Abstract
This paper evaluates the effectiveness and safety of XEN63 stent, either standalone or in combination with phacoemulsification, in patients with primary open-angle glaucoma (POAG). Eighty eyes from 80 patients with medically uncontrolled POAG were assigned to undergo XEN63 implant. The primary outcome was the surgical success, defined as an intraocular pressure (IOP) lowering from preoperative values ≥ 20% and an IOP absolute value between 6 and 18 mmHg, with or without antiglaucoma medications. Forty-three (53.7%) eyes underwent XEN63-standalone and 37(46.2%) eyes a XEN63 + Phacoemulsification procedure. Success rate was 68.8% (55/80) eyes in the overall study sample, 69.8% (30/43) eyes in the XEN63-standalone group; and 67.6% (25/37) eyes in the XEN63 + Phaco group (p = 0.6133). Preoperative IOP was significantly lowered from 22.1 ± 4.9 mmHg and 19.8 ± 3.7 mmHg to 14.7 ± 5.3 mmHg and 13.8 ± 3.4 mmHg in the XEN63-standalone and XEN63 + Phaco groups, respectively (p < 0.0001 each, respectively); without significant differences between them at any of the time-points measured. Preoperative number of ocular-hypotensive drugs was significantly reduced from 2.3 ± 0.8 to 0.3 ± 0.7 drugs, from 2.5 ± 0.7 to 0.3 ± 0.7 drugs; and from 2.0 ± 0.8 to 0.3 ± 0.7 drugs, in the overall, XEN63-standalone, and XEN63 + Phaco groups, respectively. Regarding safety, 3(42.5%) eyes had transient hypotony at some point during the study, although only in one (1.2%) eye was clinically significant. Four (5.0%) eyes underwent a needling, 4 (5.0%) eyes underwent surgical-bleb-revision, 1 (1.2%) eye required a device replacement and 1 (1.2%) eye a device removal due to maculopathy. XEN63, either alone or in combination with phacoemulsification, significantly lowered IOP and reduced the number of ocular hypotensive medications. The rate of ocular hypotony was relatively high, although it was clinically relevant only in one eye.
Similar content being viewed by others
Introduction
In patients with glaucoma, lowering intraocular pressure (IOP) is currently considered as the main known modifiable risk factor for preserving visual function1. Although glaucoma treatment must be focused on patient needs, topical hypotensive medications, and selective laser trabeculoplasty are currently considered as the first treatment approach in most patients2. However, some patients do not achieve adequate intraocular pressure reduction and therefore may require surgical intervention2,3,4, such as filtering surgery5, that unfortunately may lead to potential vision-threatening complications6.
Regarding glaucoma surgery, one of its most significant advances in recent years has been the development of the minimally or microinvasive glaucoma surgery (MIGS) devices7. They aimed to provide a safer and less traumatic means of lowering IOP in glaucoma patients7,8.
XEN gel stent device might not be properly defined as a MIGS, as it is a bleb-forming device8; Therefore, it has been suggested minimally invasive or micro-incisional filtration surgery as a more appropriate term for it.
The XEN device is based on the Hagen–Poiseuille law of laminar flow, where the length and the inner diameter of the tube determine the flow-resistance, and therefore, the flow-rate. Three different devices with different inner diameters, namely 45, 63, and 140 μm were investigated9.
The 140 μm XEN device has not been commercialized to date and the evidence is limited to a single paper10. The evidence evaluating the clinical outcomes of the XEN63 device is very limited11,12,13,14,15,16,17 and most studies were performed with an earlier version of the device injector that was never marketed11,12,13,14. The new XEN63 device uses the same needle injector as the XEN45 for preventing early peri-implant flow and hypotony15.
Moreover, as far as we know, this is the first prospective and multicenter study evaluating the clinical outcomes of XEN63 device.
The current study aimed to evaluated the effectiveness and safety of XEN63 stent, either standalone or in combination with cataract surgery (phacoemulsification), in patients with primary open-angle glaucoma (POAG).
Methods
Study design
Prospective, multicenter, non-randomized, and not controlled clinical study conducted on consecutive on patients with medically uncontrolled POAG.
The study protocol was approved by the Ethic Committee of the San Carlos Clinical Hospital (Protocol HCSC-XEN63R1, May 2021).
This study complied with the Good Clinical Practice/International Council for Harmonisation Guidelines, the Declaration of Helsinki, and all applicable country-specific regulations governing the conduct of clinical research, depending on which provided greater protection to the individual.
Written informed consent was obtained in all the patients before the study. Any information that could lead to an individual being identified has been encrypted or removed, as appropriate, to guarantee their anonymity.
Study participants and inclusion/exclusion criteria
This study included patients, aged ≥ 18 years, with insufficiently medically controlled early-to-moderate POAG2; medically treated IOP ≥ 18 and ≤ 33 mmHg; use of ≥ 1 and ≤ 4 ocular hypotensive drugs; Shaffer angle ≥ 3° in the superonasal quadrant; healthy, free, and mobile are of conjunctiva in the selective quadrant; ability to give written informed consent; availability, willingness, and sufficient cognitive awareness to comply with the procedures, indications of the investigator, and schedule of the exam.
Patients with any form of glaucoma other than POAG; previous incisional glaucoma surgery; any surgical procedure on the study eye ≤ 3 months before the start of the study; presence of scars, previous surgeries, or other pathologies in the conjunctival superonasal quadrant; history of corneal surgery; central corneal thickness ≤ 490 or ≥ 620 μm; vitreous in the anterior chamber; presence of intraocular silicone oil; clinically significant inflammation and/or infection in the study eye within 30 days prior to the preoperative visit; impaired episcleral venous drainage; or allergy/sensitivity to any medication required for implantation (including anesthesia), or any of the device components (bovine or porcine products and glutaraldehyde) were excluded.
Surgical technique
All the devices were implanted under local anesthesia. XEN63 implant was placed into the superior quadrant by an ab interno approach15. Subconjunctival mitomycin-C (MMC) (0.1 mL, dose ranged 0.01% and 0.02%) was injected in all the surgeries. The mitomycin-C dose was selected based on surgeon preference and patient characteristics. The device was inserted into the eye through a 1.8 mm corneal paracentesis.
Postoperative care included antibiotic + anti-inflammatory therapy (topical tobramycin and dexamethasone combination) every 2 h during the first postoperative day, which was slowly tapered over 6–8 weeks.
Patients visits
The protocol included one screening visit and one baseline visit. Follow-up visits were scheduled at day-1; week-1 ± 2 days; month-1 ± 7 days; month-3 ± 14 days; month-6 ± 14 days; and month-12 ± 30 days.
Definitions
Surgical success was defined as an IOP lowering from preoperative values ≥ 20% and an IOP absolute value between 6 and 18 mmHg, with or without antiglaucoma medications. Whereas, complete surgical success was defined as an IOP lowering from preoperative values ≥ 20% and an IOP absolute value between 6 and 18 mmHg, without antiglaucoma medications.
Failure was defined as an IOP > 18 mm Hg or a < 20% reduction of IOP from baseline at the end of the follow-up period, need for additional glaucoma surgery, or vision threatening complications that led to severe loss of visual acuity (light perception or worse). Patients with an IOP < 6 mm Hg for more than two consecutive visits were also considered a failure.
Needling or surgical bleb revision, as needed, was indicated in those cases of failure of the procedure due to fibrosis or encapsulation of the bleb that did not respond to massage in the slit lamp and topical hypotensive medications.
Study groups
The study sample was divided in two groups: XEN63-standalone, eyes who underwent XEN implant alone; XEN63 + Phaco, eyes who underwent XEN gel stent implantation combined with phacoemulsification surgery.
Outcomes
The primary end-point was the surgical success rate based on Kaplan–Meier survival analysis.
The secondary end-points included the mean change in IOP from preoperative to month-12; the mean IOP at month-12; the mean change in ocular hypotensive medications from preoperative values to month-12; the proportion of eyes considered as success; and the incidence of adverse events.
Statistical analysis
Statistical analysis was performed with the MedCalc® Statistical Software version 22.002 (MedCalc Software Ltd, Ostend, Belgium; https://www.medcalc.org; 2023).
Only one eye per patient was included. If both eyes met the inclusion/exclusion criteria, the selection of the eye who underwent surgery was left to the discretion of the investigator.
The Shapiro-Wilks test was used for assessing quantitative variables normality.
In normally distribute variables repeated measures ANOVA was used to analyzed the changes in IOP and in number of antiglaucoma medications; while if such variables were no normally distribute, the Friedman test was used.
Repeated analysis of covariance (MANCOVA) was performed to assess the changes in IOP between study groups. The model included “type of surgery” (XEN63-standalone or combined surgery) as a factor and preoperative IOP, number of preoperative ocular hypotensive medications, pachymetry, and MMC dose as covariates.
The Mann–Whitney U test was used for testing preoperative differences between study groups.
A conditional Cox hazard model was used, for both univariate and multivariate analysis, to estimate and test factors for their association with XEN63 device failure. A backward strategy was adopted, with a statistically significant cut-off for variable screening of 0.05.
Factors associated with failure in the univariate analysis at p ≤ 0.1 were included in the multivariate analysis.
Success rates were plotted for study groups using Kaplan–Meier analysis and were compared using a log-rank test.
Categorical variables were compared using a Chi-square test and a Fisher`s exact test, as needed. P value of less than 0.05 was considered significant.
Ethical approval
“All procedures performed in studies involving human participants were in accordance with the ethical standards of the Ethic Committee of the San Carlos Clinical Hospital (Protocol HCSC-XEN63R1, May 2021) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards”.
Informed consent
Written informed consent was obtained in all the patients before the study. Any information that could lead to an individual being identified has been encrypted or removed, as appropriate, to guarantee their anonymity.
Results
Study sample
A total of 80 eyes from 80 patients were included. Forty-three (53.7%) eyes had undergone XEN63-standalone and 37 (46.2%) eyes had undergone a combined procedure (XEN63 + Phacoemulsification).
Preoperative demographic and clinical characteristics
In the overall study sample, the mean age was 71.5 ± 10.2 years, with significant differences between study groups (p = 0.0348). Thirty-seven (46.2%) were women and 80 (100%) were Caucasian. The Table 1 summarizes the main preoperative demographic and clinical characteristics.
Preoperative mean IOP was significantly greater in the XEN-standalone group (22.1 ± 4.9 mmHg) than in the XEN63 + Phaco group (19.8 ± 3.7 mmHg) (Hodges-Lehmann median difference: 2.0 mmHg; 95% CI: 0.0 mmHg to 3.0 mmHg, p = 0.0091).
Similarly, the mean number of preoperative ocular hypotensive medications was significantly greater in the XEN63-standalone than in the XEN63 + Phaco group (Hodges-Lehmann median difference: 1.0 drug; 95% CI: 0.0 to 1.0 drugs, p = 0.0063).
Preoperative visual field was worse in the XEN63-standalone (mean defect: −7.56 ± 4.13 dB) than in the XEN63 + Phaco group (mean defect: −5.28 ± 3.07 dB) (Hodges–Lehmann median difference: −2.30 dB; 95% CI: −4.05 to −0.10 dB, p = 0.0431).
Surgical success
Success rate was 68.8% (55/80 eyes) in the overall study sample, 69.8% (30/43 eyes) in the XEN63-standalone group; and 67.6% (25/37 eyes) in the XEN63 + Phaco group (p = 0.6133). Complete success rate was 62.5% (50/80); 62.8% (27/43); and 62.2% (23/37) in the overall study population, XEN63-standalone group, and XEN63 + Phaco group, respectively; with not significant differences between groups (p = 0.9562).
Table 2 shows the success and complete success rates throughout the follow-up of the study.
In the overall study population, failure occurred in 25 (31.2%) eyes (Fig. 1A). Kaplan–Meier survival analysis indicated no significant differences in the success rate between the XEN63-standalone and the XEN63 + Phaco groups (mean Hazard ratio: 1.28; 95% CI: 0.56 to 2.91; p = 0.5555) (Fig. 1B).
Intraocular pressure
In the overall study population, the mean preoperative IOP was significantly lowered from 21.1 ± 4.5 to 14.3 ± 4.5 mmHg (mean difference: −6.9 mmHg; 95% CI: −8.2 mmHg to −5.6 mmHg, p < 0.0001. Repeated ANOVA) (Fig. 2A).
The mean preoperative IOP was significantly lowered from 22.1 ± 4.9 and 19.8 ± 3.7 mmHg to 14.7 ± 5.3 mmHg and 13.8 ± 3.4 mmHg in the XEN-standalone and XEN + Phaco groups, respectively (p < 0.0001 each, repeated ANOVA). No significant differences were observed between the two study groups at any of the time-points measured (Fig. 2B).
The unadjusted mean IOP lowering at day-1 was significantly greater in the XEN63-standalone group than in the XEN63 + Phaco one (Hodges–Lehmann median difference: −2.0 dB; 95% CI: −4.0 to −0.0 dB, p = 0.0185). No significant differences between the two study groups were observed at any of the other time-points measured (Fig. 3).
After adjusting for different covariates (age, preoperative IOP, preoperative number of ocular hypotensive medications, pachymetry, and dose of MMC) there were no significant differences between both groups at any of the different timepoints measured (Table 3).
Ocular hypotensive medications
In the overall study population, the mean preoperative number of ocular hypotensive medications was significantly reduced from 2.3 ± 0.8drugs to 0.3 ± 0.7 drugs at month-12 (p < 0.0001). Similarly, there was a significant reduction in the number of ocular hypotensive medications in from preoperative values (2.5 ± 0.7 and 2.0 ± 0.8 drugs) to month-12 (0.3 ± 0.7 and 0.3 ± 0.7 drugs) in both XEN63-satandalone and XEN63 + Phaco groups, respectively (p < 0.0001 each, respectively).
There were no statistically significantly differences in mean ocular hypotensive medication reduction between the XEN63-standalone (2.2 ± 1.0 drugs) and the XEN63 + Phaco (1.8 ± 0.9 drugs) groups, p = 0.0656.
Best corrected visual acuity
In the overall study sample, preoperative BCVA was significantly increased from 0.61 ± 0.27 to 0.76 ± 0.23 at month-12 (p = 0.0003). While no significant improvements were observed in BCVA between preoperative and month-12 values in the XEN63-standalone group (mean difference: 0.01 ± 0.25; 95%CI: −0.11 to 0.09; p = 0.8490); BCVA significantly improved from preoperative to month-12 in the XEN63 + Phaco group (mean difference: 0.27 ± 0.25; 95%CI: 0.18 to 0.36; p = 0.0001).
Risk factors
Cox proportional-hazards regression analysis found none factor significantly associated with surgery failure (Table 4).
Safety
Regarding safety, 34 (42.5%) eyes had hypotony (an IOP ≤ 6 mm Hg) at postoperative day-1, which was successfully resolved without sequelae at month-1 in 29 eyes. At month-3, 3 (3.8%) eyes had ocular hypotony, but at month-6 there was no eye with hypotony. Hypotony was subclinical, without maculopathy, in all cases except one, which required removal of the implant at month 1. Two months after implant removal, the BCVA had recovered until reaching preoperative values (0.4).
Besides hypotony, the most commonly reported adverse events were shallow anterior chamber (5/80); corneal Dellen (3/80 eyes); hyphema (3/80 eyes); choroidal detachment (1/80); vitreous wick (1/80); and fibrin in anterior chamber (1/80). These adverse events were mild in severity and were successfully resolved with medical therapy.
Four (5.0%) eyes underwent a needling, 4 (5.0%) eyes underwent surgical bleb revision, 1 (1.2%) eye required a device replacement due to device breakage during needling, and 1 eye a device removal due to hypotonic maculopathy (Table 5).
Discussion
This study aimed to assess the effectiveness and safety of the new XEN63 device in patients with POAG.
According with its results, XEN63, either standalone or in combination with phacoemulsification, lowered significantly the IOP and reduced the number of ocular hypotensive medications over a period of 6 months.
Additionally, this device showed a good safety profile. Although the incidence of ocular postoperative ocular hypotension was relatively high, they were transient and without clinically relevant.
To the best of our knowledge, this is the first prospective and multicenter study evaluating the effectiveness and safety of the new XEN63 device in patients with POAG.
Up to now, only three retrospective studies have been published15,16,17, two of them with a very limited sample size15,16, evaluating the efficacy and safety of the new XEN63 implant.
Fea et al.15 reported a mean (95%CI) IOP lowering effect of − 14.8 (− 20.1 to − 9.5) mmHg, p < 0.0001 at month-3, finding that the mean IOP achieved with XEN63 was consistently lower than that obtained with XEN45.
Additionally, Fea et al.16 found that XEN63 significantly lowered IOP and reduced the number of ocular hypotensive medication over a follow-up period of 18 months in a cohort of patients with different glaucoma phenotypes.
Despite the undoubted clinical value of these studies, the limited sample size, 23 eyes in each study, and the small number of patients undergoing combined surgery (XEN63 + phacoemulsification) (3 eyes in each study, respectively), limit their findings15,16.
In a recently published retrospective study, which compared the effectiveness and safety of the XEN63 and XEN45 devices, it was observed that the XEN63 resulted in higher surgical success rates and fewer postoperative ocular hypotensive medications compared with XEN4517.
According to the results of the current study, mean preoperative IOP was significantly lowered by −7.3 mmHg (95% CI: −8.8 to −5.7 mmHg, p < 0.0001). These figures are lower than those reported by Fea et al.15,16. However, this fact may be due to the great differences in the preoperative IOP between our study (21.1 ± 4.5 mmHg) the Fea et al. studies (27.0 ± 7.8 mmHg and 28.7 ± 6.44 mmHg, respectively)15,16 (p < 0.0001, each, respectively; based on published data). Additionally, this is also supported by the fact that the IOP at month-12 in our study (14.3 ± 4.5 mmHg) and the IOP at 12 months in the study by Fea et al. (14.2 mmHg)16 were similar.
In this study, complete success rate was 62.5% (50/80) eyes in the overall study sample, without significant differences between the XEN63-standalone (62.8%; 27/43) and the XEN63 + Phaco (62.2%; 23/37) groups (p = 0.9562).
This figure is slightly greater than that reported by Hussien et al.17, even taking into account that the success criteria have been different. If we consider the same criteria as Hussein et al. (IOP between 6 and 17 mmHg), success rate of the current study would have been 70.0% (56/80); 65.1% (28/43), and 75.7% (28/37) in the overall, XEN63-standalone, and XEN63 + Phaco groups, respectively.
The IOP lowering effect observed in this study seemed to be, in general terms, slightly greater than that reported with XEN4518,19,20,21.
Regarding the reduction of the number of ocular hypotensive medications, the results of the current study did not significantly differ from those previously published15,16,17.
After adjusting for different variables, this study found no significant differences, in IOP lowering or reduction in the number of ocular hypotensive medications, between those who underwent XEN63-standalone and those who underwent XEN63 + Phacoemulsification.
It is not possible to compare these results with the published literature on XEN63. Based on the studies published with XEN45, the most plausible conclusion is that there is no agreement regarding the superiority of the standalone procedure over the combined procedure with cataract surgery18,19,20,21.
Ocular hypotony, defined as an IOP < 6 mmHg, was observed in 34 (42.5%) eyes at postoperative day 1, although it was successfully resolved in 29 eyes at month-1. Hypotony was subclinical, without maculopathy, in all cases except one, which required removal of the implant at month 1. Two months after implant removal, the BCVA was similar to the preoperative one (0.4).
This rate of hypotony was greater than that reported by Fea et al.15,16, although, as in their case, the hypotonia was transient and resolved without sequelae.
Additionally, in this study 4 (5.0%) eyes underwent a needling procedure, 4 (5.0%) eyes underwent surgical bleb revision, and 2 (2.5%) eyes required a device replacement. The needling rate is much lower than that reported in studies with XEN4518.
This study has several limitations that must be considered when interpreting its results. The first one is its design (non-randomized, open-label, and without control group). Nevertheless, the data were analyzed in a masked fashion. Another limitation is the preoperative IOP differences between the XEN63-standalone and the XEN63 + Phaco groups. Nevertheless, it should be highlighted that this study conducted an ANCOVA analysis, which reduced its impact on the results. Another issue to consider is that the study was conducted in Caucasians with POAG. Appropriate caution is therefore recommended when extending the results to other populations.
Finally, the study was conducted over a limited follow-up period and did not include a control group. Longer follow-up studies comparing XEN63 outcomes with other MIGS devices or trabeculectomy would be welcome.
Conclusions
The results of the current study demonstrated that XEN63, either alone or in combination with phacoemulsification, significantly lowered IOP and reduced the number of ocular hypotensive medications. Although the rate of ocular hypotony was relatively high, it was transient and was not clinically relevant.
Data availability
The datasets used and/or analyzed during the current study available from the corresponding author on reasonable request.
Change history
30 May 2024
A Correction to this paper has been published: https://doi.org/10.1038/s41598-024-63374-4
References
Heijl, A. et al. Reduction of intraocular pressure and glaucoma progression: Results from the Early Manifest Glaucoma Trial. Arch. Ophthalmol. 120, 1268–1279 (2002).
European Glaucoma Society Terminology and Guidelines for Glaucoma, 5th Edition. Azuara Blanco A., Traverso C.E. (eds). Br. J. Ophthalmol. 105 (Suppl 1), 1–169 (2021)
Lichter, P. R. et al. Interim clinical outcomes in the Collaborative Initial Glaucoma Treatment Study comparing initial treatment randomized to medications or surgery. Ophthalmology. 108, 1943–1953 (2001).
Newman-Casey, P. A. et al. The most common barriers to glaucoma medication adherence: A cross-sectional survey. Ophthalmology 122, 1308–1316 (2015).
Landers, J., Martin, K., Sarkies, N., Bourne, R. & Watson, P. A twenty-year follow-up study of trabeculectomy: Risk factors and outcomes. Ophthalmology. 119, 694–702 (2012).
Jampel, H.D. et al Collaborative Initial Glaucoma Treatment Study Group. Perioperative complications of trabeculectomy in the collaborative initial glaucoma treatment study (CIGTS). Am. J. Ophthalmol. 140, 16–22 (2005).
Bar-David, L. & Blumenthal, E. Z. Evolution of glaucoma surgery in the last 25 years. Rambam Maimonides Med. J. 9, e0024 (2018).
Saheb, H. & Ahmed, I. I. Micro-invasive glaucoma surgery: Current perspectives and future directions. Curr. Opin. Ophthalmol. 23, 96–104 (2012).
Lewis, R. A. Ab interno approach to the subconjunctival space using a collagen glaucoma stent. J. Cataract Refract. Surg. 40, 1301–1306 (2014).
Sheybani, A., Dick, H. B. & Ahmed, I. I. Early clinical results of a novel ab interno gel stent for the surgical treatment of open-angle glaucoma. J. Glaucoma 25, 691–696 (2016).
Sheybani, A., Lenzhofer, M., Hohensinn, M., Reitsamer, H. & Ahmed, I. I. Phacoemulsification combined with a new ab interno gel stent to treat open-angle glaucoma: Pilot study. J. Cataract Refract. Surg. 41, 1905–1909 (2015).
Lenzhofer, M. et al. Four-year results of a minimally invasive transscleral glaucoma gel stent implantation in a prospective multi-centre study. Clin. Exp. Ophthalmol. 47, 581–587 (2019).
Fernández-García, A. et al. Comparing medium-term clinical outcomes following XEN® 45 and XEN® 63 device implantation. J. Ophthalmol. 2020, 4796548 (2020).
Lavin-Dapena, C., Cordero-Ros, R., D’Anna, O. & Mogollón, I. XEN 63 gel stent device in glaucoma surgery: A 5-years follow-up prospective study. Eur. J. Ophthalmol. 31, 1829–1835 (2021).
