Background
Adenosine as a stress agent is well tolerated and has a good safety profile but occasionally when administered at 140mg/kg/min it fails to produce a haemodynamic or symptomatic response.
Studies have reported that between 4 - 18% patients do not respond to the standard dose1, 2.
Splenic switch-off is a novel way of assessing adequacy of hyperaemic response, to adenosine3.
The aim of this study was to assess the number of patients that required an increase in dose to either 175 mg/kg/min or 210 mg/kg/min over a 12-month period and the adequacy of this response using splenic switch-off.
Methods
We retrospectively reviewed all patients who completed an adenosine stress scan in the period from July 2013 to July 2014. We identified those who had not responded to the standard adenosine dose requiring an increased dose. We recorded the physiological response to an increased dose of adenosine, both haemodynamic and/or symptomatic, and visually assessed the presence of splenic-switch off.
Results
Over a year 955 patients had an adenosine stress scan. 74 patients (7.7%) did not respond to the standard dose and the dose was increased to either 175 mg/kg/min or 210 mg/kg/min. 82% (61) of the 74 patients that underwent an increased dose protocol had splenic switch off. See table 1.
Of 11 patients who admitted to taking caffeine 10 (91%) had splenic switch off. 4 patients required the adenosine stopping early because of transient heart block, there were no other complications.
Conclusions
Similar to previous literature only a small percentage of patients in our cohort needed an increased adenosine dose. The majority (82%) subsequently demonstrated splenic switch-off indicating an adequate hyperaemic response. Our findings would support the use of increasing adenosine infusion rates as being both safe and effective. We now routinely increase infusion rates in non-responders, including those who have taken caffeine.
Funding
N/A.
References
Weerackody R, Burchell T, Mohiddin S, Crake T, Mathur A, Westwood M, Davies C: High dose adenosine stress perfusion cardiovascular. Journal of Cardiovascular Magnetic Resonance. 2010, 12 (Suppl 1): P222-10.1186/1532-429X-12-S1-P222.
Karamitsos T, Ntusi N, Francis J, Holloway C, Myerson S, Neubauer : Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance. 2010, 12: 66-10.1186/1532-429X-12-66.
Manisty C, Ripley D, Captur G, Peebles C, Wong T, Schelbert E, Herrey A, Greenwood J, Moon J: ‘Splenic switch-off' to detect adenosine understress; a novel method to improve test sensitivity. Journal of Cardiovascular Magnetic Resonance. 2014, 16 (Suppl 1): O1-10.1186/1532-429X-16-S1-O1.
Author information
Authors and Affiliations
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Walkden, M., Bryant, J., Abbas, A. et al. Turning up the adenosine turns off the spleen. J Cardiovasc Magn Reson 17 (Suppl 1), T1 (2015). https://doi.org/10.1186/1532-429X-17-S1-T1
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-T1