Abstract
Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca2+) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH2O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Red blood cells (RBCs) possess excellent mechanical versatility and deformability which enables them to pass through the vessels of the microcirculation and deliver oxygen between blood and tissues. During their life cycles, RBCs (7.5–8.7 μm in diameter) (Diez-Silva et al. 2010) can traverse the circulatory system thousands of times through an extensive network of capillaries (~ 2.5 μm) (Danielczok et al. 2017) or even incredibly smaller splenic inter-endothelial clefts (0.5–1.0 μm) (Liapis et al. 2002). The tension, compression and shear stress experienced by the RBCs lead to ATP release (Cinar et al. 2015; Sikora et al. 2014), rheological property alteration (Chien 1987), nitro oxide generation (Kuck et al. 2020), accelerated glycolysis (Kuchel et al. 2021; Kuchel and Shishmarev 2017) and RBC volume changes. Many of these processes are regulated by the influx of calcium (Brain et al. 2004). The intracellular calcium concentration of unstimulated RBCs is tightly controlled within the range of 30–90 nM (Bogdanova et al. 2013), while the calcium concentration in blood plasma is approximately 1.8 mM (20,000-fold). Increasing evidence has demonstrated that mechanosensitive Ca2+ permeable ion channels expressed on the RBC membranes are key transducers of mechanical stimuli, triggering calcium influx that subsequently regulates the volume of RBCs through the Ca2+-activated K+ channel KCa3.1 (Fig. 1a). To this end, dysregulation of RBC mechanosensing in channelopathies such as hereditary xerocytosis leads to increased intracellular calcium concentration, therefore, dehydrating the cell and accelerating RBC clearance from the bloodstream (Albuisson et al. 2013; Glogowska et al. 2015). However, the cellular events of how RBCs and other mammalian cell types sense mechanical forces and trigger signal transduction are still incompletely understood. To examine the calcium mobilization under controlled mechanical forces, a single-cell platform that can concurrently apply mechanical modulation and visualize calcium mobilization using fluorescent indicators is in great demand.
In the past decades, micropipette aspiration assays have been widely used to mechanically modulate living cells for in-vitro fertilization (Hiraoka and Kitamura 2015; Temple-Smith et al. 1985), gene editing (Rasys et al. 2019; Shao et al. 2014), and characterization of cellular mechanical properties, such as stiffness, viscoelastic modules and membrane tension (Gonzalez-Bermudez et al. 2019; Mierke 2021). With a fashioned open orifice, borosilicate micropipettes integrated with the water manometer can aspirate target live cells in a stepwise manner (Fig. 1b, c):
where ∆h (Table 1) is the fluid level difference between the micropipette tip and the reservoir (Fig. 1c, apparatus i). Such controlled aspiration (∆p) lends a major advantage to micropipette-based methods that minimize cell pre-activation. This is particularly critical for studies on primary cells, such as platelets (Ju et al. 2016) and T-cells (Liu et al. 2014) which are naturally mechanosensitive. With known radii of the micropipette opening (Rp) and the target cell (Rc) (Table 1), the membrane tension (σ) of the aspirated cell can be determined using the law of Laplace (Fig. 1b, top):
Moreover, the pneumatic high-speed pressure clamp (HSPC) device has become a popular assessory tool for patch clamping experiments (Cahalan et al. 2015; Coste et al. 2012; Fogerty et al. 2019; Xue et al. 2020). This is because the pneumatic HSPC is able to apply a high magnitude (∆p = − 200–0 mmHg) and steady (± 1 mmHg) pressure clamp to the aspirated cell rapidly (0 to − 100 mmHg in 1 ms). More recently, micropipette aspiration assays have been combined with fluorescent imaging which enables numerous live-cell mechanobiology studies, including nuclear remodeling (Swift et al. 2013), ion channel mechanogating (Cox et al. 2016), and receptor-mediated mechanosensing (Chen et al. 2015, 2019; Liu et al. 2014). Such instrumental integration provided a direct approach to visualize single-cell mechanosensing (Wang et al. 2022b). Nevertheless, there is lack of technical study to head-to-head benchmark the efficacy of water vs. pneumatic apparatus and their distinct mechanical profiles of aspiration on cell mechanosensing (cf. Figure 1c, apparatus i vs. ii).
Hereby, we implemented both manual water manometer and the pneumatic HSPC for single-cell aspiration. We combined micropipette aspiration assays with confocal microscopy, where we used the intensiometric calcium indicator Cal-520 AM (Fig. 1b, bottom) to visualize the calcium mobilization of human RBCs in real time (Fig. 1c). We also determined the dynamic range of the Ca2+ imaging system with the Cal-520 AM loaded RBCs using calcium ionophore (i.e. A23187) and calcium chelators (i.e. BAPTA AM and EGTA), which were sequentially added to the experimental chambers. Taken together, this method and experimental setup enabled us to accurately calculate the intracellular calcium concentration under controlled mechanical aspiration.
Materials and methods
Reagents
Cal-520 AM (Abcam, Cambridge, UK) was dissolved in dimethyl sulfoxide (DMSO) (2.5 mM) and stored at − 30 °C. Calcium ionophore (5 mM) (A23187; Sigma-Aldrich, US) was dissolved in DMSO and stored at − 30 ℃. BAPTA AM (Thermo Fisher Scientific, Massachusetts, USA) (50 mM) in DMSO, was stored at − 30 °C. EGTA dissolved in Milli-Q water (0.5 M, pH 8) was stored at room temperature with KOH (1:3 w/w). Tyrode’s buffer (12 mM NaHCO3, 10 mM HEPES, 0.137 M NaCl, 2.7 mM KCl, 5.5 mM D-glucose, pH 7.2) supplemented with 1 mM CaCl2 was prepared and stored at room temperature. Carbonate/bicarbonate buffer (2.1 g Na2CO3, 2.65 g NaHCO3 in 250 mL H2O, pH 8.5) was stored at − 4 °C fridge. Clexane (10,000 U/mL, Sigma-Aldrich, St. Louis, MO) was stored at room temperature.
Human RBC isolation and loading with calcium indicators
All procedures involving the collection of human blood from healthy volunteers were approved by the Human Research Ethics Committee of the University of Sydney (HREC 2014/244). RBCs were isolated from the whole blood as previously described (Chen et al. 2015; Ju et al. 2017; Passam et al. 2018). Briefly, the whole blood was drawn and transferred into a 15 mL tube pre-loaded with 1:200 Clexane. Then 5 μL blood was diluted into carbonate/bicarbonate buffer (1 mL) and centrifuged 900×g for 1 min at room temperature. After that, the supernatant was discarded. The washing step was then conducted once with carbonate/bicarbonate buffer and once with Tyrode’s buffer. Finally, the collected RBCs were stored in 200 μL of Tyrode’s buffer at 4 °C.
Isolated RBCs were labeled with 10 μM Cal-520 AM probe for 45 min incubation at room temperature on a vertical spinner. The labeled RBCs were further diluted with a 1:100 ratio in Tyrode’s buffer for experimental use.
Micropipette fabrication
A borosilicate glass capillary tube (G-1; Narishige International, USA) was mounted on the micropipette puller (model P-1000; Sutter Instruments Co., Novato, CA). Two close-end micropipettes would then be fabricated by the pre-set pulling function in the micropipette puller (Heat: 505; Pull: 150; Velocity: 75; Time: 200; Pressure: 400; Ramp 500). Tips of micropipettes were cut and fashioned to 1 µm diameters using a MicroForge (Model MF-900; Narishige International, USA) equipped with a 20 × eyepiece. For detailed operation procedures, please refer to the previously published protocols (Ju 2019).
Homemade height-adjusting water manometer to manually control aspiration pressure
The micropipette holder was sealed and connected to the homemade water manometer implemented with a height adjustment mechanism. First, the micropipette holder was taken off and lowered to under the fluid level of the connected reservoir and allowed water dripping for a few seconds. This step can ensure the absence of air bubble inside the tube connecting the micropipette holder and the water reservoir. Then a fully filled borosilicate micropipette fabricated from the previous section was inserted into the holder tip and the holder screw was tightened (Ju 2019). Finally, due to the tightness of the micropipette–reservoir connection, the aspiration pressure of the borosilicate micropipette was finely controlled by adjusting the height of the connected water reservoir related to the tip of the micropipette in a stepwise manner. To this end, the fluid level in the connected reservoir was crucial to be maintained at a constant level during the aspiration assay. Otherwise, to ensure the accuracy of suction pressure, the zero pressure needs to be immediately re-calibrated once the fluid level changes.
high-speed pressure clamp with aspiration pressure feedback control
A pneumatic high-speed pressure clamp (HSPC-2-SB; ALA Scientific Instruments, Farmingdale, NY) was also used as an alternative way to provide mechanical stimuli to the aspirated RBC as described elsewhere (Cahalan et al. 2015; Cox et al. 2016). The pressure applied was modified by an electrical control panel (Fig. 2c, top). The output voltage from the control panel was delivered to the head stage that is supplemented by both vacuum and pressure generated by pumps (Fig. 2c, bottom) (Besch et al. 2002). Then the voltage would mediate the spacing between the piezo bimorph and the valve seats inside the head stage which finally control the output pressure at the micropipette tip. A pressure sensor was also integrated inside the head stage to monitor the pressure of the closed system (i.e. micropipette aspiration setup). The system was able to apply a maximum aspiration pressure of − 200 mmHg with a ± 0.5 mmHg resolution and 15 ms response time when a 100 mmHg jump was required. In this study, ∆p = − 25–0 mmHg aspiration pressure was applied to observe the calcium mobilization inside the RBCs.
Concurrent imaging of RBC morphology and intracellular calcium
At room temperature, diluted RBC solution (approximately 0.025% hematocrit) was injected into a homemade cell chamber. RBC fluorescence imaging was performed on an Olympus FV3000RS confocal microscope with an IX83 body combined with an FV31-HSU Hybrid Scanning Unit (Tokyo, Japan). Calcium mobilization can then be imaged with laser illumination (Ex 490/Em 525), where 15% power (maximum power: 50 mW) was used in the laser diode. Bright-field imaging was performed simultaneously on the same microscope. Images were illuminated using the silver-coated resonance scanning mirrors at 10 fps and 512 × 512 frame size, controlled with Olympus CellSens Dimension software. Light signals were collected via an Olympus 40 × /0.95 UPLXAPO (Air) objective. Two channels inside the InGaAsP high-sensitivity detector with quantum efficiency > 45% were used to concurrently acquire images of both bright-field light and fluorescent light. The acquisition was performed with averaging every two frames. No significant photobleaching effect was observed during the time interval used in the experiments. All images were then collected with the Olympus FV31S-SW software.
Intracellular calcium concentration analysis
The correlation between the fluorescence intensity of the calcium dye in the imaging system and labeled cells’ intracellular concentration was investigated by determining the dynamic range of fluorescence intensity. By adding 10 μM A23187 + 10 mM CaCl2 or 50 μM BAPTA AM + 10 mM EGTA, the maximum fluorescence intensity, Fmax (a.u.), and minimum fluorescence intensity, Fmin (a.u.) were obtained, respectively. The acquired image was then exported into the analysis software ImageJ (Wayne Rasband, National Institutes of Health) or the commercial software Imaris 9.0.1 (Oxford Instruments, Abingdon, United Kingdom) to perform cell segmentation. To determine the dynamic range based on RBC’s population average, the fluorescence intensity of cells with maximum and minimum fluorescence intensity were then separately plotted with GraphPad Prism v8.0.1 (GraphPad Software Inc., CA, USA) in the form of histograms. Gaussian distributions were fitted to the histograms and the means of distributions were thereafter retrieved as Fpmax and Fpmin, respectively. Calibration will be used for subsequent intracellular calcium concentration (nM) calculation in Eq. (3). The live time fluorescence intensity of the selected cell can be normalized by dividing the cell’s fluorescence intensity at the resting state. The increase of calcium concentration of the aspirated RBC, ∆[Ca2+] is derived by subtracting the calcium concentration of the RBC in the resting state from the aspirated state. The membrane tension of the aspirated RBC is evaluated by the law of Laplace shown in Eq. (2).
Result
Micropipette aspiration of single RBCs on a confocal microscope
To set up micropipette aspiration assays, we first assembled a homemade cell chamber consisting of two metal squares (copper/aluminum) and a handle that links them together. Two pieces of half-cut glass coverslips (40 mm × 11 mm × 0.2 mm) were glued to create a sandwich space with 300 μL Tyrode’s buffer filled up (Fig. 2a, top). After RBCs were injected into the chamber, a fashioned borosilicate micropipette was anchored on the micropipette holder and inserted into the chamber by tuning the micro-manipulator as previously described (Chen et al. 2015; Ju 2019). The micropipette was then approached to grab the target RBC (Fig. 2a, bottom).
The cell aspiration was performed using either (i) the homemade water manometer (Fig. 2b) or (ii) the pneumatic HSPC (Fig. 2c). By adjusting the relative height difference with a 0–40 mm travel range (Fig. 2b), the water manometer provided a relatively small pressure range equivalent to ∆p = − 2.94–0 mmHg. Notably, based on the previous study (Cahalan et al. 2015), this is below the minimum of − 5 mmHg pressure required to observe a significant calcium influx (cuff Fig. 3b, e). To apply stronger negative pressure to the RBC, we connected a pneumatic HSPC to the top of the reservoir (cf Fig. 1c), which can reproducibly perform aspiration with much stronger negative pressure ∆p = − 25–− 5 mmHg (Fig. 2c; cf Fig. 3e).
Quantitation of intracellular calcium signaling in an aspirated RBC
The intracellular calcium mobilization in RBCs was visualized using the calcium indicator Cal-520 AM (Ex 490/Em 525), which exhibits a significantly improved signal-to-noise ratio and intracellular retention as compared to existing green calcium indicators (e.g., Fluo-3 AM and Fluo-4 AM) (Lock et al. 2015). To achieve a combination of RBC calcium imaging with concomitant monitoring of cell morphology under the aspiration pressure, a confocal microscope was set up using a plan apochromatic dry objective with 40 × magnification and 0.95 numerical aperture (Fig. 1c). A filter cube with a 505 nm dichroic mirror was placed in front of the hybrid scan unit which emitted the 488 nm excitation laser to the calcium dye. Human RBCs were isolated and then incubated with a final concentration of 10 μM Cal-520 AM for 45 min on a vertical spinner at room temperature. This loading concentration was shown to have efficient probe uptake by the cells without functional impairment that might be caused by DMSO as the solvent. By utilizing a silver-coated resonance scanning mirror, the system line scanned the aspirated RBC with both fluorescence and bright-field channels. The signals passed through the dichroic mirror and were acquired by a high-sensitivity detector. This imaging setup was designed to directly quantify the calcium mobilization inside the RBC based on its fluorescence intensity, while observe the morphology change during aspiration (Fig. 2a, bottom).
Since the orifice radius of the micropipette was Rp = ~ 0.5 μm, only a small proportion of the RBC can be aspirated into the micropipette, forming an elongating tongue until a steady state is reached (Artmann et al. 1997). As a result, the maximum increase in the Cal-520 intensity observed during aspiration was ~ 50 (a.u.) when the aspiration pressure generated by the water manometer was ∆p = − 25 mmH2O (equivalent to ∆p = − 1.84 mmHg) (Fig. 3a). It reflected a subtle Ca2+ influx as compared to the Cal-520 intensity at the resting state Frest. Moreover, raising the aspiration pressure to the highest level ∆p = -40 mmH2O (equivalent to ∆p = − 2.94 mmHg) failed to further enhance the Ca2+ dependent intensity (Fig. 3b). Indeed, both aspiration pressure resulted in 1.1–1.2-fold increase in the aspirated RBC compared to its resting state (Fig. 3c).
To apply a higher pressure, a pneumatic HSPC device connected to the top of the water reservoir was then used. As expected, the Cal-520 intensity raised rapidly in response to both ∆p = − 5 mmHg and − 25 mmHg pressure during aspiration (Fig. 3d&e), which is similar to the results obtained by Cahalan et al. (Cahalan et al. 2015). Additionally, such increase was pressure-dependent, where the higher pressure led to much greater changes (i.e. ~ twofold under ∆p = − 25 mmHg pressure vs. ~ 1.5-fold under ∆p = − 5 mmHg; Fig. 3f). It is clear that the pneumatic HSPC is more robust in triggering the Ca2+ mobilization than the manual water manometer. Of note, to retrieve the signal only from the RBC without any background noise, seven different image segmentation algorithms were tested: Triangular, Mean, Yen, Li, Otsu, Huang and Isodata (Fig. 3g). Three of them, Li, Otsu and Isodata matched our requirement, and Isodata was chosen as the default thresholding method in this study.
Determining calcium dynamic range of the RBC labeled with Cal-520 AM
The Cal-520 AM provides a robust, homogeneous fluorescence-based assay tool with a single wavelength for detecting intracellular calcium mobilization (Lock et al. 2015). To determine the Cal-520 dynamic range, we would obtain the single aspirated cell maximum (Fmax) and minimum (Fmin) of intracellular fluorescent intensities as previously described (Nesbitt et al. 2012), which can be used. The resting intensity (Fsrest) was first obtained by imaging one Cal-520 loaded RBC for 50 frames (acquisition rate = 10 fps), followed by another 50 frames acquired after the cell was aspirated. Single RBC was then aspirated using either the water manometer (Fig. 4a) or the pneumatic HSPC (Fig. 4b). To obtain Fsmax, 10 μM A23187 was added into the cell chamber supplemented with 10 mM CaCl2. With both aspiration apparatuses, we observed rapid increase in Ca2+ signals until the fluorescent intensity reached a plateau with Fsmax being ~ threefold relative to Fsrest (Fig. 4a&b). Notably it took less time for RBCs aspirated by the pneumatic HSPC to reach Fsmax (e.g. tx = 5–10 s; Fig. 4a), as compared to cells aspirated by the water manometer (e.g. tx = 25–30 s; Fig. 4b). Since BAPTA AM and EGTA chelate intracellular and extracellular calcium ions, respectively, we then added 50 μM BAPTA AM + 10 mM EGTA cocktail to obtain the Fmin. The Cal-520 intensity of the RBC quickly decayed to the background, which was ~ 0.8-fold of the Fsrest baseline level. As a result, neither water manometer nor pneumatic HSPC induced any Ca2+ mobilization inside the RBCs (Fig. 4c&d). Expectantly, both aspiration apparatuses achieved similar outcome of Fsmax and Fsmin; indicating that the Cal-520 dynamic range is independent of the applied mechanical stimuli. This result further demonstrated the validity of the calibrated dynamic range for our cell mechanobiology studies.