Fea, A. M. et al. Early experience with the new XEN63 implant in primary open-angle glaucoma patients: Clinical outcomes. J. Clin. Med. 10, 1628 (2021).
Fea, A. M. et al. Outcomes of XEN 63 device at 18-month follow-up in glaucoma patients: A two-center retrospective study. J. Clin. Med. 11, 3801 (2022).
Hussien, I. M., De Francesco, T. & Ahmed, I. I. K. Intermediate outcomes of the novel 63 μm gelatin microstent versus the conventional 45 μm gelatin microstent. Ophthalmol. Glaucoma S2589–4196(23), 00078–00079. https://doi.org/10.1016/j.ogla.2023.05.001 (2023).
Chen, X. Z. et al. The outcomes of XEN gel stent implantation: A systematic review and meta-analysis. Front. Med. (Lausanne) 9, 804847 (2022).
Yang, X., Zhao, Y., Zhong, Y. & Duan, X. The efficacy of XEN gel stent implantation in glaucoma: A systematic review and meta-analysis. BMC Ophthalmol. 22, 305 (2022).
Panarelli, J. F. et al. Intraocular pressure and medication changes associated with Xen gel stent: A systematic review of the literature. Clin. Ophthalmol. 17, 25–46 (2023).
Wang, B. et al. XEN gel implant with or without phacoemulsification for glaucoma: A systematic review and meta-analysis. Ann. Transl. Med. 8, 1309 (2020).
Acknowledgements
Medical writing and Editorial assistant services have been provided by Ciencia y Deporte Ltd.
Funding
The medical writer and editorial assistance for this manuscript was supported by AbbVie with no input into the preparation, review, approval and writing of the manuscript. The authors maintained complete control over the manuscript content, and it reflects their opinions.
Author information
Authors and Affiliations
Contributions
Conceptualization: J.M.M., M.T.M.P., E.M.G., S.P.M.; Methodology: J.M.M., T.L., R.G., A.U., M.A.T., S.P.M.; Formal analysis: J.M.L., A.U.; Investigation: J.M.M. M.T.M.P., E.M.G., T.L., R.G., J.M.L., A.U., M.A.T., S.P.M.; Supervision: J.M.M., J.M.L., M.A.T. All authors met the ICMJE authorship criteria. All authors made substantial contributions to conception, design, analysis, and interpretation of data, contributed to writing the article, provided critical revision of the manuscript, and approved the final version.
Corresponding author
Ethics declarations
Competing interests
José María Martínez-de-la-Casa has received funding as consultant from Allergan, Santen, Alcon, Pfizer, Novartis, Thea, B&L, Glaukos, AJL, and VISUfarma, research funding from Santen, Ivantis, Allergan, Pfizer, Glaukos, and Thea, and lecturer funding from Allergan, Santen, Alcon, Pfizer, Novartis, Thea, B&L, Glaukos, and ICare. Maria Teresa Marcos-Parra has received funding as consultant from AbbVie and Allergan. Elena Milla has received funding as consultant from AbbVie, Allergan, Santen, Brill, and Thea. Teresa Laborda has no interests to declare. Rafael Giménez Gómez has received funding as a lecturer from Abbvie, Santen and Brill. José Manuel Larrosa Carrera has received funding as consultant from AbbVie and Johnson&Johnson. Javier Aritz Urcola Carrera has received funding as consultant from AbbVie and Allergan. Miguel Ángel Teus has received funding as a lecturer from Alcon and funding as consultant from Allergan. Susana Perucho Martinez has received funding as a lecturer from AbbVie, Allergan, Visufarma and Thea.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
The original online version of this Article was revised: The Keywords section in the original version of this Article was omitted. It now reads: “Keywords xen, xen-63, Bleb forming devices, Glaucoma, IOP, MIGS, Primary open-angle glaucoma, Subconjunctival MIGS”.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Martínez-de-la-Casa, J.M., Marcos-Parra, M.T., Millá-Griñó, E. et al. Effectiveness and safety of XEN 63 in patients with primary-open-angle glaucoma. Sci Rep 14, 4561 (2024). https://doi.org/10.1038/s41598-024-55287-z
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-024-55287-z
- Springer Nature Limited