification of brain magnetic resonance images: A review. World journal of radiology 6, 855–864 (2014).
Katsube, T. et al. Estimation of liver function using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance imaging. Investigative radiology 46, 277–283, https://doi.org/10.1097/RLI.0b013e318200f67d (2011).
Chen, Y. et al. Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA. Magnetic resonance in medicine 75, 1457–1465, https://doi.org/10.1002/mrm.25693 (2016).
Ding, Y. et al. Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease. European radiology 24, 959–966, https://doi.org/10.1007/s00330-014-3096-y (2014).
Chen, Y. et al. MR Fingerprinting for Rapid Quantitative Abdominal Imaging. Radiology 279, 278–286, https://doi.org/10.1148/radiol.2016152037 (2016).
Yoon, J. H., Lee, J. M., Paek, M., Han, J. K. & Choi, B. I. Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging. European radiology 26, 1775–1782, https://doi.org/10.1007/s00330-015-3994-7 (2016).
Pavlides, M. et al. Multiparametric magnetic resonance imaging for the assessment of non-alcoholic fatty liver disease severity. Liver international: official journal of the International Association for the Study of the Liver 37, 1065–1073, https://doi.org/10.1111/liv.13284 (2017).
Pavlides, M. et al. Multiparametric magnetic resonance imaging predicts clinical outcomes in patients with chronic liver disease. Journal of hepatology 64, 308–315, https://doi.org/10.1016/j.jhep.2015.10.009 (2016).
Henninger, B. et al. Die MRT mit T1- und T2*-Mapping zur Verifizierung einer Steatosis Hepatis - ein Vergleich mit In-Phase und Opposed-Phase-Sequenzen. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 183, WI_PO14 https://doi.org/10.1055/s-0031-1279566 (2011).
Mozes, F. E., Tunnicliffe, E. M., Pavlides, M. & Robson, M. D. Influence of fat on liver T1 measurements using modified Look-Locker inversion recovery (MOLLI) methods at 3T. Journal of magnetic resonance imaging: JMRI 44, 105–111, https://doi.org/10.1002/jmri.25146 (2016).
Thiesson, S. B., Thompson, R. B. & Chow, K. Characterization of T1 bias from lipids in MOLLI and SASHA pulse sequences. Journal of cardiovascular magnetic resonance: official journal of the Society for Cardiovascular Magnetic Resonance 17, W10, https://doi.org/10.1186/1532-429x-17-s1-w10 (2015).
Tunnicliffe, E. M., Banerjee, R., Pavlides, M., Neubauer, S. & Robson, M. D. A model for hepatic fibrosis: the competing effects of cell loss and iron on shortened modified Look-Locker inversion recovery T1 (shMOLLI-T1) in the liver. Journal of magnetic resonance imaging: JMRI 45, 450–462, https://doi.org/10.1002/jmri.25392 (2017).
Yin, M. et al. Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations. Radiology 278, 114–124, https://doi.org/10.1148/radiol.2015142141 (2016).
Permutt, Z. et al. Correlation between liver histology and novel magnetic resonance imaging in adult patients with non-alcoholic fatty liver disease - MRI accurately quantifies hepatic steatosis in NAFLD. Aliment Pharmacol Ther 36, 22–29, https://doi.org/10.1111/j.1365-2036.2012.05121.x (2012).
Singh, S. et al. Diagnostic performance of magnetic resonance elastography in staging liver fibrosis: a systematic review and meta-analysis of individual participant data. Clinical gastroenterology and hepatology: the official clinical practice journal of the American Gastroenterological Association 13, 440–451.e446, https://doi.org/10.1016/j.cgh.2014.09.046 (2015).
Singh, S. et al. Magnetic resonance elastography for staging liver fibrosis in non-alcoholic fatty liver disease: a diagnostic accuracy systematic review and individual participant data pooled analysis. European radiology 26, 1431–1440, https://doi.org/10.1007/s00330-015-3949-z (2016).
R. Core Team. R language definition. (R Foundation for Statistical Computing, 2000).
Cicchetti, D. V. Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology. Psychol Assess 6, 284 (1994).
Acknowledgements
This work was supported by the Swiss National Science Foundation Research Equipment (R’Equip Grant) and Matching Fund from the University of Bern as well as the foundation to fight against cancer. The authors thank the highly motivated MR imaging technicians and image core lab team from the Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital for their support, especially V. Beutler-Minth, Sarah Gfeller, Michelle Schweizer, Géraldine Gemmet, Sandra Feller and Domenica Antosz-Bortoluzzi, as well as Kathrin Dopke from our study coordination division. We thank Siemens for providing access to the MR elastography sequence (WIP622).
Author information
Authors and Affiliations
Contributions
All authors contributed significantly to this manuscript. V.C.O., A.C. and A.T.H. study concepts/study design. V.C.O., A.T.H., A.C., N.M. and C.M. data acquisition or data analysis/interpretation. All authors: manuscript drafting or manuscript revision for important intellectual content. All authors: approval of final version of submitted manuscript. All authors: literature research.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Obmann, V.C., Mertineit, N., Marx, C. et al. Liver MR relaxometry at 3T – segmental normal T1 and T2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness. Sci Rep 9, 8106 (2019). https://doi.org/10.1038/s41598-019-44377-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-44377-y
- Springer Nature Limited
This article is cited by
-
Bacterial association with metals enables in vivo monitoring of urogenital microbiota using magnetic resonance imaging
Communications Biology (2024)
-
Liver T1 and T2 mapping in a large cohort of healthy subjects: normal ranges and correlation with age and sex
Magnetic Resonance Materials in Physics, Biology and Medicine (2023)
-
T1 reduction rate with Gd-EOB-DTPA determines liver function on both 1.5 T and 3 T MRI
Scientific Reports (2022)
-
Magnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging
Nature Reviews Physics (2022)
-
Convolutional neural network for automated segmentation of the liver and its vessels on non-contrast T1 vibe Dixon acquisitions
Scientific Reports (2022)