From a user-friendly perspective, determining the Cal-520 dynamic range by adding A23187 and BAPTA AM + EGTA from one aspirated cell to another was tedious and labor-intensive. We, therefore, examined whether obtaining the average Fmin and Fmax from a population of RBCs in the field of view during imaging (n ≥ 20) is valid to serve as a once-for-all and efficient alternative approach. First, it is important to validate that the dynamic range obtained from the resting population is identical to the dynamic range obtained from the aspirated single cells. Thus, we pre-loaded a population of RBCs with Cal-520 AM, injected them into the cell chamber and waited until they settled to the bottom of the chamber. Similar to the single-cell determination, frames were initially captured to indicate the Fprest of cells (Fig. 5a, 1st column), which was used as a reference to validate the measured dynamic range. Then, Fpmax and Fpmin of the RBC population were obtained in the same way as aspirated cells. After collecting images under these conditions, histograms of measurements corresponding to each condition were built (Fig. 5b, bottom) and the mean of the histograms can be obtained (Fpmax = 757 and Fpmin = 126) as the population average calibration.
Moreover, the fluorescence intensity of the cell population was also plotted against elapsed time to show the calcium changes over the entire calibration process (Fig. 5c). As indicated, after adding the A23187 and CaCl2, the mean Cal-520 intensity amongst the population of RBCs increased by 2.6-fold relative to the resting state (757 a.u. vs. 292 a.u.; Table 1). On the other hand, the fluorescence intensity slowly dropped to the background as expected after the calcium chelating cocktail was added. Compared to the calibration outcome from the single-cell aspiration assays (i.e. ∆p = − 1.84 mmHg and − 2.94 mmHg from the water manometer; ∆p = -5 mmHg and − 25 mmHg from the pneumatic HSPC), the fluorescence intensity in all tested RBCs increased by 2.5 to 3-fold after A23187 was added (Fig. 5d), and the intensity decayed to the background level under all conditions after the BAPTA AM + EGTA cocktail was added. Taken together, the Cal-520 dynamic range determination from the RBC population is valid to serve as an alternative once-for-all calibration and is transferrible to the single-cell aspiration settings.
Quantitation of RBC cytosolic calcium concentration
To gain more mechanobiological insights into the RBC mechanosensing quantitatively, we further calculated the real-time intracellular calcium concentration [Ca2+] using the following equation (Szydzik et al. 2019):
where KdCal−520 (Table 1) of the Cal-520 AM probe is 320 nM (Lock et al. 2015), F was the instantly measured fluorescence intensity of the aspirated RBC, Fmax = 757 was the maximum mean fluorescence intensity amongst cell population obtained previously, and Fmin = 126 was the minimum mean fluorescence intensity (Fig. 6a). Alternatively, the single-cell maximum, Fsmax = 821 (Table 1), and minimum, Fsmin = 129 were also implemented in calcium concentration calculation. We then calculated calcium concentrations using both calibration methods at different timepoints, where the increase concentration, ∆[Ca2+] (nM) of the aspirated RBC was plotted against the elapsed time tx (s) (Fig. 6b). To this end, identical ∆[Ca2+] is derived by both population average and single aspirated cell calibration, since both Fmax reflected a consistent magnitude of increase amongst resting and different aspiration conditions (two-to-threefold, cf Fig. 5d). This result further demonstrated the validity of implementing population calibration in deriving ∆[Ca2+] in a single aspirated RBC.
Furthermore, when the membrane tension of the aspirated RBC was evaluated by Eq. (2), the peak intracellular calcium concentration, ∆[Ca2+]max was ~ 30 nM and ~ 100 nM at 0.22 and 1.09 mN/m, respectively. It is also worth to note that some RBCs with 1.09 mN/m membrane tension had much larger ∆[Ca2+]max up to the low micromolar range (~ 2000 nM; Fig. 6c). These results clearly indicate that an increasing aspiration can trigger the activation of a Ca2+ permeable mechanosensitive channel on the RBC membrane, causing the [Ca2+] elevation by a hundred times higher than the normal physiological condition (Fig. 6c).
Discussion
Intracellular calcium concentration plays a vital role in RBC physiology and pathophysiology. The calcium signaling is associated with multiple physiological processes (Bogdanova et al. 2013; Hertz et al. 2017); however, the detailed mechanism of how mechanical stimulation triggers this signaling pathway remains unclear. Thus, it is crucial to develop assays that are capable of visualizing calcium mobilization and simultaneously quantifying live-time calcium levels in RBCs under controlled mechanical stimulation. In this study, we developed a micropipette assay coupled with fluorescence imaging using a intensiometric calcium probe Cal-520 AM, which can be used to characterize and quantify the effect of aspiration force on RBC calcium regulation.
