We read with great interest the article by Wollersheim and colleagues who examined whole-body vibration (WBV) in intensive care unit patients [1]. Hemodynamic characteristics were monitored during WBV application. The study underscores previous findings showing that no significant changes in heart rate, blood pressure, or oxygen saturation occurred during WBV in critically ill patients, nor when compared with healthy controls [2].
In the present study, unconscious sedated patients received WBV in a flat supine position without any changes in body position, except flexion of the hips and knees. The method raises the question whether enough load was applied to the vibrating plate to lead to a sufficient neuromuscular response. To increase this load and involve neuromuscular recruiting, it might be helpful to modify the patient’s position by inclination of the bed to approximately 20° to 25° degrees of tilt [2]. It is suggested that this would involve a greater muscular proportion of the whole body. In conscious patients, additional training effects may be achieved by the use of a (yet customized) vibrating dumbbell for the upper extremities.
Since the recent method is preliminary in the current setting, potential effects on muscle function and morphology should be assessed in further studies [3]. A short-term response could be detected, e.g., by electromyography [2]. Longer-term effects involve muscular morphology, e.g., hypertrophy, which can be assessed by sonography-based morphometry [4].
It remains debatable whether catecholamines influenced the findings in the present study, since no controls were examined [5].
In summary, WBV, if applicable in conjunction with a vibrating dumbbell, appears safe and feasible in early rehabilitation. Potential beneficial long-term effects remain to be shown.
Abbreviations
- WBV:
-
Whole-body vibration
References
Wollersheim T, Haas K, Wolf S, Mai K, Spies C, Steinhagen-Thiessen E, Wernecke KD, Spranger J, Weber-Carstens S. Whole-body vibration to prevent intensive care unit-acquired weakness: safety, feasibility, and metabolic response. Crit Care. 2017;21(1):9.
Boeselt T, Nell C, Kehr K, Holland A, Dresel M, Greulich T, Tackenberg B, Kenn K, Boeder J, Klapdor B, et al. Whole-body vibration therapy in intensive care patients: a feasibility and safety study. J Rehabil Med. 2016;48(3):316–21.
Jarosch I, Gehlert S, Jacko D, Koczulla RA, Wencker M, Welte T, Bloch W, Janciauskiene S, Kenn K. Different training-induced skeletal muscle adaptations in COPD patients with and without alpha-1 antitrypsin deficiency. Respiration. 2016;92(5):339–47.
Jiménez Siebert M, Boeselt T, Greulich T, Alter P, Herth F, Kahn N, Bornitz F, Vogelmeier C, Nell C, Hummler S et al. Effects of a 6 week whole-body vibration training (WBVT) in stable COPD patients: a randomized clinical trial. Eur Respir J. 2016;48(suppl 60). doi: 10.1183/13993003.congress-2016.PA2216.
Di Loreto C, Ranchelli A, Lucidi P, Murdolo G, Parlanti N, De Cicco A, Tsarpela O, Annino G, Bosco C, Santeusanio F, et al. Effects of whole-body vibration exercise on the endocrine system of healthy men. J Endocrinol Invest. 2004;27(4):323–7.
Acknowledgements
None.
Funding
Not applicable.
Availability of data and materials
Not applicable.
Authors’ contributions
All authors were involved in the intellectual content, interpretation, and in writing the manuscript.
Competing interests
The authors declare that they have no competing interests.
Consent for publication
All authors agree to publish this manuscript in the category Letter-to-the-Editor in Critical Care.
Ethics approval and consent to participate
Not applicable.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Author information
Authors and Affiliations
Corresponding authors
Additional information
See related research by Wollersheim et al. http://ccforum.biomedcentral.com/articles/10.1186/s13054-016-1576-y
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Alter, P., Boeselt, T., Nell, C. et al. Feasibility and safety of whole-body vibration therapy in intensive care patients. Crit Care 21, 91 (2017). https://doi.org/10.1186/s13054-017-1669-2
Published: