Background
Measurement accuracy of joint kinematics is influenced by how closely the trajectories of surface markers represent the motion of underlying bones [1]. For the Oxford Foot Model (OFM) hindfoot segment, the heel (HEE), lateral calcaneus (LCA) and sustentaculum tali (STL) markers are used to track the movement of the calcaneus [2]. This paper investigates the how changes in marker placement affect the orientation of the OFM hindfoot segment axes.
Methods
Twenty adult females participated in the study (40 feet in total). Radiopaque monitoring electrodes (Type 2223, 3M Healthcare, Neuss, Germany) were placed on the feet at the locations specified by the OFM. CT images (GE 64-slice Lightspeed VCT scanner) were acquired as the subjects lay supine. The 3-Dimensional (3D) coordinates of the electrodes and of the points corresponding to the ideal marker locations were extracted from the images, using Mimics (Materialise NV, Leuven, Belgium). The marker based OFM A-P axis (AP) which extends from HEE to the mid-point (MID) of LCA and STL was calculated. A corrected A-P axis based on the ideal HEE marker location (APH) was also calculated. MID was then adjusted by correcting either LCA or STL to make them equidistant from HEE, as specified by the OFM marker placement protocol. From that, a corrected A-P axis based on the modified MID (APM) was computed. Finally, a fully corrected A-P axis (APC) based on the revised HEE and MID positions were obtained. The transverse plane projections of all the axes (AP, APH, APM, APC) were compared.
Results
The results (Table 1) suggest that correcting the position of either the LCA or the STL marker induced less than 1° of change in the anterior-posterior (A-P) axis for most feet. Whereas, when the HEE marker position was aligned with the correct anatomical location, the orientation of the A-P axis was affected more as both the mean and interquartile (IQR) values infer. There was large variation in its orientation relative to the original A-P axis with a slight medial bias. From regression analysis it was found that, 1 mm of lateral shift in HEE placement was enough to cause approximately 4° of deviation in the A-P axis orientation.
Conclusion
The anteroposterior orientation of the A-P axis is more sensitive to the location of the HEE marker than to the locations of the LCA and STL markers. Therefore, it is essential to ensure that the HEE marker is placed accurately.
References
Della Croce U, Leardini A, Chiari L, Cappozzo A: Human movement analysis using stereophotogrammetry: part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. Gait & Posture. 2005, 21: 226-237. 10.1016/j.gaitpost.2004.05.003.
Stebbins J, Harrington M, Thompson N, Zavatsky AB, Theologis TN: Repeatability of a model for measuring multi-segment foot kinematics in children. Gait Posture. 2006, 23: 401-411. 10.1016/j.gaitpost.2005.03.002.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Paik, A.M., Stebbins, J., Kothari, A. et al. Effect of marker placement on Oxford Foot Model hindfoot segment axes. J Foot Ankle Res 7 (Suppl 1), A62 (2014). https://doi.org/10.1186/1757-1146-7-S1-A62
Published:
DOI: https://doi.org/10.1186/1757-1146-7-S1-A62