Two different aspiration apparatuses, the homemade water manometer and the pneumatic HSPC were implemented, respectively, to aspirate the RBC, which display superiorities in different aspects. It has been demonstrated that − 5 mmHg is a threshold pressure that triggers a detectable increase in the fluorescence intensity of an aspirated RBC (Cahalan et al. 2015). In comparison, limited by its working distance, the strongest pressure that can be delivered by our water manometer is ∆p = − 2.94–0 mmHg. However, with the benefit of the higher signal-to-noise ratio of Cal-520 AM (Lock et al. 2015), we are able to detect and quantify subtle increase in the Cal-520 intensity when gentle pressure was applied (Fig. 3b and c). Nevertheless, our micropipette aspiration assay using the water manometer can minimize the pre-activation of the RBC. On the other hand, the pneumatic HSPC generates a much higher aspiration pressure (− 200–0 mmHg, ± 1 mmHg) than the water manometer. Hereby, it results in a much stonger calcium mobilization in the RBC than when the water manometer is used to aspirate the cell. By implementing the pneumatic HSPC, our fluorescence-coupled micropipette aspiration assay becomes a powerful tool to characterize the RBC calcium mobilization in response to precisely controlled mechanical stimuli. This system allows to characterize the activation mechanism of Ca2+ permeable mechanosensitive ion channels, such as Piezo1, and investigate the mechanotransduction pathways that influence the physiological functions of RBCs.
Operational wise, multiple critical factors determine the success and application of a fluorescence-coupled micropipette assay. First, both incubation time and continuous mixing of the Cal-520 AM dye during the loading process are essential for sufficient dye uptake. It is thus ideal to incubate RBCs and the dye in a tube on a vertical spinner. Second, given that high dose of the solvent of the probe, DMSO, is toxic for living cells, DMSO dilution higher than 1:250 is recommended when loading the Cal-520 AM. Third, to get the best quality of cell segmentation, the thresholding algorithm during calibration needs to be properly selected. Imaris, an integrated commercialized software, can automatically determine the optimal thresholding algorithm itself for image processing and data analysis. Furthermore, when operating the micropipette aspiration, it is critical to level down the tip to the bottom surface, where cells rest. This ensures that the vertical position of the cell will not fluctuate out of the focus, otherwise the measurements of Cal-520 intensity are inaccurate.
Compared to other methods, such as the tonicity assay, micropipette-based techniques are easier to assess and quantify mechanical stimuli and the mechanical properties of cells (Wang et al. 2022b), such as membrane tension using relevant physical models (Fig. 1b) (Mierke 2021). We also provide suggestions on algorithm selection to improve the quality of RBC segmentation in fluorescence images. This advance enables measurements of calcium signaling under fine-tuned mechanical stimuli and improves the efficacy. More importantly, micropipette assays have the potential to be combined with emerging dynamic force spectroscopy methods, such as the biomembrane force probe (Chen et al. 2015) and optical tweezers (Wang et al. 2022a), and be used to measure other types of forces, including tension, compression and shear stress, to study mechanosensing.
Data availability
Data is available on request from the corresponding author. The data are not publicly available due to privacy or ethical restriction.
Code availability
Not applicable.
References
Albuisson J, Murthy SE, Bandell M, Coste B, Louis-Dit-Picard H, Mathur J, Feneant-Thibault M, Tertian G, de Jaureguiberry JP, Syfuss PY, Cahalan S, Garcon L, Toutain F, Simon Rohrlich P, Delaunay J, Picard V, Jeunemaitre X, Patapoutian A (2013) Dehydrated hereditary stomatocytosis linked to gain-of-function mutations in mechanically activated PIEZO1 ion channels. Nat Commun 4:1884
Artmann GM, Sung KL, Horn T, Whittemore D, Norwich G, Chien S (1997) Micropipette aspiration of human erythrocytes induces echinocytes via membrane phospholipid translocation. Biophys J 72:1434–1441
Besch SR, Suchyna T, Sachs F (2002) High-speed pressure clamp. Pflugers Arch 445:161–166
Bogdanova A, Makhro A, Wang J, Lipp P, Kaestner L (2013) Calcium in red blood cells-a perilous balance. Int J Mol Sci 14:9848–9872
Brain MC, Pihl C, Robertson L, Brown CB (2004) Evidence for a mechanosensitive calcium influx into red cells. Blood Cells Mol Dis 32:349–352
Cahalan SM, Lukacs V, Ranade SS, Chien S, Bandell M, Patapoutian A (2015) Piezo1 links mechanical forces to red blood cell volume. Elife. https://doi.org/10.7554/eLife.07370
Chen Y, Liu B, Ju L, Hong J, Ji Q, Chen W, Zhu C (2015) Fluorescence biomembrane force probe: concurrent quantitation of receptor-ligand kinetics and binding-induced intracellular signaling on a single cell. J Visualized Exp 102:e52975
Chen Y, Ju LA, Zhou F, Liao J, Xue L, Su QP, Jin D, Yuan Y, Lu H, Jackson SP, Zhu C (2019) An integrin alphaIIbbeta3 intermediate affinity state mediates biomechanical platelet aggregation. Nat Mater 18:760–769
Chien S (1987) Red cell deformability and its relevance to blood flow. Annu Rev Physiol 49:177–192
Cinar E, Zhou S, DeCourcey J, Wang Y, Waugh RE, Wan J (2015) Piezo1 regulates mechanotransductive release of ATP from human RBCs. Proc Natl Acad Sci 112:11783–11788
Coste B, Xiao B, Santos JS, Syeda R, Grandl J, Spencer KS, Kim SE, Schmidt M, Mathur J, Dubin AE, Montal M, Patapoutian A (2012) Piezo proteins are pore-forming subunits of mechanically activated channels. Nature 483:176–181
Cox CD, Bae C, Ziegler L, Hartley S, Nikolova-Krstevski V, Rohde PR, Ng CA, Sachs F, Gottlieb PA, Martinac B (2016) Removal of the mechanoprotective influence of the cytoskeleton reveals PIEZO1 is gated by bilayer tension. Nat Commun 7:10366
Danielczok JG, Terriac E, Hertz L, Petkova-Kirova P, Lautenschlager F, Laschke MW, Kaestner L (2017) Red blood cell passage of small capillaries is associated with transient Ca(2+)-mediated adaptations. Front Physiol 8:979
Diez-Silva M, Dao M, Han J, Lim CT, Suresh S (2010) Shape and biomechanical characteristics of human red blood cells in health and disease. MRS Bull 35:382–388
Fogerty J, Stepanyan R, Cianciolo LT, Tooke BP, Perkins BD (2019) Genomic non-redundancy of the mir-183/96/182 cluster and its requirement for hair cell maintenance. Sci Rep 9:10302
Glogowska E, Lezon-Geyda K, Maksimova Y, Schulz VP, Gallagher PG (2015) Mutations in the Gardos channel (KCNN4) are associated with hereditary xerocytosis. Blood 126:1281–1284
Gonzalez-Bermudez B, Guinea GV, Plaza GR (2019) Advances in micropipette aspiration: applications in cell biomechanics, models, and extended studies. Biophys J 116:587–594
Hertz L, Huisjes R, Llaudet-Planas E, Petkova-Kirova P, Makhro A, Danielczok JG, Egee S, del Mar M-P, Van Wijk R, Vives Corrons J-L (2017) Is increased intracellular calcium in red blood cells a common component in the molecular mechanism causing anemia? Front Physiol 8:673
Hiraoka K, Kitamura S (2015) Clinical efficiency of Piezo-ICSI using micropipettes with a wall thickness of 0.625 mum. J Assist Reprod Genet 32:1827–1833
Ju L (2019) Dynamic force spectroscopy analysis on the redox states of protein disulphide bonds. Methods Mol Biol 1967:115–131
Ju L, Chen Y, Xue L, Du X, Zhu C (2016) Cooperative unfolding of distinctive mechanoreceptor domains transduces force into signals. Elife 5:e15447
Ju L, Chen Y, Rushdi MN, Chen W, Zhu C (2017) Two-dimensional analysis of cross-junctional molecular interaction by force probes. Methods Mol Biol 1584:231–258
Kuchel PW, Shishmarev D (2017) Accelerating metabolism and transmembrane cation flux by distorting red blood cells. Sci Adv 3:eaao1016
Kuchel PW, Romanenko K, Shishmarev D, Galvosas P, Cox CD (2021) Enhanced Ca(2+) influx in mechanically distorted erythrocytes measured with (19)F nuclear magnetic resonance spectroscopy. Sci Rep 11:3749
Kuck L, Peart JN, Simmonds MJ (2020) Active modulation of human erythrocyte mechanics. Am J Physiol Cell Physiol 319:C250–C257
Liapis H, Foster K, Miner JH (2002) Red cell traverse through thin glomerular basement membrane. Kidney Int 61:762–763
Liu B, Chen W, Evavold BD, Zhu C (2014) Accumulation of dynamic catch bonds between TCR and agonist peptide-MHC triggers T cell signaling. Cell 157:357–368
Lock JT, Parker I, Smith IF (2015) A comparison of fluorescent Ca(2)(+) indicators for imaging local Ca(2)(+) signals in cultured cells. Cell Calcium 58:638–648
Mierke CT (2021) Physics of cancer, vol 3. IOP, pp 5–85
Nesbitt WS, Harper IS, Schoenwaelder SM, Yuan Y, Jackson SP (2012) A live cell micro-imaging technique to examine platelet calcium signaling dynamics under blood flow. Methods Mol Biol 788:73–89
Passam F, Chiu J, Ju L, Pijning A, Jahan Z, Mor-Cohen R, Yeheskel A, Kolsek K, Tharichen L, Aponte-Santamaria C, Grater F, Hogg PJ (2018) Mechano-redox control of integrin de-adhesion. Elife. https://doi.org/10.7554/eLife.34843
Rasys AM, Park S, Ball RE, Alcala AJ, Lauderdale JD, Menke DB (2019) CRISPR-Cas9 gene editing in lizards through microinjection of unfertilized oocytes. Cell Rep 28:2288-2292 e2283
Shao Y, Guan Y, Wang L, Qiu Z, Liu M, Chen Y, Wu L, Li Y, Ma X, Liu M, Li D (2014) CRISPR/Cas-mediated genome editing in the rat via direct injection of one-cell embryos. Nat Protoc 9:2493–2512
Sikora J, Orlov SN, Furuya K, Grygorczyk R (2014) Hemolysis is a primary ATP-release mechanism in human erythrocytes. Blood J Am Soc Hematol 124:2150–2157
Swift J, Ivanovska IL, Buxboim A, Harada T, Dingal PC, Pinter J, Pajerowski JD, Spinler KR, Shin JW, Tewari M, Rehfeldt F, Speicher DW, Discher DE (2013) Nuclear lamin-A scales with tissue stiffness and enhances matrix-directed differentiation. Science 341:1240104
Szydzik C, Brazilek RJ, Akbaridoust F, de Silva C, Moon M, Marusic I, Ooi ASH, Nandurkar HH, Hamilton JR, Mitchell A, Nesbitt WS (2019) Active micropump-mixer for rapid antiplatelet drug screening in whole blood. Anal Chem 91:10830–10839
Temple-Smith P, Southwick G, Yates C, Trounson A, De Kretser D (1985) Human pregnancy by in vitro fertilization (IVF) using sperm aspirated from the epididymis. J in Vitro Fert Embryo Transf 2:119–122
Wang H, Guo Y, Zou R, Hu H, Wang Y, Wang F, Ju LA (2022a) Recent advances of optical tweezers—based dynamic force spectroscopy and mechanical measurement assays for live-cell mechanobiology. Front Phys. https://doi.org/10.3389/fphy.2022.771111
Wang H, Zhou F, Guo Y, Ju LA (2022b) Micropipette-based biomechanical nanotools on living cells. Eur Biophys J. https://doi.org/10.1007/s00249-021-01587-5
Xue F, Cox CD, Bavi N, Rohde PR, Nakayama Y, Martinac B (2020) Membrane stiffness is one of the key determinants of E. coli MscS channel mechanosensitivity. Biochim Biophys Acta Biomembr 1862:183203
Acknowledgements
We thank Ran Zou and Fang Zhou for helpful discussion; Freda Passam, Shaun Jackson, Laura Moldovan and their research group members at the Heart Research Institute for blood collection. We thank the University of Sydney core research facilities—Sydney Manufacturing Hub and Research Prototype Foundry for support of our lab startup. We thank Benjamin Eggleton, Daniele Vigolo and Stefano Palomba for research collaboration and industry engagement through Sydney Nanohealth networks under Sydney Nano.
Funding
Open Access funding enabled and organized by CAUL and its Member Institutions. This work was supported by Australian Research Council (ARC) Discovery Project (DP200101970—L.A.J.), the National Health and Medical Research Council (NHMRC) of Australia Ideas Grant (APP2003904—L.A.J. and C.D.C.), NSW Cardiovascular Capacity Building Program (Early–Mid-Career Researcher Grant—L.A.J.), Sydney Nano Grand Challenge funding (GC2022—L.A.J.), NSW CVRN-VCCRI Research Innovation Grant and Ramaciotti Foundations Health Investment Grant (2020HIG76—L.A.J. and C.D.C.), USYD External Research Collaboration Seed Funding and NSW Government’s Boosting Business Innovation Program (BBIP—L.A.J.). L.A.J. is an ARC DECRA fellow (DE190100609) and National Heart Foundation Future Leader Level-2 (FLF2 105863). Q.P.S. is an NHMRC Investigator Emerging Leader (APP1177374) and National Heart Foundation Postdoctoral Fellow (PDF 102592).
Author information
Authors and Affiliations
Contributions
HW and PO have contributed equally. HW, PO and LAJ designed the study. HW and PO performed experiments and analyzed the data. ZW set up the pneumatic high-speed pressure clamp device. YZ assisted image analysis and micropipette system instrumentation. YW, CDC and QPS assisted calcium experiments and data analysis. All authors co-wrote the paper. Lining Arnold Ju supervised the study and wrote the paper.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest.
Ethical approval
All procedures involving the collection of human blood were in accordance with the Human Research Ethics Committee (HREC, project 2014/244) at the University of Sydney.
Consent for publication
Not applicable.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Special issue: Nanoengineering for Mechanobiology.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Wang, H., Obeidy, P., Wang, Z. et al. Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing. Eur Biophys J 51, 135–146 (2022). https://doi.org/10.1007/s00249-022-01595-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00249-022-01595-z